Reduction in IV Associated Contamination
Primary Purpose
Post-operative Infections
Status
Completed
Phase
Not Applicable
Locations
United States
Study Type
Interventional
Intervention
Passive Bundle PSI (Problem Solving Innovations) Medical HubScrub, PSI Medical DocIt
Sponsored by

About this trial
This is an interventional prevention trial for Post-operative Infections focused on measuring IV contamination, intravenous contamination, stopcock contamination, surgical site infection
Eligibility Criteria
Inclusion Criteria:
- Adult patient undergoing surgery or procedure in operating room
- Undergoing general anesthesia
Exclusion Criteria:
- Children (age < 18 years)
- Lack of intravenous access
- failure of anesthesia provider to complete training on experimental device
Sites / Locations
- Dartmouth-Hitchcock Medical Center
Arms of the Study
Arm 1
Arm 2
Arm Type
No Intervention
Experimental
Arm Label
Control
Problem Solving Innovations (PSI) Experimental
Arm Description
Control arm using standard of care operating room procedures and equipment
Implementation of the passive bundle including HubScrub and DocIt
Outcomes
Primary Outcome Measures
Presence of Bacterial IV Stopcock Lumen Contamination
The presence of bacteria in the stopcock lumen was assessed by analyzing swab cultures of the lumens. Each swab potentially containing bacteria from any of the 3 lumens of the stopcock sets were analyzed
Secondary Outcome Measures
Presence of Positive Bacterial Culture in IV Stopcock Due to Effluent Contamination
Open lumen ports were removed from the patient; sent directly to the anesthesiology microbiology laboratory; connected by the same clinical laboratory scientist to sterile catheters using sterile, aseptic technique; and injected directly into a BacT/Alert 3D system (bioMérieux Inc., Durham, NC) with 2 mL of sterile saline per port. BacT/Alert is a blood culture system that automatically monitors bacterial growth using colorimetry; a sensor inserted at the bottom of the bottle changes color on detecting the carbon dioxide produced by the growth of the bacteria. Catheters were then removed, and the bottles were directly incubated in the BacT/Alert system for 5 days or until positive. Once positive, the liquid in the bottle was examined to identify the organism.
Full Information
NCT ID
NCT01426217
First Posted
August 29, 2011
Last Updated
September 20, 2018
Sponsor
Dartmouth-Hitchcock Medical Center
Collaborators
PSI Medical
1. Study Identification
Unique Protocol Identification Number
NCT01426217
Brief Title
Reduction in IV Associated Contamination
Official Title
Reduction in Intraoperative Lumen Contamination of Standard 3-Way Open Lumen Stopcock Sets Through Use of a Novel, Passive Bundle
Study Type
Interventional
2. Study Status
Record Verification Date
August 2018
Overall Recruitment Status
Completed
Study Start Date
August 2011 (undefined)
Primary Completion Date
November 2011 (Actual)
Study Completion Date
November 2011 (Actual)
3. Sponsor/Collaborators
Responsible Party, by Official Title
Sponsor
Name of the Sponsor
Dartmouth-Hitchcock Medical Center
Collaborators
PSI Medical
4. Oversight
Data Monitoring Committee
No
5. Study Description
Brief Summary
The purpose of this study is to investigate whether implementing a novel syringe and IV stopcock cap system impregnated with alcohol will reduce IV catheter bacterial contamination and infections in patients.
Detailed Description
Bacterial contamination of patient intravenous stopcock sets is a common intraoperative event associated with increased patient mortality, possibly via an infectious mechanism. The most common type of intravenous tubing used in operating rooms is the open lumen stopcock set which lacks a barrier between the environment and intraluminal space, and thus the intravascular space of the patient. The stopcock connector can be easily contaminated by provider hands due to improper handling of the device and/or contaminated by soiled syringe tips subsequently connected to the device. Further, the stopcock connector is often left uncapped by the provider and directly exposed to the environment. Thus, common breaches in intraoperative aseptic practice of healthcare providers can lead to bacterial contamination of the endoluminal space of the open lumen device. The primary aim of the current study is to assess the efficacy of a passive bundle designed to decrease intravenous stopcock and tubing intraluminal bacterial contamination. This passive bundle includes two novel interventions, a DOCit station and HubScrub caps. The HubScrub is designed to clean the needleless connectors and open lumen stopcock systems. The DOCit station is designed to simultaneously clean the interior and exterior of needle-less luer connectors of syringes with isopropyl alcohol while also providing a method of storage and organization of multiple syringes. The investigators hypothesize that the application of this passive bundle to the standard open lumen system commonly employed by anesthesia providers in the operating room will significantly reduce bacterial contamination of standard 3-way open lumen stopcock sets and improve patient safety.
6. Conditions and Keywords
Primary Disease or Condition Being Studied in the Trial, or the Focus of the Study
Post-operative Infections
Keywords
IV contamination, intravenous contamination, stopcock contamination, surgical site infection
7. Study Design
Primary Purpose
Prevention
Study Phase
Not Applicable
Interventional Study Model
Parallel Assignment
Masking
Investigator
Allocation
Randomized
Enrollment
594 (Actual)
8. Arms, Groups, and Interventions
Arm Title
Control
Arm Type
No Intervention
Arm Description
Control arm using standard of care operating room procedures and equipment
Arm Title
Problem Solving Innovations (PSI) Experimental
Arm Type
Experimental
Arm Description
Implementation of the passive bundle including HubScrub and DocIt
Intervention Type
Device
Intervention Name(s)
Passive Bundle PSI (Problem Solving Innovations) Medical HubScrub, PSI Medical DocIt
Other Intervention Name(s)
PSI Medical HubScrub, PSI Medical DocIt
Intervention Description
Implementation of passive bundle which includes HubScrub and DocIt device into the operating room environment.
Primary Outcome Measure Information:
Title
Presence of Bacterial IV Stopcock Lumen Contamination
Description
The presence of bacteria in the stopcock lumen was assessed by analyzing swab cultures of the lumens. Each swab potentially containing bacteria from any of the 3 lumens of the stopcock sets were analyzed
Time Frame
48 hours
Secondary Outcome Measure Information:
Title
Presence of Positive Bacterial Culture in IV Stopcock Due to Effluent Contamination
Description
Open lumen ports were removed from the patient; sent directly to the anesthesiology microbiology laboratory; connected by the same clinical laboratory scientist to sterile catheters using sterile, aseptic technique; and injected directly into a BacT/Alert 3D system (bioMérieux Inc., Durham, NC) with 2 mL of sterile saline per port. BacT/Alert is a blood culture system that automatically monitors bacterial growth using colorimetry; a sensor inserted at the bottom of the bottle changes color on detecting the carbon dioxide produced by the growth of the bacteria. Catheters were then removed, and the bottles were directly incubated in the BacT/Alert system for 5 days or until positive. Once positive, the liquid in the bottle was examined to identify the organism.
Time Frame
Until positive, up to 5 days
10. Eligibility
Sex
All
Minimum Age & Unit of Time
18 Years
Accepts Healthy Volunteers
Accepts Healthy Volunteers
Eligibility Criteria
Inclusion Criteria:
Adult patient undergoing surgery or procedure in operating room
Undergoing general anesthesia
Exclusion Criteria:
Children (age < 18 years)
Lack of intravenous access
failure of anesthesia provider to complete training on experimental device
Overall Study Officials:
First Name & Middle Initial & Last Name & Degree
Bryan S Brindeiro, MD
Organizational Affiliation
Dartmouth-Hitchcock Medical Center
Official's Role
Principal Investigator
First Name & Middle Initial & Last Name & Degree
Randy W Loftus, MD
Organizational Affiliation
Dartmouth-Hitchcock Medical Center
Official's Role
Study Director
Facility Information:
Facility Name
Dartmouth-Hitchcock Medical Center
City
Lebanon
State/Province
New Hampshire
ZIP/Postal Code
03756
Country
United States
12. IPD Sharing Statement
Citations:
PubMed Identifier
20686007
Citation
Loftus RW, Muffly MK, Brown JR, Beach ML, Koff MD, Corwin HL, Surgenor SD, Kirkland KB, Yeager MP. Hand contamination of anesthesia providers is an important risk factor for intraoperative bacterial transmission. Anesth Analg. 2011 Jan;112(1):98-105. doi: 10.1213/ANE.0b013e3181e7ce18. Epub 2010 Aug 4.
Results Reference
background
PubMed Identifier
19352154
Citation
Koff MD, Loftus RW, Burchman CC, Schwartzman JD, Read ME, Henry ES, Beach ML. Reduction in intraoperative bacterial contamination of peripheral intravenous tubing through the use of a novel device. Anesthesiology. 2009 May;110(5):978-85. doi: 10.1097/ALN.0b013e3181a06ec3.
Results Reference
background
PubMed Identifier
18719437
Citation
Loftus RW, Koff MD, Burchman CC, Schwartzman JD, Thorum V, Read ME, Wood TA, Beach ML. Transmission of pathogenic bacterial organisms in the anesthesia work area. Anesthesiology. 2008 Sep;109(3):399-407. doi: 10.1097/ALN.0b013e318182c855.
Results Reference
background
PubMed Identifier
23144441
Citation
Loftus RW, Brindeiro BS, Kispert DP, Patel HM, Koff MD, Jensen JT, Dodds TM, Yeager MP, Ruoff KL, Gallagher JD, Beach ML, Brown JR. Reduction in intraoperative bacterial contamination of peripheral intravenous tubing through the use of a passive catheter care system. Anesth Analg. 2012 Dec;115(6):1315-23. doi: 10.1213/ANE.0b013e31826d2aa4. Epub 2012 Nov 9.
Results Reference
result
Learn more about this trial
Reduction in IV Associated Contamination
We'll reach out to this number within 24 hrs