NG PROMUS Stent System for the Treatment of Atherosclerotic Coronary Lesions

Primary Purpose

Atherosclerosis, Coronary Artery Disease

Status
Completed
Phase
Not Applicable
Locations
International
Study Type
Interventional
Intervention
Percutaneous coronary intervention (NG PROMUS)
Sponsored by
Boston Scientific Corporation
About
Eligibility
Locations
Arms
Outcomes
Full info

About this trial

This is an interventional treatment trial for Atherosclerosis focused on measuring drug eluting coronary stent

Eligibility Criteria

18 Years - undefined (Adult, Older Adult)All SexesDoes not accept healthy volunteers

Clinical Inclusion Criteria:

  1. Subject must be at least 18 years of age
  2. Subject (or legal guardian) understands the trial requirements and the treatment procedures and provides written informed consent before any trial-specific tests or procedures are performed
  3. Subject is eligible for percutaneous coronary intervention (PCI)
  4. Subject has symptomatic coronary artery disease with objective evidence of ischemia or silent ischemia
  5. Subject is an acceptable candidate for coronary artery bypass grafting (CABG)
  6. Subject is willing to comply with all protocol-required follow-up evaluation

Angiographic Inclusion Criteria:

  1. Target lesion(s) must be located in a native coronary artery with a visually estimated reference vessel diameter (RVD) ≥2.50 mm and ≤4.0 mm
  2. Target lesion(s) length must be ≤34 mm (by visual estimate)
  3. Target lesion(s) must have visually estimated stenosis ≥50% and <100% with thrombolysis in Myocardial Infarction (TIMI) flow >1 and one of the following (stenosis ≥70%, abnormal fractional flow reserve (FFR), abnormal stress test or imaging stress test, or elevated biomarkers) prior to procedure
  4. Coronary anatomy is likely to allow delivery of a study device to the target lesions(s)
  5. The first lesion treated must be successfully pre-dilated/pretreated Note: Successful pre-dilatation/pretreatment refers to dilatation with a balloon catheter of appropriate length and diameter, or pretreatment with directional or rotational coronary atherectomy, laser or cutting/scoring balloon with no greater than 50% residual stenosis and no dissection greater than National Heart, Lung, Blood Institute (NHLBI) type C.

Clinical Exclusion Criteria:

  1. Subject has clinical symptoms and/or electrocardiogram (ECG) changes consistent with acute ST elevation MI (STEMI)
  2. Subject has cardiogenic shock, hemodynamic instability requiring inotropic or mechanical circulatory support, intractable ventricular arrhythmias, or ongoing intractable angina
  3. Subject has received an organ transplant or is on a waiting list for an organ transplant
  4. Subject is receiving or scheduled to receive chemotherapy within 30 days before or after the index procedure
  5. Planned PCI (including staged procedures) or CABG after the index procedure
  6. Subject previously treated at any time with intravascular brachytherapy
  7. Subject has a known allergy to contrast (that cannot be adequately premedicated) and/or the trial stent system or protocol-required concomitant medications (e.g., platinum, platinum-chromium alloy, stainless steel, everolimus or structurally related compounds, polymer or individual components, all P2Y12 inhibitors, or aspirin)
  8. Subject has one of the following (as assessed prior to the index procedure):Other serious medical illness (e.g., cancer, congestive heart failure) with estimated life expectancy of less than 24 months; Current problems with substance abuse (e.g., alcohol, cocaine, heroin, etc.);Planned procedure that may cause non-compliance with the protocol or confound data interpretation
  9. Subject is receiving chronic (≥72 hours) anticoagulation therapy (i.e., heparin, coumadin) for indications other than acute coronary syndrome
  10. Subject has a platelet count <100,000 cells/mm3 or >700,000 cells/mm3
  11. Subject has a white blood cell (WBC) count < 3,000 cells/mm3
  12. Subject has documented or suspected liver disease, including laboratory evidence of hepatitis
  13. Subject is on dialysis or has baseline serum creatinine level >2.0 mg/dL (177µmol/L)
  14. Subject has a history of bleeding diathesis or coagulopathy or will refuse blood transfusions
  15. Subject has had a history of cerebrovascular accident (CVA) or transient ischemic attack (TIA) within the past 6 months
  16. Subject has an active peptic ulcer or active gastrointestinal (GI) bleeding
  17. Subject has signs or symptoms of active heart failure (i.e., NYHA class IV) at the time of the index procedure
  18. Subject is participating in another investigational drug or device clinical trial that has not reached its primary endpoint
  19. Subject intends to participate in another investigational drug or device clinical trial within 12 months after the index procedure
  20. Subject with known intention to procreate within 12 months after the index procedure (women of child-bearing potential who are sexually active must agree to use a reliable method of contraception from the time of screening through 12 months after the index procedure)
  21. Subject is a woman who is pregnant or nursing (a pregnancy test must be performed within 7 days prior to the index procedure in women of child-bearing potential)

Angiographic Exclusion Criteria:

  1. Planned treatment of more than 3 lesions.
  2. Planned treatment of lesions in more than 2 major epicardial vessels
  3. Planned treatment of a single lesion with more than 1 stent
  4. Subject has 2 target lesions in the same vessel that are separated by less than 15 mm (by visual estimate)
  5. Target lesion(s) is located in the left main
  6. Target lesion(s) is located within 3 mm of the origin of the left anterior descending (LAD) coronary artery or left circumflex (LCx) coronary artery by visual estimate.
  7. Target lesion(s) is located within a saphenous vein graft or an arterial graft
  8. Target lesion(s) will be accessed via a saphenous vein graft or arterial graft
  9. Target lesion(s) with a TIMI flow 0 (total occlusion) or TIMI flow 1 prior to guide wire crossing
  10. Target lesion(s) treated during the index procedure that involves a complex bifurcation (e.g., bifurcation lesion requiring treatment with more than 1 stent)
  11. Target lesion(s) is restenotic from a previous stent implantation or study stent would overlap with a previous stent
  12. Subject has unprotected left main coronary artery disease (>50% diameter stenosis)
  13. Subject has been treated with any type of PCI (i.e., balloon angioplasty, stent, cutting balloon atherectomy) within 24 hours prior to the index procedure
  14. Thrombus, or possible thrombus, present in the target vessel (by visual estimate)

Sites / Locations

  • Fremantle Hospital
  • Mercy Angiography Unit, Ltd. Mercy Hospital
  • Auckland City Hospital
  • North Shore Hospital
  • Ascot Angiography
  • Christchurch
  • Middlemore Hospital
  • National University Hospital Singapore
  • National Heart Center Singapore

Arms of the Study

Arm 1

Arm Type

Experimental

Arm Label

NG PROMUS stent

Arm Description

Single-arm treatment group receiving interventional NG PROMUS study stent

Outcomes

Primary Outcome Measures

Technical Success Rate
Technical success is defined as successful delivery and deployment of the study stent to the target lesion, without balloon rupture or stent embolization, and post-procedure diameter stenosis of <30% assessed in 2 near-orthogonal projections with TIMI 3 flow in the target lesion, as visually assessed by the physician

Secondary Outcome Measures

Target Lesion Revascularization (TLR) Rate
Target lesion revascularization is any ischemia-driven repeat percutaneous intervention, to improve blood flow, of the successfully treated target lesion or bypass surgery of the target vessel with a graft distally to the successfully treated target lesion. A TLR will be considered as ischemia-driven if the target lesion diameter stenosis is >/= 50% by QCA and there is presence of clinical or functional ischemia which cannot be explained by other coronary or graft lesions. Clinical or functional ischemia is any of the following: The subject has a positive functional study corresponding to the area served by the target lesion. The subject has ischemic ECG changes at rest in a distribution consistent with the target vessel. The subject has ischemic symptoms referable to the target lesion. A TLR will be considered as ischemia-driven if the lesion diameter stenosis is >/= 70% by QCA even in the absence of clinical or functional ischemia.
Target Lesion Failure (TLF) Rate
Target lesion failure is any ischemia-driven revascularization of the target lesion, MI (Q-wave and non-Q-wave) related to the target vessel, or (cardiac) death. For the purposes of this protocol, if it cannot be determined with certainty whether the MI was related to the target vessel, it will be considered a TLF. The MI definition used for Target Lesion Failure was the PLATINUM MI definition.
Target Vessel Revascularization (TVR) Rate
Target vessel revascularization is defined as a TLR or a TVR remote. Target vessel revascularization remote is any ischemia-driven repeat percutaneous intervention, to improve blood flow, or bypass surgery of not previously existing lesions diameter stenosis >/= 50% by QCA in the target vessel, excluding the target lesion. A TVR will be considered ischemia-driven if the target vessel diameter stenosis is >/= 50% by QCA and any of the following are present: The subject has a positive functional study corresponding to the area served by the target vessel. The subject has ischemic ECG changes at rest in a distribution consistent with the target vessel. The subject has ischemic symptoms referable to the target vessel. A TVR will also be considered as ischemia-driven if the lesion diameter stenosis is >/=70% even in the absence of clinical or functional ischemia.
Target Vessel Failure (TVF) Rate
Target vessel failure is any ischemia-driven revascularization of the target vessel, MI (Q-wave and non-Q-wave) related to the target vessel or death related to the target vessel. For the purposes of this protocol, if it cannot be determined with certainty whether the MI or death was related to the target vessel, it will be considered a TVF. The MI definition used was the PLATINUM MI definition.
Myocardial Infarction (MI, Q-wave and Non-Q-wave) Rate
MI will be defined according to the PLATINUM Definition of MI with evidence pre-specified for i) Spontaneous, ii) PCI-related, iii) CABG related, and iv) autopsy evidence criteria.
Cardiac Death Rate
Cardiac death is defined as death due to any of the following. Acute MI Cardiac perforation/pericardial tamponade Arrhythmia or conduction abnormality CVA through hospital discharge or CVA suspected of being related to the procedure Death due to complication of the procedure, including bleeding, vascular repair, transfusion reaction, or bypass surgery Any death in which a cardiac cause cannot be excluded
Non-cardiac Death Rate
Non-cardiac death is defined as a death not due to any of the following: Acute MI Cardiac perforation/pericardial tamponade Arrhythmia or conduction abnormality CVA through hospital discharge or CVA suspected of being related to the procedure Death due to complication of the procedure, including bleeding, vascular repair, transfusion reaction, or bypass surgery Any death in which a cardiac cause cannot be excluded
All Death Rate
Death is categorized as cardiac or non-cardiac deaths.
Cardiac Death or MI Rate
Any cardiac death or MI event meeting the criteria defined for a cardiac death or MI. MI definition used was the PLATINUM definition for MI.
All Death or MI Rate
Any all-cause mortality event or MI meeting the criteria defined for any death or MI. MI definition used was the PLATINUM definition for MI.
All Death/MI/TVR Rate
Any event meeting the pre-specified criteria for any death, MI, or TVR. MI definition used was the PLATINUM definition for MI.
Stent Thrombosis Rate (by Academic Research Consortium [ARC] Definitions)
Stent thrombosis should be reported as a cumulative value at the different time points and with the different separate time points. Time 0 is defined as the time point after the guide catheter has been removed and the patient left the catheterization lab. Timing: Acute stent thrombosis*: 0 24 hours after stent implantation Subacute stent thrombosis*: >24 hours to 30 days after stent implantation Late stent thrombosis: >30 days to 1 year after stent implantation Very late stent thrombosis: >1 year after stent implantation * Acute/subacute can also be replaced by early stent thrombosis. Early stent thrombosis is 0 30 days. Stent thrombosis may be defined as: Confirmed/definite Probable Possible Confirmed/Definite (is considered either angiographic confirmed or pathologic confirmed)
Clinical Procedural Success Rate
Clinical procedural success is post-procedure diameter stenosis <30% in 2 near-orthogonal projections with TIMI 3 flow in all target lesions, as visually assessed by the physician, without the occurrence of in-hospital MI, TVR, or cardiac death. MI definition used was the PLATINUM definition for MI.
In-stent Percent Diameter Stenosis (%DS)
As measured by an independent angiographic core laboratory using quantitative coronary angiography (QCA), the % diameter stenosis of the in-stent region. Percent diameter stenosis: Relative changes that occur in the percent diameter stenosis are provided by the following relationship: % diameter stenosis= (1-[Minimum Lumen Diameter/Reference diameter]) x 100.
In-segment Percent Diameter Stenosis (%DS)
As measured by an independent angiographic core laboratory using quantitative coronary angiography (QCA), the % diameter stenosis of the in-segment region (in-segment includes the stented region and 5 mm edge regions). Percent diameter stenosis: Relative changes that occur in the percent diameter stenosis are provided by the following relationship: % diameter stenosis= (1-[Minimum Lumen Diameter/Reference diameter]) x 100.
In-stent Minimum Lumen Diameter (MLD)
As measured by an independent angiographic core laboratory using quantitative coronary angiography (QCA); the minimum lumen diameter (MLD) measured at the in-stent region. The MLD is the mean minimum lumen diameter (mm) from 2 orthogonal views.
In-segment Minimum Lumen Diameter (MLD)
As measured by an independent angiographic core laboratory using quantitative coronary angiography (QCA); the minimum lumen diameter (MLD) measured at the in-segment region (in-segment includes the stented region and 5 mm edge regions). The MLD is the mean minimum lumen diameter (mm) from 2 orthogonal views.
Acute Gain
Acute gain, as measured by angiographic core lab
Vessel Area
As measured by IVUS, the mean vessel area (mm2).
Stent Area
As measured by IVUS, the area of the stent.
Lumen Area
As measured by IVUS, the area of the lumen.
Vessel Volume
As measured by IVUS, the volume of the vessel.
Stent Volume
As measured by IVUS, the volume of the stent.
Lumen Volume
As measured by IVUS, the volume of the lumen.
Incomplete Apposition
Incomplete apposition rate, as measured by the IVUS core lab. Binary assessment of presence of one or more stent struts separated from the vessel wall as detected through intravascular ultrasound (IVUS).
Percent Net Volume Obstruction
The percentage of volume obstruction, as measured by the IVUS core lab.
Longitudinal Stent Deformation
Longitudinal stent deformation, evidenced by longitudinal compression or elongation, as the result of crossing a newly deployed stent with a second device, (such as a balloon catheter, stent system or IVUS catheter), causing the second device to become caught on the stent when the second device is advanced or retracted.

Full Information

First Posted
October 5, 2012
Last Updated
March 20, 2014
Sponsor
Boston Scientific Corporation
search

1. Study Identification

Unique Protocol Identification Number
NCT01703000
Brief Title
NG PROMUS Stent System for the Treatment of Atherosclerotic Coronary Lesions
Official Title
NG PROMUS: A Prospective, Multicenter Trial to Assess the NG PROMUS Everolimus-Eluting Platinum Chromium Coronary Stent System (NG PROMUS Stent System) for the Treatment of Atherosclerotic Lesion(s)
Study Type
Interventional

2. Study Status

Record Verification Date
March 2014
Overall Recruitment Status
Completed
Study Start Date
November 2012 (undefined)
Primary Completion Date
March 2013 (Actual)
Study Completion Date
March 2013 (Actual)

3. Sponsor/Collaborators

Responsible Party, by Official Title
Sponsor
Name of the Sponsor
Boston Scientific Corporation

4. Oversight

Data Monitoring Committee
No

5. Study Description

Brief Summary
NG PROMUS: A Prospective, Multicenter Trial to Assess the NG PROMUS Everolimus-Eluting Platinum Chromium Coronary Stent System (NG PROMUS Stent System) for the Treatment of Atherosclerotic Lesion(s)
Detailed Description
To evaluate clinical and peri-procedural angiographic and intravascular ultrasound (IVUS) outcomes for the NG PROMUS Everolimus-Eluting Platinum Chromium Coronary Stent System (NG PROMUS Stent System) in the treatment of subjects with atherosclerotic lesion(s) ≤ 34 mm in length (by visual estimate) in native coronary arteries ≥ 2.50 mm to ≤ 4.0 mm in diameter (by visual estimate)

6. Conditions and Keywords

Primary Disease or Condition Being Studied in the Trial, or the Focus of the Study
Atherosclerosis, Coronary Artery Disease
Keywords
drug eluting coronary stent

7. Study Design

Primary Purpose
Treatment
Study Phase
Not Applicable
Interventional Study Model
Single Group Assignment
Masking
None (Open Label)
Allocation
N/A
Enrollment
100 (Actual)

8. Arms, Groups, and Interventions

Arm Title
NG PROMUS stent
Arm Type
Experimental
Arm Description
Single-arm treatment group receiving interventional NG PROMUS study stent
Intervention Type
Device
Intervention Name(s)
Percutaneous coronary intervention (NG PROMUS)
Intervention Description
Interventional coronary artery stenting with NG PROMUS study stent.
Primary Outcome Measure Information:
Title
Technical Success Rate
Description
Technical success is defined as successful delivery and deployment of the study stent to the target lesion, without balloon rupture or stent embolization, and post-procedure diameter stenosis of <30% assessed in 2 near-orthogonal projections with TIMI 3 flow in the target lesion, as visually assessed by the physician
Time Frame
Participants will be followed for the duration of hospital stay, an expected average of 1 day
Secondary Outcome Measure Information:
Title
Target Lesion Revascularization (TLR) Rate
Description
Target lesion revascularization is any ischemia-driven repeat percutaneous intervention, to improve blood flow, of the successfully treated target lesion or bypass surgery of the target vessel with a graft distally to the successfully treated target lesion. A TLR will be considered as ischemia-driven if the target lesion diameter stenosis is >/= 50% by QCA and there is presence of clinical or functional ischemia which cannot be explained by other coronary or graft lesions. Clinical or functional ischemia is any of the following: The subject has a positive functional study corresponding to the area served by the target lesion. The subject has ischemic ECG changes at rest in a distribution consistent with the target vessel. The subject has ischemic symptoms referable to the target lesion. A TLR will be considered as ischemia-driven if the lesion diameter stenosis is >/= 70% by QCA even in the absence of clinical or functional ischemia.
Time Frame
Participants will be followed for the duration of hospital stay, an expected average of 1 day and at 30 days
Title
Target Lesion Failure (TLF) Rate
Description
Target lesion failure is any ischemia-driven revascularization of the target lesion, MI (Q-wave and non-Q-wave) related to the target vessel, or (cardiac) death. For the purposes of this protocol, if it cannot be determined with certainty whether the MI was related to the target vessel, it will be considered a TLF. The MI definition used for Target Lesion Failure was the PLATINUM MI definition.
Time Frame
Participants will be followed for the duration of hospital stay, an expected average of 1 day and at 30 days
Title
Target Vessel Revascularization (TVR) Rate
Description
Target vessel revascularization is defined as a TLR or a TVR remote. Target vessel revascularization remote is any ischemia-driven repeat percutaneous intervention, to improve blood flow, or bypass surgery of not previously existing lesions diameter stenosis >/= 50% by QCA in the target vessel, excluding the target lesion. A TVR will be considered ischemia-driven if the target vessel diameter stenosis is >/= 50% by QCA and any of the following are present: The subject has a positive functional study corresponding to the area served by the target vessel. The subject has ischemic ECG changes at rest in a distribution consistent with the target vessel. The subject has ischemic symptoms referable to the target vessel. A TVR will also be considered as ischemia-driven if the lesion diameter stenosis is >/=70% even in the absence of clinical or functional ischemia.
Time Frame
Participants will be followed for the duration of hospital stay, an expected average of 1 day and at 30 days
Title
Target Vessel Failure (TVF) Rate
Description
Target vessel failure is any ischemia-driven revascularization of the target vessel, MI (Q-wave and non-Q-wave) related to the target vessel or death related to the target vessel. For the purposes of this protocol, if it cannot be determined with certainty whether the MI or death was related to the target vessel, it will be considered a TVF. The MI definition used was the PLATINUM MI definition.
Time Frame
Participants will be followed for the duration of hospital stay, an expected average of 1 day and at 30 days
Title
Myocardial Infarction (MI, Q-wave and Non-Q-wave) Rate
Description
MI will be defined according to the PLATINUM Definition of MI with evidence pre-specified for i) Spontaneous, ii) PCI-related, iii) CABG related, and iv) autopsy evidence criteria.
Time Frame
Participants will be followed for the duration of hospital stay, an expected average of 1 day and at 30 days
Title
Cardiac Death Rate
Description
Cardiac death is defined as death due to any of the following. Acute MI Cardiac perforation/pericardial tamponade Arrhythmia or conduction abnormality CVA through hospital discharge or CVA suspected of being related to the procedure Death due to complication of the procedure, including bleeding, vascular repair, transfusion reaction, or bypass surgery Any death in which a cardiac cause cannot be excluded
Time Frame
Participants will be followed for the duration of hospital stay, an expected average of 1 day and at 30 days
Title
Non-cardiac Death Rate
Description
Non-cardiac death is defined as a death not due to any of the following: Acute MI Cardiac perforation/pericardial tamponade Arrhythmia or conduction abnormality CVA through hospital discharge or CVA suspected of being related to the procedure Death due to complication of the procedure, including bleeding, vascular repair, transfusion reaction, or bypass surgery Any death in which a cardiac cause cannot be excluded
Time Frame
Participants will be followed for the duration of hospital stay, an expected average of 1 day and at 30 days
Title
All Death Rate
Description
Death is categorized as cardiac or non-cardiac deaths.
Time Frame
Participants will be followed for the duration of hospital stay, an expected average of 1 day and at 30 days
Title
Cardiac Death or MI Rate
Description
Any cardiac death or MI event meeting the criteria defined for a cardiac death or MI. MI definition used was the PLATINUM definition for MI.
Time Frame
Participants will be followed for the duration of hospital stay, an expected average of 1 day and at 30 days
Title
All Death or MI Rate
Description
Any all-cause mortality event or MI meeting the criteria defined for any death or MI. MI definition used was the PLATINUM definition for MI.
Time Frame
Participants will be followed for the duration of hospital stay, an expected average of 1 day and at 30 days
Title
All Death/MI/TVR Rate
Description
Any event meeting the pre-specified criteria for any death, MI, or TVR. MI definition used was the PLATINUM definition for MI.
Time Frame
Participants will be followed for the duration of hospital stay, an expected average of 1 day and at 30 days
Title
Stent Thrombosis Rate (by Academic Research Consortium [ARC] Definitions)
Description
Stent thrombosis should be reported as a cumulative value at the different time points and with the different separate time points. Time 0 is defined as the time point after the guide catheter has been removed and the patient left the catheterization lab. Timing: Acute stent thrombosis*: 0 24 hours after stent implantation Subacute stent thrombosis*: >24 hours to 30 days after stent implantation Late stent thrombosis: >30 days to 1 year after stent implantation Very late stent thrombosis: >1 year after stent implantation * Acute/subacute can also be replaced by early stent thrombosis. Early stent thrombosis is 0 30 days. Stent thrombosis may be defined as: Confirmed/definite Probable Possible Confirmed/Definite (is considered either angiographic confirmed or pathologic confirmed)
Time Frame
Participants will be followed for the duration of hospital stay, an expected average of 1 day and at 30 days
Title
Clinical Procedural Success Rate
Description
Clinical procedural success is post-procedure diameter stenosis <30% in 2 near-orthogonal projections with TIMI 3 flow in all target lesions, as visually assessed by the physician, without the occurrence of in-hospital MI, TVR, or cardiac death. MI definition used was the PLATINUM definition for MI.
Time Frame
Participants will be followed for the duration of hospital stay, an expected average of 1 day
Title
In-stent Percent Diameter Stenosis (%DS)
Description
As measured by an independent angiographic core laboratory using quantitative coronary angiography (QCA), the % diameter stenosis of the in-stent region. Percent diameter stenosis: Relative changes that occur in the percent diameter stenosis are provided by the following relationship: % diameter stenosis= (1-[Minimum Lumen Diameter/Reference diameter]) x 100.
Time Frame
Participants will be followed for the duration of hospital stay, an expected average of 1 day
Title
In-segment Percent Diameter Stenosis (%DS)
Description
As measured by an independent angiographic core laboratory using quantitative coronary angiography (QCA), the % diameter stenosis of the in-segment region (in-segment includes the stented region and 5 mm edge regions). Percent diameter stenosis: Relative changes that occur in the percent diameter stenosis are provided by the following relationship: % diameter stenosis= (1-[Minimum Lumen Diameter/Reference diameter]) x 100.
Time Frame
Participants will be followed for the duration of hospital stay, an expected average of 1 day
Title
In-stent Minimum Lumen Diameter (MLD)
Description
As measured by an independent angiographic core laboratory using quantitative coronary angiography (QCA); the minimum lumen diameter (MLD) measured at the in-stent region. The MLD is the mean minimum lumen diameter (mm) from 2 orthogonal views.
Time Frame
Participants will be followed for the duration of hospital stay, an expected average of 1 day
Title
In-segment Minimum Lumen Diameter (MLD)
Description
As measured by an independent angiographic core laboratory using quantitative coronary angiography (QCA); the minimum lumen diameter (MLD) measured at the in-segment region (in-segment includes the stented region and 5 mm edge regions). The MLD is the mean minimum lumen diameter (mm) from 2 orthogonal views.
Time Frame
Participants will be followed for the duration of hospital stay, an expected average of 1 day
Title
Acute Gain
Description
Acute gain, as measured by angiographic core lab
Time Frame
Participants will be followed for the duration of hospital stay, an expected average of 1 day
Title
Vessel Area
Description
As measured by IVUS, the mean vessel area (mm2).
Time Frame
Participants will be followed for the duration of hospital stay, an expected average of 1 day
Title
Stent Area
Description
As measured by IVUS, the area of the stent.
Time Frame
Participants will be followed for the duration of hospital stay, an expected average of 1 day
Title
Lumen Area
Description
As measured by IVUS, the area of the lumen.
Time Frame
Participants will be followed for the duration of hospital stay, an expected average of 1 day
Title
Vessel Volume
Description
As measured by IVUS, the volume of the vessel.
Time Frame
Participants will be followed for the duration of hospital stay, an expected average of 1 day
Title
Stent Volume
Description
As measured by IVUS, the volume of the stent.
Time Frame
Participants will be followed for the duration of hospital stay, an expected average of 1 day
Title
Lumen Volume
Description
As measured by IVUS, the volume of the lumen.
Time Frame
Participants will be followed for the duration of hospital stay, an expected average of 1 day
Title
Incomplete Apposition
Description
Incomplete apposition rate, as measured by the IVUS core lab. Binary assessment of presence of one or more stent struts separated from the vessel wall as detected through intravascular ultrasound (IVUS).
Time Frame
Participants will be followed for the duration of hospital stay, an expected average of 1 day
Title
Percent Net Volume Obstruction
Description
The percentage of volume obstruction, as measured by the IVUS core lab.
Time Frame
Participants will be followed for the duration of hospital stay, an expected average of 1 day
Title
Longitudinal Stent Deformation
Description
Longitudinal stent deformation, evidenced by longitudinal compression or elongation, as the result of crossing a newly deployed stent with a second device, (such as a balloon catheter, stent system or IVUS catheter), causing the second device to become caught on the stent when the second device is advanced or retracted.
Time Frame
Participants will be followed for the duration of hospital stay, an expected average of 1 day

10. Eligibility

Sex
All
Minimum Age & Unit of Time
18 Years
Accepts Healthy Volunteers
No
Eligibility Criteria
Clinical Inclusion Criteria: Subject must be at least 18 years of age Subject (or legal guardian) understands the trial requirements and the treatment procedures and provides written informed consent before any trial-specific tests or procedures are performed Subject is eligible for percutaneous coronary intervention (PCI) Subject has symptomatic coronary artery disease with objective evidence of ischemia or silent ischemia Subject is an acceptable candidate for coronary artery bypass grafting (CABG) Subject is willing to comply with all protocol-required follow-up evaluation Angiographic Inclusion Criteria: Target lesion(s) must be located in a native coronary artery with a visually estimated reference vessel diameter (RVD) ≥2.50 mm and ≤4.0 mm Target lesion(s) length must be ≤34 mm (by visual estimate) Target lesion(s) must have visually estimated stenosis ≥50% and <100% with thrombolysis in Myocardial Infarction (TIMI) flow >1 and one of the following (stenosis ≥70%, abnormal fractional flow reserve (FFR), abnormal stress test or imaging stress test, or elevated biomarkers) prior to procedure Coronary anatomy is likely to allow delivery of a study device to the target lesions(s) The first lesion treated must be successfully pre-dilated/pretreated Note: Successful pre-dilatation/pretreatment refers to dilatation with a balloon catheter of appropriate length and diameter, or pretreatment with directional or rotational coronary atherectomy, laser or cutting/scoring balloon with no greater than 50% residual stenosis and no dissection greater than National Heart, Lung, Blood Institute (NHLBI) type C. Clinical Exclusion Criteria: Subject has clinical symptoms and/or electrocardiogram (ECG) changes consistent with acute ST elevation MI (STEMI) Subject has cardiogenic shock, hemodynamic instability requiring inotropic or mechanical circulatory support, intractable ventricular arrhythmias, or ongoing intractable angina Subject has received an organ transplant or is on a waiting list for an organ transplant Subject is receiving or scheduled to receive chemotherapy within 30 days before or after the index procedure Planned PCI (including staged procedures) or CABG after the index procedure Subject previously treated at any time with intravascular brachytherapy Subject has a known allergy to contrast (that cannot be adequately premedicated) and/or the trial stent system or protocol-required concomitant medications (e.g., platinum, platinum-chromium alloy, stainless steel, everolimus or structurally related compounds, polymer or individual components, all P2Y12 inhibitors, or aspirin) Subject has one of the following (as assessed prior to the index procedure):Other serious medical illness (e.g., cancer, congestive heart failure) with estimated life expectancy of less than 24 months; Current problems with substance abuse (e.g., alcohol, cocaine, heroin, etc.);Planned procedure that may cause non-compliance with the protocol or confound data interpretation Subject is receiving chronic (≥72 hours) anticoagulation therapy (i.e., heparin, coumadin) for indications other than acute coronary syndrome Subject has a platelet count <100,000 cells/mm3 or >700,000 cells/mm3 Subject has a white blood cell (WBC) count < 3,000 cells/mm3 Subject has documented or suspected liver disease, including laboratory evidence of hepatitis Subject is on dialysis or has baseline serum creatinine level >2.0 mg/dL (177µmol/L) Subject has a history of bleeding diathesis or coagulopathy or will refuse blood transfusions Subject has had a history of cerebrovascular accident (CVA) or transient ischemic attack (TIA) within the past 6 months Subject has an active peptic ulcer or active gastrointestinal (GI) bleeding Subject has signs or symptoms of active heart failure (i.e., NYHA class IV) at the time of the index procedure Subject is participating in another investigational drug or device clinical trial that has not reached its primary endpoint Subject intends to participate in another investigational drug or device clinical trial within 12 months after the index procedure Subject with known intention to procreate within 12 months after the index procedure (women of child-bearing potential who are sexually active must agree to use a reliable method of contraception from the time of screening through 12 months after the index procedure) Subject is a woman who is pregnant or nursing (a pregnancy test must be performed within 7 days prior to the index procedure in women of child-bearing potential) Angiographic Exclusion Criteria: Planned treatment of more than 3 lesions. Planned treatment of lesions in more than 2 major epicardial vessels Planned treatment of a single lesion with more than 1 stent Subject has 2 target lesions in the same vessel that are separated by less than 15 mm (by visual estimate) Target lesion(s) is located in the left main Target lesion(s) is located within 3 mm of the origin of the left anterior descending (LAD) coronary artery or left circumflex (LCx) coronary artery by visual estimate. Target lesion(s) is located within a saphenous vein graft or an arterial graft Target lesion(s) will be accessed via a saphenous vein graft or arterial graft Target lesion(s) with a TIMI flow 0 (total occlusion) or TIMI flow 1 prior to guide wire crossing Target lesion(s) treated during the index procedure that involves a complex bifurcation (e.g., bifurcation lesion requiring treatment with more than 1 stent) Target lesion(s) is restenotic from a previous stent implantation or study stent would overlap with a previous stent Subject has unprotected left main coronary artery disease (>50% diameter stenosis) Subject has been treated with any type of PCI (i.e., balloon angioplasty, stent, cutting balloon atherectomy) within 24 hours prior to the index procedure Thrombus, or possible thrombus, present in the target vessel (by visual estimate)
Overall Study Officials:
First Name & Middle Initial & Last Name & Degree
John A Ormiston, MBChB, FRACP, FRACR
Organizational Affiliation
Mercy Angiography Unit, Ltd. Mercy Hospital
Official's Role
Principal Investigator
Facility Information:
Facility Name
Fremantle Hospital
City
Fremantle
State/Province
Western Australia
ZIP/Postal Code
6160
Country
Australia
Facility Name
Mercy Angiography Unit, Ltd. Mercy Hospital
City
Auckland
ZIP/Postal Code
1003
Country
New Zealand
Facility Name
Auckland City Hospital
City
Auckland
ZIP/Postal Code
1010
Country
New Zealand
Facility Name
North Shore Hospital
City
Auckland
ZIP/Postal Code
1030
Country
New Zealand
Facility Name
Ascot Angiography
City
Auckland
ZIP/Postal Code
1546
Country
New Zealand
Facility Name
Christchurch
City
Christchurch
ZIP/Postal Code
8140
Country
New Zealand
Facility Name
Middlemore Hospital
City
Otahuhu
ZIP/Postal Code
1640
Country
New Zealand
Facility Name
National University Hospital Singapore
City
Singapore
ZIP/Postal Code
119228
Country
Singapore
Facility Name
National Heart Center Singapore
City
Singapore
ZIP/Postal Code
168752
Country
Singapore

12. IPD Sharing Statement

Links:
URL
http://www.pharma.us.novartis.com/info/products/name/zortress.jsp
Description
Drug-eluting product information from Manufacturer

Learn more about this trial