search
Back to results

Attenuation Corrected Cardiac SPECT Using the GE Hawkeye Camera System (Hawkeye)

Primary Purpose

Cardiac Disease

Status
Terminated
Phase
Phase 2
Locations
United States
Study Type
Interventional
Intervention
GE Attenuation Corrected Hawkeye Camera
Sponsored by
Mayo Clinic
About
Eligibility
Locations
Arms
Outcomes
Full info

About this trial

This is an interventional diagnostic trial for Cardiac Disease focused on measuring heart disease, cardiac disease, chest pain, myocardial infarction, heart attack

Eligibility Criteria

18 Years - undefined (Adult, Older Adult)All SexesDoes not accept healthy volunteers

Inclusion Criteria:

  • Patients referred to the Charlton Nuclear Cardiology Laboratory for stress Tc-99m sestamibi SPECT

Exclusion criteria:

  • Prior PTCA or CABG
  • Left bundle branch block (LBBB) or paced ventricular rhythm
  • Clinically significant valvular heart disease
  • Hypertrophic or idiopathic dilated cardiomyopathy
  • Atrial fibrillation or frequent atrial or ventricular ectopy (defined as >20% ectopic beats
  • History of MI
  • ECG evidence of MI
  • Chest circumference >55 inches

Sites / Locations

  • Mayo Clinic

Arms of the Study

Arm 1

Arm Type

Active Comparator

Arm Label

Clinical SPECT

Arm Description

GE Hawkeye Attenuation Correction Camera is being compared to the approved clinical use SPECT camera.

Outcomes

Primary Outcome Measures

The overall comparisons of the agreement between conventional SPECT imaging and the GE Hawkeye system will be completed using McNemar's test.

Secondary Outcome Measures

Comparisons of categorical factors between the 2 tests will also be completed using McNemar's test, continuous factors will be completed using a paired t-test if the differences are normally distributed.

Full Information

First Posted
December 21, 2007
Last Updated
April 21, 2015
Sponsor
Mayo Clinic
search

1. Study Identification

Unique Protocol Identification Number
NCT00587730
Brief Title
Attenuation Corrected Cardiac SPECT Using the GE Hawkeye Camera System
Acronym
Hawkeye
Official Title
Attenuation Corrected Cardiac SPECT Using the GE Hawkeye Camera System
Study Type
Interventional

2. Study Status

Record Verification Date
April 2015
Overall Recruitment Status
Terminated
Why Stopped
Recruiting or enrolling participants has halted prematurely and will not resume.
Study Start Date
July 2001 (undefined)
Primary Completion Date
August 2004 (Actual)
Study Completion Date
August 2004 (Actual)

3. Sponsor/Collaborators

Name of the Sponsor
Mayo Clinic

4. Oversight

Data Monitoring Committee
No

5. Study Description

Brief Summary
The accuracy of stress single photon emission computed tomography (SPECT) is limited by imaging artifacts, many of which are caused by soft tissue attenuation. A recent multicenter study performed by our laboratory comparing 7 commercially available attenuation correction (AC) camera systems in a cardiac phantom showed the best performance with the GE Hawkeye (a hybrid gamma camera-CT scanner) and the University of Michigan M-step (unique feature a camera orbit of 360˚ versus the usual 180˚) systems. In this study we will combine the strengths of these two systems (GE Hawkeye AC system and 360˚ camera orbit) to test the accuracy of this imaging system in a population of 400 consecutive patients undergoing clinically indicated stress SPECT. These patients will undergo SPECT imaging both with conventional methodology and the GE Hawkeye system. The conventional study will be interpreted and reported in the usual clinical fashion. The GE Hawkeye images will be interpreted independently by 2 observers blinded to the results of conventional imaging and will not be reported clinically. The primary study hypothesis is that AC will substantially reduce attenuation artifacts (mild fixed defects) without reducing the accuracy of either normal studies or myocardial infarction (MI). Clinical data and noninvasive test results (history of MI, electrocardiogram, and gated wall motion) will be used to distinguish defects which represent attenuation (false-positive) versus those due to MI (true-positive).

6. Conditions and Keywords

Primary Disease or Condition Being Studied in the Trial, or the Focus of the Study
Cardiac Disease
Keywords
heart disease, cardiac disease, chest pain, myocardial infarction, heart attack

7. Study Design

Primary Purpose
Diagnostic
Study Phase
Phase 2, Phase 3
Interventional Study Model
Single Group Assignment
Masking
None (Open Label)
Allocation
Non-Randomized
Enrollment
608 (Actual)

8. Arms, Groups, and Interventions

Arm Title
Clinical SPECT
Arm Type
Active Comparator
Arm Description
GE Hawkeye Attenuation Correction Camera is being compared to the approved clinical use SPECT camera.
Intervention Type
Device
Intervention Name(s)
GE Attenuation Corrected Hawkeye Camera
Intervention Description
GE Hawkeye AC system and 360˚ camera orbit
Primary Outcome Measure Information:
Title
The overall comparisons of the agreement between conventional SPECT imaging and the GE Hawkeye system will be completed using McNemar's test.
Time Frame
Measured/Compared at time of each scan.
Secondary Outcome Measure Information:
Title
Comparisons of categorical factors between the 2 tests will also be completed using McNemar's test, continuous factors will be completed using a paired t-test if the differences are normally distributed.
Time Frame
Measured/Compared at time of study

10. Eligibility

Sex
All
Minimum Age & Unit of Time
18 Years
Accepts Healthy Volunteers
No
Eligibility Criteria
Inclusion Criteria: Patients referred to the Charlton Nuclear Cardiology Laboratory for stress Tc-99m sestamibi SPECT Exclusion criteria: Prior PTCA or CABG Left bundle branch block (LBBB) or paced ventricular rhythm Clinically significant valvular heart disease Hypertrophic or idiopathic dilated cardiomyopathy Atrial fibrillation or frequent atrial or ventricular ectopy (defined as >20% ectopic beats History of MI ECG evidence of MI Chest circumference >55 inches
Overall Study Officials:
First Name & Middle Initial & Last Name & Degree
Todd D Miller, MD
Organizational Affiliation
Mayo Clinic
Official's Role
Principal Investigator
Facility Information:
Facility Name
Mayo Clinic
City
Rochester
State/Province
Minnesota
ZIP/Postal Code
55905
Country
United States

12. IPD Sharing Statement

Learn more about this trial

Attenuation Corrected Cardiac SPECT Using the GE Hawkeye Camera System

We'll reach out to this number within 24 hrs