search
Back to results

The MOTOR-CD Trial

Primary Purpose

Crohn's Disease

Status
Completed
Phase
Not Applicable
Locations
India
Study Type
Interventional
Intervention
Novel motorized spiral enteroscopy
Single balloon enteroscopy
Sponsored by
Asian Institute of Gastroenterology, India
About
Eligibility
Locations
Arms
Outcomes
Full info

About this trial

This is an interventional diagnostic trial for Crohn's Disease focused on measuring Device-assisted enteroscopy, Single balloon enteroscopy, Novel motorized spiral enteroscopy, total enteroscopy

Eligibility Criteria

18 Years - 65 Years (Adult, Older Adult)All SexesDoes not accept healthy volunteers

Inclusion Criteria:

  1. Patients with suspected of known IBD requiring small bowel endoscopy
  2. Ability to give a signed informed consent.
  3. Age ≥18 years -65 years -

Exclusion Criteria:

  1. Patient not fit for general anaesthesia
  2. Pediatric Patients (<18 years)
  3. Pregnant or lactating mother
  4. Post operative cases
  5. Not willing to participate

Sites / Locations

  • Asian Institute of Gastroenterology

Arms of the Study

Arm 1

Arm 2

Arm Type

Active Comparator

Active Comparator

Arm Label

Single balloon enteroscopy

Novel Motorized Spiral Enteroscopy

Arm Description

Patients with suspected Crohn's disease requiring small bowel enteroscopy based on clinical features, laboratory investigation and in cross-sectional imaging (computed tomography/magnetic resonance enterography or enteroclysis/ video capsule endoscopy

Patients with suspected Crohn's disease requiring small bowel enteroscopy based on clinical features, laboratory investigation and in cross-sectional imaging (computed tomography/magnetic resonance enterography or enteroclysis/ video capsule endoscopy

Outcomes

Primary Outcome Measures

Comparison of technical success with NMSE and SBE per patient [%]
Percentage of participants in which anatomical region of interest is reached

Secondary Outcome Measures

Comparison of diagnostic yield with NMSE and SBE per procedure [%]
Percentage of enteroscopy procedures in which Crohn's disease or other disease is diagnosed or ruled out
Comparison of procedure time with NMSE and SBE[minutes]
Time from enteroscope insertion to withdrawal
Comparison of depth of maximal insertion with NMSE and SBE [centimetres]
Maximum depth reached by NMSE/SBE from duodenojejunal flexure for antegrade and ileocecal valve for retrograde enteroscopy
Comparison of total enteroscopy rates with NMSE and SBE [percentage]
Percentage of cases in which total small bowel examination is performed
Comparison of adverse events with NMSE and SBE [percentage]
Major adverse events are perforation, pancreatitis, bleeding requiring transfusion or procedure related hospitalization. Minor adverse events are superficial mucosal injury, self limiting sore throat/nausea/vomiting, minor bleeding (without need for blood transfusion) or pain abdomen (not requiring hospital admission).

Full Information

First Posted
April 28, 2022
Last Updated
September 13, 2023
Sponsor
Asian Institute of Gastroenterology, India
search

1. Study Identification

Unique Protocol Identification Number
NCT05363930
Brief Title
The MOTOR-CD Trial
Official Title
Randomized Controlled Trial Comparing Diagnostic Yield for Small Bowel Endoscopy Between Novel Motorized Spiral and Single Balloon Enteroscopy in Suspected Crohn's Disease (the MOTOR-CD Trial)
Study Type
Interventional

2. Study Status

Record Verification Date
September 2023
Overall Recruitment Status
Completed
Study Start Date
May 7, 2022 (Actual)
Primary Completion Date
September 30, 2022 (Actual)
Study Completion Date
September 30, 2022 (Actual)

3. Sponsor/Collaborators

Responsible Party, by Official Title
Sponsor
Name of the Sponsor
Asian Institute of Gastroenterology, India

4. Oversight

Studies a U.S. FDA-regulated Drug Product
No
Studies a U.S. FDA-regulated Device Product
No
Product Manufactured in and Exported from the U.S.
No
Data Monitoring Committee
Yes

5. Study Description

Brief Summary
Both single-balloon enteroscopy (SBE) and novel motorized spiral enteroscopy (NMSE) are effective techniques for small bowel endoscopy in suspected Crohn's disease (CD). Small bowel endoscopy is indicated for confirming diagnosis when CD is suspected based on clinical features along with cross-sectional small bowel imaging (computed tomography enterography/enteroclysis: CTE or magnetic resonance enterography/enteroclysis: MRE) or capsule endoscopy (CE). It not only helps in diagnosing CD, but it also helps in excluding CD, diagnosing alternate conditions and taking a surgical decision if a tight stricture is found. The pilot study done by the investigators in 177 suspected CD patients (37.2% female, 7-75 years) undergoing total 201 device assisted enteroscopy (DAE) showed that NMSE scores over SBE with regards to small bowel evaluation with complete small bowel coverage and shorter procedure time. The investigators aim to validate this findings by comparing technical performance and diagnostic yield between NMSE (Olympus Medical, Tokyo, Japan) and SBE (Olympus Medical Systems Corporation, Tokyo, Japan) for small bowel evaluation. Additionally the investigators plan to compare depth of insertion, total enteroscopy rates, procedure time, adverse event rates between the two modalities. To date, no study has compared both modalities in suspected Crohn's disease (CD) requiring small bowel evaluation in a randomized manner. Hence the investigators intend to perform a randomized controlled study based on these preliminary finding with appropriate matching and parallel study design in larger numbers.
Detailed Description
Study design Study population Consecutive patients with suspected Crohn's disease requiring small bowel endoscopy based on abnormal imaging or capsule endoscopy shall be recruited. Study settings: The proposed study would be conducted in a high volume tertiary GI centre (Asian Institute of Gastroenterology) performing nearly more than 500 SBE/NMSE procedures per year with an well established inflammatory bowel disease (IBD) registry with more than 7000 IBD patients under follow up. The study is approved by the institutional review boards and ethics committee. Written informed consent would be taken from each participants and the study would conform to the 1975 Declaration of Helsinki ethical guidelines. Data collection A survey administration software (google forms) would be used to collect the participant data [age, sex, comorbidities, clinical features, smoking status, history of intestinal resection, type of DAE, indication of DAE, CT/MRE location and characteristic of lesions, capsule endoscopy findings, depth of insertion, time taken for the procedure, total enteroscopy rates, enteroscopy finding details, cause of failure if any, DAE findings, histopathology details, impact on management, adverse events, hospital stay and any therapeutic procedure performed e.g. endoscopic balloon dilation (EBD) with details]. Follow-up details for newly diagnosed CD cases would be collected via physical visit or telephonic communication. Technique and instruments Single balloon enteroscopy: All SBE procedures will be performed with single balloon video-enteroscope (Olympus Medical Systems, Tokyo, Japan) under monitored anaesthesia (deep sedation with propofol). Initially antegrade/retrograde enteroscopy would be performed based on anticipated location in CT failing which enteroscopy would be done from opposite route to reach the lesion. If the desired lesion is not reached via antegrade/retrograde route, hemoclips would be applied or tattooing would be done followed by enteroscopy from opposite direction on the same day under the same anaesthesia using the same overtube. Fluoroscopy would be used in select cases with anticipated therapeutic procedure. All the procedures were done after minimum of 8 hours of fasting and bowel preparation was given with 4 litres of polyethylene glycol (PEG) for all. Duration of procedure would be calculated from the time of introduction of the enteroscope to time of removal. The depth of insertion would be measured using the push and pull technique. If the desired lesion is not reached by a single route and was deemed possible to reach by the other route, the area of maximal insertion shall be marked by India ink tattooing or hemoclip application followed by completion of bidirectional enteroscopy on the same or next working day. Novel motorized spiral enteroscopy: All the NMSE (Olympus Medical Systems Corporation, Tokyo, Japan) procedures would be performed under general anaesthesia with nasotracheal intubation under fluoroscopic guidance. Four litres of PEG was given to all patients with at least 8 hours of fasting prior to NMSE. Initially antegrade enteroscopy would be performed failing which retrograde enteroscopy would be done to reach the lesion. If the desired lesion is not reached via antegrade route, hemoclips would be applied or tattooing would be done followed by retrograde enteroscopy on the same day under the same anesthesia using the same overtube. The time of procedure will be calculated from insertion of NMSE to its withdrawal. The depth of insertion would be measured by sequential withdrawal technique as described earlier. All the enteroscopy procedures were performed by four small bowel endoscopists all of whom have performed at least 200 deep enteroscopy. At least 8 biopsies were taken from area of interest during DAE and sent for histopathological analysis. In selected cases, additional samples were sent for detection of tubercular bacilli using mycobacterium tuberculosis (MTB)-polymerase chain reaction (PCR) if clinically tuberculosis was considered as differential diagnosis. Histopathological findings were recorded under the following headings for diagnosing CD: chronic inflammation, architectural distortion and presence of granulomas. Definitions: Technical success shall be defined as enteroscope introduction beyond duodenojejunal (DJ) flexure or ileocecal valve via antegrade and retrograde route respectively. The diagnostic yield with DAE shall be defined as the percentage of procedures which confirmed/excluded lesions found on prior cross-sectional imaging (CTE/MRE) or found new/alternate diagnosis explaining the clinical condition. Depth of maximal insertion (DMI) will be defined as the point beyond which DAE advancement was not feasible. Major adverse events are perforation, pancreatitis, bleeding requiring transfusion or procedure related hospitalization. Minor adverse events are superficial mucosal injury, self limiting sore throat/nausea/vomiting, minor bleeding (without need for blood transfusion) or pain abdomen (not requiring hospital admission). Total enteroscopy will be defined as examination of small bowel from DJ flexure to ileocecal valve. Total enteroscopy would be achieved by either uni-directional (antegrade or retrograde route) or bi-directional enteroscopy (using both antegrade and retrograde route). The histopathological diagnosis of CD will be confirmed if non-caseating micro-granulomas are found with either of both of the other two histological features (chronic inflammation and architectural distortion) and alternate diagnosis like small bowel tuberculosis is ruled out based on clinical, radiologic and other relevant findings. Presence of both chronic inflammation and architectural distortion, non-caseating granuloma/chronic inflammation/ architectural distortion alone will be considered suggestive of CD in the appropriate clinical settings. Sample size Based on the pilot study by the investigators, diagnostic yield for deep enteroscopy with NMSE and SBE (97.8% and 83.2% respectively, the estimated sample size is total 124 (62 in each group) keeping type 1 error as 0.05 and power as 80%. Randomisation Randomisation will be done based on web based randomisation services Timeline: 2 years Recruitment of 124 suspected CD patients requiring small bowel evaluation over maximum 2 years. Patient privacy An organised database for the purpose of this study will be formed based on google form with anonymised data set (i.e. name, address, and full post code will be removed, together with any other information which, in conjunction with other data held by or disclosed to the recipient, could identify the patient) which would be entered by clinical research assistant.

6. Conditions and Keywords

Primary Disease or Condition Being Studied in the Trial, or the Focus of the Study
Crohn's Disease
Keywords
Device-assisted enteroscopy, Single balloon enteroscopy, Novel motorized spiral enteroscopy, total enteroscopy

7. Study Design

Primary Purpose
Diagnostic
Study Phase
Not Applicable
Interventional Study Model
Parallel Assignment
Masking
None (Open Label)
Allocation
Randomized
Enrollment
128 (Actual)

8. Arms, Groups, and Interventions

Arm Title
Single balloon enteroscopy
Arm Type
Active Comparator
Arm Description
Patients with suspected Crohn's disease requiring small bowel enteroscopy based on clinical features, laboratory investigation and in cross-sectional imaging (computed tomography/magnetic resonance enterography or enteroclysis/ video capsule endoscopy
Arm Title
Novel Motorized Spiral Enteroscopy
Arm Type
Active Comparator
Arm Description
Patients with suspected Crohn's disease requiring small bowel enteroscopy based on clinical features, laboratory investigation and in cross-sectional imaging (computed tomography/magnetic resonance enterography or enteroclysis/ video capsule endoscopy
Intervention Type
Device
Intervention Name(s)
Novel motorized spiral enteroscopy
Intervention Description
Novel motorized spiral enteroscopy (Olympus Medical Systems Corporation, Tokyo, Japan) procedures would be performed under general anaesthesia with nasotracheal intubation under fluoroscopic guidance. Four litres of PEG was given to all patients with at least 8 hours of fasting prior to NMSE. Initially antegrade enteroscopy would be performed failing which retrograde enteroscopy would be done to reach the lesion. If the desired lesion is not reached via antegrade/retrograde route, hemoclips would be applied or tattooing would be done followed by enteroscopy from opposite direction on the same day under the same anesthesia using the same overtube. The time of procedure will be calculated from insertion of NMSE to its withdrawal. The depth of insertion would be measured by sequential withdrawal technique.
Intervention Type
Device
Intervention Name(s)
Single balloon enteroscopy
Intervention Description
Single balloon enteroscopy will be performed with single balloon video-enteroscope (Olympus Medical Systems, Tokyo, Japan) under monitored anaesthesia (deep sedation with propofol). Initially antegrade/retrograde enteroscopy would be performed based on pre-procedure localization failing which enteroscopy would be done from opposite route to reach the lesion. Hemoclips would be applied or tattooing would be done followed by enteroscopy from opposite direction on the same day under the same anaesthesia using the same overtube. Duration of procedure would be calculated from the time of introduction of the enteroscope to time of removal. The depth of insertion would be measured using the push and pull technique.
Primary Outcome Measure Information:
Title
Comparison of technical success with NMSE and SBE per patient [%]
Description
Percentage of participants in which anatomical region of interest is reached
Time Frame
2 years
Secondary Outcome Measure Information:
Title
Comparison of diagnostic yield with NMSE and SBE per procedure [%]
Description
Percentage of enteroscopy procedures in which Crohn's disease or other disease is diagnosed or ruled out
Time Frame
2 years
Title
Comparison of procedure time with NMSE and SBE[minutes]
Description
Time from enteroscope insertion to withdrawal
Time Frame
2 years
Title
Comparison of depth of maximal insertion with NMSE and SBE [centimetres]
Description
Maximum depth reached by NMSE/SBE from duodenojejunal flexure for antegrade and ileocecal valve for retrograde enteroscopy
Time Frame
2 years
Title
Comparison of total enteroscopy rates with NMSE and SBE [percentage]
Description
Percentage of cases in which total small bowel examination is performed
Time Frame
2 years
Title
Comparison of adverse events with NMSE and SBE [percentage]
Description
Major adverse events are perforation, pancreatitis, bleeding requiring transfusion or procedure related hospitalization. Minor adverse events are superficial mucosal injury, self limiting sore throat/nausea/vomiting, minor bleeding (without need for blood transfusion) or pain abdomen (not requiring hospital admission).
Time Frame
2 years

10. Eligibility

Sex
All
Minimum Age & Unit of Time
18 Years
Maximum Age & Unit of Time
65 Years
Accepts Healthy Volunteers
No
Eligibility Criteria
Inclusion Criteria: Patients with suspected of known IBD requiring small bowel endoscopy Ability to give a signed informed consent. Age ≥18 years -65 years - Exclusion Criteria: Patient not fit for general anaesthesia Pediatric Patients (<18 years) Pregnant or lactating mother Post operative cases Not willing to participate
Facility Information:
Facility Name
Asian Institute of Gastroenterology
City
Hyderabad
State/Province
Telangana
ZIP/Postal Code
500008
Country
India

12. IPD Sharing Statement

Learn more about this trial

The MOTOR-CD Trial

We'll reach out to this number within 24 hrs