search
Back to results

A Study Comparing Two Stent on the Degree of Early Stent Healing and Late Lumen Loss.The OCT-ORION Study (OCT-ORION)

Primary Purpose

Coronary Artery Disease

Status
Completed
Phase
Phase 4
Locations
Hong Kong
Study Type
Interventional
Intervention
Resolute Integrity Stent
Biomatrix stent
Sponsored by
The University of Hong Kong
About
Eligibility
Locations
Arms
Outcomes
Full info

About this trial

This is an interventional treatment trial for Coronary Artery Disease focused on measuring Stent, OCT

Eligibility Criteria

18 Years - 85 Years (Adult, Older Adult)All SexesDoes not accept healthy volunteers

Inclusion Criteria:

  • Patient aged 18-85 years old
  • Patient with symptomatic coronary artery diseases involving two or more vessels requiring percutaneous coronary intervention

Exclusion Criteria:

  • Patient who is unable to give consent
  • Patient in acute myocardial infarction or unstable angina
  • Patient who is hemodynamically unstable
  • Patient who is allergic to contrast agents
  • Patient who is allergic to anti-platelet agents
  • Patient who is allergic to zotarolimus
  • Patient who is allergic to biolimus
  • Patient who is pregnant
  • Patient who has planned surgery in the following 12 months after percutaneous coronary intervention
  • Left main coronary lesion
  • Bifurcation lesion
  • Chronic total occlusion lesion
  • Coronary vessel size smaller than 2.5mm
  • Coronary lesion longer than 38mm in length

Sites / Locations

  • Division of Cardiology, Department of Medicine, QMH

Arms of the Study

Arm 1

Arm 2

Arm Type

Active Comparator

Active Comparator

Arm Label

Medtronic Resolute Integrity Stent

Biomatrix stent

Arm Description

Medtronic Resolute Integrity Stent

Biomatrix stent

Outcomes

Primary Outcome Measures

• OCT derived percentage stent strut coverage at 9 month
OCT derived percentage stent strut coverage at 9 month

Secondary Outcome Measures

Angiographic binary stenosis
• Angiographic binary stenosis at 9 month
• OCT derived neo-intimal area at 9 month
• OCT derived neo-intimal area at 9 month
• Minimal lumen diameter by Quantitative Coronary Analysis (QCA) at 9 month
• Minimal lumen diameter by Quantitative Coronary Analysis (QCA) at 9 month
• All major adverse cardiac events (all cardiac deaths, myocardial infarction, target vessel failure and target lesion revascularization, and stent thrombosis) at the pre-defined 2 to 9 months angiographic and OCT follow-up.
• All major adverse cardiac events (all cardiac deaths, myocardial infarction, target vessel failure and target lesion revascularization, and stent thrombosis) at the pre-defined 2 to 9 months angiographic and OCT follow-up.
• Target vessel stent thrombosis per Academic Research Consortium (ARC) definition
• Target vessel stent thrombosis per Academic Research Consortium (ARC) definition
Percentage of stent strut malapposition
Percentage of stent strut malapposition
Mean neo-intimal thickness (NIT) at 9 month
Mean neo-intimal thickness (NIT) at 9 month
Stent volume
Stent volume
Lumen volume
Lumen volume
Neointimal Hyperplasia (NIH) volume
Neointimal Hyperplasia (NIH) volume

Full Information

First Posted
March 22, 2012
Last Updated
July 24, 2017
Sponsor
The University of Hong Kong
search

1. Study Identification

Unique Protocol Identification Number
NCT01742507
Brief Title
A Study Comparing Two Stent on the Degree of Early Stent Healing and Late Lumen Loss.The OCT-ORION Study
Acronym
OCT-ORION
Official Title
A Randomized Optical Coherence Tomography Study Comparing Resolute Integrity to Biomatrix Drug-eluting Stent on the Degree of Early Stent Healing and Late Lumen Loss.The OCT-ORION Study
Study Type
Interventional

2. Study Status

Record Verification Date
July 2017
Overall Recruitment Status
Completed
Study Start Date
April 2012 (undefined)
Primary Completion Date
August 2016 (Actual)
Study Completion Date
August 2016 (Actual)

3. Sponsor/Collaborators

Responsible Party, by Official Title
Principal Investigator
Name of the Sponsor
The University of Hong Kong

4. Oversight

Data Monitoring Committee
Yes

5. Study Description

Brief Summary
Stent coverage and neo-intimal growth can be evaluated in-detail by intracoronary optical coherence tomography (OCT), which is a catheter-based imaging technique. It is performed as part of the PCI procedure. OCT is the optical analogue of intravascular ultrasound (IVUS), except that it can provide much higher resolution of coronary cross sectional images than IVUS. The LightLab C7XR OCT system (Frequency Domain OCT) used in this Hospital has obtained full CE Mark, approved by the US FDA, and approved for clinical use in Hong Kong. It has been shown to be safe in clinical settings and has been used in over 300 patients without complication at Queen Mary Hospital. In this study, stent coverage and neo-intimal growth between zotarolimus-eluting stents (ZES) and biolimus-eluting stents (BES) will be compared by using OCT at 9 month and specific post-intervention re-study intervals. The investigators objective is to investigate the clinical impact and OCT difference on early stent healing and late lumen loss between the two new-generation limus-eluting-stents - Resolute Integrity and Biomatrix, which differ in stent design, eluting drug and coating polymer.
Detailed Description
This is a prospective, randomised, assessor-blinded, single centre study. Patients with symptomatic coronary artery diseases in 2 or 3 coronary vessels requiring PCI are eligible for the study. PCI will be performed in the usual manner to all the study lesions in the same procedure. In a randomized fashion, each patient will have one artery with critical disease(s) treated by the Resolute Integrity Stent(s) and the other artery treated by the Biomatrix Stent(s). Baseline OCT data will be obtained right after stenting. The remaining coronary artery, if diseased and required PCI treatment, will be treated during the angiographic and OCT follow-up as a staged procedure. Patients will be randomly assigned into 5 groups with equal number, receiving a follow-up coronary angiogram with OCT from 2, 3, 4, 5 and 6 months interval post-intervention. Each patient will serve as his/her own control comparing the 2 types of stents. At 9-month post-intervention, all patients will receive a second follow-up coronary angiogram with OCT. All OCT data analyses will be performed in a blinded fashion by a core laboratory. Phone follow up will be carried out for cardiac events at 1 year and 2 year of post intervention.

6. Conditions and Keywords

Primary Disease or Condition Being Studied in the Trial, or the Focus of the Study
Coronary Artery Disease
Keywords
Stent, OCT

7. Study Design

Primary Purpose
Treatment
Study Phase
Phase 4
Interventional Study Model
Single Group Assignment
Masking
None (Open Label)
Allocation
Randomized
Enrollment
60 (Actual)

8. Arms, Groups, and Interventions

Arm Title
Medtronic Resolute Integrity Stent
Arm Type
Active Comparator
Arm Description
Medtronic Resolute Integrity Stent
Arm Title
Biomatrix stent
Arm Type
Active Comparator
Arm Description
Biomatrix stent
Intervention Type
Device
Intervention Name(s)
Resolute Integrity Stent
Intervention Description
Resolute Integrity Stent
Intervention Type
Device
Intervention Name(s)
Biomatrix stent
Intervention Description
Biomatrix stent
Primary Outcome Measure Information:
Title
• OCT derived percentage stent strut coverage at 9 month
Description
OCT derived percentage stent strut coverage at 9 month
Time Frame
9 month
Secondary Outcome Measure Information:
Title
Angiographic binary stenosis
Description
• Angiographic binary stenosis at 9 month
Time Frame
9 month
Title
• OCT derived neo-intimal area at 9 month
Description
• OCT derived neo-intimal area at 9 month
Time Frame
at 9 month
Title
• Minimal lumen diameter by Quantitative Coronary Analysis (QCA) at 9 month
Description
• Minimal lumen diameter by Quantitative Coronary Analysis (QCA) at 9 month
Time Frame
9 month
Title
• All major adverse cardiac events (all cardiac deaths, myocardial infarction, target vessel failure and target lesion revascularization, and stent thrombosis) at the pre-defined 2 to 9 months angiographic and OCT follow-up.
Description
• All major adverse cardiac events (all cardiac deaths, myocardial infarction, target vessel failure and target lesion revascularization, and stent thrombosis) at the pre-defined 2 to 9 months angiographic and OCT follow-up.
Time Frame
2 to 9 months
Title
• Target vessel stent thrombosis per Academic Research Consortium (ARC) definition
Description
• Target vessel stent thrombosis per Academic Research Consortium (ARC) definition
Time Frame
from enrollment till 2 years follow up
Title
Percentage of stent strut malapposition
Description
Percentage of stent strut malapposition
Time Frame
9 month
Title
Mean neo-intimal thickness (NIT) at 9 month
Description
Mean neo-intimal thickness (NIT) at 9 month
Time Frame
9 month
Title
Stent volume
Description
Stent volume
Time Frame
at 9 month
Title
Lumen volume
Description
Lumen volume
Time Frame
at 9 month
Title
Neointimal Hyperplasia (NIH) volume
Description
Neointimal Hyperplasia (NIH) volume
Time Frame
at 9 month

10. Eligibility

Sex
All
Minimum Age & Unit of Time
18 Years
Maximum Age & Unit of Time
85 Years
Accepts Healthy Volunteers
No
Eligibility Criteria
Inclusion Criteria: Patient aged 18-85 years old Patient with symptomatic coronary artery diseases involving two or more vessels requiring percutaneous coronary intervention Exclusion Criteria: Patient who is unable to give consent Patient in acute myocardial infarction or unstable angina Patient who is hemodynamically unstable Patient who is allergic to contrast agents Patient who is allergic to anti-platelet agents Patient who is allergic to zotarolimus Patient who is allergic to biolimus Patient who is pregnant Patient who has planned surgery in the following 12 months after percutaneous coronary intervention Left main coronary lesion Bifurcation lesion Chronic total occlusion lesion Coronary vessel size smaller than 2.5mm Coronary lesion longer than 38mm in length
Overall Study Officials:
First Name & Middle Initial & Last Name & Degree
Stephen Wai Luen LEE, MD FRCP FACC
Organizational Affiliation
Queen Mary Hosptial, The Univeristy of Hong Kong
Official's Role
Principal Investigator
Facility Information:
Facility Name
Division of Cardiology, Department of Medicine, QMH
City
Hong Kong
Country
Hong Kong

12. IPD Sharing Statement

Plan to Share IPD
Undecided
Citations:
PubMed Identifier
12050336
Citation
Morice MC, Serruys PW, Sousa JE, Fajadet J, Ban Hayashi E, Perin M, Colombo A, Schuler G, Barragan P, Guagliumi G, Molnar F, Falotico R; RAVEL Study Group. Randomized Study with the Sirolimus-Coated Bx Velocity Balloon-Expandable Stent in the Treatment of Patients with de Novo Native Coronary Artery Lesions. A randomized comparison of a sirolimus-eluting stent with a standard stent for coronary revascularization. N Engl J Med. 2002 Jun 6;346(23):1773-80. doi: 10.1056/NEJMoa012843.
Results Reference
result
PubMed Identifier
14523139
Citation
Moses JW, Leon MB, Popma JJ, Fitzgerald PJ, Holmes DR, O'Shaughnessy C, Caputo RP, Kereiakes DJ, Williams DO, Teirstein PS, Jaeger JL, Kuntz RE; SIRIUS Investigators. Sirolimus-eluting stents versus standard stents in patients with stenosis in a native coronary artery. N Engl J Med. 2003 Oct 2;349(14):1315-23. doi: 10.1056/NEJMoa035071.
Results Reference
result
PubMed Identifier
14724301
Citation
Stone GW, Ellis SG, Cox DA, Hermiller J, O'Shaughnessy C, Mann JT, Turco M, Caputo R, Bergin P, Greenberg J, Popma JJ, Russell ME; TAXUS-IV Investigators. A polymer-based, paclitaxel-eluting stent in patients with coronary artery disease. N Engl J Med. 2004 Jan 15;350(3):221-31. doi: 10.1056/NEJMoa032441.
Results Reference
result
PubMed Identifier
17296823
Citation
Kastrati A, Mehilli J, Pache J, Kaiser C, Valgimigli M, Kelbaek H, Menichelli M, Sabate M, Suttorp MJ, Baumgart D, Seyfarth M, Pfisterer ME, Schomig A. Analysis of 14 trials comparing sirolimus-eluting stents with bare-metal stents. N Engl J Med. 2007 Mar 8;356(10):1030-9. doi: 10.1056/NEJMoa067484. Epub 2007 Feb 12.
Results Reference
result
PubMed Identifier
17296824
Citation
Stone GW, Moses JW, Ellis SG, Schofer J, Dawkins KD, Morice MC, Colombo A, Schampaert E, Grube E, Kirtane AJ, Cutlip DE, Fahy M, Pocock SJ, Mehran R, Leon MB. Safety and efficacy of sirolimus- and paclitaxel-eluting coronary stents. N Engl J Med. 2007 Mar 8;356(10):998-1008. doi: 10.1056/NEJMoa067193. Epub 2007 Feb 12.
Results Reference
result
PubMed Identifier
17145250
Citation
Bavry AA, Kumbhani DJ, Helton TJ, Borek PP, Mood GR, Bhatt DL. Late thrombosis of drug-eluting stents: a meta-analysis of randomized clinical trials. Am J Med. 2006 Dec;119(12):1056-61. doi: 10.1016/j.amjmed.2006.01.023.
Results Reference
result
PubMed Identifier
17135281
Citation
Matsumoto D, Shite J, Shinke T, Otake H, Tanino Y, Ogasawara D, Sawada T, Paredes OL, Hirata K, Yokoyama M. Neointimal coverage of sirolimus-eluting stents at 6-month follow-up: evaluated by optical coherence tomography. Eur Heart J. 2007 Apr;28(8):961-7. doi: 10.1093/eurheartj/ehl413. Epub 2006 Nov 29.
Results Reference
result
PubMed Identifier
19709765
Citation
Kim JS, Fan C, Choi D, Jang IK, Lee JM, Kim TH, Park SM, Paik SI, Ko YG, Hong MK, Jang Y, Chung N. Different patterns of neointimal coverage between acute coronary syndrome and stable angina after various types of drug-eluting stents implantation; 9-month follow-up optical coherence tomography study. Int J Cardiol. 2011 Feb 3;146(3):341-6. doi: 10.1016/j.ijcard.2009.07.012. Epub 2009 Aug 25.
Results Reference
result
PubMed Identifier
19889649
Citation
Barlis P, Regar E, Serruys PW, Dimopoulos K, van der Giessen WJ, van Geuns RJ, Ferrante G, Wandel S, Windecker S, van Es GA, Eerdmans P, Juni P, di Mario C. An optical coherence tomography study of a biodegradable vs. durable polymer-coated limus-eluting stent: a LEADERS trial sub-study. Eur Heart J. 2010 Jan;31(2):165-76. doi: 10.1093/eurheartj/ehp480. Epub 2009 Nov 4.
Results Reference
result
PubMed Identifier
19737697
Citation
Udipi K, Melder RJ, Chen M, Cheng P, Hezi-Yamit A, Sullivan C, Wong J, Wilcox J. The next generation Endeavor Resolute Stent: role of the BioLinx Polymer System. EuroIntervention. 2007 May;3(1):137-9. No abstract available.
Results Reference
result
PubMed Identifier
20554978
Citation
Serruys PW, Silber S, Garg S, van Geuns RJ, Richardt G, Buszman PE, Kelbaek H, van Boven AJ, Hofma SH, Linke A, Klauss V, Wijns W, Macaya C, Garot P, DiMario C, Manoharan G, Kornowski R, Ischinger T, Bartorelli A, Ronden J, Bressers M, Gobbens P, Negoita M, van Leeuwen F, Windecker S. Comparison of zotarolimus-eluting and everolimus-eluting coronary stents. N Engl J Med. 2010 Jul 8;363(2):136-46. doi: 10.1056/NEJMoa1004130. Epub 2010 Jun 16.
Results Reference
result
PubMed Identifier
21459430
Citation
Silber S, Windecker S, Vranckx P, Serruys PW; RESOLUTE All Comers investigators. Unrestricted randomised use of two new generation drug-eluting coronary stents: 2-year patient-related versus stent-related outcomes from the RESOLUTE All Comers trial. Lancet. 2011 Apr 9;377(9773):1241-7. doi: 10.1016/S0140-6736(11)60395-4. Epub 2011 Apr 1.
Results Reference
result
PubMed Identifier
17280537
Citation
Grube E, Buellesfeld L. BioMatrix Biolimus A9-eluting coronary stent: a next-generation drug-eluting stent for coronary artery disease. Expert Rev Med Devices. 2006 Nov;3(6):731-41. doi: 10.1586/17434440.3.6.731.
Results Reference
result
PubMed Identifier
19758877
Citation
Grube E, Hauptmann KE, Buellesfeld L, Lim V, Abizaid A. Six-month results of a randomized study to evaluate safety and efficacy of a Biolimus A9 eluting stent with a biodegradable polymer coating. EuroIntervention. 2005 May;1(1):53-7.
Results Reference
result
PubMed Identifier
18765162
Citation
Windecker S, Serruys PW, Wandel S, Buszman P, Trznadel S, Linke A, Lenk K, Ischinger T, Klauss V, Eberli F, Corti R, Wijns W, Morice MC, di Mario C, Davies S, van Geuns RJ, Eerdmans P, van Es GA, Meier B, Juni P. Biolimus-eluting stent with biodegradable polymer versus sirolimus-eluting stent with durable polymer for coronary revascularisation (LEADERS): a randomised non-inferiority trial. Lancet. 2008 Sep 27;372(9644):1163-73. doi: 10.1016/S0140-6736(08)61244-1. Epub 2008 Aug 31.
Results Reference
result
PubMed Identifier
18307999
Citation
Yamaguchi T, Terashima M, Akasaka T, Hayashi T, Mizuno K, Muramatsu T, Nakamura M, Nakamura S, Saito S, Takano M, Takayama T, Yoshikawa J, Suzuki T. Safety and feasibility of an intravascular optical coherence tomography image wire system in the clinical setting. Am J Cardiol. 2008 Mar 1;101(5):562-7. doi: 10.1016/j.amjcard.2007.09.116. Epub 2008 Jan 10.
Results Reference
result
PubMed Identifier
19737719
Citation
Prati F, Cera M, Ramazzotti V, Imola F, Giudice R, Albertucci M. Safety and feasibility of a new non-occlusive technique for facilitated intracoronary optical coherence tomography (OCT) acquisition in various clinical and anatomical scenarios. EuroIntervention. 2007 Nov;3(3):365-70. doi: 10.4244/eijv3i3a66.
Results Reference
result
PubMed Identifier
29654119
Citation
Lee SWL, Tam FCC, Lam SCC, Kong SL, Shea CP, Chan KKW, Wong MKL, Chan MPH, Wong AYT, Yung ASY, Lam YM, Zhang LW, Wu KKY, Mintz GS, Maehara A. The OCT-ORION Study: A Randomized Optical Coherence Tomography Study Comparing Resolute Integrity to Biomatrix Drug-Eluting Stent on the Degree of Early Stent Healing and Late Lumen Loss. Circ Cardiovasc Interv. 2018 Apr;11(4):e006034. doi: 10.1161/CIRCINTERVENTIONS.117.006034.
Results Reference
derived

Learn more about this trial

A Study Comparing Two Stent on the Degree of Early Stent Healing and Late Lumen Loss.The OCT-ORION Study

We'll reach out to this number within 24 hrs