Comparison of the Tibiofemoral Rotational Alignment After Mobile and Fixed Bearing Total Knee Arthroplasty
Primary Purpose
Osteoarthritis
Status
Completed
Phase
Phase 4
Locations
Study Type
Interventional
Intervention
total knee arthroplasty
total knee arthroplasty
Sponsored by

About this trial
This is an interventional treatment trial for Osteoarthritis focused on measuring Arthroplasty, Replacement, Knee, Rotational Alignment
Eligibility Criteria
Inclusion Criteria:
- Primary osteoarthritis
Exclusion Criteria:
- infection
- inflammatory arthritis
- reoperation
- severe deformity
Sites / Locations
Arms of the Study
Arm 1
Arm 2
Arm Type
Experimental
Active Comparator
Arm Label
Mobile Bearing
Fixed Bearing
Arm Description
Mobile bearing total knee arthroplasty
Fixed Bearing total knee arthroplasty
Outcomes
Primary Outcome Measures
Tibial anteroposterior axis relative to femoral anteroposterior axis
Tibial anteroposterior axis relative to femoral anteroposterior axis on Computed tomogram images
Secondary Outcome Measures
Full Information
NCT ID
NCT01751334
First Posted
December 13, 2012
Last Updated
December 13, 2012
Sponsor
Seoul National University Hospital
1. Study Identification
Unique Protocol Identification Number
NCT01751334
Brief Title
Comparison of the Tibiofemoral Rotational Alignment After Mobile and Fixed Bearing Total Knee Arthroplasty
Official Title
Comparison of the Tibiofemoral Rotational Alignment After Mobile and Fixed Bearing Total Knee Arthroplasty
Study Type
Interventional
2. Study Status
Record Verification Date
December 2012
Overall Recruitment Status
Completed
Study Start Date
September 2005 (undefined)
Primary Completion Date
August 2006 (Actual)
Study Completion Date
August 2011 (Actual)
3. Sponsor/Collaborators
Responsible Party, by Official Title
Sponsor
Name of the Sponsor
Seoul National University Hospital
4. Oversight
Data Monitoring Committee
No
5. Study Description
Brief Summary
The anatomic landmark for the anteroposterior (AP) axis of the proximal tibia and its variability was investigated in this study in order to determine whether a certain landmark could be employed as a reference axis for the proximal tibia after rotating platform mobile bearing (RP-MB) and fixed bearing (FB) total knee arthroplasties (TKAs).
Detailed Description
Reference of tibial AP axis for implanting tibial component in total knee arthroplasty have not been concluded. This study can suggest appropriate method for alingning the tibial component to accurate tibial AP axis.
6. Conditions and Keywords
Primary Disease or Condition Being Studied in the Trial, or the Focus of the Study
Osteoarthritis
Keywords
Arthroplasty, Replacement, Knee, Rotational Alignment
7. Study Design
Primary Purpose
Treatment
Study Phase
Phase 4
Interventional Study Model
Parallel Assignment
Masking
None (Open Label)
Allocation
Randomized
Enrollment
80 (Actual)
8. Arms, Groups, and Interventions
Arm Title
Mobile Bearing
Arm Type
Experimental
Arm Description
Mobile bearing total knee arthroplasty
Arm Title
Fixed Bearing
Arm Type
Active Comparator
Arm Description
Fixed Bearing total knee arthroplasty
Intervention Type
Device
Intervention Name(s)
total knee arthroplasty
Other Intervention Name(s)
Sigma® RP-F Knee System, Depuy J&J, Warsaw, IN, USA
Intervention Description
Mobile Bearing Total knee Arthroplasty
Intervention Type
Device
Intervention Name(s)
total knee arthroplasty
Other Intervention Name(s)
Nexgen® Legacy® Knee LPS-Flex, Zimmer, Warsaw, IN, USA
Intervention Description
Fixed Total Knee Arthroplasty
Primary Outcome Measure Information:
Title
Tibial anteroposterior axis relative to femoral anteroposterior axis
Description
Tibial anteroposterior axis relative to femoral anteroposterior axis on Computed tomogram images
Time Frame
postoperative 2 weeks
10. Eligibility
Sex
All
Accepts Healthy Volunteers
No
Eligibility Criteria
Inclusion Criteria:
Primary osteoarthritis
Exclusion Criteria:
infection
inflammatory arthritis
reoperation
severe deformity
Overall Study Officials:
First Name & Middle Initial & Last Name & Degree
Sahnghoon Lee, M.D., Ph.D.
Official's Role
Principal Investigator
First Name & Middle Initial & Last Name & Degree
Myung Chul Lee, M.D., Ph.D.
Official's Role
Study Chair
12. IPD Sharing Statement
Learn more about this trial
Comparison of the Tibiofemoral Rotational Alignment After Mobile and Fixed Bearing Total Knee Arthroplasty