Drug-eluting Balloon in Acute Myocardial Infarction (DEB-AMI)
Primary Purpose
Coronary Artery Disease, Atherosclerosis, Thrombosis
Status
Completed
Phase
Phase 2
Locations
International
Study Type
Interventional
Intervention
Drug eluting balloon
Bare metal stent
Drug eluting stent
Sponsored by
About this trial
This is an interventional treatment trial for Coronary Artery Disease
Eligibility Criteria
Inclusion Criteria:
- STEMI within 12 hours of onset of complaints
- Candidate for primary PCI with stent-implantation
- Successful thrombus aspiration defined by no angiographic signs of thrombus a the site of plaque rupture and TIMI flow more or equal 1
Exclusion Criteria:
- Unable to give written informed consent
- Diabetes and Type C- coronary lesion
- Previous PCI or CABG of infarct related vessel
- Left main stenosis more than 50%.
- Triple vessel disease with stenosis more than 50% in 3 epicardial coronary arteries
- Target vessel reference diameter less than 2.5 and more than 4.0 mm
- Target lesion length more than 25 mm
- Intolerance for aspirin or clopidogrel
- Life expectancy less than 12 months
- Women with child bearing potential
Sites / Locations
- University of Modena, Department of Cardiology
- UMC Utrecht
Arms of the Study
Arm 1
Arm 2
Arm 3
Arm Type
Experimental
Active Comparator
Active Comparator
Arm Label
1
2
3
Arm Description
Drug eluting balloon followed immediately by implantation of bare metal stent
Drug eluting stent
Bare metal stent
Outcomes
Primary Outcome Measures
Angiographic in-segment late lumen loss (expressed in millimeters) as determined by quantitative coronary analysis (QCA)
Secondary Outcome Measures
Binary restenosis using QCA
stent malapposition and re-endothelialization assessed by Optical Coherence Tomography (OCY)
coronary endothelial dysfunction after acetylcholine infusion
Clinical outcomes (death, myocardial infarction, repeated revascularization procedures)
Full Information
1. Study Identification
Unique Protocol Identification Number
NCT00856765
Brief Title
Drug-eluting Balloon in Acute Myocardial Infarction
Acronym
DEB-AMI
Official Title
Randomized Comparison of Drug Eluting Balloon/Bare Metal Stent Versus Drug Eluting Stent Versus Bare Metal Stent for the Treatment of Patients With Acute ST-elevation Myocardial Infarction
Study Type
Interventional
2. Study Status
Record Verification Date
May 2017
Overall Recruitment Status
Completed
Study Start Date
March 2009 (undefined)
Primary Completion Date
June 2011 (Actual)
Study Completion Date
November 2016 (Actual)
3. Sponsor/Collaborators
Responsible Party, by Official Title
Principal Investigator
Name of the Sponsor
UMC Utrecht
4. Oversight
Data Monitoring Committee
Yes
5. Study Description
Brief Summary
The investigators hypothesize that patients with Acute ST Elevation Myocardial Infarction may benefit from primary angioplasty with use of a drug eluting balloon/bare metal stent combination without impairing the process of normal vascular healing and endothelial function.
The goals of this study are:
To compare 6-month angiographic outcome after primary angioplasty using drug eluting balloon/bare metal stent combination versus drug eluting stent versus bare metal stent.
To compare stent apposition and stent endothelialization after primary angioplasty using drug eluting balloon/bare metal stent versus drug eluting stent versus bare metal stent.
To compare coronary endothelial function after primary angioplasty using drug eluting balloon/bare metal stent versus drug eluting stent versus bare metal stent.
6. Conditions and Keywords
Primary Disease or Condition Being Studied in the Trial, or the Focus of the Study
Coronary Artery Disease, Atherosclerosis, Thrombosis, Acute Myocardial Infarction
7. Study Design
Primary Purpose
Treatment
Study Phase
Phase 2, Phase 3
Interventional Study Model
Parallel Assignment
Masking
None (Open Label)
Allocation
Randomized
Enrollment
150 (Actual)
8. Arms, Groups, and Interventions
Arm Title
1
Arm Type
Experimental
Arm Description
Drug eluting balloon followed immediately by implantation of bare metal stent
Arm Title
2
Arm Type
Active Comparator
Arm Description
Drug eluting stent
Arm Title
3
Arm Type
Active Comparator
Arm Description
Bare metal stent
Intervention Type
Device
Intervention Name(s)
Drug eluting balloon
Other Intervention Name(s)
Dior (EuroCor)
Intervention Description
Percutaneous transluminal coronary balloon angioplasty catheter eluting paclitaxel
Intervention Type
Device
Intervention Name(s)
Bare metal stent
Other Intervention Name(s)
Magic (EuroCor)
Intervention Description
Bare metal stent
Intervention Type
Device
Intervention Name(s)
Drug eluting stent
Other Intervention Name(s)
Taxus Liberté (Boston scientific)
Intervention Description
Paclitaxel eluting stent
Primary Outcome Measure Information:
Title
Angiographic in-segment late lumen loss (expressed in millimeters) as determined by quantitative coronary analysis (QCA)
Time Frame
6 months
Secondary Outcome Measure Information:
Title
Binary restenosis using QCA
Time Frame
6 months
Title
stent malapposition and re-endothelialization assessed by Optical Coherence Tomography (OCY)
Time Frame
6 months
Title
coronary endothelial dysfunction after acetylcholine infusion
Time Frame
6 months
Title
Clinical outcomes (death, myocardial infarction, repeated revascularization procedures)
Time Frame
5 years
10. Eligibility
Sex
All
Minimum Age & Unit of Time
18 Years
Maximum Age & Unit of Time
80 Years
Accepts Healthy Volunteers
No
Eligibility Criteria
Inclusion Criteria:
STEMI within 12 hours of onset of complaints
Candidate for primary PCI with stent-implantation
Successful thrombus aspiration defined by no angiographic signs of thrombus a the site of plaque rupture and TIMI flow more or equal 1
Exclusion Criteria:
Unable to give written informed consent
Diabetes and Type C- coronary lesion
Previous PCI or CABG of infarct related vessel
Left main stenosis more than 50%.
Triple vessel disease with stenosis more than 50% in 3 epicardial coronary arteries
Target vessel reference diameter less than 2.5 and more than 4.0 mm
Target lesion length more than 25 mm
Intolerance for aspirin or clopidogrel
Life expectancy less than 12 months
Women with child bearing potential
Overall Study Officials:
First Name & Middle Initial & Last Name & Degree
Pieter Stella, MD
Organizational Affiliation
UMC Utrecht
Official's Role
Principal Investigator
Facility Information:
Facility Name
University of Modena, Department of Cardiology
City
Modena
Country
Italy
Facility Name
UMC Utrecht
City
Utrecht
ZIP/Postal Code
3584 cx
Country
Netherlands
12. IPD Sharing Statement
Citations:
PubMed Identifier
22503057
Citation
Belkacemi A, Agostoni P, Nathoe HM, Voskuil M, Shao C, Van Belle E, Wildbergh T, Politi L, Doevendans PA, Sangiorgi GM, Stella PR. First results of the DEB-AMI (drug eluting balloon in acute ST-segment elevation myocardial infarction) trial: a multicenter randomized comparison of drug-eluting balloon plus bare-metal stent versus bare-metal stent versus drug-eluting stent in primary percutaneous coronary intervention with 6-month angiographic, intravascular, functional, and clinical outcomes. J Am Coll Cardiol. 2012 Jun 19;59(25):2327-37. doi: 10.1016/j.jacc.2012.02.027. Epub 2012 Apr 11.
Results Reference
result
Learn more about this trial
Drug-eluting Balloon in Acute Myocardial Infarction
We'll reach out to this number within 24 hrs