Assessment of Safety and Tolerability of Chitosan-N-acetylcysteine Eye Drops in Subjects While Wearing Contact Lenses and Before Insertion of Contact Lenses
Primary Purpose
Dry Eye Syndrome
Status
Completed
Phase
Phase 1
Locations
Austria
Study Type
Interventional
Intervention
Chitosan-N-acetylcysteine eye drops (concentration of 0.1%)
Physiological saline solution
Sponsored by
About this trial
This is an interventional treatment trial for Dry Eye Syndrome focused on measuring Chitosan-N-Acetylcysteine, contact lenses, safety and tolerability
Eligibility Criteria
Inclusion Criteria:
- Regular contact lens wear since 3 years minimum
- Daily wearing time of the contact lens of 8 hours or more
- Good tolerability of the contact lenses without ocular discomfort or local signs of chemosis, conjunctival redness or other signs of intolerability as judged by the investigator.
- Subject willing to continue contact lens use for the study period
- Normal laboratory values unless the investigator considers an abnormality to be clinically irrelevant
- Normal findings in the medical history and physical examination unless the investigator considers an abnormality to be clinically irrelevant
- Normal ophthalmic findings except ametropia
Exclusion Criteria:
- Participation in a clinical trial in the 3 weeks preceding the study
- Use of colored contact lenses
- Abuse of alcoholic beverages or other drugs
- Symptoms of a clinically relevant illness in the 3 weeks before the first study day
- Pregnancy
Sites / Locations
- Department of Clinical Pharmacology, Medical University of Vienna
Arms of the Study
Arm 1
Arm 2
Arm 3
Arm 4
Arm Type
Experimental
Experimental
Experimental
Experimental
Arm Label
12 subjects wearing soft contact lenses
12 subjects wearing rigid contact lenses
12 subjects with soft contact lenses
12 subjects with rigid contact lenses
Arm Description
The medical test device will be administered with the contact lenses inserted
The medical test device will be administered with the contact lenses inserted
The medical test device will be administered before insertion of the contact lenses
The medical test device will be administered before insertion of the contact lenses
Outcomes
Primary Outcome Measures
Descriptive evaluation of ocular discomfort as assessed by the subjects
Secondary Outcome Measures
Number of subjects with significant increase of redness
Number of subjects experiencing adverse reactions
Full Information
NCT ID
NCT01747616
First Posted
December 7, 2012
Last Updated
December 10, 2012
Sponsor
Medical University of Vienna
Collaborators
Croma-Pharma GmbH
1. Study Identification
Unique Protocol Identification Number
NCT01747616
Brief Title
Assessment of Safety and Tolerability of Chitosan-N-acetylcysteine Eye Drops in Subjects While Wearing Contact Lenses and Before Insertion of Contact Lenses
Official Title
Assessment of Safety and Tolerability of Chitosan-N-acetylcysteine Eye Drops in Subjects While Wearing Contact Lenses and Before Insertion of Contact Lenses
Study Type
Interventional
2. Study Status
Record Verification Date
December 2012
Overall Recruitment Status
Completed
Study Start Date
July 2011 (undefined)
Primary Completion Date
November 2011 (Actual)
Study Completion Date
December 2012 (Actual)
3. Sponsor/Collaborators
Responsible Party, by Official Title
Principal Investigator
Name of the Sponsor
Medical University of Vienna
Collaborators
Croma-Pharma GmbH
4. Oversight
Data Monitoring Committee
Yes
5. Study Description
Brief Summary
The "dry eye syndrome" DES is a highly prevalent ocular disease, in particular in the elderly population. One mainstay of therapy for patients suffering from DES is the use of topically administered lubricants. However, despite many efforts, no "ideal" formulation has yet been found.
Recently, Croma Pharma has introduced chitosan-N-acetylcysteine eye drops, designed for treatment of symptoms related to DES. Chemically, chitosan is a polycationic biopolymer with favourable biological properties such as high biocompatibility and low toxicity. Additionally, the new formulation comprises N-acetylcysteine, which has been used in ophthalmology because of its mucolytic properties for several years. Based on theoretical considerations, one can hypothesize that the new chitosan derivative may show an increased adhesion to mucins of the ocular surface and may therefore be particularly beneficial in reducing the symptoms associated with DES. We have recently shown in a phase I trial that single instillation of chitosan-N-acetylcysteine eye drops is well tolerated in young healthy subjects.
However, no data is yet available about safety and tolerability of chitosan-N-acetylcysteine in subjects wearing contact lenses. This is of special interest because the tear film is critical to successful contact lens wear. Disturbances of the quantity or quality of the tear film results in intolerance of contact lens wear and possible damage to the ocular surface. This trial seeks to investigate the local tolerability and possible ocular discomfort of chitosan-N-acetylcysteine eye drops after repeated instillation .
6. Conditions and Keywords
Primary Disease or Condition Being Studied in the Trial, or the Focus of the Study
Dry Eye Syndrome
Keywords
Chitosan-N-Acetylcysteine, contact lenses, safety and tolerability
7. Study Design
Primary Purpose
Treatment
Study Phase
Phase 1
Interventional Study Model
Parallel Assignment
Masking
ParticipantCare ProviderInvestigatorOutcomes Assessor
Allocation
Randomized
Enrollment
48 (Actual)
8. Arms, Groups, and Interventions
Arm Title
12 subjects wearing soft contact lenses
Arm Type
Experimental
Arm Description
The medical test device will be administered with the contact lenses inserted
Arm Title
12 subjects wearing rigid contact lenses
Arm Type
Experimental
Arm Description
The medical test device will be administered with the contact lenses inserted
Arm Title
12 subjects with soft contact lenses
Arm Type
Experimental
Arm Description
The medical test device will be administered before insertion of the contact lenses
Arm Title
12 subjects with rigid contact lenses
Arm Type
Experimental
Arm Description
The medical test device will be administered before insertion of the contact lenses
Intervention Type
Device
Intervention Name(s)
Chitosan-N-acetylcysteine eye drops (concentration of 0.1%)
Intervention Description
1 drop of the medical device in 1 randomly chosen eye
Intervention Type
Other
Intervention Name(s)
Physiological saline solution
Intervention Description
1 drop as placebo in the other eye not receiving the medical device
Primary Outcome Measure Information:
Title
Descriptive evaluation of ocular discomfort as assessed by the subjects
Time Frame
on 5 consecutive days before and after instillation of the eye drops
Secondary Outcome Measure Information:
Title
Number of subjects with significant increase of redness
Time Frame
on 5 consecutive study days
Title
Number of subjects experiencing adverse reactions
Time Frame
on 5 consecutive study days
10. Eligibility
Sex
All
Minimum Age & Unit of Time
18 Years
Accepts Healthy Volunteers
Accepts Healthy Volunteers
Eligibility Criteria
Inclusion Criteria:
Regular contact lens wear since 3 years minimum
Daily wearing time of the contact lens of 8 hours or more
Good tolerability of the contact lenses without ocular discomfort or local signs of chemosis, conjunctival redness or other signs of intolerability as judged by the investigator.
Subject willing to continue contact lens use for the study period
Normal laboratory values unless the investigator considers an abnormality to be clinically irrelevant
Normal findings in the medical history and physical examination unless the investigator considers an abnormality to be clinically irrelevant
Normal ophthalmic findings except ametropia
Exclusion Criteria:
Participation in a clinical trial in the 3 weeks preceding the study
Use of colored contact lenses
Abuse of alcoholic beverages or other drugs
Symptoms of a clinically relevant illness in the 3 weeks before the first study day
Pregnancy
Facility Information:
Facility Name
Department of Clinical Pharmacology, Medical University of Vienna
City
Vienna
ZIP/Postal Code
1090
Country
Austria
12. IPD Sharing Statement
Learn more about this trial
Assessment of Safety and Tolerability of Chitosan-N-acetylcysteine Eye Drops in Subjects While Wearing Contact Lenses and Before Insertion of Contact Lenses
We'll reach out to this number within 24 hrs