search
Back to results

Sigma CR150 Versus Sigma CR Knee RCT

Primary Purpose

Osteoarthritis

Status
Completed
Phase
Phase 4
Locations
International
Study Type
Interventional
Intervention
Sigma CR150
Sigma CR
Sponsored by
DePuy International
About
Eligibility
Locations
Arms
Outcomes
Full info

About this trial

This is an interventional treatment trial for Osteoarthritis focused on measuring Sigma, cruciate, retaining, fixed, primary, total, knee, arthroplasty, cemented, osteoarthritis

Eligibility Criteria

50 Years - 75 Years (Adult, Older Adult)All SexesDoes not accept healthy volunteers

Inclusion Criteria:

i)Male or female subjects, aged between 50 and 75 years inclusive.

ii)Subjects who are able to give voluntary, written informed consent to participate in this clinical investigation and from whom consent has been obtained.

iii) Subjects who, in the opinion of the Clinical Investigator, are able to understand this clinical investigation, co-operate with the investigational procedures and are willing to return to the hospital for all the required post-operative follow-ups.

iv) Subjects defined by the Investigator as ASA Grade I or II.

v) Subjects with a primary diagnosis of osteoarthritis.

vi) Subjects who require a primary total knee arthroplasty.

vii) Subjects who can achieve active flexion of 90 degrees.

Exclusion Criteria:

i) Subjects who, in the opinion of the Clinical Investigator, have an existing condition that would compromise their participation and follow-up in this clinical investigation.

ii) Subjects who are known drug or alcohol abusers or with psychological disorders that could affect follow-up care or treatment outcomes.

iii) Subjects who have participated in a clinical investigation with an investigational product in the last month.

iv) Subjects who are currently involved in any injury litigation claims.

v) Subjects with an anatomical limb alignment of above 20 degrees varus or valgus.

vi) Subjects with a fixed flexion deformity of over 20 degrees.

vii) Subjects with recurvatum (definition: hyperextension ≥ 5 degrees).

viii) Subjects who cannot flex their hip to 90 degrees.

ix) Subjects with a BMI of 35 or above.

x) Subjects defined by the Investigator as ASA Grade III-V.

xi) Subjects who are identified pre-operatively as having bone defects which require augmentation.

xii) Subjects who have previously undergone total or unicondylar knee arthroplasty, high tibial osteotomy, ligament reconstruction, ORIF or with previous fracture in the knee joint.

xiii) Subjects with primary or secondary diagnosis of inflammatory or traumatic arthritis.

xiv) Subjects who have undergone contralateral total knee arthroplasty during the previous 6 months.

xv) Subjects who in the opinion of the Investigator require patellar resurfacing.

Intra-operative exclusion criteria:

i) Subjects who have uncontained bone defects or defects bigger than 8 mm3 and/or require augmentation.

ii) Subjects who are not suitable to receive both the study and comparator devices.

iii) Subjects who require patellar resurfacing

Sites / Locations

  • Sunshine Hospitals
  • Singapore General Hospital
  • Victoria Hospital
  • Calderdale Royal Hospital

Arms of the Study

Arm 1

Arm 2

Arm Type

Active Comparator

Active Comparator

Arm Label

Sigma CR150

Sigma CR

Arm Description

Sigma CR150 femoral component used in combination with the Highly Polished Cobalt Chrome fixed bearing tibial tray and the Curved (XLK) polyethylene bearing (cemented, no patellar resurfacing).

Sigma CR femoral component used in combination with the Highly Polished Cobalt Chrome fixed bearing tibial tray and the Curved (XLK) polyethylene bearing (cemented, no patellar resurfacing).

Outcomes

Primary Outcome Measures

Percentage of Knees Who Survived at 2 Years Post-operative
The Kaplan-Meier success rate at 24-months post-operatively was calculated with Kaplan-Meier time-to-event methodology, where the time variable for patients who were successful (no components revised for any reason) was censored at the time of last follow-up.

Secondary Outcome Measures

Change From Baseline in Goniometer Measured Maximum Passive Flexion at 2 Years
Comparative evaluation of the change from baseline values in 2 year goniometer-measured passive flexion. A goniometer is an instrument used to measure angles in degrees and captures the change in angle between the upper and lower leg
Knee Injury and Osteoarthritis Outcome Pain Subscore - 1 Year
Comparative evaluation of the change from baseline values at 1 years in Knee Injury and Osteoarthritis Outcome Pain Subscore The subscore ranges from 0 (no pain) to 36 (extreme pain). The subscore is then transformed into a 0 (extreme pain) to 100 (no pain) scale. 100 - (score x 100) / 36 = transformed score
Knee Injury and Osteoarthritis Outcome Pain Subscore - 2 Years
Comparative evaluation of the change from baseline values at 2 years in Knee Injury and Osteoarthritis Outcome Pain Subscore The subscore ranges from 0 (no pain) to 36 (extreme pain). The subscore is then transformed into a 0 (extreme pain) to 100 (no pain) scale. 100 - (score x 100) / 36 = transformed score
Knee Injury and Osteoarthritis Outcome Symptoms Subscore - 1 Years
Comparative evaluation of the change from baseline values at 1 year in Knee Injury and Osteoarthritis Outcome Symptom Subscore The subscore ranges from 0 (no symptoms) to 36 (always have symptoms). The subscore is then transformed into a 0 (always have symptoms) to 100 (never have symptoms) scale. 100 - (score x 100) / 36 = transformed score
Knee Injury and Osteoarthritis Outcome Symptom Subscore - 2 Years
Comparative evaluation of the change from baseline values at 2 years in Knee Injury and Osteoarthritis Outcome Symptom Subscore The subscore ranges from 0 (never have symptoms) to 28 (always have symptoms). The subscore is then transformed into a 0 (always have symptoms) to 100 (never have symptoms) scale. 100 - (score x 100) / 28 = transformed score
Knee Injury and Osteoarthritis Outcome - Activities of Daily Living Subscore - 1 Years
Comparative evaluation of the change from baseline values at 1 years in Knee Injury and Osteoarthritis Outcome Symptom Subscore The subscore ranges from 0 (no difficulty) to 68 (extreme difficulty). The subscore is then transformed into a 0 (extreme difficulty) to 100 (no difficulty) scale. 100 - (score x 100) / 68 = transformed score
Knee Injury and Osteoarthritis Outcome - Activities of Daily Living Subscore - 2 Years
Comparative evaluation of the change from baseline values at 2 years in Knee Injury and Osteoarthritis Outcome Activities of Daily Living Subscore The subscore ranges from 0 (no difficulty) to 68 (extreme difficulty). The subscore is then transformed into a 0 (extreme difficulty) to 100 (no difficulty) scale. 100 - (score x 100) / 68 = transformed score
Knee Injury and Osteoarthritis Outcome - Sport and Recreation Subscore - 1 Years
Comparative evaluation of the change from baseline values at 1 years in Knee Injury and Osteoarthritis Outcome Activities of Daily Living Subscore The subscore ranges from 0 (no difficulty) to 20 (extreme difficulty). The subscore is then transformed into a 0 (extreme difficulty) to 100 (no difficulty) scale. 100 - (score x 100) / 20 = transformed score
Knee Injury and Osteoarthritis Outcome Sport and Recreation Subscore - 2 Years
Comparative evaluation of the change from baseline values at 2 years in Knee Injury and Osteoarthritis Outcome Activities of Daily Living Subscore The subscore ranges from 0 (no difficulty) to 20 (extreme difficulty). The subscore is then transformed into a 0 (extreme difficulty) to 100 (no difficulty) scale. 100 - (score x 100) / 20 = transformed score
Knee Injury and Osteoarthritis Outcome - Quality of Life Subscore - 1 Years
Comparative evaluation of the change from baseline values at 1 years in Knee Injury and Osteoarthritis Outcome Activities of Quality of life Subscore The subscore ranges from 0 (no difficulty) to 16 (extreme difficulty). The subscore is then transformed into a 0 (extreme difficulty) to 100 (no difficulty) scale. 100 - (score x 100) / 16 = transformed score
Knee Injury and Osteoarthritis Outcome - Quality of Life Subscore - 2 Years
Comparative evaluation of the change from baseline values at 2 years in Knee Injury and Osteoarthritis Outcome Quality of Life Subscore The subscore ranges from 0 (no difficulty) to 16 (extreme difficulty). The subscore is then transformed into a 0 (extreme difficulty) to 100 (no difficulty) scale. 100 - (score x 100) / 16 = transformed score
Change From Baseline in Goniometer Measured Maximum Passive Flexion at 1 Year.
Comparative evaluation of the change from baseline values in 1 year goniometer-measured passive Flexion. A goniometer is an instrument used to measure angles in degrees and captures the change in angle between the upper and lower leg. Passive flexion involves moving the leg through range of motion without active muscle contraction
Change From Baseline in Goniometer Measured Maximum Passive Extension at 1 Year
Comparative evaluation of the change from baseline values in 1 year goniometer-measured passive extension. A goniometer is an instrument used to measure angles in degrees and captures the change in angle between the upper and lower leg. Passive extension involves the leg being moved without active muscle contraction
Change From Baseline in Goniometer Measured Maximum Passive Extension at 2 Years
Comparative evaluation of the change from baseline values in 2 year goniometer-measured passive extension. A goniometer is an instrument used to measure angles in degrees and captures the change in angle between the upper and lower leg. Passive extension involves moving the leg without active muscle contraction
Change From Baseline in Goniometer Measured Maximum Total Range of Motion at 1 Year
Comparative evaluation of the change from baseline values in 1 year goniometer-measured total range of motion. A goniometer is an instrument used to measure angles in degrees and captures the change in angle between the upper and lower leg. Total range of motion is the full distance the lower leg travels in relation to the upper leg.
Change From Baseline in Goniometer Measured Maximum Total Range of Motion at 2 Years.
Comparative evaluation of the change from baseline values in 2 year goniometer-measured total range of motion. A goniometer is an instrument used to measure angles in degrees and captures the change in angle between the upper and lower leg. Total range of motion is the full distance the lower leg travels in relation to the upper leg.
Number of Participants With Flexion Contracture at 1 Year
Summary of flexion contracture at 1 year time point. Flexion contracture is a shortening of the muscles that prevents the leg from fully extending
Number of Participants With Flexion Contracture at 2 Years
Summary of flexion contracture at 2 year time point.Flexion contracture is a shortening of the muscles that prevents the leg from fully extending
Total Knee Society Score at 1 Year
Total Knee Society Knee Score change from baseline at 1 year The Total Knee Society Score is comprised of two scores: the Knee Score and the Function Score. Both have a 0-100 range. Sub-scales are combined to compute a total score of 100 The Total Knee Society Score is made up of pain, range of motion, alignment and stability subscores. An Excellent score is 80-100, a good score is 70-79, a fair score is 60-69 and a poor score is anything below 60.
Total Knee Society Knee Score at 2 Years
Total Knee Society Knee Score change from baseline at 2 years The Total Knee Society Score is comprised of two scores: the Knee Score and the Function Score. Both have a 0-100 range. Sub-scales are combined to compute a total score of 100 The Total Knee Society Score is made up of pain, range of motion, alignment and stability subscores. An Excellent score is 80-100, a good score is 70-79, a fair score is 60-69 and a poor score is anything below 60.
Anatomic Alignment Angle
Anatomic angle measured at 1 year time point. If one draws a line from the center of the hip joint to the center of the ankle joint this is considered to be the mechanical axis of the femur. A line drawn through the center of the femoral shaft is the anatomic axis. The angle created at the intersection of these lines is referred to as the anatomic alignment angle. A normal angle is approximately 7-9 degrees "valgus" or slightly "knock-kneed". "Varus" angles are less common and are also referred to as "bow-legged".
Anatomic Alignment Angle
Anatomic angle measured at 2 year time point. If one draws a line from the center of the hip joint to the center of the ankle joint this is considered to be the mechanical axis of the femur. A line drawn through the center of the femoral shaft is the anatomic axis. The angle created at the intersection of these lines is referred to as the anatomic alignment angle. A normal angle is approximately 7-9 degrees "valgus" or slightly "knock-kneed". "Varus" angles are less common and are also referred to as "bow-legged".
Alignment - Femoral Component to Anatomic Angle.
Femoral component angle measured at 1 year time point. This angle is measured between a line drawn from the center of the femoral head and a line across the bottom of the femoral implant (condyles).
Alignment - Femoral Component to Anatomic Angle
Femoral component angle measured at 2 year time point. This angle is measured between a line drawn from the center of the femoral head and a line across the bottom of the femoral implant (condyles).
Alignment - Tibial Component to Anatomic Angle
Tibial component angle measured at 1 year time point. This angle is measured between a line drawn from the center of the femoral head tibial implant.
Alignment - Tibial Component to Anatomic Angle
Tibial component angle measured at 2 year time point. This angle is measured between a line drawn from the center of the femoral head tibial implant.
Alignment - Femoral Component Flexion
Femoral Component Flexion measured at 1 year time point. This measures the angle between a line drawn though the center of the side of the femur and a line drawn across the top of the flat inner surface of the femoral component.
Alignment - Femoral Component Flexion
Alignment - Femoral Component Flexion measured at 2 year time point. This measures the angle between a line drawn though the center of the side of the femur and a line drawn across the top of the flat inner surface of the femoral component.
Alignment - Tibial Posterior Slope
Tibial Posterior Slope measured at 1 year time point. This angle is measured between a line through the center of the side of the tibia and the top flat surface of the tibial implant
Alignment - Tibial Posterior Slope
Alignment - Tibial Posterior Slope measured at 2 year time point. This angle is measured between a line through the center of the side of the tibia and the top flat surface of the tibial implant
Number of Subjects With Radiolucencies - Femoral Component
The bone-implant interface at the femoral components were examined radiographically and radiolucencies were measured in millimeters. Radiolucent lines (RLLs) greater than 2mm are considered to be clinically significant.
Number of Subjects With Radiolucencies - Tibial Component
The bone-implant interface at the tibial components were examined radiographically and radiolucencies were measured in millimeters. Radiolucent lines (RLLs) greater than 2mm are considered to be clinically significant. Radiolucent lines greater than 2mm are considered to be clinically significant.
Radiographic Evaluation of Maximum Flexion
Maximum knee flexion measured radiographically at 1 year time point

Full Information

First Posted
August 9, 2011
Last Updated
July 22, 2019
Sponsor
DePuy International
search

1. Study Identification

Unique Protocol Identification Number
NCT01418378
Brief Title
Sigma CR150 Versus Sigma CR Knee RCT
Official Title
A Double-blinded Randomised Controlled Trial Comparing the Performance of the Sigma® CR150 and Sigma® CR Knee Systems, When Used in Fixed Bearing Primary Cruciate Retaining Total Knee Arthroplasty for the Treatment of Osteoarthritis
Study Type
Interventional

2. Study Status

Record Verification Date
July 2019
Overall Recruitment Status
Completed
Study Start Date
August 3, 2011 (Actual)
Primary Completion Date
February 17, 2016 (Actual)
Study Completion Date
February 17, 2016 (Actual)

3. Sponsor/Collaborators

Responsible Party, by Official Title
Sponsor
Name of the Sponsor
DePuy International

4. Oversight

Data Monitoring Committee
No

5. Study Description

Brief Summary
This study will compare two very similar designs of knee replacement device. One device (Sigma CR150) is a slightly modified version of the original (Sigma CR) and has been modified to enhance/accommodate higher flexion. The original device has been in widespread clinical use with excellent results since 1996 and this study will determine whether the design modifications of the newer device add further value. The newer device has been in clinical use with good short-term(unpublished) outcomes since becoming commercially available in January 2009. Achieving higher knee flexion may be required for cultural reasons or by the increasingly younger, more active patient population undergoing knee replacement today. In addition to promoting flexion, it is also possible that this design change may help the knee replacement to last longer than traditional implants in patients who achieve higher flexion. Therefore, the study will compare the two devices in terms of survivorship, flexion and other measures of the success of a total knee replacement (range of motion, knee-related quality of life, activity and generic quality of life) over the short-term. A minimum of one hundred and forty subjects (minimum 70 per group) with osteoarthritis and aged 50-75 years will be included at UK/international hospitals. Study duration is 2 years and patients will complete standard knee outcome scores plus radiological evaluation. Subjects would receive one of the study devices regardless of their involvement in the study, and apart from (possible)additional visits, x-rays and/or questionnaires, treatment and follow-up care will be as per the care they would receive outside of the study.

6. Conditions and Keywords

Primary Disease or Condition Being Studied in the Trial, or the Focus of the Study
Osteoarthritis
Keywords
Sigma, cruciate, retaining, fixed, primary, total, knee, arthroplasty, cemented, osteoarthritis

7. Study Design

Primary Purpose
Treatment
Study Phase
Phase 4
Interventional Study Model
Parallel Assignment
Masking
ParticipantOutcomes Assessor
Allocation
Randomized
Enrollment
191 (Actual)

8. Arms, Groups, and Interventions

Arm Title
Sigma CR150
Arm Type
Active Comparator
Arm Description
Sigma CR150 femoral component used in combination with the Highly Polished Cobalt Chrome fixed bearing tibial tray and the Curved (XLK) polyethylene bearing (cemented, no patellar resurfacing).
Arm Title
Sigma CR
Arm Type
Active Comparator
Arm Description
Sigma CR femoral component used in combination with the Highly Polished Cobalt Chrome fixed bearing tibial tray and the Curved (XLK) polyethylene bearing (cemented, no patellar resurfacing).
Intervention Type
Device
Intervention Name(s)
Sigma CR150
Other Intervention Name(s)
PFC Sigma CR150
Intervention Description
Sigma CR150 femoral component used in combination with the Highly Polished Cobalt Chrome fixed bearing tibial tray and the Curved (XLK) polyethylene bearing (cemented, no patellar resurfacing).
Intervention Type
Device
Intervention Name(s)
Sigma CR
Other Intervention Name(s)
PFC Sigma CR
Intervention Description
Sigma CR femoral component used in combination with the Highly Polished Cobalt Chrome fixed bearing tibial tray and the Curved (XLK) polyethylene bearing (cemented, no patellar resurfacing).
Primary Outcome Measure Information:
Title
Percentage of Knees Who Survived at 2 Years Post-operative
Description
The Kaplan-Meier success rate at 24-months post-operatively was calculated with Kaplan-Meier time-to-event methodology, where the time variable for patients who were successful (no components revised for any reason) was censored at the time of last follow-up.
Time Frame
2 Years
Secondary Outcome Measure Information:
Title
Change From Baseline in Goniometer Measured Maximum Passive Flexion at 2 Years
Description
Comparative evaluation of the change from baseline values in 2 year goniometer-measured passive flexion. A goniometer is an instrument used to measure angles in degrees and captures the change in angle between the upper and lower leg
Time Frame
Pre-operative baseline to 2 years
Title
Knee Injury and Osteoarthritis Outcome Pain Subscore - 1 Year
Description
Comparative evaluation of the change from baseline values at 1 years in Knee Injury and Osteoarthritis Outcome Pain Subscore The subscore ranges from 0 (no pain) to 36 (extreme pain). The subscore is then transformed into a 0 (extreme pain) to 100 (no pain) scale. 100 - (score x 100) / 36 = transformed score
Time Frame
Pre-operative baseline to 1 year
Title
Knee Injury and Osteoarthritis Outcome Pain Subscore - 2 Years
Description
Comparative evaluation of the change from baseline values at 2 years in Knee Injury and Osteoarthritis Outcome Pain Subscore The subscore ranges from 0 (no pain) to 36 (extreme pain). The subscore is then transformed into a 0 (extreme pain) to 100 (no pain) scale. 100 - (score x 100) / 36 = transformed score
Time Frame
2 years
Title
Knee Injury and Osteoarthritis Outcome Symptoms Subscore - 1 Years
Description
Comparative evaluation of the change from baseline values at 1 year in Knee Injury and Osteoarthritis Outcome Symptom Subscore The subscore ranges from 0 (no symptoms) to 36 (always have symptoms). The subscore is then transformed into a 0 (always have symptoms) to 100 (never have symptoms) scale. 100 - (score x 100) / 36 = transformed score
Time Frame
1 years
Title
Knee Injury and Osteoarthritis Outcome Symptom Subscore - 2 Years
Description
Comparative evaluation of the change from baseline values at 2 years in Knee Injury and Osteoarthritis Outcome Symptom Subscore The subscore ranges from 0 (never have symptoms) to 28 (always have symptoms). The subscore is then transformed into a 0 (always have symptoms) to 100 (never have symptoms) scale. 100 - (score x 100) / 28 = transformed score
Time Frame
2 years
Title
Knee Injury and Osteoarthritis Outcome - Activities of Daily Living Subscore - 1 Years
Description
Comparative evaluation of the change from baseline values at 1 years in Knee Injury and Osteoarthritis Outcome Symptom Subscore The subscore ranges from 0 (no difficulty) to 68 (extreme difficulty). The subscore is then transformed into a 0 (extreme difficulty) to 100 (no difficulty) scale. 100 - (score x 100) / 68 = transformed score
Time Frame
1 year
Title
Knee Injury and Osteoarthritis Outcome - Activities of Daily Living Subscore - 2 Years
Description
Comparative evaluation of the change from baseline values at 2 years in Knee Injury and Osteoarthritis Outcome Activities of Daily Living Subscore The subscore ranges from 0 (no difficulty) to 68 (extreme difficulty). The subscore is then transformed into a 0 (extreme difficulty) to 100 (no difficulty) scale. 100 - (score x 100) / 68 = transformed score
Time Frame
2 year
Title
Knee Injury and Osteoarthritis Outcome - Sport and Recreation Subscore - 1 Years
Description
Comparative evaluation of the change from baseline values at 1 years in Knee Injury and Osteoarthritis Outcome Activities of Daily Living Subscore The subscore ranges from 0 (no difficulty) to 20 (extreme difficulty). The subscore is then transformed into a 0 (extreme difficulty) to 100 (no difficulty) scale. 100 - (score x 100) / 20 = transformed score
Time Frame
1 year
Title
Knee Injury and Osteoarthritis Outcome Sport and Recreation Subscore - 2 Years
Description
Comparative evaluation of the change from baseline values at 2 years in Knee Injury and Osteoarthritis Outcome Activities of Daily Living Subscore The subscore ranges from 0 (no difficulty) to 20 (extreme difficulty). The subscore is then transformed into a 0 (extreme difficulty) to 100 (no difficulty) scale. 100 - (score x 100) / 20 = transformed score
Time Frame
2 year
Title
Knee Injury and Osteoarthritis Outcome - Quality of Life Subscore - 1 Years
Description
Comparative evaluation of the change from baseline values at 1 years in Knee Injury and Osteoarthritis Outcome Activities of Quality of life Subscore The subscore ranges from 0 (no difficulty) to 16 (extreme difficulty). The subscore is then transformed into a 0 (extreme difficulty) to 100 (no difficulty) scale. 100 - (score x 100) / 16 = transformed score
Time Frame
1 year
Title
Knee Injury and Osteoarthritis Outcome - Quality of Life Subscore - 2 Years
Description
Comparative evaluation of the change from baseline values at 2 years in Knee Injury and Osteoarthritis Outcome Quality of Life Subscore The subscore ranges from 0 (no difficulty) to 16 (extreme difficulty). The subscore is then transformed into a 0 (extreme difficulty) to 100 (no difficulty) scale. 100 - (score x 100) / 16 = transformed score
Time Frame
2 years
Title
Change From Baseline in Goniometer Measured Maximum Passive Flexion at 1 Year.
Description
Comparative evaluation of the change from baseline values in 1 year goniometer-measured passive Flexion. A goniometer is an instrument used to measure angles in degrees and captures the change in angle between the upper and lower leg. Passive flexion involves moving the leg through range of motion without active muscle contraction
Time Frame
1 year
Title
Change From Baseline in Goniometer Measured Maximum Passive Extension at 1 Year
Description
Comparative evaluation of the change from baseline values in 1 year goniometer-measured passive extension. A goniometer is an instrument used to measure angles in degrees and captures the change in angle between the upper and lower leg. Passive extension involves the leg being moved without active muscle contraction
Time Frame
1 year
Title
Change From Baseline in Goniometer Measured Maximum Passive Extension at 2 Years
Description
Comparative evaluation of the change from baseline values in 2 year goniometer-measured passive extension. A goniometer is an instrument used to measure angles in degrees and captures the change in angle between the upper and lower leg. Passive extension involves moving the leg without active muscle contraction
Time Frame
2 year
Title
Change From Baseline in Goniometer Measured Maximum Total Range of Motion at 1 Year
Description
Comparative evaluation of the change from baseline values in 1 year goniometer-measured total range of motion. A goniometer is an instrument used to measure angles in degrees and captures the change in angle between the upper and lower leg. Total range of motion is the full distance the lower leg travels in relation to the upper leg.
Time Frame
1 year
Title
Change From Baseline in Goniometer Measured Maximum Total Range of Motion at 2 Years.
Description
Comparative evaluation of the change from baseline values in 2 year goniometer-measured total range of motion. A goniometer is an instrument used to measure angles in degrees and captures the change in angle between the upper and lower leg. Total range of motion is the full distance the lower leg travels in relation to the upper leg.
Time Frame
2 years
Title
Number of Participants With Flexion Contracture at 1 Year
Description
Summary of flexion contracture at 1 year time point. Flexion contracture is a shortening of the muscles that prevents the leg from fully extending
Time Frame
1 years
Title
Number of Participants With Flexion Contracture at 2 Years
Description
Summary of flexion contracture at 2 year time point.Flexion contracture is a shortening of the muscles that prevents the leg from fully extending
Time Frame
2 years
Title
Total Knee Society Score at 1 Year
Description
Total Knee Society Knee Score change from baseline at 1 year The Total Knee Society Score is comprised of two scores: the Knee Score and the Function Score. Both have a 0-100 range. Sub-scales are combined to compute a total score of 100 The Total Knee Society Score is made up of pain, range of motion, alignment and stability subscores. An Excellent score is 80-100, a good score is 70-79, a fair score is 60-69 and a poor score is anything below 60.
Time Frame
1 year
Title
Total Knee Society Knee Score at 2 Years
Description
Total Knee Society Knee Score change from baseline at 2 years The Total Knee Society Score is comprised of two scores: the Knee Score and the Function Score. Both have a 0-100 range. Sub-scales are combined to compute a total score of 100 The Total Knee Society Score is made up of pain, range of motion, alignment and stability subscores. An Excellent score is 80-100, a good score is 70-79, a fair score is 60-69 and a poor score is anything below 60.
Time Frame
2 years
Title
Anatomic Alignment Angle
Description
Anatomic angle measured at 1 year time point. If one draws a line from the center of the hip joint to the center of the ankle joint this is considered to be the mechanical axis of the femur. A line drawn through the center of the femoral shaft is the anatomic axis. The angle created at the intersection of these lines is referred to as the anatomic alignment angle. A normal angle is approximately 7-9 degrees "valgus" or slightly "knock-kneed". "Varus" angles are less common and are also referred to as "bow-legged".
Time Frame
1 year time point
Title
Anatomic Alignment Angle
Description
Anatomic angle measured at 2 year time point. If one draws a line from the center of the hip joint to the center of the ankle joint this is considered to be the mechanical axis of the femur. A line drawn through the center of the femoral shaft is the anatomic axis. The angle created at the intersection of these lines is referred to as the anatomic alignment angle. A normal angle is approximately 7-9 degrees "valgus" or slightly "knock-kneed". "Varus" angles are less common and are also referred to as "bow-legged".
Time Frame
2 year time point
Title
Alignment - Femoral Component to Anatomic Angle.
Description
Femoral component angle measured at 1 year time point. This angle is measured between a line drawn from the center of the femoral head and a line across the bottom of the femoral implant (condyles).
Time Frame
1 year time point
Title
Alignment - Femoral Component to Anatomic Angle
Description
Femoral component angle measured at 2 year time point. This angle is measured between a line drawn from the center of the femoral head and a line across the bottom of the femoral implant (condyles).
Time Frame
2 year time point
Title
Alignment - Tibial Component to Anatomic Angle
Description
Tibial component angle measured at 1 year time point. This angle is measured between a line drawn from the center of the femoral head tibial implant.
Time Frame
1 year time point
Title
Alignment - Tibial Component to Anatomic Angle
Description
Tibial component angle measured at 2 year time point. This angle is measured between a line drawn from the center of the femoral head tibial implant.
Time Frame
2 year time point
Title
Alignment - Femoral Component Flexion
Description
Femoral Component Flexion measured at 1 year time point. This measures the angle between a line drawn though the center of the side of the femur and a line drawn across the top of the flat inner surface of the femoral component.
Time Frame
1 year time point
Title
Alignment - Femoral Component Flexion
Description
Alignment - Femoral Component Flexion measured at 2 year time point. This measures the angle between a line drawn though the center of the side of the femur and a line drawn across the top of the flat inner surface of the femoral component.
Time Frame
2 year time point
Title
Alignment - Tibial Posterior Slope
Description
Tibial Posterior Slope measured at 1 year time point. This angle is measured between a line through the center of the side of the tibia and the top flat surface of the tibial implant
Time Frame
1 year time point
Title
Alignment - Tibial Posterior Slope
Description
Alignment - Tibial Posterior Slope measured at 2 year time point. This angle is measured between a line through the center of the side of the tibia and the top flat surface of the tibial implant
Time Frame
2 year time point
Title
Number of Subjects With Radiolucencies - Femoral Component
Description
The bone-implant interface at the femoral components were examined radiographically and radiolucencies were measured in millimeters. Radiolucent lines (RLLs) greater than 2mm are considered to be clinically significant.
Time Frame
6 to 12 week and 24 month intervals
Title
Number of Subjects With Radiolucencies - Tibial Component
Description
The bone-implant interface at the tibial components were examined radiographically and radiolucencies were measured in millimeters. Radiolucent lines (RLLs) greater than 2mm are considered to be clinically significant. Radiolucent lines greater than 2mm are considered to be clinically significant.
Time Frame
6 weeks to 24 months
Title
Radiographic Evaluation of Maximum Flexion
Description
Maximum knee flexion measured radiographically at 1 year time point
Time Frame
1 year time point

10. Eligibility

Sex
All
Minimum Age & Unit of Time
50 Years
Maximum Age & Unit of Time
75 Years
Accepts Healthy Volunteers
No
Eligibility Criteria
Inclusion Criteria: i)Male or female subjects, aged between 50 and 75 years inclusive. ii)Subjects who are able to give voluntary, written informed consent to participate in this clinical investigation and from whom consent has been obtained. iii) Subjects who, in the opinion of the Clinical Investigator, are able to understand this clinical investigation, co-operate with the investigational procedures and are willing to return to the hospital for all the required post-operative follow-ups. iv) Subjects defined by the Investigator as ASA Grade I or II. v) Subjects with a primary diagnosis of osteoarthritis. vi) Subjects who require a primary total knee arthroplasty. vii) Subjects who can achieve active flexion of 90 degrees. Exclusion Criteria: i) Subjects who, in the opinion of the Clinical Investigator, have an existing condition that would compromise their participation and follow-up in this clinical investigation. ii) Subjects who are known drug or alcohol abusers or with psychological disorders that could affect follow-up care or treatment outcomes. iii) Subjects who have participated in a clinical investigation with an investigational product in the last month. iv) Subjects who are currently involved in any injury litigation claims. v) Subjects with an anatomical limb alignment of above 20 degrees varus or valgus. vi) Subjects with a fixed flexion deformity of over 20 degrees. vii) Subjects with recurvatum (definition: hyperextension ≥ 5 degrees). viii) Subjects who cannot flex their hip to 90 degrees. ix) Subjects with a BMI of 35 or above. x) Subjects defined by the Investigator as ASA Grade III-V. xi) Subjects who are identified pre-operatively as having bone defects which require augmentation. xii) Subjects who have previously undergone total or unicondylar knee arthroplasty, high tibial osteotomy, ligament reconstruction, ORIF or with previous fracture in the knee joint. xiii) Subjects with primary or secondary diagnosis of inflammatory or traumatic arthritis. xiv) Subjects who have undergone contralateral total knee arthroplasty during the previous 6 months. xv) Subjects who in the opinion of the Investigator require patellar resurfacing. Intra-operative exclusion criteria: i) Subjects who have uncontained bone defects or defects bigger than 8 mm3 and/or require augmentation. ii) Subjects who are not suitable to receive both the study and comparator devices. iii) Subjects who require patellar resurfacing
Overall Study Officials:
First Name & Middle Initial & Last Name & Degree
Gautam Chakrabarty, FRCS Orth.
Organizational Affiliation
Calderdale and Huddersfield Foundation NHS Trust
Official's Role
Principal Investigator
Facility Information:
Facility Name
Sunshine Hospitals
City
Secunderabad
State/Province
Andhra Pradesh
ZIP/Postal Code
500003
Country
India
Facility Name
Singapore General Hospital
City
Singapore
ZIP/Postal Code
169608
Country
Singapore
Facility Name
Victoria Hospital
City
Kirkcaldy
State/Province
Fife
ZIP/Postal Code
KY2 5AH
Country
United Kingdom
Facility Name
Calderdale Royal Hospital
City
Halifax
State/Province
West Yorkshire
ZIP/Postal Code
HX3 0PW
Country
United Kingdom

12. IPD Sharing Statement

Learn more about this trial

Sigma CR150 Versus Sigma CR Knee RCT

We'll reach out to this number within 24 hrs