search
Back to results

TAXUS IV-SR: Treatment of De Novo Coronary Disease Using a Single Paclitaxel-Eluting Stent

Primary Purpose

Coronary Artery Disease

Status
Completed
Phase
Phase 2
Locations
United States
Study Type
Interventional
Intervention
percutaneous coronary intervention
Sponsored by
Boston Scientific Corporation
About
Eligibility
Locations
Arms
Outcomes
Full info

About this trial

This is an interventional treatment trial for Coronary Artery Disease focused on measuring coronary artery disease, percutaneous coronary interventions, stent implant, drug-coated stent

Eligibility Criteria

18 Years - undefined (Adult, Older Adult)All SexesDoes not accept healthy volunteers

Inclusion Criteria: Patient is > or = 18 years old Eligible for percutaneous coronary intervention (PCI) Documented stable angina pectoris (Canadian Cardiovascular Society Classification [CCS] 1, 2, 3, or 4) or unstable angina pectoris with documented ischemia (Braunwald Class IB-C, IIB-C, or IIIB-C), or documented silent ischemia Left ventricular ejection fraction (LVEF) of > or = 25% Acceptable candidate for CABG Patient (or legal guardian) understands the study requirements and the treatment procedures and provides written Informed Consent before any study-specific tests or procedures are performed Willing to comply with all specified follow-up evaluations 1. Target lesion located within a single native coronary vessel 2. Target lesion randomized to treatment with the study device may be composed of multiple lesions but must be completely coverable by one (1) study stent 3. Cumulative target lesion length is > or = 10 mm and < or = 28 mm (visual estimate) 4. RVD of > or = 2.5mm to < or = 3.75 mm (visual estimate) 5. Target lesion diameter stenosis > or = 50% (visual estimate) 6. Target lesion is de novo (i.e., a coronary lesion not previously treated) 7. Target lesion located within a single native coronary vessel 8. Target lesion randomized to treatment with the study device may be composed of multiple lesions but must be completely coverable by one (1) study stent 9. Cumulative target lesion length is > or = 10 mm and < or = 28 mm (visual estimate) 10. RVD of > or = 2.5mm to < or = 3.75 mm (visual estimate) 11. Target lesion diameter stenosis > or = 50% (visual estimate) 12. Target lesion is de novo (i.e., a coronary lesion not previously treated) - Exclusion Criteria: 1. Known sensitivity to paclitaxel 2. Any previous or planned treatment with a non-study anti-restenotic drug-coated or drug-eluting coronary stent. (Note: previous or planned treatment with heparin or phosphorylcholine coated stents is acceptable, as long as the procedure with the non-study stent meets the protocol defined criteria for staged procedures) 3. Previous or planned treatment with intravascular brachytherapy in the target vessel 4. MI within 72 hours prior to the index procedure and/or CK-MB >2x the local laboratory's upper limits of normal (refers to a measured value on the day of the index procedure) 5. Cerebrovascular Accident (CVA) within the past 6 months 6. Acute or chronic renal dysfunction (creatinine >2.0 mg/dl or >150 µmol/L) 7. Contraindication to ASA, or to both clopidogrel and ticlopidine 8. Leukopenia (leukocyte count <3.5 x 109/liter) 9. Thrombocytopenia (platelet count <100,000/mm3) 10. Active peptic ulcer or active gastrointestinal (GI) bleeding 11. Known allergy to stainless steel 12. Any prior true anaphylactic reaction to contrast agents 13. Known anaphylactoid or other non-anaphylactic allergic reactions to contrast agents that cannot be adequately pre-medicated prior to the index procedure 14. Patient is currently taking colchicine 15. Patient is currently, or has been treated with paclitaxel within 12 months of the index procedure 16. Female of childbearing potential with a positive pregnancy test within 7 days before the index procedure, or lactating, or intends to become pregnant during the study 17. Life expectancy of less than 24 months due to other medical conditions 18. Co-morbid condition(s) that could limit the patient's ability to participate in the study, compliance with follow-up requirements or impact the scientific integrity of the study 19. Currently participating in another investigational drug or device study that has not completed the primary endpoint or that clinically interferes with the endpoints of this study -

Sites / Locations

  • Stephen G.Ellis

Arms of the Study

Arm 1

Arm 2

Arm Type

Experimental

Placebo Comparator

Arm Label

TAXUS Express

Express Bare

Arm Description

Outcomes

Primary Outcome Measures

The primary objective of this study is to evaluate the safety and effectiveness of the TAXUS Stent System with 1 ug/mm2 (loaded drug/stent surface area) of paclitaxel incorporated into a slow rate-release formulation of a triblock copolymer carrier syst

Secondary Outcome Measures

Secondary endpoints include the following:
• Rates of composite MACE and the individual components of MACE (MI, TVR, Cardiac Death), assessed at 1, 4 and 9 months after the index procedure and annually for 5 more years (i.e., 1, 2, 3, 4, and 5 years after the index procedure).
• Stent thrombosis rate
• Target Vessel Failure
• Clinical procedural success
• Binary restenosis rate

Full Information

First Posted
February 14, 2006
Last Updated
October 7, 2008
Sponsor
Boston Scientific Corporation
search

1. Study Identification

Unique Protocol Identification Number
NCT00292474
Brief Title
TAXUS IV-SR: Treatment of De Novo Coronary Disease Using a Single Paclitaxel-Eluting Stent
Official Title
TAXUS IV-SR: Treatment of De Novo Coronary Disease Using a Single Paclitaxel-Eluting Stent
Study Type
Interventional

2. Study Status

Record Verification Date
October 2008
Overall Recruitment Status
Completed
Study Start Date
March 2002 (undefined)
Primary Completion Date
August 2007 (Actual)
Study Completion Date
August 2007 (Actual)

3. Sponsor/Collaborators

Name of the Sponsor
Boston Scientific Corporation

4. Oversight

5. Study Description

Brief Summary
The ultimate goal of a paclitaxel eluting stent system (TAXUS stent) is to prevent restenosis by blunting the initial response to stent implant injury and sustaining the arrested response until vascular healing has taken place. The purpose of the TAXUS IV-SR trial is to study the safety and efficacy of the TAXUS Stent under controlled trial circumstances used in the treatment of new coronary artery lesions (heart blockages) This clinical investigation will evaluate the safety and effectiveness of the TAXUS Stent with 1 ug/mm2 (loaded drug/stent surface area) of paclitaxel incorporated into a slow rate-release formulation of a triblock copolymer carrier system for treatment of new coronary artery lesions.
Detailed Description
This was a prospective randomized, double-blind, multicenter safety and efficacy trial. Patients were stratified by presence or absence of medically treated diabetes mellitus and vessel diameter (<3.0 mm or >/=3.0 mm), then randomized 1:1 to receive either the TAXUS Stent or a Control stent. Additional study stents were permitted to optimize outcomes. The study was considered complete (with regard to the primary endpoint) after all patients enrolled had completed the 9 month follow-up. Enrollment of 1172 patients was planned; 1326 were treated and randomized at 73 centers involving 76 sites by 8 July 2002 with 667 in the TAXUS group and 659 in the Control group.

6. Conditions and Keywords

Primary Disease or Condition Being Studied in the Trial, or the Focus of the Study
Coronary Artery Disease
Keywords
coronary artery disease, percutaneous coronary interventions, stent implant, drug-coated stent

7. Study Design

Primary Purpose
Treatment
Study Phase
Phase 2, Phase 3
Interventional Study Model
Parallel Assignment
Masking
ParticipantInvestigator
Allocation
Randomized
Enrollment
1326 (Actual)

8. Arms, Groups, and Interventions

Arm Title
TAXUS Express
Arm Type
Experimental
Arm Title
Express Bare
Arm Type
Placebo Comparator
Intervention Type
Device
Intervention Name(s)
percutaneous coronary intervention
Primary Outcome Measure Information:
Title
The primary objective of this study is to evaluate the safety and effectiveness of the TAXUS Stent System with 1 ug/mm2 (loaded drug/stent surface area) of paclitaxel incorporated into a slow rate-release formulation of a triblock copolymer carrier syst
Secondary Outcome Measure Information:
Title
Secondary endpoints include the following:
Title
• Rates of composite MACE and the individual components of MACE (MI, TVR, Cardiac Death), assessed at 1, 4 and 9 months after the index procedure and annually for 5 more years (i.e., 1, 2, 3, 4, and 5 years after the index procedure).
Title
• Stent thrombosis rate
Title
• Target Vessel Failure
Title
• Clinical procedural success
Title
• Binary restenosis rate

10. Eligibility

Sex
All
Minimum Age & Unit of Time
18 Years
Accepts Healthy Volunteers
No
Eligibility Criteria
Inclusion Criteria: Patient is > or = 18 years old Eligible for percutaneous coronary intervention (PCI) Documented stable angina pectoris (Canadian Cardiovascular Society Classification [CCS] 1, 2, 3, or 4) or unstable angina pectoris with documented ischemia (Braunwald Class IB-C, IIB-C, or IIIB-C), or documented silent ischemia Left ventricular ejection fraction (LVEF) of > or = 25% Acceptable candidate for CABG Patient (or legal guardian) understands the study requirements and the treatment procedures and provides written Informed Consent before any study-specific tests or procedures are performed Willing to comply with all specified follow-up evaluations 1. Target lesion located within a single native coronary vessel 2. Target lesion randomized to treatment with the study device may be composed of multiple lesions but must be completely coverable by one (1) study stent 3. Cumulative target lesion length is > or = 10 mm and < or = 28 mm (visual estimate) 4. RVD of > or = 2.5mm to < or = 3.75 mm (visual estimate) 5. Target lesion diameter stenosis > or = 50% (visual estimate) 6. Target lesion is de novo (i.e., a coronary lesion not previously treated) 7. Target lesion located within a single native coronary vessel 8. Target lesion randomized to treatment with the study device may be composed of multiple lesions but must be completely coverable by one (1) study stent 9. Cumulative target lesion length is > or = 10 mm and < or = 28 mm (visual estimate) 10. RVD of > or = 2.5mm to < or = 3.75 mm (visual estimate) 11. Target lesion diameter stenosis > or = 50% (visual estimate) 12. Target lesion is de novo (i.e., a coronary lesion not previously treated) - Exclusion Criteria: 1. Known sensitivity to paclitaxel 2. Any previous or planned treatment with a non-study anti-restenotic drug-coated or drug-eluting coronary stent. (Note: previous or planned treatment with heparin or phosphorylcholine coated stents is acceptable, as long as the procedure with the non-study stent meets the protocol defined criteria for staged procedures) 3. Previous or planned treatment with intravascular brachytherapy in the target vessel 4. MI within 72 hours prior to the index procedure and/or CK-MB >2x the local laboratory's upper limits of normal (refers to a measured value on the day of the index procedure) 5. Cerebrovascular Accident (CVA) within the past 6 months 6. Acute or chronic renal dysfunction (creatinine >2.0 mg/dl or >150 µmol/L) 7. Contraindication to ASA, or to both clopidogrel and ticlopidine 8. Leukopenia (leukocyte count <3.5 x 109/liter) 9. Thrombocytopenia (platelet count <100,000/mm3) 10. Active peptic ulcer or active gastrointestinal (GI) bleeding 11. Known allergy to stainless steel 12. Any prior true anaphylactic reaction to contrast agents 13. Known anaphylactoid or other non-anaphylactic allergic reactions to contrast agents that cannot be adequately pre-medicated prior to the index procedure 14. Patient is currently taking colchicine 15. Patient is currently, or has been treated with paclitaxel within 12 months of the index procedure 16. Female of childbearing potential with a positive pregnancy test within 7 days before the index procedure, or lactating, or intends to become pregnant during the study 17. Life expectancy of less than 24 months due to other medical conditions 18. Co-morbid condition(s) that could limit the patient's ability to participate in the study, compliance with follow-up requirements or impact the scientific integrity of the study 19. Currently participating in another investigational drug or device study that has not completed the primary endpoint or that clinically interferes with the endpoints of this study -
Overall Study Officials:
First Name & Middle Initial & Last Name & Degree
Gregg W Stone, MD
Organizational Affiliation
Columbia Hospital
Official's Role
Principal Investigator
First Name & Middle Initial & Last Name & Degree
Stephen G Ellis, MD
Organizational Affiliation
The Cleveland Clinic
Official's Role
Principal Investigator
Facility Information:
Facility Name
Stephen G.Ellis
City
Cleveland
State/Province
Ohio
ZIP/Postal Code
44195
Country
United States

12. IPD Sharing Statement

Citations:
PubMed Identifier
22496083
Citation
Wakabayashi K, Mintz GS, Weissman NJ, Stone GW, Ellis SG, Grube E, Ormiston JA, Turco MA, Pakala R, Xue Z, Desale S, Laynez-Carnicero A, Romaguera R, Sardi G, Pichard AD, Waksman R. Impact of drug-eluting stents on distal vessels. Circ Cardiovasc Interv. 2012 Apr;5(2):211-9. doi: 10.1161/CIRCINTERVENTIONS.111.965780. Epub 2012 Apr 10.
Results Reference
derived
PubMed Identifier
20129552
Citation
Ellis SG, Stone GW, Cox DA, Hermiller J, O'Shaughnessy C, Mann T, Turco M, Caputo R, Bergin PJ, Bowman TS, Baim DS; TAXUS IV Investigators. Long-term safety and efficacy with paclitaxel-eluting stents: 5-year final results of the TAXUS IV clinical trial (TAXUS IV-SR: Treatment of De Novo Coronary Disease Using a Single Paclitaxel-Eluting Stent). JACC Cardiovasc Interv. 2009 Dec;2(12):1248-59. doi: 10.1016/j.jcin.2009.10.003.
Results Reference
derived

Learn more about this trial

TAXUS IV-SR: Treatment of De Novo Coronary Disease Using a Single Paclitaxel-Eluting Stent

We'll reach out to this number within 24 hrs