search
Back to results

New Anastomotic Device for End to End Vascular Anastomosis in the Treatment of Peripheral Vascular Disease (VJ)

Primary Purpose

Peripheral Vascular Disease, Femoral Occlusive Disease, Femoropopliteal Occlusive Disease

Status
Unknown status
Phase
Not Applicable
Locations
Switzerland
Study Type
Interventional
Intervention
mechanical anastomosis without suture
Sponsored by
Ab Medica Spa
About
Eligibility
Locations
Outcomes
Full info

About this trial

This is an interventional treatment trial for Peripheral Vascular Disease

Eligibility Criteria

18 Years - undefined (Adult, Older Adult)All SexesDoes not accept healthy volunteers

Inclusion Criteria:

  • Patients with peripheral vascular disease requiring vascular bypass (Fontaine stage 2B-3)

Exclusion Criteria:

  • Pregnant women
  • Patient requiring further surgery at the same time
  • A patient with acute vascular occlusion.
  • Hemodynamically unstable patient before surgery

Sites / Locations

  • Service de Chirurgie cardio-vasculaire CHUVRecruiting

Outcomes

Primary Outcome Measures

Incidence of complications using Vascular Join
The objective is to achieve a vascular bypass using the mechanical device Vascular Join and define the incidence of vascular complications (bleeding, infection and occlusion) in the postoperative 7 days (or until discharge), as well as primary and secondary permeability bypass after 6 months. The incidence is compared with the Vascular standard technique (running or interrupted suture).

Secondary Outcome Measures

Full Information

First Posted
January 12, 2012
Last Updated
February 8, 2012
Sponsor
Ab Medica Spa
Collaborators
Centre Hospitalier Universitaire Vaudois
search

1. Study Identification

Unique Protocol Identification Number
NCT01514916
Brief Title
New Anastomotic Device for End to End Vascular Anastomosis in the Treatment of Peripheral Vascular Disease
Acronym
VJ
Official Title
Evaluation of a Mechanical System (Vascular Join) Facilitating Arterial Anastomoses During Peripheral Vascular Surgery (Bypass).
Study Type
Interventional

2. Study Status

Record Verification Date
February 2012
Overall Recruitment Status
Unknown status
Study Start Date
undefined (undefined)
Primary Completion Date
undefined (undefined)
Study Completion Date
undefined (undefined)

3. Sponsor/Collaborators

Responsible Party, by Official Title
Sponsor
Name of the Sponsor
Ab Medica Spa
Collaborators
Centre Hospitalier Universitaire Vaudois

4. Oversight

Data Monitoring Committee
Yes

5. Study Description

Brief Summary
The medical device "Vascular Join" represents a new anastomotic technology that should reduce the inter-surgeons variability in anastomosis construction and increase the performances in terms of results. It allows a perfect mechanical anastomosis without suture, avoiding the disadvantages of operation length and difficulty of the act, thrombosis, clamping and embolism. The "Vascular Join" creates automatically the connection between the vein or prosthesis at both ends and bridging the artery while preventing the passage of the needle and suture through the vessel wall and clamping pressure. This makes it very easy to construct a vascular anastomosis using the endoscopic technique less traumatic for the patient, lessen the pain of the patient, thereby reducing health care costs by reducing the length of hospital stay. No part of the device is in contact with the patient's blood because the whole system remains in the thickness of the arterial wall and outside the vessel. Thus, the formation of intimal hyperplasia is greatly diminished and the risk of occlusion of the anastomosis is less than the currently available risk when a suture is used. This risk is shown by studies on animals in labs, with a mean follow up of 12 months. The Vascular Join creates a perfect congruence of anastomosed vessels because it allows a perfect match between each vascular tunic. The medical device Vascular Join has been designed in order to: Reduce the suture time; Reduce the risk of occlusion of vein after the surgical process; Avoid the contact risk between the external material steel (surgical needle) and blood; Standardize the quality of anastomoses independently of the skill of the surgeon.
Detailed Description
The Vascular Join consists of two symmetrical parts, called Vessel Rings, each of which is fixed to the extremity of the two conduits being joined together. A third ring, called Coupler Ring, keeps the two rings together with a snap-on system and guarantees the continuity of the severed conduit in an end-to-end configuration. Each ring is made within a cylinder-type steel AISI 316L. The circular shape of the Vessel rings, the inner part in particular, provides a natural physiologic vascular reconstruction reducing the risk of thrombosis and myointimal hyperplasia at the anastomotic site. We propose to evaluate the ease of use, efficiency, security of the "Vascular Join" and long-term results (6 months) in patients with peripheral vascular disease requiring vascular bypass. Each patient has a proximal anastomosis and distal anastomosis performed with the "Vascular Join". Next, measure the flow in the bypass through an ultrasonic flow meter. The objective is to achieve a vascular bypass using the mechanical device described above and to define the incidence of major and minor vascular complications in the postoperative 7 days (or until discharge), as well as primary and secondary permeability bypass after 6 months. What we define as major vascular complications are death, stroke, acute occlusion, partial occlusion, and reoperation for redo the mechanical anastomosis. We define as minor complications residual pain, and bleeding. In the case of partial or complete failure of the mechanical suture, the surgeon can add points of suture or performing anastomosis with the traditional technique. After 6 months, a Doppler will allow us to compare to each patient, the morphology of the anastomoses performed with the "Vascular Join," and the permeability of the bypass. The results will be compared to historical results of primary and secondary permeability present in the literature. The 2 main objectives of this study are to assess if the device still works after 6 months (so called device's performance) and if it is as safe as standard technique (running or interrupted suture) in terms of incidence of complications as bleeding, infection and occlusion. Simple size has therefore been calculated in terms of equivalence risk. In this case the null hypothesis specify that the success rate Pc in the standard treatment is higher than the success rate PE in the vascular join treatment by at least some amount ß. The alternative hypothesis specifies that PC - PE < ß, which implies the 2 therapies are equivalent. The following formula provides the required number of patients for such a trial: Ho: PC >(or =) PE + ß vs H1: PC <(or =) PE + ß . Because, taking historical data as reference, the incidence of all complications in peripheral bypasses could be as high as 50% at 6 months, the number of 30 patients was selected. The post-operative treatment and remote monitoring of patients remained unchanged (Aspirin 100 mg/d and control angiological at 3 and 6 months). Patient's follow-up is the same as any other patient receiving femoral artery bypass, which means physical examination and Doppler ultrasound of the bypass before the discharge, 1, 3 and 6 months after the procedure. If the patient misses the scheduled control, the PI will apply the procedure in use at the Cardiovascular Surgery Dpt to contact him, which includes phone calls to the patient, the contact person he/her identified at the admission and to the GP.

6. Conditions and Keywords

Primary Disease or Condition Being Studied in the Trial, or the Focus of the Study
Peripheral Vascular Disease, Femoral Occlusive Disease, Femoropopliteal Occlusive Disease, Aortoiliac Atherosclerosis

7. Study Design

Primary Purpose
Treatment
Study Phase
Not Applicable
Interventional Study Model
Single Group Assignment
Masking
None (Open Label)
Allocation
N/A
Enrollment
30 (Anticipated)

8. Arms, Groups, and Interventions

Intervention Type
Device
Intervention Name(s)
mechanical anastomosis without suture
Intervention Description
The Vascular Join device is intended to be used to create sutureless end-to-end anastomosis between an artery and a venous or synthetic graft conduit. Any type of e-PTFE and Dacron conduits can be used.
Primary Outcome Measure Information:
Title
Incidence of complications using Vascular Join
Description
The objective is to achieve a vascular bypass using the mechanical device Vascular Join and define the incidence of vascular complications (bleeding, infection and occlusion) in the postoperative 7 days (or until discharge), as well as primary and secondary permeability bypass after 6 months. The incidence is compared with the Vascular standard technique (running or interrupted suture).
Time Frame
six month

10. Eligibility

Sex
All
Minimum Age & Unit of Time
18 Years
Accepts Healthy Volunteers
No
Eligibility Criteria
Inclusion Criteria: Patients with peripheral vascular disease requiring vascular bypass (Fontaine stage 2B-3) Exclusion Criteria: Pregnant women Patient requiring further surgery at the same time A patient with acute vascular occlusion. Hemodynamically unstable patient before surgery
Central Contact Person:
First Name & Middle Initial & Last Name or Official Title & Degree
Piergiorgio Tozzi, Dr. PD&MER
Phone
+41213147367
Email
Piergiorgio.Tozzi@chuv.ch
Overall Study Officials:
First Name & Middle Initial & Last Name & Degree
Cosimo Puttilli, Eng.
Organizational Affiliation
Ab Medica Spa
Official's Role
Study Director
Facility Information:
Facility Name
Service de Chirurgie cardio-vasculaire CHUV
City
Lausanne
ZIP/Postal Code
CH-1011
Country
Switzerland
Individual Site Status
Recruiting

12. IPD Sharing Statement

Citations:
PubMed Identifier
16859919
Citation
Tozzi P, Borghi E, Haesler E, Siniscalchi G, Motti A, Hayoz D, von Segesser LK. Progress in cardiovascular anastomoses: will the vascular join replace Carrel's technique? Eur J Cardiothorac Surg. 2006 Sep;30(3):425-30. doi: 10.1016/j.ejcts.2006.05.029. Epub 2006 Jul 20.
Results Reference
background
PubMed Identifier
17669755
Citation
Ferrari E, Tozzi P, von Segesser LK. The Vascular Join: a new sutureless anastomotic device to perform end-to-end anastomosis. Preliminary results in an animal model. Interact Cardiovasc Thorac Surg. 2007 Feb;6(1):5-8. doi: 10.1510/icvts.2006.137943. Epub 2006 Nov 20.
Results Reference
background
PubMed Identifier
11565736
Citation
Tozzi P, Solem JO, Boumzebra D, Mucciolo A, Genton CY, Chaubert P, von Segesser LK. Is the GraftConnector a valid alternative to running suture in end-to-side coronary arteries anastomoses? Ann Thorac Surg. 2001 Sep;72(3):S999-1003. doi: 10.1016/s0003-4975(01)02953-8.
Results Reference
background

Learn more about this trial

New Anastomotic Device for End to End Vascular Anastomosis in the Treatment of Peripheral Vascular Disease

We'll reach out to this number within 24 hrs