BIfurcation Optimal Treatment Strategy With LYMus Eluting Dedicated Bifurcation Versus Convention Stent Randomized Study (BIOSS LIM)
Primary Purpose
Coronary Bifurcation Stenosis
Status
Unknown status
Phase
Phase 4
Locations
Bulgaria
Study Type
Interventional
Intervention
BIOSS LIM implantation
BIOSS Lim
CarloS
Sponsored by
About this trial
This is an interventional treatment trial for Coronary Bifurcation Stenosis focused on measuring coronary bifurcation stenosis, dedicated bifurcation stent, sirolymus, PTS, BiOSS Lym
Eligibility Criteria
Inclusion Criteria
- Subject at least 18 years of age.
- Subject able to verbally confirm understandings of risks, benefits of receiving PCI for true bifurcation lesions, and he/she or his/her legally authorized representative provides written informed consent prior to any study related procedure.
- Target main branch lesion(s) located in a native coronary artery with diameter of ≥ 2.5 mm and ≤ 4.5 mm. Target side branch lesion(s) located in a native coronary artery with diameter of ≥ 2.0 mm.
- Target lesion(s) amenable for PCI with balloon angioplasty of the side branch.
Exclusion Criteria
- STEMI
- Non-cardiac co-morbid conditions are present with life expectancy <1 year or that may result in protocol non-compliance (per site investigator's medical judgment).
- Subjects who refuse to give informed consent.
- Subjects with LVEF<30%
- Subjects with moderate or severe degree valvular heart disease or primary cardiomyopathy
- Contraindications for 12 months DAP
Sites / Locations
- Medica Cor Heart HospitalRecruiting
Arms of the Study
Arm 1
Arm Type
Active Comparator
Arm Label
BIOSS implantation
Arm Description
Outcomes
Primary Outcome Measures
Major adverse cardiac events (MACE)
death, myocardial infarction (MI), target vessel revascularization (TVR)
Secondary Outcome Measures
Target lesion revascularization (TLR)
Clinically driven revascularization rates.
Full Information
NCT ID
NCT01430364
First Posted
September 3, 2011
Last Updated
December 24, 2013
Sponsor
Medica Cor Heart Hospital
1. Study Identification
Unique Protocol Identification Number
NCT01430364
Brief Title
BIfurcation Optimal Treatment Strategy With LYMus Eluting Dedicated Bifurcation Versus Convention Stent Randomized Study
Acronym
BIOSS LIM
Official Title
BIfurcation Optimal Treatment Strategy With LIMus Eluting Dedicated Bifurcation Versus Convention Stent Randomized Study
Study Type
Interventional
2. Study Status
Record Verification Date
December 2013
Overall Recruitment Status
Unknown status
Study Start Date
September 2011 (undefined)
Primary Completion Date
December 2013 (Anticipated)
Study Completion Date
May 2014 (Anticipated)
3. Sponsor/Collaborators
Responsible Party, by Official Title
Sponsor
Name of the Sponsor
Medica Cor Heart Hospital
4. Oversight
Data Monitoring Committee
Yes
5. Study Description
Brief Summary
Study aims: to compare two intervention strategies for bifurcation treatment - provisional T-stenting (PTS) with drug-eluting stent (sirolimus eluting), with kissing balloon inflation at the end of procedure - the best treatment strategy at the moment, with stenting of bifurcation lesions with dedicated bifurcation drug-eluting stent BiOSS Lym.
Detailed Description
The coronary bifurcation lesions pose a therapeutic problem with high rates of periprocedural complications, higher rates of in-stent restenosis and stent thrombosis. These are lesions where stenting is not superior in comparison to balloon angioplasty in regard to side branch. It was demonstrated many times, in literature and in daily practice, that angiographically high grade ostial side branch stenosis is not flow limiting and do not cause ischemia, therefore do not require treatment. From the other side, our own data with magnetic resonance imaging (MRI) before and after bifurcation percutaneous coronary intervention (PCI) demonstrated that occurrence of angiographic stenosis more than 70% in diameter is associated with periprocedural myonecrosis in the region of side branch. This fact puts a very important question about the mechanisms of this myonecrosis. If the jailed side branch has no significant flow limiting stenosis, but there is some degree of residual ischemia, which after some period of persistence could lead to myonecrosis, will mean that more aggressive treatment of ostial stenosis is needed. It is interesting that the strategy of treatment is very important, because techniques with second stent implantation (with primary purpose to limit side branch (SB) ischemia) are associated with higher grade of troponin increase. Of course this is association and not causality, despite that in randomized study it was confirmed also.
Even after the introduction of drug-eluting stents (DES) in the treatment of coronary bifurcation lesions, important basic problems remain. It was proposed that these problems are related to non-dedicated design of conventional stent intended for treatment of straight vessel segments. Thus any deformation of the stents during bifurcation implantation depends on the stent cell shape, size and material properties (11). To resolve these problems it was suggested to make dedicated bifurcation stents (1, 2, 11). However, the special "dedication" per se is not defined and unclear as terminology - the stent could be dedicated for patient fitting the anatomical characteristics of particular bifurcation point (vessel diameters, angulations), giving better hemodynamic conditions; or stent could be dedicated for operator to make the procedure quicker and safer, eliminating or limiting SB compromise. Probably the best option is the combination of both characteristics.
The currently available stents on the market generally target the second requirement. Three groups of stents are available at this moment - proximal main vessel (MV) stent (Axxess, Devax, USA), MV stenting across the SB with different designs making possible permanent access to SB and finally purely SB dedicated stents (Tryton, Sideguard, Biguard). Neither of these stents did not match proximal - distal MV size difference nor take into account between vessel angulations. The device success rate varies considerably (75% - 100%); however the study with 100% success was performed in only 11 patients. For all other devices the success rate is around 85%. The proximal MV stent and SB only stents require additional stent implantation for non-intended vessel. Stents designed to have permanent access to SB are implanted over 2 wires, which in reality makes the procedure more difficult and demanding rather to simplify it (which was the primary intention of those stents). The reasons are wires crisscrossing, wire-bias in proper orientation of device to SB (rotational and axial positioning). This, along with requirement of larger guide catheter size explains why the dedicated stents do not gain popularity in the interventional cardiology community.
The BiOSS Lim stent (Balton, Warsaw, Poland) is completely different from the above systems. The stent is designed to be user friendly: it tracked over one wire and its profile is quite low (1.08mm), which make it possible to implant it even through 5 Fr guiding catheter. The stent fits the bifurcation anatomy - it matches the proximal - distal diameters of the main vessel (MV); as it permits deformation in its mid-part it can adapt exactly on main vessel - main branch angle angle, making wide opening to SB. If the SB must be dilated the stent recrossing is very easy, because wider proximal and narrow distal parts give step-down at carina tip region, in this way self direct wire to SB. The proximal and distal parts of the stent work independently and SB could be safely dilated without need from kissing balloon inflation as no deformation of contralateral wall strut. This simplifies and shortens the procedure. And finally, the stent construction prevents carina displacement, as a basic mechanism of side branch compromise.
Study aims: to compare two intervention strategies for bifurcation treatment - provisional T-stenting (PTS) with drug-eluting stent (sirolimus eluting), with kissing balloon inflation at the end of procedure - the best treatment strategy at the moment, with stenting of bifurcation lesions with dedicated bifurcation drug-eluting stent BiOSS Lym.
6. Conditions and Keywords
Primary Disease or Condition Being Studied in the Trial, or the Focus of the Study
Coronary Bifurcation Stenosis
Keywords
coronary bifurcation stenosis, dedicated bifurcation stent, sirolymus, PTS, BiOSS Lym
7. Study Design
Primary Purpose
Treatment
Study Phase
Phase 4
Interventional Study Model
Single Group Assignment
Masking
None (Open Label)
Allocation
Randomized
Enrollment
60 (Anticipated)
8. Arms, Groups, and Interventions
Arm Title
BIOSS implantation
Arm Type
Active Comparator
Intervention Type
Device
Intervention Name(s)
BIOSS LIM implantation
Intervention Description
BIOSS LIM is a dedicated bifurcation stent system with sirolymus elution.
Intervention Type
Device
Intervention Name(s)
BIOSS Lim
Intervention Type
Device
Intervention Name(s)
CarloS
Primary Outcome Measure Information:
Title
Major adverse cardiac events (MACE)
Description
death, myocardial infarction (MI), target vessel revascularization (TVR)
Time Frame
12 months
Secondary Outcome Measure Information:
Title
Target lesion revascularization (TLR)
Description
Clinically driven revascularization rates.
Time Frame
12 months
10. Eligibility
Sex
All
Minimum Age & Unit of Time
20 Years
Maximum Age & Unit of Time
90 Years
Accepts Healthy Volunteers
No
Eligibility Criteria
Inclusion Criteria
Subject at least 18 years of age.
Subject able to verbally confirm understandings of risks, benefits of receiving PCI for true bifurcation lesions, and he/she or his/her legally authorized representative provides written informed consent prior to any study related procedure.
Target main branch lesion(s) located in a native coronary artery with diameter of ≥ 2.5 mm and ≤ 4.5 mm. Target side branch lesion(s) located in a native coronary artery with diameter of ≥ 2.0 mm.
Target lesion(s) amenable for PCI with balloon angioplasty of the side branch.
Exclusion Criteria
STEMI
Non-cardiac co-morbid conditions are present with life expectancy <1 year or that may result in protocol non-compliance (per site investigator's medical judgment).
Subjects who refuse to give informed consent.
Subjects with LVEF<30%
Subjects with moderate or severe degree valvular heart disease or primary cardiomyopathy
Contraindications for 12 months DAP
Central Contact Person:
First Name & Middle Initial & Last Name or Official Title & Degree
Dobrin Vassilev, MD, PhD
Phone
00359886846550
Email
dobrinv@gmail.com
First Name & Middle Initial & Last Name or Official Title & Degree
Kristiyan Ivanov, MD
Phone
00359884460101
Email
kristik@abv.bg
Facility Information:
Facility Name
Medica Cor Heart Hospital
City
Ruse
ZIP/Postal Code
7000
Country
Bulgaria
Individual Site Status
Recruiting
Facility Contact:
First Name & Middle Initial & Last Name & Degree
Dobrin Vassilev, MD, PhD
Phone
00359886846550
Email
dobrinv@gmail.com
First Name & Middle Initial & Last Name & Degree
Kristiyan Ivanov, MD
Phone
00359884460101
Email
kristik@abv.bg
12. IPD Sharing Statement
Learn more about this trial
BIfurcation Optimal Treatment Strategy With LYMus Eluting Dedicated Bifurcation Versus Convention Stent Randomized Study
We'll reach out to this number within 24 hrs