search
Back to results

Study of Sirolimus-Coated BX VELOCITY Balloon-Expandable Stent in Treatment of de Novo Native Coronary Artery Lesions (SIRIUS)

Primary Purpose

Coronary Artery Disease

Status
Completed
Phase
Phase 3
Locations
United States
Study Type
Interventional
Intervention
CYPHER Sirolimus-Eluting Stent
Uncoated BX VELOCITY Balloon-Expandable Stent
Sponsored by
Cordis Corporation
About
Eligibility
Locations
Arms
Outcomes
Full info

About this trial

This is an interventional treatment trial for Coronary Artery Disease

Eligibility Criteria

18 Years - undefined (Adult, Older Adult)All SexesDoes not accept healthy volunteers

Inclusion Criteria: Male or non-pregnant female patients minimum 18 years of age Diagnosis of angina pectoris as defined by Canadian Cardiovascular Society Classification (CCS I, II, III, IV) OR unstable angina pectoris (Braunwald Classification B&C, I-II) OR patients with documented silent ischemia; Target lesion is 2.50mm and 3.5mm in diameter (visual estimate); Target lesion is 15mm and 30mm in length (visual estimate); Target lesion stenosis is >50% and <100% (visual estimate); Exclusion Criteria: Patient has experienced a Q-wave or non-Q-wave myocardial infarction with documented total CK >2 times normal within the preceding 24 hours and the CK and CK-MB enzymes remains above normal at the time of treatment; Has unstable angina classified as Braunwald III B or C, or is having a peri infarction; Documented Left ventricular ejection fraction 25%; Impaired renal function (creatinine > 3.0 mg/dl) at the time of treatment; Target lesion involves bifurcation including a diseased side branch 2.5mm in diameter (either stenosis of both main vessel and major branch or stenosis of just major branch) that would require treatment;

Sites / Locations

  • New York Presbyterian Hospital/Columbia University Medical Center

Arms of the Study

Arm 1

Arm 2

Arm Type

Experimental

Active Comparator

Arm Label

1

2

Arm Description

Cypher Bx Velocity

Uncoated Bx Velocity

Outcomes

Primary Outcome Measures

Target vessel failure (TVF) defined as cardiac death, myocardial infarction, or target vessel revascularization at 9 months post-procedure.

Secondary Outcome Measures

Composite of MACE defined as death, myocardial infarction (Q wave and non-Q wave), emergent bypass surgery, or repeat target vessel revascularization at 30 dys and 3, 6, 9, and 12 mo, and 2, 3, 4, 5, 6, 7, and 8 yrs post-procedure;
Angiographic binary restenosis (>/=50% diameter stenosis) 8 mo post-procedure;
In-stent and in-lesion MLD at 8 mo post-procedure;
Target lesion revascularization at 9 mo post-procedure;
Target vessel revascularization at 9 mo post-procedure;
Device success defined as achievement of a final residual diameter stenosis of <50% (by QCA), using the assigned device only. If QCA is not available, the visual estimate of diameter stenosis is used;
Lesion success defined as the attainment of <50% residual stenosis (by QCA) using any percutaneous method;
Procedure success defined as achievement of a final diameter stenosis of <50% (by QCA) using any percutaneous method, without the occurrence of death, MI, or repeat revascularization of the target lesion during the hospital stay;
Costs associated with the index hospitalization and length of stay, and repeat hospitalizations during the 12-month post-procedure follow-up period.

Full Information

First Posted
October 3, 2005
Last Updated
September 15, 2009
Sponsor
Cordis Corporation
search

1. Study Identification

Unique Protocol Identification Number
NCT00232765
Brief Title
Study of Sirolimus-Coated BX VELOCITY Balloon-Expandable Stent in Treatment of de Novo Native Coronary Artery Lesions (SIRIUS)
Official Title
A Multicenter, Randomized, Double-Blind Study of the Sirolimus-Coated BX VELOCITYTM Balloon-Expandable Stent in the Treatment of Patients With de Novo Coronary Artery Lesions
Study Type
Interventional

2. Study Status

Record Verification Date
September 2009
Overall Recruitment Status
Completed
Study Start Date
February 2001 (undefined)
Primary Completion Date
May 2002 (Actual)
Study Completion Date
November 2008 (Actual)

3. Sponsor/Collaborators

Name of the Sponsor
Cordis Corporation

4. Oversight

Data Monitoring Committee
Yes

5. Study Description

Brief Summary
The main objective of this study is to assess the safety and effectiveness of the sirolimus-coated Bx VELOCITYTM stent in reducing target vessel failure in de novo native coronary artery lesions as compared to the uncoated Bx VELOCITYTM balloon-expandable stent. Both stents are mounted on the Raptorâ over-the-wire (OTW) Stent Delivery System.
Detailed Description
This is a multicenter (55 sites), prospective, 2-arm randomized, double-blind study designed to assess the safety and effectiveness of the sirolimus-coated Bx VELOCITYTM stent as compared to the uncoated Bx VELOCITYTM stent. A total of 1100 patients will be entered in the study and will be randomized on a 1:1 basis. Patients with de novo native coronary artery lesions >/=15mm and </=30mm in length and >/=2.50mm to </=3.5mm in diameter by visual estimate who meet all eligibility criteria will be either randomized to the sirolimus-coated Bx VELOCITYTM stent or the uncoated Bx VELOCITYTM stent. Patients will be followed at 30 days, 3, 6, 9 and 12 months, and 2, 3, 4, 5, 6, 7, and 8 years post-procedure, with approximately 850 patients having repeat angiography at 8 months. A subset of approximately 17 centers will participate in an intravascular ultrasound (IVUS) sub study, in which all patients at these centers will be enrolled in the sub study. Additionally, data will be collected for a medical economic analysis. These data will include costs associated with the index hospitalization and length of stay, and rehospitalizations during the 12-month follow-up period. This is a single lesion treatment study. Patients who have had interventions of other lesions within 30 days of the study procedure or have interventions planned after the index procedure are excluded. It is anticipated that the total length of the study will be 101 months: 5 months to complete patient enrollment and 8 years for follow-up.

6. Conditions and Keywords

Primary Disease or Condition Being Studied in the Trial, or the Focus of the Study
Coronary Artery Disease

7. Study Design

Primary Purpose
Treatment
Study Phase
Phase 3
Interventional Study Model
Parallel Assignment
Masking
ParticipantInvestigator
Allocation
Randomized
Enrollment
1058 (Actual)

8. Arms, Groups, and Interventions

Arm Title
1
Arm Type
Experimental
Arm Description
Cypher Bx Velocity
Arm Title
2
Arm Type
Active Comparator
Arm Description
Uncoated Bx Velocity
Intervention Type
Device
Intervention Name(s)
CYPHER Sirolimus-Eluting Stent
Intervention Description
CYPHER Sirolimus-Eluting Stent
Intervention Type
Device
Intervention Name(s)
Uncoated BX VELOCITY Balloon-Expandable Stent
Intervention Description
Uncoated BX VELOCITY Balloon-Expandable Stent
Primary Outcome Measure Information:
Title
Target vessel failure (TVF) defined as cardiac death, myocardial infarction, or target vessel revascularization at 9 months post-procedure.
Time Frame
9 months post procedure
Secondary Outcome Measure Information:
Title
Composite of MACE defined as death, myocardial infarction (Q wave and non-Q wave), emergent bypass surgery, or repeat target vessel revascularization at 30 dys and 3, 6, 9, and 12 mo, and 2, 3, 4, 5, 6, 7, and 8 yrs post-procedure;
Time Frame
30 dys and 3, 6, 9, and 12 mo, and 2, 3, 4, 5, 6, 7, and 8 yrs post-procedure
Title
Angiographic binary restenosis (>/=50% diameter stenosis) 8 mo post-procedure;
Time Frame
8 months post-procedure
Title
In-stent and in-lesion MLD at 8 mo post-procedure;
Time Frame
8 months post-procedure
Title
Target lesion revascularization at 9 mo post-procedure;
Time Frame
9 months post-procedure
Title
Target vessel revascularization at 9 mo post-procedure;
Time Frame
9 months post-procedure
Title
Device success defined as achievement of a final residual diameter stenosis of <50% (by QCA), using the assigned device only. If QCA is not available, the visual estimate of diameter stenosis is used;
Time Frame
Study Completion
Title
Lesion success defined as the attainment of <50% residual stenosis (by QCA) using any percutaneous method;
Time Frame
Study Completion
Title
Procedure success defined as achievement of a final diameter stenosis of <50% (by QCA) using any percutaneous method, without the occurrence of death, MI, or repeat revascularization of the target lesion during the hospital stay;
Time Frame
During the hospital stay
Title
Costs associated with the index hospitalization and length of stay, and repeat hospitalizations during the 12-month post-procedure follow-up period.
Time Frame
12-month post-procedure

10. Eligibility

Sex
All
Minimum Age & Unit of Time
18 Years
Accepts Healthy Volunteers
No
Eligibility Criteria
Inclusion Criteria: Male or non-pregnant female patients minimum 18 years of age Diagnosis of angina pectoris as defined by Canadian Cardiovascular Society Classification (CCS I, II, III, IV) OR unstable angina pectoris (Braunwald Classification B&C, I-II) OR patients with documented silent ischemia; Target lesion is 2.50mm and 3.5mm in diameter (visual estimate); Target lesion is 15mm and 30mm in length (visual estimate); Target lesion stenosis is >50% and <100% (visual estimate); Exclusion Criteria: Patient has experienced a Q-wave or non-Q-wave myocardial infarction with documented total CK >2 times normal within the preceding 24 hours and the CK and CK-MB enzymes remains above normal at the time of treatment; Has unstable angina classified as Braunwald III B or C, or is having a peri infarction; Documented Left ventricular ejection fraction 25%; Impaired renal function (creatinine > 3.0 mg/dl) at the time of treatment; Target lesion involves bifurcation including a diseased side branch 2.5mm in diameter (either stenosis of both main vessel and major branch or stenosis of just major branch) that would require treatment;
Overall Study Officials:
First Name & Middle Initial & Last Name & Degree
Martin B. Leon, MD
Organizational Affiliation
New York Presbyterian Hospital/Columbia University Medical Center
Official's Role
Principal Investigator
First Name & Middle Initial & Last Name & Degree
Jeffrey Moses, MD
Organizational Affiliation
New York Presbyterian Hospital/Columbia University Medical Center
Official's Role
Principal Investigator
Facility Information:
Facility Name
New York Presbyterian Hospital/Columbia University Medical Center
City
New York
State/Province
New York
ZIP/Postal Code
10032
Country
United States

12. IPD Sharing Statement

Citations:
PubMed Identifier
14523139
Citation
Moses JW, Leon MB, Popma JJ, Fitzgerald PJ, Holmes DR, O'Shaughnessy C, Caputo RP, Kereiakes DJ, Williams DO, Teirstein PS, Jaeger JL, Kuntz RE; SIRIUS Investigators. Sirolimus-eluting stents versus standard stents in patients with stenosis in a native coronary artery. N Engl J Med. 2003 Oct 2;349(14):1315-23. doi: 10.1056/NEJMoa035071.
Results Reference
background
PubMed Identifier
19389558
Citation
Weisz G, Leon MB, Holmes DR Jr, Kereiakes DJ, Popma JJ, Teirstein PS, Cohen SA, Wang H, Cutlip DE, Moses JW. Five-year follow-up after sirolimus-eluting stent implantation results of the SIRIUS (Sirolimus-Eluting Stent in De-Novo Native Coronary Lesions) Trial. J Am Coll Cardiol. 2009 Apr 28;53(17):1488-97. doi: 10.1016/j.jacc.2009.01.050.
Results Reference
result
PubMed Identifier
19327417
Citation
Popma JJ, Tiroch K, Almonacid A, Cohen S, Kandzari DE, Leon MB. A qualitative and quantitative angiographic analysis of stent fracture late following sirolimus-eluting stent implantation. Am J Cardiol. 2009 Apr 1;103(7):923-9. doi: 10.1016/j.amjcard.2008.12.022.
Results Reference
result
PubMed Identifier
19539252
Citation
Chacko R, Mulhearn M, Novack V, Novack L, Mauri L, Cohen SA, Moses J, Leon MB, Cutlip DE. Impact of target lesion and nontarget lesion cardiac events on 5-year clinical outcomes after sirolimus-eluting or bare-metal stenting. JACC Cardiovasc Interv. 2009 Jun;2(6):498-503. doi: 10.1016/j.jcin.2009.03.013.
Results Reference
result
PubMed Identifier
17296825
Citation
Spaulding C, Daemen J, Boersma E, Cutlip DE, Serruys PW. A pooled analysis of data comparing sirolimus-eluting stents with bare-metal stents. N Engl J Med. 2007 Mar 8;356(10):989-97. doi: 10.1056/NEJMoa066633. Epub 2007 Feb 12.
Results Reference
derived

Learn more about this trial

Study of Sirolimus-Coated BX VELOCITY Balloon-Expandable Stent in Treatment of de Novo Native Coronary Artery Lesions (SIRIUS)

We'll reach out to this number within 24 hrs