search
Back to results

Does Endoscope Position Detecting Unit Facilitate a Complete Colonoscopy Examination (UPD-3)

Primary Purpose

Colorectal Neoplasms

Status
Unknown status
Phase
Phase 3
Locations
China
Study Type
Interventional
Intervention
UPD guidance
Sponsored by
Chinese University of Hong Kong
About
Eligibility
Locations
Arms
Outcomes
Full info

About this trial

This is an interventional diagnostic trial for Colorectal Neoplasms focused on measuring magnetic endoscope imaging, colonoscopy, caecal intubation

Eligibility Criteria

18 Years - undefined (Adult, Older Adult)All SexesDoes not accept healthy volunteers

Inclusion Criteria:

  • Aged 18 years or above
  • American Society of Anaesthesiologist (ASA) grading I-III
  • Scheduled for elective colonoscopy

Exclusion Criteria:

  • Previous colonic resection
  • Refuse to consent to participate
  • History of allergy to propofol or alfentanil
  • Has a pacemaker in situ
  • Pregnant lady

Sites / Locations

  • Alice Ho Miu Ling Nethersole HospitalRecruiting
  • Prince of Wales HospitalRecruiting

Arms of the Study

Arm 1

Arm 2

Arm Type

Experimental

No Intervention

Arm Label

UPD guided group

non-UPD guided group

Arm Description

Both the colonoscopist and assistant will be viewing the imager screen during the whole procedure.

Conventional colonoscopy would be done without image guidance.

Outcomes

Primary Outcome Measures

caecal intubation rate
Caeal intubation is the landmark for complete colonoscopy. Caecal intubation would be documented after each procedure. The caecal intubation rate with or without UPD guidance would be compared. The result would provide information whether the UPD device can faciliate complete colonoscopy.

Secondary Outcome Measures

Caecal intubation time
Comparison of caecal intubaton time between UPD guided and non-UPD guided group would provide information on whether UPD device faciliate complete colonoscopy.

Full Information

First Posted
June 20, 2011
Last Updated
September 13, 2011
Sponsor
Chinese University of Hong Kong
search

1. Study Identification

Unique Protocol Identification Number
NCT01434199
Brief Title
Does Endoscope Position Detecting Unit Facilitate a Complete Colonoscopy Examination
Acronym
UPD-3
Official Title
Does Endoscope Position Detecting Unit Facilitate Caecal Intubation? A Randomized Controlled Trial
Study Type
Interventional

2. Study Status

Record Verification Date
September 2011
Overall Recruitment Status
Unknown status
Study Start Date
July 2011 (undefined)
Primary Completion Date
July 2012 (Anticipated)
Study Completion Date
July 2012 (Anticipated)

3. Sponsor/Collaborators

Responsible Party, by Official Title
Principal Investigator
Name of the Sponsor
Chinese University of Hong Kong

4. Oversight

Data Monitoring Committee
Yes

5. Study Description

Brief Summary
As the incidence of colorectal cancer (CRC) has been rapidly rising in Asian countries, more and more screening colonoscopies are now being performed for prevention or early detection of this fatal disease. Complete colonoscopy as indicated by caecal intubation is essential to make it a reliable screening tool for colorectal cancer or polyps. Cecal intubation rate is highly variable and dependent on individual experience. Colonic looping is the commonest cause of incomplete colonoscopy. Magnetic endoscope imaging (MEI) is a non-radiological imaging technique to provide real time, three-dimensional image and position of the colonoscope during the procedure. It may facilitate straightening of colonic loops and hence cecal intubation. The investigators aim to evaluate the benefit of MEI in term of cecal intubation rate across endoscopists of all levels of experience by making use of the newly developed Endoscopy Position Detecting Unit (UPD-3)by Olympus Optical Co, Ltd, Japan. The investigators propose to conduct a prospective randomized controlled trial to compare the caecal intubation rate of colonoscopy being performed with and without UPD-3 guidance. Colonoscopies performed by endoscopists with different level of experience will be randomized to UPD-3 guided group or conventional group (no UPD-3 guidance). Patient controlled sedation (PCS) containing propofol and alfentanil will be given to all patients. The investigators hypothesize that UPD-3 guided colonoscopy is associated with high caecal intubation rate (complete colonoscopy), shorter time to caecum, less patient pain and lower sedative medication requirement. A high caecal intubation rate facilitates a reliable colonoscopy screening. Decreased colonic looping and shorter time to caecum may reduce patient discomfort during the procedure. It may also facilitate learning and acquiring the skill of colonoscopy in trainees.
Detailed Description
Hypothesis UPD guided colonoscopy improves cecal intubation rate. Methods Trial design This is a prospective randomized controlled trial comparing the cecal intubation rate of colonoscopy being performed with and without UPD guidance by endoscopists of different levels of experience. The trial will be conducted in the Endoscopy Unit of a university affiliated hospital. Patients who will have elective colonoscopy in the Endoscopy Unit during the study period, and meet the following inclusion criteria are recruited. The colonoscopy will be done by 6 dedicated endoscopists with different levels of experience in performing colonoscopy. Interventions UPD-3 and the specific colonoscope with an in-built magnetic imaging facility (Olympus Optical Co, Ltd, Japan) will be used in all examinations. A mobile sensor will be attached to the assistant's hand, so that the hand position in relation to the colonoscope could be shown in the imager screen. Patient controlled sedation (PCS) will be given to all patients. It is delivered by means of Graseby 3300 PCA pump (Graseby Medical Ltd), using a mixture of propofol (200mg in 20ml) and alfentanil (0.5mg in 1ml) in a 25-ml syringe. The drugs will be delivered in response to pressure on a hand-held button controlled by the patient. Each bolus (0.5ml) delivers 4.8mg propofol and 12microgram alfentanil. No loading dose was used and the lock-out time of the PCA machine was set at zero. All patients will be instructed in the use of the hand-held button before colonoscopy. Nasal oxygen (2l/min) will be given to all patients, and oxygen saturation and blood pressure will be continuously monitored throughout the procedure. The procedure will be randomized to either with the colonoscopist viewing the imager screen or not. UPD guided group: Both the colonoscopist and assistant will be viewing the imager screen during the whole procedure. Information about colonoscopy looping will interpreted and documented by the colonoscopist. Anterior-position view is the standard reference. When abdominal compression is required, the assistant nurse should have the hand held probe attached, such that abdominal compression is guided by the image. Conventional group (non- UPD guided): The imager screen will be turned to the other side such that both the colonoscopist and assistant is blind to UPD images. When the colonoscopist encountered looping as defined by paradoxical movement of the tip or disproportionate advancement in endoscopic view to the shaft insertion, the colonoscopist is requested to estimate the type of loop formed. The images will be captured for later interpretation. The primary outcome is cecal intubation rate. Cecal intubation is defined as visualization of appendix orifice and ileocaecal valve, procedure started by a trainee and taken over by supervisor before caecal intubation is regarded as incomplete. Sample size The cecal intubation rate could be increased by at least 11% for trainee in a randomized trial by Shah [14] and 16% for trainee and experienced endoscopist in another trial [15]. Since the overall cecal intubation rate in our Endoscopy unit without UPD guide is at least 90% already, the investigators expect a modest benefit from UPD guidance. Assume a difference of 5% in caecal intubation rate (from 90% in conventional group to 95% in the UPD guided group) with a power of 80% and a type I error of 5%, 2 sided analysis, 435 patients will be needed in each group. Thus a sample size of 870 patients is required. Randomization Informed consent will be obtained before colonoscopy in the Endoscopy Unit, if the patient fulfils the inclusion criteria. Block randomization will be done on a 1:1 basis, to ensure equal number of UPD guided or conventional colonoscopies are done by each endoscopist. A sealed non-opaque envelope (produced according to the computer generated random sequence) will be opened to determine the appropriate limb of entry before scope insertion. It is not possible to blind the study. Statistical analysis The data will be analyzed according to the intention-to-treat principle. The chi-squared test (or Fisher's exact test when appropriate), Student's t-test, and Mann-Whitney U test will be used to compare categorical, parametric, and non-parametric data, respectively. A P value <0.05 is considered statistically significant. Planned interim analysis will be conducted after recruiting 50% of patients. Data collection Data will be collected by the in-charged endoscopist and assistant after each procedure in a standardized data sheet. Accrual rate It is expected that about 20 cases per week will be recruited for randomization. The study could be finished in around 1 year time.

6. Conditions and Keywords

Primary Disease or Condition Being Studied in the Trial, or the Focus of the Study
Colorectal Neoplasms
Keywords
magnetic endoscope imaging, colonoscopy, caecal intubation

7. Study Design

Primary Purpose
Diagnostic
Study Phase
Phase 3
Interventional Study Model
Parallel Assignment
Masking
None (Open Label)
Allocation
Randomized
Enrollment
870 (Anticipated)

8. Arms, Groups, and Interventions

Arm Title
UPD guided group
Arm Type
Experimental
Arm Description
Both the colonoscopist and assistant will be viewing the imager screen during the whole procedure.
Arm Title
non-UPD guided group
Arm Type
No Intervention
Arm Description
Conventional colonoscopy would be done without image guidance.
Intervention Type
Procedure
Intervention Name(s)
UPD guidance
Other Intervention Name(s)
Magnetic endoscope imaging (MEI)
Intervention Description
A real time, three-dimensional image and position of the colonoscope would be provided to the endoscopist during the procedure.
Primary Outcome Measure Information:
Title
caecal intubation rate
Description
Caeal intubation is the landmark for complete colonoscopy. Caecal intubation would be documented after each procedure. The caecal intubation rate with or without UPD guidance would be compared. The result would provide information whether the UPD device can faciliate complete colonoscopy.
Time Frame
10minutes in average after starting the procedure
Secondary Outcome Measure Information:
Title
Caecal intubation time
Description
Comparison of caecal intubaton time between UPD guided and non-UPD guided group would provide information on whether UPD device faciliate complete colonoscopy.
Time Frame
10 minutes in average after starting the procedure

10. Eligibility

Sex
All
Minimum Age & Unit of Time
18 Years
Accepts Healthy Volunteers
No
Eligibility Criteria
Inclusion Criteria: Aged 18 years or above American Society of Anaesthesiologist (ASA) grading I-III Scheduled for elective colonoscopy Exclusion Criteria: Previous colonic resection Refuse to consent to participate History of allergy to propofol or alfentanil Has a pacemaker in situ Pregnant lady
Central Contact Person:
First Name & Middle Initial & Last Name or Official Title & Degree
Sophie SF Hon, MD
Phone
852-2632 1495
Email
honsf@surgery.cuhk.edu.hk
First Name & Middle Initial & Last Name or Official Title & Degree
James YW Lau, MD
Phone
852-2632 1441
Email
laujyw@surgery.cuhk.edu.hk
Overall Study Officials:
First Name & Middle Initial & Last Name & Degree
Sophie SF Hon, MD
Organizational Affiliation
Chinese University of Hong Kong
Official's Role
Principal Investigator
Facility Information:
Facility Name
Alice Ho Miu Ling Nethersole Hospital
City
Hong Kong
State/Province
Hong Kong
Country
China
Individual Site Status
Recruiting
Facility Contact:
First Name & Middle Initial & Last Name & Degree
Sophie SF Hon, MD
Phone
852-2632 1495
Email
honsf@surgery.cuhk.edu.hk
Facility Name
Prince of Wales Hospital
City
Hong Kong
State/Province
Hong Kong
Country
China
Individual Site Status
Recruiting
Facility Contact:
First Name & Middle Initial & Last Name & Degree
Sophie SF Hon, MD
Phone
852-2632 1495
Email
honsf@surgery.cuhk.edu.hk

12. IPD Sharing Statement

Citations:
PubMed Identifier
12024136
Citation
Shah SG, Brooker JC, Thapar C, Suzuki N, Williams CB, Saunders BP. Effect of magnetic endoscope imaging on patient tolerance and sedation requirements during colonoscopy: a randomized controlled trial. Gastrointest Endosc. 2002 Jun;55(7):832-7. doi: 10.1067/mge.2002.124097.
Results Reference
background
PubMed Identifier
11095259
Citation
Shah SG, Brooker JC, Williams CB, Thapar C, Saunders BP. Effect of magnetic endoscope imaging on colonoscopy performance: a randomised controlled trial. Lancet. 2000 Nov 18;356(9243):1718-22. doi: 10.1016/S0140-6736(00)03205-0.
Results Reference
background

Learn more about this trial

Does Endoscope Position Detecting Unit Facilitate a Complete Colonoscopy Examination

We'll reach out to this number within 24 hrs