search
Back to results

Efficacy of the Chronic Application of Tear Formulations

Primary Purpose

Dry Eye

Status
Unknown status
Phase
Not Applicable
Locations
United Kingdom
Study Type
Interventional
Intervention
Next Generation Emulsion
Refresh Dry Eye Therapy
Refresh Contacts
Sponsored by
Glasgow Caledonian University
About
Eligibility
Locations
Arms
Outcomes
Full info

About this trial

This is an interventional treatment trial for Dry Eye

Eligibility Criteria

18 Years - 79 Years (Adult, Older Adult)All SexesAccepts Healthy Volunteers

Inclusion Criteria:

  • Be between the ages of 18 and 79 years of age.
  • Must understand and be able, willing and likely to fully comply with study procedures and restrictions.

Exclusion Criteria:

  • Active ocular allergy
  • Current contact lens wear
  • Any topical ophthalmic drops within 1 week of initial screening visit.
  • Started or changed the dose of chronic systemic medication known to affect tear production including, but not limited to antihistamines, antidepressants, diuretics, corticosteroids or immunomodulators within 30 days of initial screening visit.
  • Systemic disease known to affect tear production or loss including, but not limited to thyroid eye disease, that has been diagnosed or has not been stable within 30 days initial of screening visit.
  • Known hypersensitivity to any of the agents used in testing.

Sites / Locations

  • Glasgow Caledonian University

Arms of the Study

Arm 1

Arm 2

Arm 3

Arm Type

Experimental

Active Comparator

Active Comparator

Arm Label

Next Generation Emulsion

Refresh Dry Eye Therapy

Refresh Contacts

Arm Description

Next Generation Emulsion Multi-Dose Eye Drop (9963X) is a sterile, buffered, aqueous and emulsion topical ophthalmic product formulated for the relief of ocular surface irritation and symptoms of dryness. The Next Generation Emulsion 9963X formulation is an oil-in-water aqueous emulsion intended to replenish deficient aqueous and lipid components and stabilising the tear film.

A preserved multi-dose formulation for use in treating dry eye symptomatology. The key ingredients are Castor oil, Polysorbate 80, Carbomer 1342 and Glycerin. Refresh Dry Eye Therapy® Lubricant Eye Drops contains emulsified castor oil, which enhances the natural oily superficial tear layer on the ocular surface. By stabilizing and supplementing the lipid layer, castor oil may retard evaporation of surface moisture.

Solution contains carboxymethylcellulose sodium (carmellose), sodium chloride, boric acid, sodium borate, potassium chloride, calcium chloride, magnesium chloride, Purite®, sodium hydroxide, and purified water. This product is registered as a CE Mark medical device. Refresh Contacts Comfort drops providing soothing relief from tired, dry eyes. Although intended for contact lens wearers, the primary indication is for relief of dry eyes as is being studied in this investigation.

Outcomes

Primary Outcome Measures

Tear Film Evaporation
Tear film evaporation will be determined with a 'Servo-Med EP-Evaporimeter'. This measures the relative humidity and temperature at two sensors separated by a known distance, above the evaporative surface. The ocular surface evaporation will be calculated from measurements of fluid loss with the eyes open and closed while the subject sits with the eye covered by a modified goggle.

Secondary Outcome Measures

Interferometry
The structure and quality of the tear film will be assessed by observing the interference fringes of the lipid layer. Interferometry facilitated with a miniature slow motion video will be used. The grading system developed previously in our laboratory will be utilised to grade the tear film distribution. This grading system classifies the tear film structure on the basis of the distribution of tears after a blink. Measurements are made while the subject sits quietly and looks into the lens of the device.
Tear Film Osmolarity
Tear film osmolarity was measured using an 'OcuSense TearLab Osmometer'. This employs a single use, disposable test card mounted to a collection pen, to obtain a small sample of tear fluid by passive capillary action from the inferior-temporal tear meniscus. The measurement of the electrical impedance is carried out within the pen. The pen is then docked into the reader, which calculates and displays the osmolarity result.
Non-invasive tear break up time
The 'HIR-CAL Grid' system based on a modified Bausch and Lomb keratometer will be used. The 'HIR-CAL Grid'will be focused on the pre-corneal tear film and the time before first distortion of the grid image will be recorded. This will indicate the non-invasive tear break up time. Three measurements will be taken while the subject is instructed to blink and then to hold the eye open while the examiner watches the reflection from the tear film, and the mean calculated.
Tear sampling and bio-marker analysis
Approximately 1 μl of tears will be collected from the subject's eye using a sterile micropipette. It will then be diluted in cytokine assay buffer and simultaneously analysed for biomarkers of ocular surface disease (cytokines) using the Luminex Beadlyte assay system. The bio-markers to be studied are included in the Human high sensitivity cytokine/chemokine kit (Millipore). These markers are associated with pro-inflammatory activation and have been previously studied in dry eye and other inflammatory conditions.

Full Information

First Posted
June 23, 2011
Last Updated
June 30, 2011
Sponsor
Glasgow Caledonian University
Collaborators
Allergan
search

1. Study Identification

Unique Protocol Identification Number
NCT01384851
Brief Title
Efficacy of the Chronic Application of Tear Formulations
Official Title
Therapeutic Efficacy of the Chronic Application of Tear Formulations for Dry Eye and Normal Subjects Under Conditions of Environmental Stress
Study Type
Interventional

2. Study Status

Record Verification Date
February 2011
Overall Recruitment Status
Unknown status
Study Start Date
July 2011 (undefined)
Primary Completion Date
November 2011 (Anticipated)
Study Completion Date
November 2011 (Anticipated)

3. Sponsor/Collaborators

Name of the Sponsor
Glasgow Caledonian University
Collaborators
Allergan

4. Oversight

Data Monitoring Committee
Yes

5. Study Description

Brief Summary
The purpose of this study is to determine the therapeutic effect of the chronic application of eye-drops on tear evaporation rate in dry eye and normal subjects exposed to a condition of environmental stress. The effect will be studied in terms of changes in tear physiology and the inflammatory biomarkers on the ocular surface.
Detailed Description
Environmentally induced dry eye is a condition which occurs in otherwise asymptomatic individuals in certain situations, for example with the use of computers, in overheated or air conditioned workplaces and in conditions of low humidity. The most common ocular complaints associated with these environments are burning, dryness, stinging, and grittiness. Although the exact cause of these symptoms is unknown, it is thought that increased tear evaporation rate due to low humidity plays a vital role. The changes in tear film physiology, which occurs in these environments, have traditionally been dealt with by the use of eye drops (particularly the highly viscous variety), which have been shown to be an effective therapeutic option in the treatment of environmental dry eye disease. Previous studies of the use of eye-drops of various formulations has shown improvements in tear physiology in mild to moderate dry eye patients with their use in both acute and chronic application protocols. In this study, an attempt was made to relate the effects on tear physiology induced by variations in environmental conditions to the beneficial effect produced by the use of eye-drops.

6. Conditions and Keywords

Primary Disease or Condition Being Studied in the Trial, or the Focus of the Study
Dry Eye

7. Study Design

Primary Purpose
Treatment
Study Phase
Not Applicable
Interventional Study Model
Crossover Assignment
Masking
Participant
Allocation
Randomized
Enrollment
38 (Anticipated)

8. Arms, Groups, and Interventions

Arm Title
Next Generation Emulsion
Arm Type
Experimental
Arm Description
Next Generation Emulsion Multi-Dose Eye Drop (9963X) is a sterile, buffered, aqueous and emulsion topical ophthalmic product formulated for the relief of ocular surface irritation and symptoms of dryness. The Next Generation Emulsion 9963X formulation is an oil-in-water aqueous emulsion intended to replenish deficient aqueous and lipid components and stabilising the tear film.
Arm Title
Refresh Dry Eye Therapy
Arm Type
Active Comparator
Arm Description
A preserved multi-dose formulation for use in treating dry eye symptomatology. The key ingredients are Castor oil, Polysorbate 80, Carbomer 1342 and Glycerin. Refresh Dry Eye Therapy® Lubricant Eye Drops contains emulsified castor oil, which enhances the natural oily superficial tear layer on the ocular surface. By stabilizing and supplementing the lipid layer, castor oil may retard evaporation of surface moisture.
Arm Title
Refresh Contacts
Arm Type
Active Comparator
Arm Description
Solution contains carboxymethylcellulose sodium (carmellose), sodium chloride, boric acid, sodium borate, potassium chloride, calcium chloride, magnesium chloride, Purite®, sodium hydroxide, and purified water. This product is registered as a CE Mark medical device. Refresh Contacts Comfort drops providing soothing relief from tired, dry eyes. Although intended for contact lens wearers, the primary indication is for relief of dry eyes as is being studied in this investigation.
Intervention Type
Drug
Intervention Name(s)
Next Generation Emulsion
Intervention Description
One drop both eyes 4 times daily for two weeks
Intervention Type
Drug
Intervention Name(s)
Refresh Dry Eye Therapy
Intervention Description
One drop both eyes four times daily for two weeks
Intervention Type
Drug
Intervention Name(s)
Refresh Contacts
Intervention Description
One drop both eyes four times daily for two weeks
Primary Outcome Measure Information:
Title
Tear Film Evaporation
Description
Tear film evaporation will be determined with a 'Servo-Med EP-Evaporimeter'. This measures the relative humidity and temperature at two sensors separated by a known distance, above the evaporative surface. The ocular surface evaporation will be calculated from measurements of fluid loss with the eyes open and closed while the subject sits with the eye covered by a modified goggle.
Time Frame
Each subject will be followed for the duration of the study, an expected average of 8-9 weeks
Secondary Outcome Measure Information:
Title
Interferometry
Description
The structure and quality of the tear film will be assessed by observing the interference fringes of the lipid layer. Interferometry facilitated with a miniature slow motion video will be used. The grading system developed previously in our laboratory will be utilised to grade the tear film distribution. This grading system classifies the tear film structure on the basis of the distribution of tears after a blink. Measurements are made while the subject sits quietly and looks into the lens of the device.
Time Frame
Each subject will be followed for the duration of the study, an expected average of 8-9 weeks
Title
Tear Film Osmolarity
Description
Tear film osmolarity was measured using an 'OcuSense TearLab Osmometer'. This employs a single use, disposable test card mounted to a collection pen, to obtain a small sample of tear fluid by passive capillary action from the inferior-temporal tear meniscus. The measurement of the electrical impedance is carried out within the pen. The pen is then docked into the reader, which calculates and displays the osmolarity result.
Time Frame
Each subject will be followed for the duration of the study, an expected average of 8-9 weeks
Title
Non-invasive tear break up time
Description
The 'HIR-CAL Grid' system based on a modified Bausch and Lomb keratometer will be used. The 'HIR-CAL Grid'will be focused on the pre-corneal tear film and the time before first distortion of the grid image will be recorded. This will indicate the non-invasive tear break up time. Three measurements will be taken while the subject is instructed to blink and then to hold the eye open while the examiner watches the reflection from the tear film, and the mean calculated.
Time Frame
Each subject will be followed for the duration of the study, an expected average of 8-9 weeks
Title
Tear sampling and bio-marker analysis
Description
Approximately 1 μl of tears will be collected from the subject's eye using a sterile micropipette. It will then be diluted in cytokine assay buffer and simultaneously analysed for biomarkers of ocular surface disease (cytokines) using the Luminex Beadlyte assay system. The bio-markers to be studied are included in the Human high sensitivity cytokine/chemokine kit (Millipore). These markers are associated with pro-inflammatory activation and have been previously studied in dry eye and other inflammatory conditions.
Time Frame
Each subject will be followed for the duration of the study, an expected average of 8-9 weeks

10. Eligibility

Sex
All
Minimum Age & Unit of Time
18 Years
Maximum Age & Unit of Time
79 Years
Accepts Healthy Volunteers
Accepts Healthy Volunteers
Eligibility Criteria
Inclusion Criteria: Be between the ages of 18 and 79 years of age. Must understand and be able, willing and likely to fully comply with study procedures and restrictions. Exclusion Criteria: Active ocular allergy Current contact lens wear Any topical ophthalmic drops within 1 week of initial screening visit. Started or changed the dose of chronic systemic medication known to affect tear production including, but not limited to antihistamines, antidepressants, diuretics, corticosteroids or immunomodulators within 30 days of initial screening visit. Systemic disease known to affect tear production or loss including, but not limited to thyroid eye disease, that has been diagnosed or has not been stable within 30 days initial of screening visit. Known hypersensitivity to any of the agents used in testing.
Central Contact Person:
First Name & Middle Initial & Last Name or Official Title & Degree
Alan Tomlinson, DSc PhD
Phone
0044 141 331
Ext
3380
Email
A.Tomlinson@gcu.ac.uk
Overall Study Officials:
First Name & Middle Initial & Last Name & Degree
Alan Tomlinson, DSc PhD
Organizational Affiliation
Glasgow Caledonian University
Official's Role
Principal Investigator
Facility Information:
Facility Name
Glasgow Caledonian University
City
Glasgow
ZIP/Postal Code
G4 0BA
Country
United Kingdom

12. IPD Sharing Statement

Learn more about this trial

Efficacy of the Chronic Application of Tear Formulations

We'll reach out to this number within 24 hrs