EnSeal Efficacy and Bursting Pressure in Human Vessels

Primary Purpose

Colon and Rectal Diseases

Status
Withdrawn
Phase
Not Applicable
Locations
United States
Study Type
Interventional
Intervention
EnSeal Device
Sponsored by
University of Illinois at Chicago
About
Eligibility
Locations
Outcomes
Full info

About this trial

This is an interventional other trial for Colon and Rectal Diseases focused on measuring vessel ligation, colon resection

Eligibility Criteria

21 Years - 90 Years (Adult, Older Adult)All SexesDoes not accept healthy volunteers

Inclusion Criteria:

  • Include patients who will be undergoing resection of part of their colon that will require dividing the colonic vessels. The use of the resected surgical specimens is included our project.

Exclusion Criteria:

  • Patients who do not meet the the inclusion criteria.

Sites / Locations

  • University Of Illinois Medical Center at Chicago

Outcomes

Primary Outcome Measures

EnSeal Efficacy and Bursting Pressures in Human Vessels
Demonstrate that the bursting pressures in large vessels (IMA, IMV) sealed in colectomy of human patients are sufficiently high. Using the EnSeal device on larger vessels, the investigators believe, would further reduce operating time, blood loss, and hasten post-operative recovery from less tissue manipulation.

Secondary Outcome Measures

Full Information

First Posted
March 9, 2011
Last Updated
January 29, 2020
Sponsor
University of Illinois at Chicago
Collaborators
Ethicon Endo-Surgery
search

1. Study Identification

Unique Protocol Identification Number
NCT01312246
Brief Title
EnSeal Efficacy and Bursting Pressure in Human Vessels
Official Title
EnSeal Efficacy and Bursting Pressure in Human Vessels
Study Type
Interventional

2. Study Status

Record Verification Date
January 2020
Overall Recruitment Status
Withdrawn
Study Start Date
April 2011 (undefined)
Primary Completion Date
December 2012 (Anticipated)
Study Completion Date
December 2012 (Anticipated)

3. Sponsor/Collaborators

Name of the Sponsor
University of Illinois at Chicago
Collaborators
Ethicon Endo-Surgery

4. Oversight

Data Monitoring Committee
No

5. Study Description

Brief Summary
In this study the investigators will include adult patients who are not part of a vulnerable patient population. Inclusion criteria include patients who will be undergoing resection of part of their colon that will require dividing the IMA. The investigators will use the resected surgical specimens for our project. The investigators will use the EnSeal on all major vessels in our procedure. The investigators will use the EnSeal 5 mm round head model. Due to the nature of the project, we will apply for IRB approval prior to beginning our research. The investigators plan to include 60 total patients in the study, 30 at the University of Illinois and 30 at Lutheran General Hospital. Prior to resection, the investigators will use a sterile caliper to take an in-vivo measurement of the IMA and IMV. Immediately after resection, the investigators will remove the sealed proximal end of the IMA and the 3 cm distal to it from the surgical specimen. The investigators will similarly prepare the IMV. The investigators will inspect our vessels for any iatrogenic traumatic tears. If the vessels are suitable, the investigators will then gentle apply manual traction to remove any blood or clots within the lumen. The investigators will measure the outer diameter of the vessels using a digital caliper. If there are small branches, the investigators will tie them off with suture. The unsealed end will then be attached to the burst pressure tester with suture and it will be tested for the bursting pressure. The device measures pressure continuously as it infuses the segment with normal saline at a steady rate (50 ml/hr). A leak will be determined by a decrease in intra-luminal pressure of 100 mm Hg or a visible leak. A failure to seal the vessels will be determined by a bursting pressure of less than 100 mm Hg. It should be noted that each section would only be pressure-tested once. All of our data will be collected on the enclosed data sheet we have created for use in this protocol. The investigators will then place the vessels with the original surgical specimen where it will be submitted for routine pathological examination of surgical specimens. Twenty five specimens at each site will undergo the testing, whereas 5 specimens will be sent to pathology without testing. Our pathologist will analyze the submitted specimen for extent of seal, disruption of vessel smooth muscle, gas bubbles, and will stain for elastin to analyze the disruption in the vessel wall. In addition, the seal will be measured and we will obtain digital images. The specimens submitted for pathology will be 5 burst specimens as well as 5 un-burst specimens taken from the pool of 25 patients at UIC. For our human component, the investigators have estimated the standard deviation and width of the confidence interval to be 100 mm Hg each. With a 95% confidence level, the investigators expect to require 16 measurements for human specimens from 16 patients although the investigators will use 50 patients to allow for errors in obtaining pressures. Our timeline for the completion of the projects is 6 months. The investigators plan on being able to complete the human burst pressure testing within 6 months.
Detailed Description
Introduction Multiple new cautery devices are used to perform quicker and safer surgeries. These devices are able to seal vessels without need of ties or adjunct maneuvers and produce a minimal thermal spread to adjacent tissues. We have found that the EnSeal is a reliable, versatile, and effective device for sealing vessels. Currently, the EnSeal is approved for vessels as large as 7 mm in diameter. We believe, based on prior clinical experience, that the EnSeal can safely seal vessels of a larger diameter. Current data shows that the bursting pressures obtained in 7 mm vessels are five times the physiological normal pressure in animal models.1, 2 We have demonstrated that all of the mesenteric vessels encountered in a human colectomy can be safely divided with EnSeal. However, neither we nor other researchers have measured the bursting pressure of these seals in human patients. We propose to examine the bursting pressures of vessels taken in colectomies in an ex-vivo fashion. After we use the EnSeal to divide the inferior mesenteric artery at its origin, we will then use assess the bursting pressure of this seal. We will similarly assess the inferior mesenteric vein. We will measure the diameter of the vessels both in-vivo and ex-vivo. Finally, we will conduct histopathological examination of the sealed vessels to determine the effects of the EnSeal device on the structure of the vessels. Background With the increased preference for laparoscopic surgery, new instruments are needed to safely replicate and, where possible, improve upon the techniques used in open surgery. Visualization is eminently important and dependent on multiple factors, including bleeding and smoke from coagulation and cautery. Therefore, there is a high demand for devices that can safely coagulate tissue with low heat and little smoke. Resection of tissues in a safe and haemostatic fashion in laparoscopic colorectal surgery depends upon good control of mesenteric vessels. Ideally, the thermal spread should be minimal and travel in a predictable pattern. Various new devices have been created and used for the purposes of vessel sealing, with some of the more popular being Ligasure (Valleylab), Harmonic (Ethicon), Gyrus (Gyrus ACMI), and EnSeal (Ethicon). Multi-purpose instruments are preferable because the surgeon can avoid frequent exchange of instruments and thus reduce operative time. The previously mentioned vessel-sealing devices work with two jaws and can also be used to manipulate some tissue. Of particular interest to our group of colorectal surgeons is the finding that along with decreased operative time, these devices have been shown to contribute to decreased blood loss during laparoscopic colectomies.3 These modern vessel-sealing devices work by varying methods. The Harmonic Scalpel is an ultrasonic shear that breaks hydrogen bonds and cause tissue coagulation and vessel sealing.4 The Ligasure device works by coagulating the tissue in the jaws of the device with high-current/low-voltage flow and then using high-pressure jaws to seal it.5 The nano-particle technology of the EnSeal device aims to lower the temperature of the instrument to minimize heat transfer to adjacent tissue and allows for different temperatures within different parts of the jaws. It turns off when collagen denatures, at approximately 100 degrees Celsius.6 These sealing systems have been widely used in many surgical disciplines and surgeons continue to try to find new uses for these innovative devices. They have been compared to conventional methods such as clips and ties and found to be as effective when applied properly.7 The Gyrus PK system has been used in urological and robotic surgery.8, 9 The Harmonic Scalpel has been used in major abdominal operations and also in otolaryngology operations.10, 11 Ligasure has perhaps been the most widely adopted and is used in gynecological, otolaryngology, and colorectal specialties.12-15 The EnSeal device is newer than the others and while it is gaining popularity in its use, it has not been as extensively studied at this time. Currently, the USA FDA has approved the EnSeal device for vessels up to 7 mm in diameter. This is equal or greater to other vessel sealing systems that are widely used such as Ligasure (7 mm) and Harmonic Scalpel (5 mm). Porcine studies done by SurgRx as well as research groups from Cleveland Clinic - FL and Carolinas Medical Center demonstrate the safety of this device in its approved size range when compared to other devices. In these studies, they find that the EnSeal has significantly higher burst pressures on sealed vessels than other sealing systems (678 mm Hg for EnSeal vs 489 mm Hg for Ligasure) or that there is no statistical difference, but that it seals at supra-physiologic pressures (891 mm Hg EnSeal vs 884 mm Hg Ligasure).1, 2 These measurements are obtained by securing the open end of a vessel to a device that fills the lumen with fluid. Once the seal on the other end bursts, the machine records the final pressure reading within the lumen of the vessel. Other notable findings of the EnSeal include less adventitial damage to the vessels on histopathologic evaluation and minimal failure rates (only 1/39 vessels failed to seal).1, 2 A study completed from Turkey used EnSeal on rat liver parenchyma and compared it to Ligasure and conventional methods for liver resection. Sahin and colleagues found that EnSeal was at least as effective as conventional techniques and that there was less inflammation and damage due to thermal spread to the rat liver parenchyma when compared to Ligasure.16 In a comparison of two ultrasonic devices on human vessels, Ching found that veins have a decreasing burst pressure as the diameter of the vessels increase.17 These burst pressures are much lower than what is reported in porcine arteries. This finding makes it important to determine the seal bursting pressure in human vessels so that the relationship between experimental values in porcine models can be clinically correlated. Previous studies have analyzed the histopathologic effect of the EnSeal device on the blood vessels.2 We will also do an analysis of human tissue. In our practice, we routinely use the EnSeal device to seal the ileocolic vessels and the inferior mesenteric artery and vein (IMA, IMV). Data with good evidence of the diameter (external or internal) of the inferior mesenteric artery is not widely available. However, we were able to find some data that can provide a little information. In a study by Yekeler et al, the investigators used ultrasound technology to determine the internal diameter of the superior mesenteric artery (SMA). In their study, they found that in healthy patients the internal diameter average was 5.8 mm. Among their findings is a pattern of significantly increased internal diameter in patients with active inflammation compared to patients with quiescent disease.18 We have long suspected that in tissue experiencing acute or chronic inflammation the feeding vessel will be larger; their evidence supports this hypothesis. In a very small study examining the use of the IMA for coronary artery bypass grafts, researchers harvested two IMAs and measured one of them. This artery had a 4 mm diameter at its origin. The IMA is smaller than the SMA in the vast majority of patients. Therefore, the findings by Shatapathy are consistent with this expectation.19 In our practice, we have gravitated towards the EnSeal. We find that it is effective, reliable and its versatility is evidenced by its use as a grasper, dissector, scissors and vessel and soft-tissue sealer. The nano-particles that are within the jaws of the device to regulate current and heat distribution serve to protect the adjacent tissue from thermal injury. Such injuries from other devices have been documented and often present with late and serious complications.21 As part of our normal surgical practice, we use the EnSeal to divide and seal the inferior mesenteric artery and vein when their resection is indicated. In our experience with this device, it has a low failure rate. We have not experienced any post-operative bleeding that requires transfusion or re-operation. Even though we believe that the majority of IMAs we encounter are below the 7 mm size, most surgeons do not feel comfortable using the EnSeal to seal this vessel and will use staplers to divide them. We intend to demonstrate that the bursting pressures in large vessels (IMA, IMV) sealed in colectomy of human patients are sufficiently high. Using the EnSeal device on larger vessels, we believe, would further reduce operating time, blood loss, and hasten post-operative recovery from less tissue manipulation. Methods In this study we will include adult patients who are not part of a vulnerable patient population. Inclusion criteria include patients who will be undergoing resection of part of their colon that will require dividing the IMA. We will use the resected surgical specimens for our project. We will use the EnSeal on all major vessels in our procedure. We will use the EnSeal 5 mm round head model. Due to the nature of the project, we will apply for IRB approval prior to beginning our research. We plan to include 60 total patients in the study, 30 at the University of Illinois and 30 at Lutheran General Hospital. Prior to resection, we will use a sterile caliper to take an in-vivo measurement of the IMA and IMV. Immediately after resection, we will remove the sealed proximal end of the IMA and the 3 cm distal to it from the surgical specimen. We will similarly prepare the IMV. We will inspect our vessels for any iatrogenic traumatic tears. If the vessels are suitable, we will then gentle apply manual traction to remove any blood or clots within the lumen. We will measure the outer diameter of the vessels using a digital caliper. If there are small branches, we will tie them off with suture. The unsealed end will then be attached to the burst pressure tester with suture and it will be tested for the bursting pressure. The device measures pressure continuously as it infuses the segment with normal saline at a steady rate (50 ml/hr). A leak will be determined by a decrease in intra-luminal pressure of 100 mm Hg or a visible leak. A failure to seal the vessels will be determined by a bursting pressure of less than 100 mm Hg. It should be noted that each section would only be pressure-tested once. All of our data will be collected on the enclosed data sheet we have created for use in this protocol. We will then place the vessels with the original surgical specimen where it will be submitted for routine pathological examination of surgical specimens. Twenty five specimens at each site will undergo the testing, whereas 5 specimens will be sent to pathology without testing. Our pathologist will analyze the submitted specimen for extent of seal, disruption of vessel smooth muscle, gas bubbles, and will stain for elastin to analyze the disruption in the vessel wall. In addition, the seal will be measured and we will obtain digital images. The specimens submitted for pathology will be 5 burst specimens as well as 5 un-burst specimens taken from the pool of 25 patients at UIC. For our human component, we have estimated the standard deviation and width of the confidence interval to be 100 mm Hg each. With a 95% confidence level, we expect to require 16 measurements for human specimens from 16 patients although we will use 50 patients to allow for errors in obtaining pressures. Our timeline for the completion of the projects is 6 months. We plan on being able to complete the human burst pressure testing within 6 months. Budget The budget PAF number has been included in this study. The budget also includes moneys for a concurrent study involving porcine vessels. We will harvest these blood vessels after pigs used for other research purposes are euthanized. I have included a letter from the BRL stating that this study does not require approval because we are using animals that were used for other purposes.

6. Conditions and Keywords

Primary Disease or Condition Being Studied in the Trial, or the Focus of the Study
Colon and Rectal Diseases
Keywords
vessel ligation, colon resection

7. Study Design

Primary Purpose
Other
Study Phase
Not Applicable
Interventional Study Model
Single Group Assignment
Masking
None (Open Label)
Allocation
N/A
Enrollment
0 (Actual)

8. Arms, Groups, and Interventions

Intervention Type
Device
Intervention Name(s)
EnSeal Device
Other Intervention Name(s)
EnSeal Device- Ethicon Endo Surgery
Intervention Description
measurement of bursting pressure of colonic vessels after using the EnSeal Device
Primary Outcome Measure Information:
Title
EnSeal Efficacy and Bursting Pressures in Human Vessels
Description
Demonstrate that the bursting pressures in large vessels (IMA, IMV) sealed in colectomy of human patients are sufficiently high. Using the EnSeal device on larger vessels, the investigators believe, would further reduce operating time, blood loss, and hasten post-operative recovery from less tissue manipulation.
Time Frame
21 months

10. Eligibility

Sex
All
Minimum Age & Unit of Time
21 Years
Maximum Age & Unit of Time
90 Years
Accepts Healthy Volunteers
No
Eligibility Criteria
Inclusion Criteria: Include patients who will be undergoing resection of part of their colon that will require dividing the colonic vessels. The use of the resected surgical specimens is included our project. Exclusion Criteria: Patients who do not meet the the inclusion criteria.
Overall Study Officials:
First Name & Middle Initial & Last Name & Degree
Leela M Prasad, MD
Organizational Affiliation
University of Illinois at Chicago
Official's Role
Principal Investigator
Facility Information:
Facility Name
University Of Illinois Medical Center at Chicago
City
Chicago
State/Province
Illinois
ZIP/Postal Code
60612
Country
United States

12. IPD Sharing Statement

Citations:
PubMed Identifier
18483824
Citation
Newcomb WL, Hope WW, Schmelzer TM, Heath JJ, Norton HJ, Lincourt AE, Heniford BT, Iannitti DA. Comparison of blood vessel sealing among new electrosurgical and ultrasonic devices. Surg Endosc. 2009 Jan;23(1):90-6. doi: 10.1007/s00464-008-9932-x. Epub 2008 May 16.
Results Reference
background
PubMed Identifier
18097720
Citation
Person B, Vivas DA, Ruiz D, Talcott M, Coad JE, Wexner SD. Comparison of four energy-based vascular sealing and cutting instruments: A porcine model. Surg Endosc. 2008 Feb;22(2):534-8. doi: 10.1007/s00464-007-9619-8. Epub 2007 Dec 20.
Results Reference
background
PubMed Identifier
17287913
Citation
Campagnacci R, de Sanctis A, Baldarelli M, Rimini M, Lezoche G, Guerrieri M. Electrothermal bipolar vessel sealing device vs. ultrasonic coagulating shears in laparoscopic colectomies: a comparative study. Surg Endosc. 2007 Sep;21(9):1526-31. doi: 10.1007/s00464-006-9143-2. Epub 2007 Feb 8.
Results Reference
background
PubMed Identifier
17365677
Citation
Entezari K, Hoffmann P, Goris M, Peltier A, Van Velthoven R. A review of currently available vessel sealing systems. Minim Invasive Ther Allied Technol. 2007;16(1):52-7. doi: 10.1080/13645700601181414.
Results Reference
background
PubMed Identifier
16999627
Citation
Gilleran JP, Thaly RK, Chernoff AM. Rapid communication: bipolar PlasmaKinetic transurethral resection of the prostate: reliable training vehicle for today's urology residents. J Endourol. 2006 Sep;20(9):683-7. doi: 10.1089/end.2006.20.683.
Results Reference
background
PubMed Identifier
18266601
Citation
Meehan JJ. The robotic Gyrus PK: a new articulating thermal sealing device and a preliminary series report. J Laparoendosc Adv Surg Tech A. 2008 Feb;18(1):183-5. doi: 10.1089/lap.2007.0179.
Results Reference
background
PubMed Identifier
18282338
Citation
Kang SK, Kunanandam T, Clark L. Prospective, case-control study of surgical efficiency of ultrasonic shear ('harmonic scalpel') thyroidectomy compared with conventional thyroidectomy. J Laryngol Otol. 2008 Nov;122(11):1194-6. doi: 10.1017/S0022215107001661. Epub 2008 Feb 19.
Results Reference
background
PubMed Identifier
17765762
Citation
Lachanas VA, Hajiioannou JK, Karatzias GT, Filios D, Koutsias S, Mourgelas C. Comparison of LigaSure vessel sealing system, harmonic scalpel, and cold knife tonsillectomy. Otolaryngol Head Neck Surg. 2007 Sep;137(3):385-9. doi: 10.1016/j.otohns.2007.05.012.
Results Reference
background
PubMed Identifier
15958001
Citation
Hagen B, Eriksson N, Sundset M. Randomised controlled trial of LigaSure versus conventional suture ligature for abdominal hysterectomy. BJOG. 2005 Jul;112(7):968-70. doi: 10.1111/j.1471-0528.2005.00561.x.
Results Reference
background
PubMed Identifier
15713149
Citation
Hefni MA, Bhaumik J, El-Toukhy T, Kho P, Wong I, Abdel-Razik T, Davies AE. Safety and efficacy of using the LigaSure vessel sealing system for securing the pedicles in vaginal hysterectomy: randomised controlled trial. BJOG. 2005 Mar;112(3):329-33. doi: 10.1111/j.1471-0528.2004.00325.x.
Results Reference
background
PubMed Identifier
8585113
Citation
Kaplan B, Wang Z, Keilani T, Kaufman DB. The specificity of monoclonal fluorescence polarization immunoassay for cyclosporine in recipients of simultaneous pancreas-kidney transplants. Ther Drug Monit. 1995 Oct;17(5):499-503. doi: 10.1097/00007691-199510000-00010.
Results Reference
background
PubMed Identifier
18158799
Citation
Kossi J, Luostarinen M, Kontula I, Laato M. Laparoscopic sigmoid and rectal resection using an electrothermal bipolar vessel sealing device. J Laparoendosc Adv Surg Tech A. 2007 Dec;17(6):719-22. doi: 10.1089/lap.2006.0238.
Results Reference
background
PubMed Identifier
17299268
Citation
Sahin DA, Kusaslan R, Sahin O, Akbulut G, Bas O, Dilek ON. Histopathological effects of bipolar vessel sealing devices on liver parenchyma and comparison with suture method: an experimental study. Eur Surg Res. 2007;39(2):111-7. doi: 10.1159/000099599. Epub 2007 Feb 13.
Results Reference
background
PubMed Identifier
19105669
Citation
Ching SS, Verbeke CS, Homer-Vanniasinkam S, McMahon MJ. Comparison of torsional and linear mode ultrasonic coagulating shears for sealing veins. J Laparoendosc Adv Surg Tech A. 2008 Dec;18(6):819-24. doi: 10.1089/lap.2008.0066.
Results Reference
background
PubMed Identifier
15615929
Citation
Yekeler E, Danalioglu A, Movasseghi B, Yilmaz S, Karaca C, Kaymakoglu S, Acunas B. Crohn disease activity evaluated by Doppler ultrasonography of the superior mesenteric artery and the affected small-bowel segments. J Ultrasound Med. 2005 Jan;24(1):59-65. doi: 10.7863/jum.2005.24.1.59.
Results Reference
background
PubMed Identifier
9011692
Citation
Shatapathy P, Aggarwal BK, Punnen J. Inferior mesenteric artery as a free arterial conduit for myocardial revascularization. J Thorac Cardiovasc Surg. 1997 Jan;113(1):210-1. doi: 10.1016/S0022-5223(97)70417-3. No abstract available.
Results Reference
background
PubMed Identifier
12842513
Citation
van Andel CJ, Pistecky PV, Borst C. Mechanical properties of porcine and human arteries: implications for coronary anastomotic connectors. Ann Thorac Surg. 2003 Jul;76(1):58-64; discussion 64-5. doi: 10.1016/s0003-4975(03)00263-7.
Results Reference
background

Learn more about this trial

EnSeal Efficacy and Bursting Pressure in Human Vessels

We'll reach out to this number within 24 hrs