search
Back to results

South American Abdominal Stent Graft Trial

Primary Purpose

Abdominal Aortic Aneurysm

Status
Completed
Phase
Phase 1
Locations
Chile
Study Type
Interventional
Intervention
Ovation Abdominal Stent Graft System
Sponsored by
TriVascular, Inc.
About
Eligibility
Locations
Arms
Outcomes
Full info

About this trial

This is an interventional treatment trial for Abdominal Aortic Aneurysm focused on measuring abdominal, aortic, aneurysm, AAA

Eligibility Criteria

18 Years - undefined (Adult, Older Adult)All SexesDoes not accept healthy volunteers

Inclusion Criteria:

  1. Patient is > 18 years of age
  2. Patients who are male or non-pregnant female (females of child bearing potential must have a negative pregnancy test prior to enrollment into the study)
  3. Patient has signed an Ethics Committee approved Informed Consent Form
  4. Patient is considered by the treating physician to be a candidate for elective open surgical repair of the AAA (i.e., category I, II, or III per American Society of Anesthesiology (ASA) classification; refer to Appendix III: ASA Classification System). ASA category IV patients may be enrolled provided their life expectancy is greater than 1 year.
  5. Patient has an infrarenal abdominal aortic aneurysm that meets at least one of the following:

    1. Abdominal aortic aneurysm >5.0 cm in diameter,
    2. Aneurysm that has increased in size by 0.5 cm in last 6 months,
    3. Maximum diameter of aneurysm exceeds 1.5 times the transverse dimension of an adjacent normal aortic segment.
  6. Patient has a patent iliac or femoral arteries that allow endovascular access with the TriVascular Ovation Abdominal Stent Graft System.
  7. Patient has a suitable non-aneurysmal proximal aortic neck length of ≥ 7 mm inferior to the most distal renal artery ostium.
  8. Patient has a suitable non-aneurysmal distal iliac artery length (seal zone) of ≥ 10 mm. The resultant repair should preserve patency in at least one hypogastric artery.
  9. Patient has a suitable non-aneurysmal proximal aortic neck luminal diameter between 16 and 30 mm.
  10. Patient has a suitable non-aneurysmal distal iliac luminal diameter between 8 and 20 mm.
  11. Patient meets the following anatomic criteria: the distance from the most distal renal artery to most superior internal iliac artery measurement is at least 13 cm.
  12. Patient has juxtarenal aortic neck angulation ≤ 60º if proximal neck is ≥ 10 mm and ≤ 45 if proximal neck is <10 mm.
  13. Patient must be able and willing to comply with all required follow-up exams.

Exclusion Criteria:

  1. Patient has a dissecting aneurysm.
  2. Patient has an acutely ruptured aneurysm.
  3. Patient has an acute vascular injury.
  4. Patient has need for emergent surgery.
  5. Patient has a known thoracic aortic aneurysm or dissection.
  6. Patient has a mycotic aneurysm or has an active systemic infection..
  7. Patient has unstable angina (defined as angina with a progressive increase in symptoms, new onset at rest or nocturnal angina, or onset of prolonged angina)
  8. Patient has had a myocardial infarction (MI) and/or stroke (CVA) within the past 6 months.
  9. Patient has a major surgical or interventional procedure planned ≤ 30 days of the AAA repair.
  10. Patient has history of connective tissue disease (e.g., Marfan's or Ehler's-Danlos syndrome).
  11. Patient has history of bleeding disorders or refuses blood transfusions.
  12. Patient has dialysis dependent renal failure or baseline serum creatinine level >2.0 mg/dl.
  13. Patient has a known hypersensitivity or contraindication to anticoagulation or contrast media that is not amenable to pre-treatment.
  14. Patient has a known allergy or intolerance to polytetrafluoroethylene (PTFE), PEG-based polymers, fluorinated ethylene-propylene (FEP) or nitinol.
  15. Patient has a body habitus that would inhibit X-ray visualization of the aorta
  16. Patient has a limited life expectancy of less than 1 year
  17. Patient is currently participating in an investigational device or drug clinical trial.
  18. Patient has other medical, social or psychological conditions that, in the opinion of the investigator, preclude them from receiving the pre-treatment, required treatment, and post-treatment procedures and evaluations.

Sites / Locations

  • Pontificia Universidad Catolica de Chile

Arms of the Study

Arm 1

Arm Type

Other

Arm Label

Ovation Abdominal Stent Graft System

Arm Description

Endovascular implant of Abdominal Aortic Aneurysm Stent Graft

Outcomes

Primary Outcome Measures

A Clinical Study to Evaluate the Safety and Performance of the TriVascular Ovation Abdominal Stent Graft System

Secondary Outcome Measures

Full Information

First Posted
March 4, 2010
Last Updated
June 3, 2021
Sponsor
TriVascular, Inc.
search

1. Study Identification

Unique Protocol Identification Number
NCT01082185
Brief Title
South American Abdominal Stent Graft Trial
Official Title
A Clinical Study to Evaluate the Safety and Performance of the TriVascular Modular Abdominal Stent Graft System
Study Type
Interventional

2. Study Status

Record Verification Date
June 2021
Overall Recruitment Status
Completed
Study Start Date
November 2009 (Actual)
Primary Completion Date
March 3, 2011 (Actual)
Study Completion Date
February 3, 2016 (Actual)

3. Sponsor/Collaborators

Responsible Party, by Official Title
Sponsor
Name of the Sponsor
TriVascular, Inc.

4. Oversight

Data Monitoring Committee
Yes

5. Study Description

Brief Summary
A Clinical Study to Evaluate the Safety and Performance of the TriVascular Ovation Abdominal Stent Graft System
Detailed Description
This study is a prospective, non-randomized multi-center clinical evaluation of the safety and performance of the TriVascular Modular Abdominal Stent Graft System when used in the treatment of subjects with abdominal aortic aneurysms (AAA).

6. Conditions and Keywords

Primary Disease or Condition Being Studied in the Trial, or the Focus of the Study
Abdominal Aortic Aneurysm
Keywords
abdominal, aortic, aneurysm, AAA

7. Study Design

Primary Purpose
Treatment
Study Phase
Phase 1
Interventional Study Model
Single Group Assignment
Masking
None (Open Label)
Allocation
N/A
Enrollment
20 (Actual)

8. Arms, Groups, and Interventions

Arm Title
Ovation Abdominal Stent Graft System
Arm Type
Other
Arm Description
Endovascular implant of Abdominal Aortic Aneurysm Stent Graft
Intervention Type
Device
Intervention Name(s)
Ovation Abdominal Stent Graft System
Intervention Description
Endovascular implant of Abdominal Aortic Aneurysm Stent Graft
Primary Outcome Measure Information:
Title
A Clinical Study to Evaluate the Safety and Performance of the TriVascular Ovation Abdominal Stent Graft System
Time Frame
30-Days

10. Eligibility

Sex
All
Minimum Age & Unit of Time
18 Years
Accepts Healthy Volunteers
No
Eligibility Criteria
Inclusion Criteria: Patient is > 18 years of age Patients who are male or non-pregnant female (females of child bearing potential must have a negative pregnancy test prior to enrollment into the study) Patient has signed an Ethics Committee approved Informed Consent Form Patient is considered by the treating physician to be a candidate for elective open surgical repair of the AAA (i.e., category I, II, or III per American Society of Anesthesiology (ASA) classification; refer to Appendix III: ASA Classification System). ASA category IV patients may be enrolled provided their life expectancy is greater than 1 year. Patient has an infrarenal abdominal aortic aneurysm that meets at least one of the following: Abdominal aortic aneurysm >5.0 cm in diameter, Aneurysm that has increased in size by 0.5 cm in last 6 months, Maximum diameter of aneurysm exceeds 1.5 times the transverse dimension of an adjacent normal aortic segment. Patient has a patent iliac or femoral arteries that allow endovascular access with the TriVascular Ovation Abdominal Stent Graft System. Patient has a suitable non-aneurysmal proximal aortic neck length of ≥ 7 mm inferior to the most distal renal artery ostium. Patient has a suitable non-aneurysmal distal iliac artery length (seal zone) of ≥ 10 mm. The resultant repair should preserve patency in at least one hypogastric artery. Patient has a suitable non-aneurysmal proximal aortic neck luminal diameter between 16 and 30 mm. Patient has a suitable non-aneurysmal distal iliac luminal diameter between 8 and 20 mm. Patient meets the following anatomic criteria: the distance from the most distal renal artery to most superior internal iliac artery measurement is at least 13 cm. Patient has juxtarenal aortic neck angulation ≤ 60º if proximal neck is ≥ 10 mm and ≤ 45 if proximal neck is <10 mm. Patient must be able and willing to comply with all required follow-up exams. Exclusion Criteria: Patient has a dissecting aneurysm. Patient has an acutely ruptured aneurysm. Patient has an acute vascular injury. Patient has need for emergent surgery. Patient has a known thoracic aortic aneurysm or dissection. Patient has a mycotic aneurysm or has an active systemic infection.. Patient has unstable angina (defined as angina with a progressive increase in symptoms, new onset at rest or nocturnal angina, or onset of prolonged angina) Patient has had a myocardial infarction (MI) and/or stroke (CVA) within the past 6 months. Patient has a major surgical or interventional procedure planned ≤ 30 days of the AAA repair. Patient has history of connective tissue disease (e.g., Marfan's or Ehler's-Danlos syndrome). Patient has history of bleeding disorders or refuses blood transfusions. Patient has dialysis dependent renal failure or baseline serum creatinine level >2.0 mg/dl. Patient has a known hypersensitivity or contraindication to anticoagulation or contrast media that is not amenable to pre-treatment. Patient has a known allergy or intolerance to polytetrafluoroethylene (PTFE), PEG-based polymers, fluorinated ethylene-propylene (FEP) or nitinol. Patient has a body habitus that would inhibit X-ray visualization of the aorta Patient has a limited life expectancy of less than 1 year Patient is currently participating in an investigational device or drug clinical trial. Patient has other medical, social or psychological conditions that, in the opinion of the investigator, preclude them from receiving the pre-treatment, required treatment, and post-treatment procedures and evaluations.
Overall Study Officials:
First Name & Middle Initial & Last Name & Degree
Francisco Valdes, MD
Organizational Affiliation
Pontificia Universidad Catolica de Chile
Official's Role
Principal Investigator
Facility Information:
Facility Name
Pontificia Universidad Catolica de Chile
City
Santiago
Country
Chile

12. IPD Sharing Statement

Citations:
PubMed Identifier
23978572
Citation
Mehta M, Valdes FE, Nolte T, Mishkel GJ, Jordan WD, Gray B, Eskandari MK, Botti C; A Pivotal Clinical Study to Evaluate the Safety and Effectiveness of the Ovation Abdominal Stent Graft System Investigators. One-year outcomes from an international study of the Ovation Abdominal Stent Graft System for endovascular aneurysm repair. J Vasc Surg. 2014 Jan;59(1):65-73.e1-3. doi: 10.1016/j.jvs.2013.06.065. Epub 2013 Aug 24.
Results Reference
derived

Learn more about this trial

South American Abdominal Stent Graft Trial

We'll reach out to this number within 24 hrs