Comparison of Rotating vs. Fixed Platform of the COLUMBUS Knee Prosthesis
Primary Purpose
Osteoarthritis, Rheumatoid Arthritis, Post-traumatic; Arthrosis
Status
Completed
Phase
Phase 4
Locations
Germany
Study Type
Interventional
Intervention
Total Knee Arthroplasty
Sponsored by

About this trial
This is an interventional treatment trial for Osteoarthritis focused on measuring Prosthesis Design, Range of Motion, Articular, Arthroplasty, Replacement, Knee
Eligibility Criteria
Inclusion Criteria:
- Indication for elective TKA
- agreement to participate in this study
- Patient age between 40 and 90 years
Exclusion Criteria:
- Malalignment of the knee to be operated of more than 20° varus or 15° valgus
- Former operations on the concerned knee (except diagnostic or therapeutic arthroscopy with only meniscus refixation or cartilage smoothing)
- Joint replacement of another joint of the same leg
- Infections in the operated joint during the follow-up period
- Thromboses during the follow-up period
- Preoperative classification according to ASA 4, 5 or 6
Sites / Locations
- Frank Lampe, MD
Arms of the Study
Arm 1
Arm 2
Arm Type
Experimental
Active Comparator
Arm Label
1
2
Arm Description
Columbus Knee Prosthesis with rotating Platform
Columbus Knee Prosthesis with fixed platform
Outcomes
Primary Outcome Measures
Knee Society Score
Secondary Outcome Measures
Oxford Score
Range of Motion
Full Information
1. Study Identification
Unique Protocol Identification Number
NCT00822640
Brief Title
Comparison of Rotating vs. Fixed Platform of the COLUMBUS Knee Prosthesis
Official Title
Clinical Outcome With Attention to Functional Results One Year After Fixed or Mobile Bearing Total Knee Replacement in a Randomized Controlled Trial
Study Type
Interventional
2. Study Status
Record Verification Date
May 2013
Overall Recruitment Status
Completed
Study Start Date
March 2004 (undefined)
Primary Completion Date
June 2007 (Actual)
Study Completion Date
July 2008 (Actual)
3. Sponsor/Collaborators
Name of the Sponsor
Aesculap AG
4. Oversight
Data Monitoring Committee
No
5. Study Description
Brief Summary
A population of 100 patients randomised to rotating and fixed PE inlays in the Columbus knee prosthesis received a navigated TKR. Knee Society Score as primary endpoint, Oxford Score, and postoperative ROM after one year will be compared.
Detailed Description
Mobile bearing tibial platform designs are advocated to improve functional results of total knee replacement (TKR), and to reduce wear in the longer term. This study investigates short term functional results with two patient groups who are systematically different in the fixed or mobile tibial bearing only.
Methods: 100 knees in 97 patients are stratified according to age and gender and randomized into two groups fixed bearing (FB) with 52 knees and mobile bearing (MB) with 48 knees. All receive the same posterior cruciate retaining implant but the tibial tray and bearing (B. Braun Aesculap Columbus CR and RP) by two experienced surgeons and follow an identical rehabilitation regime. Physical examinations are performed in a double-blinded manner before the operation and three, six and twelve months thereafter, using the Oxford and Knee Society scoring systems.
6. Conditions and Keywords
Primary Disease or Condition Being Studied in the Trial, or the Focus of the Study
Osteoarthritis, Rheumatoid Arthritis, Post-traumatic; Arthrosis
Keywords
Prosthesis Design, Range of Motion, Articular, Arthroplasty, Replacement, Knee
7. Study Design
Primary Purpose
Treatment
Study Phase
Phase 4
Interventional Study Model
Parallel Assignment
Masking
ParticipantOutcomes Assessor
Allocation
Randomized
Enrollment
100 (Actual)
8. Arms, Groups, and Interventions
Arm Title
1
Arm Type
Experimental
Arm Description
Columbus Knee Prosthesis with rotating Platform
Arm Title
2
Arm Type
Active Comparator
Arm Description
Columbus Knee Prosthesis with fixed platform
Intervention Type
Device
Intervention Name(s)
Total Knee Arthroplasty
Other Intervention Name(s)
Columbus Knee Prosthesis
Intervention Description
All patients receive the same posterior cruciate retaining implant but the tibial tray and bearing (B. Braun Aesculap Columbus CR and RP) by two experienced surgeons and will follow an identical rehabilitation regime.
Primary Outcome Measure Information:
Title
Knee Society Score
Time Frame
12 Months
Secondary Outcome Measure Information:
Title
Oxford Score
Time Frame
12
Title
Range of Motion
Time Frame
12 Months
10. Eligibility
Sex
All
Minimum Age & Unit of Time
40 Years
Maximum Age & Unit of Time
90 Years
Accepts Healthy Volunteers
No
Eligibility Criteria
Inclusion Criteria:
Indication for elective TKA
agreement to participate in this study
Patient age between 40 and 90 years
Exclusion Criteria:
Malalignment of the knee to be operated of more than 20° varus or 15° valgus
Former operations on the concerned knee (except diagnostic or therapeutic arthroscopy with only meniscus refixation or cartilage smoothing)
Joint replacement of another joint of the same leg
Infections in the operated joint during the follow-up period
Thromboses during the follow-up period
Preoperative classification according to ASA 4, 5 or 6
Overall Study Officials:
First Name & Middle Initial & Last Name & Degree
Frank Lampe, MD
Organizational Affiliation
Schön Kliniken Klinikum Eilbek
Official's Role
Principal Investigator
Facility Information:
Facility Name
Frank Lampe, MD
City
Hamburg
ZIP/Postal Code
22081
Country
Germany
12. IPD Sharing Statement
Citations:
PubMed Identifier
11451131
Citation
Buechel FF Sr, Buechel FF Jr, Pappas MJ, D'Alessio J. Twenty-year evaluation of meniscal bearing and rotating platform knee replacements. Clin Orthop Relat Res. 2001 Jul;(388):41-50. doi: 10.1097/00003086-200107000-00008.
Results Reference
background
PubMed Identifier
12439236
Citation
Buechel FF Sr. Long-term followup after mobile-bearing total knee replacement. Clin Orthop Relat Res. 2002 Nov;(404):40-50. doi: 10.1097/00003086-200211000-00008.
Results Reference
background
PubMed Identifier
10819281
Citation
Callaghan JJ, Squire MW, Goetz DD, Sullivan PM, Johnston RC. Cemented rotating-platform total knee replacement. A nine to twelve-year follow-up study. J Bone Joint Surg Am. 2000 May;82(5):705-11.
Results Reference
background
PubMed Identifier
11716386
Citation
Callaghan JJ. Mobile-bearing knee replacement: clinical results: a review of the literature. Clin Orthop Relat Res. 2001 Nov;(392):221-5. doi: 10.1097/00003086-200111000-00027.
Results Reference
background
PubMed Identifier
11372345
Citation
Callaghan JJ, Insall JN, Greenwald AS, Dennis DA, Komistek RD, Murray DW, Bourne RB, Rorabeck CH, Dorr LD. Mobile-bearing knee replacement: concepts and results. Instr Course Lect. 2001;50:431-49.
Results Reference
background
PubMed Identifier
12763437
Citation
Catani F, Benedetti MG, De Felice R, Buzzi R, Giannini S, Aglietti P. Mobile and fixed bearing total knee prosthesis functional comparison during stair climbing. Clin Biomech (Bristol, Avon). 2003 Jun;18(5):410-8. doi: 10.1016/s0268-0033(03)00044-5.
Results Reference
background
PubMed Identifier
12468843
Citation
Chiu KY, Ng TP, Tang WM, Lam P. Bilateral total knee arthroplasty: One mobile-bearing and one fixed-bearing. J Orthop Surg (Hong Kong). 2001 Jun;9(1):45-50. doi: 10.1177/230949900100900109.
Results Reference
background
PubMed Identifier
12439239
Citation
Emerson RH Jr, Hansborough T, Reitman RD, Rosenfeldt W, Higgins LL. Comparison of a mobile with a fixed-bearing unicompartmental knee implant. Clin Orthop Relat Res. 2002 Nov;(404):62-70. doi: 10.1097/00003086-200211000-00011.
Results Reference
background
PubMed Identifier
11605289
Citation
Grodzki T, Haak H, Behrendt R, Merk H, Krauspe R. [Prospective randomized comparative study of early functional outcome of 2 knee joint endoprosthesis systems--rotation plateau versus fixed polyethylene inlay]. Z Orthop Ihre Grenzgeb. 2001 Sep-Oct;139(5):393-6. doi: 10.1055/s-2001-17980. Erratum In: Z Orthop Ihre Grenzgeb 2002 Jul-Aug;140(4):460. Behrent R [corrected to Behrendt R]. German.
Results Reference
background
PubMed Identifier
11716371
Citation
Kim YH, Kook HK, Kim JS. Comparison of fixed-bearing and mobile-bearing total knee arthroplasties. Clin Orthop Relat Res. 2001 Nov;(392):101-15. doi: 10.1097/00003086-200111000-00013.
Results Reference
background
PubMed Identifier
12585579
Citation
Price AJ, Rees JL, Beard D, Juszczak E, Carter S, White S, de Steiger R, Dodd CA, Gibbons M, McLardy-Smith P, Goodfellow JW, Murray DW. A mobile-bearing total knee prosthesis compared with a fixed-bearing prosthesis. A multicentre single-blind randomised controlled trial. J Bone Joint Surg Br. 2003 Jan;85(1):62-7. doi: 10.1302/0301-620x.85b1.13233.
Results Reference
background
PubMed Identifier
11730328
Citation
Vertullo CJ, Easley ME, Scott WN, Insall JN. Mobile bearings in primary knee arthroplasty. J Am Acad Orthop Surg. 2001 Nov-Dec;9(6):355-64. doi: 10.5435/00124635-200111000-00001.
Results Reference
background
PubMed Identifier
24929659
Citation
Marques CJ, Daniel S, Sufi-Siavach A, Lampe F. No differences in clinical outcomes between fixed- and mobile-bearing computer-assisted total knee arthroplasties and no correlations between navigation data and clinical scores. Knee Surg Sports Traumatol Arthrosc. 2015 Jun;23(6):1660-8. doi: 10.1007/s00167-014-3127-x. Epub 2014 Jun 15.
Results Reference
derived
Learn more about this trial
Comparison of Rotating vs. Fixed Platform of the COLUMBUS Knee Prosthesis
We'll reach out to this number within 24 hrs