search
Back to results

Development of a PET-MR Myocardial Perfusion Examination Using Regadenoson (PET/MR-P)

Primary Purpose

Ischemic Heart Disease

Status
Completed
Phase
Phase 4
Locations
United States
Study Type
Interventional
Intervention
Regadenoson
Sponsored by
Washington University School of Medicine
About
Eligibility
Locations
Arms
Outcomes
Full info

About this trial

This is an interventional diagnostic trial for Ischemic Heart Disease focused on measuring PET MR myocardial perfusion imaging

Eligibility Criteria

18 Years - undefined (Adult, Older Adult)All SexesDoes not accept healthy volunteers

Inclusion Criteria:

  • Patients who have had a clinically ordered rest/regadenoson single-isotope SPECT-MPI study within 10 days prior to cardiac PET-MRI examination
  • Reversible perfusion abnormalities on SPECT imaging in at least 2 contiguous myocardial segments
  • Patients for whom standard of care coronary ICA is planned

Exclusion Criteria:

  • An clinical event (ie; worsening angina pectoris or myocardial infarction) occuring after the SPECT-MPI and before the cardiac MRI examination
  • Myocardial revascularization occuring after the SPECT-MPI and before the cardiac MRI examination
  • Contraindications to MR imaging (pacemaker, brain aneurysm clips, shrapnel, etc.)
  • Renal insufficiency (GFR < 60 mL/min/1.73m2)
  • Allergy or other contraindication to gadolinium-based MR contrast agent
  • Second or third degree atrioventricular (AV) block
  • Active asthma
  • Seizures
  • Current hypotension (<100/60)
  • Current hypertension (>160/90)
  • Pregnancy
  • Breast feeding
  • Use of caffeine, nicotine or over the counter cold medicines within 12 hours of the cardiac PET-MRI examination
  • Use of the medication dipyridamole within 48 hrs of the cardiac PET-MRI examination

Sites / Locations

  • Center for Clinical Imaging Research at Washington University School of Medicine

Arms of the Study

Arm 1

Arm Type

Experimental

Arm Label

Single group assignment - imaging

Arm Description

All patients will undergo PET-MR myocardial perfusion imaging during rapid intravenous administration of 0.4 mg regadenoson.

Outcomes

Primary Outcome Measures

Diagnostic Accuracy of Cardiac PET/MRI Examination
The accuracy of the cardiac PET and cardiac MR examination components of the PET/MRI, and the accuracy of the combined PET/MR examination, for ischemic heart disease will be compared to the accuracy of cardiac SPECT in patients who have had ICA as "truth" or the reference standard. To assess the accuracy of an abbreviated PET/MR examination, an additional accuracy analysis was made using only the stress PET perfusion imaging and the MR LGE data sets. The accuracy of this combined data set was also determined with ICA as "truth" or the reference standard. Accuracy is calculated as % difference = (experimental - true) x 100%.

Secondary Outcome Measures

Full Information

First Posted
January 23, 2013
Last Updated
May 15, 2018
Sponsor
Washington University School of Medicine
Collaborators
Astellas Pharma US, Inc.
search

1. Study Identification

Unique Protocol Identification Number
NCT01779869
Brief Title
Development of a PET-MR Myocardial Perfusion Examination Using Regadenoson
Acronym
PET/MR-P
Official Title
Development of a PET-MR Myocardial Perfusion Examination Using Regadenoson
Study Type
Interventional

2. Study Status

Record Verification Date
May 2018
Overall Recruitment Status
Completed
Study Start Date
January 2013 (undefined)
Primary Completion Date
June 2015 (Actual)
Study Completion Date
June 2015 (Actual)

3. Sponsor/Collaborators

Responsible Party, by Official Title
Principal Investigator
Name of the Sponsor
Washington University School of Medicine
Collaborators
Astellas Pharma US, Inc.

4. Oversight

Data Monitoring Committee
No

5. Study Description

Brief Summary
The objective for this pilot study is to develop an optimized, clinically usable myocardial PET-MR perfusion protocol and to determine which of all data potentially available should be acquired for a clinical myocardial perfusion examination. Hypothesis: The hypothesis is that high resolution, high sensitivity DCE MRI could replace the rest PET myocardial perfusion imaging, significantly decreasing examination time and patient radiation dose while maintaining the comprehensive reference-quality PET myocardial stress perfusion coverage. The primary outcome will be comparison of diagnostic accuracy of each combination of imaging to detect clinically significant coronary artery stenosis (≥70% diameter stenosis).
Detailed Description
Simultaneous acquisition PET-MRI is a new technology that has the potential to significantly impact diagnostic patient care. It combines high signal resolution MRI anatomic imaging and PET biological measurements, with the added benefit of radiation dose reduction in comparison to PET-CT. As the incidence of false positive SPECT-MPI studies secondary to attenuation artifact is relatively high and MRI coverage of the left ventricular myocardium is limited, it is likely that one of the immediate applications of PET-MRI technology is myocardial ischemia assessment. PET has long been considered the noninvasive reference standard for myocardial perfusion. However, delayed contrast enhanced (DCE) MRI is very sensitive for infarct detection. Indeed, both PET and MR imaging have the potential to provide comprehensive whole heart ischemia and infarct detection. PET-MR technology, with its ability to obtain simultaneous perfusion information via both PET and MRI, has the potential to obtain multiple, possibly redundant, data sets. On the other hand, it also has the potential to combine the best of both techniques to provide a highly robust examination that is both shorter and of lower radiation dose than the standard myocardial PET perfusion examination. Optimization of a protocol is necessary to develop a comprehensive protocol without redundancy. Because of its single injection capability, regadenoson is ideally suited to a protocol that will assess and employ dual-modality myocardial perfusion data collection. It is expected that the best candidates for PET-MR myocardial perfusion imaging will likely be a) patients whose body habitus suggests that their SPECT-MPI examination would be limited by attenuation artifact -- women with large breasts and patients (usually men) with abdominal obesity and/or b) patients who may have a smaller region of ischemia that might be missed on an MRI examinations with limited perfusion coverage.

6. Conditions and Keywords

Primary Disease or Condition Being Studied in the Trial, or the Focus of the Study
Ischemic Heart Disease
Keywords
PET MR myocardial perfusion imaging

7. Study Design

Primary Purpose
Diagnostic
Study Phase
Phase 4
Interventional Study Model
Single Group Assignment
Masking
None (Open Label)
Allocation
N/A
Enrollment
16 (Actual)

8. Arms, Groups, and Interventions

Arm Title
Single group assignment - imaging
Arm Type
Experimental
Arm Description
All patients will undergo PET-MR myocardial perfusion imaging during rapid intravenous administration of 0.4 mg regadenoson.
Intervention Type
Drug
Intervention Name(s)
Regadenoson
Other Intervention Name(s)
Lexiscan
Intervention Description
Regadenoson 400 micrograms will be administered in a single IV bolus (<10 seconds) via an antecubital cannula and followed by 5 mL of saline flush. 10-20 seconds after the regadenoson is administered, 10 mCi of 13N-ammonia as a bolus, and 0.075 mmol/Kg of gadobenate dimeglumine MR contrast agent at a rate of 5 mL/sec followed by a 15 mL normal saline flush will be administered simultaneous, each into an antecubital vein, and a 15 min list-mode PET acquisition will be acquired simultaneously with the MR perfusion imaging.
Primary Outcome Measure Information:
Title
Diagnostic Accuracy of Cardiac PET/MRI Examination
Description
The accuracy of the cardiac PET and cardiac MR examination components of the PET/MRI, and the accuracy of the combined PET/MR examination, for ischemic heart disease will be compared to the accuracy of cardiac SPECT in patients who have had ICA as "truth" or the reference standard. To assess the accuracy of an abbreviated PET/MR examination, an additional accuracy analysis was made using only the stress PET perfusion imaging and the MR LGE data sets. The accuracy of this combined data set was also determined with ICA as "truth" or the reference standard. Accuracy is calculated as % difference = (experimental - true) x 100%.
Time Frame
PET/MRI imaging was performed within 10 days after SPECT-MPI examination

10. Eligibility

Sex
All
Minimum Age & Unit of Time
18 Years
Accepts Healthy Volunteers
No
Eligibility Criteria
Inclusion Criteria: Patients who have had a clinically ordered rest/regadenoson single-isotope SPECT-MPI study within 10 days prior to cardiac PET-MRI examination Reversible perfusion abnormalities on SPECT imaging in at least 2 contiguous myocardial segments Patients for whom standard of care coronary ICA is planned Exclusion Criteria: An clinical event (ie; worsening angina pectoris or myocardial infarction) occuring after the SPECT-MPI and before the cardiac MRI examination Myocardial revascularization occuring after the SPECT-MPI and before the cardiac MRI examination Contraindications to MR imaging (pacemaker, brain aneurysm clips, shrapnel, etc.) Renal insufficiency (GFR < 60 mL/min/1.73m2) Allergy or other contraindication to gadolinium-based MR contrast agent Second or third degree atrioventricular (AV) block Active asthma Seizures Current hypotension (<100/60) Current hypertension (>160/90) Pregnancy Breast feeding Use of caffeine, nicotine or over the counter cold medicines within 12 hours of the cardiac PET-MRI examination Use of the medication dipyridamole within 48 hrs of the cardiac PET-MRI examination
Overall Study Officials:
First Name & Middle Initial & Last Name & Degree
Pamela K Woodard, MD, BA
Organizational Affiliation
Washington University School of Medicine
Official's Role
Principal Investigator
Facility Information:
Facility Name
Center for Clinical Imaging Research at Washington University School of Medicine
City
Saint Louis
State/Province
Missouri
ZIP/Postal Code
63110
Country
United States

12. IPD Sharing Statement

Plan to Share IPD
No
IPD Sharing Plan Description
Analyzed data will be shared with other researchers after publication of manuscript.

Learn more about this trial

Development of a PET-MR Myocardial Perfusion Examination Using Regadenoson

We'll reach out to this number within 24 hrs