search
Back to results

Laparoscopic Repair of Giant Hiatal Hernias With Nitinol-framed Lightweight Polytetrafluoroethylene Mesh (GIANT)

Primary Purpose

Hernia, Hiatal

Status
Unknown status
Phase
Phase 3
Locations
Ukraine
Study Type
Interventional
Intervention
Nitinol-framed lightweight PTFE mesh for hiatal repair
Partially absorbable lightweight mesh for hiatal repair
Sponsored by
Odessa National Medical University
About
Eligibility
Locations
Arms
Outcomes
Full info

About this trial

This is an interventional treatment trial for Hernia, Hiatal focused on measuring Hiatal hernia, Gastro-oesophageal reflux disease, Laparoscopic hiatal repair, Laparoscopic anti-reflux surgery, Partially absorbable lightweight mesh, Polytetrafluoroethylene, PTFE, Nitinol, Nitinol-framed lightweight PTFE mesh

Eligibility Criteria

20 Years - 80 Years (Adult, Older Adult)All SexesDoes not accept healthy volunteers

Inclusion Criteria:

  • Type II and III hiatal hernias, including complicated by GERD,
  • Able to undergo elective laparoscopic hiatal hernia repair,
  • Able to 24 months follow-up with office examinations,
  • Hiatal surface area (HSA) exceeding 20 sq.cm (by Granderath et al, 2007) which correspond to the diameter of hernia defect exceeding 8 cm (the distinct size is determined intraoperatively, those with smaller diameter will be excluded from the study),
  • Nissen fundoplication (intraoperative criterion)

Exclusion Criteria:

  • Unable to undergo laparoscopic hiatal hernia repair due to: severe comorbidities (ASA III and more), previous major surgery with severe adhesions, etc.
  • Cases of conversion to open surgery
  • Age < 20 years and > 80 years
  • BMI < 16 and > 39 kg/sq.m
  • Pregnancy or plans for pregnancy within next 2 years (in females)
  • Uncorrectable coagulopathy and immunosuppression
  • Oesophageal motility disorders
  • Oesophageal peptic strictures
  • Oesophageal diverticula, other types (i.e. non-reflux) of chronic esophagitis, connective tissue disorders (e.g. scleroderma)
  • Oesophageal shortening (determined intraoperatively as inability to achieve intra-abdominal length of oesophagus at least 3 cm in spite of intramediastinal oesophageal mobilization)
  • Barrett's oesophagus
  • History of oesophageal/gastric/duodenal surgery including vagotomy
  • Relapsing course of ulcer disease/hyperacid gastritis including complicated by delayed gastric/duodenal emptying

Sites / Locations

  • Department of surgery No. 1 of Odessa national medical university, Odessa regional hospital

Arms of the Study

Arm 1

Arm 2

Arm Type

Active Comparator

Active Comparator

Arm Label

Nitinol-framed PTFE mesh hiatal repair

Lightweight mesh hiatal repair

Arm Description

Nitinol-framed lightweight PTFE mesh for hiatal repair

Partially absorbable lightweight mesh for hiatal repair

Outcomes

Primary Outcome Measures

Anatomical and functional recurrence of hiatal hernia and GERD
Recurrence of hiatal hernia, i.e. anatomical recurrence, will be assessed by symptom questionnaire with visual analogue scales, mainly by barium study, and data from possible redo procedures. Recurrence of GERD, i.e. functional recurrence, will be evaluated by symptom questionnaire with visual analogue scales, endoscopic examination with assessment of degree of reflux-oesophagitis according to Los-Angeles classification, and 24 hour pH-testing with calculation of DeMeester score.

Secondary Outcome Measures

Repair-related dysphagia/oesophageal stricture/prosthetic erosion
Long-term dysphagia, including due to repair-related oesophageal stricture, will be assessed by symptom questionnaire with visual analogue scales, barium study, endoscopic examination, and data from possible redo procedures. Patients also will be endoscopically assessed for such rare complication as prosthetic erosion of oesophagus.
Quality of life and satisfaction
Quality of life and satisfaction will be assessed by GERD-HRQL score
Morbidity
Time to discharge
Time to discharge will be measured in days, from the day of primary surgical procedure, i.e. laparoscopic hiatal hernia repair, to the day of discharge from the hospital
Number of participants completely recovered from extra-oesophageal complications of hiatal hernia following surgical procedure
Extra-oesophageal complications of hiatal hernia to be assessed are: asthma, chronic obstructive pulmonary disease, laryngitis, angina, and arrhythmias

Full Information

First Posted
January 26, 2013
Last Updated
June 28, 2016
Sponsor
Odessa National Medical University
search

1. Study Identification

Unique Protocol Identification Number
NCT01780285
Brief Title
Laparoscopic Repair of Giant Hiatal Hernias With Nitinol-framed Lightweight Polytetrafluoroethylene Mesh
Acronym
GIANT
Official Title
Prospective Randomized Phase III Study of Laparoscopic Repair of Giant Hiatal Hernias With Nitinol-framed Lightweight Polytetrafluoroethylene Mesh
Study Type
Interventional

2. Study Status

Record Verification Date
June 2016
Overall Recruitment Status
Unknown status
Study Start Date
June 2013 (undefined)
Primary Completion Date
January 2015 (Actual)
Study Completion Date
February 2017 (Anticipated)

3. Sponsor/Collaborators

Responsible Party, by Official Title
Principal Investigator
Name of the Sponsor
Odessa National Medical University

4. Oversight

Data Monitoring Committee
No

5. Study Description

Brief Summary
This study is prospective randomized trial enrolling at least 50 participants which compares efficacy and safety of two alternative methods of laparoscopic hiatal repair for giant (i.e. with hiatal surface area (HSA) exceeding 20 sq.cm) types II and III hiatal hernias: partially absorbable lightweight mesh repair, and nitinol-framed lightweight polytetrafluoroethylene (PTFE) mesh repair. In the literature, mean rate of anatomical recurrence of giant hiatal hernias is 25 %, reaching 42 %. Polypropylene and composite PTFE meshes used most widely, result in unacceptable rates of long-term dysphagia (10-15 %) and oesophageal strictures. Own experience of the interventors of more than 400 repairs using partially absorbable lightweight mesh Ultrapro (Ethicon) and original sub-lay technique of its fixation precluding contact of the mesh with the oesophagus, showed low recurrence rate for large hernias and a few cases of long-term dysphagia. For giant hiatal hernias, this technique provides acceptable results (20 % of recurrence) which correspond to the literature. Nevertheless, these results may be improved, probably by using of new type of prosthesis. Thus, in collaboration with Minnesota Medical Development, Inc., USA, the interventors created fundamentally new method of hiatal repair by using new prosthesis - Rebound HRD-Hiatus hernia. This prosthesis is heart-shaped lightweight PTFE mesh with peripheral nitinol frame. It is easily fixated to the crura posteriorly to the oesophagus completely covering hernia defect, and supports a strong framework of the hiatus, and, therefore, allows to save a principle a real tension-free repair. Mid-term results (mean follow-up period of 15 months) of 29 procedures showed no recurrences or oesophageal complications. Naturally, final conclusions regarding superiority of the new technique could be established by prospective randomized study. The hypothesis of the current trial is: new method of nitinol-framed lightweight PTFE mesh repair is more effective in terms of recurrence rate compared to sub-lay partially absorbable lightweight mesh repair, and is characterized by at least similar safety in terms of oesophageal complications. The long-term results (24 months post surgery for every patient) will be studied using symptom questionnaires, quality of life and satisfaction questionnaires, barium studies, endoscopic examinations, 24-hour pH testing, and analysis of possible reoperations.
Detailed Description
Giant hiatal hernias, i.e. hernias with hiatal surface area (HSA), as described by Granderath et al (2007), exceeding 20 sq.cm, is one of the most challenging problem in minimally invasive gastrointestinal surgery. On one hand, according to the literature, the rate of utilization of laparoscopic repair of such hernias does not exceed 80 % [Nguyen et al, 2011]. It means that great proportion of patients is still treated using open approach producing 8 % of postoperative complications [Nguyen et al, 2011]. Therefore, improvement of laparoscopic techniques for this disorder is very actual question. On the other hand, the mean rate of anatomical recurrence following laparoscopic repair of paraoesophageal hernias is 25 % as reported in a meta-analysis [Rathore et al, 2007]. It reaches 42 % in some centers according to recent literature reviews [Draaisma et al, 2005; Johnson et al, 2006]. Hence, creation of new method of hiatal repair diminishing recurrence rate is essential. To interventors' opinion, this new method must follow at least a principle of tension-free repair. As the most concerning problem or repair of giant hiatal hernias is anatomical recurrence, a conception of prosthetic repair was applied for hiatal closure using different types of meshes. This dramatically decreased recurrence rate as demonstrated by several recent studies. Namely, Frantzides et al (2002) prospectively compared primary repair with on-lay PTFE repair and obtained statistically significant decrease of recurrence rate in favor of mesh arm: 0% versus 22%. Then, Granderath et al (2004) compared primary suturing and on-lay polypropylene mesh repair in prospective randomized trial; the rate of recurrence was significantly lower in the mesh arm: 8% versus 26%. Unfortunately, these studies were not primarily addressed to relation between hernia size and results. Most specialists use mesh when the diameter of the defect is just greater than 5 cm, based on own experience and widespread literature data, including studies of Champion et al (1998, 2003). Hiatal surface area (HSA), first described by Granderath et al (2007), is more sensitive measure than diameter of hiatal hernia defect, and further trials should focus on it. However, SAGES trial reported by Frantzides et al. (2010) showed that polypropylene or PTFE meshes are characterized by the highest incidence of oesophageal complications although they demonstrated relatively lower recurrence rates compared to other meshes. According to most of the literature, mesh-related dysphagia rate is 10-15 % in the long-term follow-up [Granderath et al, 2005, Targarona et al, 2004]. Interestingly, that composite, i.e. partially absorbable meshes, occupied middle position in terms of recurrence and complications rates in this study [Frantzides et al, 2010]. Own experience of the interventors of more than 400 laparoscopic hiatal repairs using lightweight partially absorbable mesh (Ultrapro, Ethicon) showed minimal rate of recurrence (4,9 %) and dysphagia (2,1 %) for large (HSA 10-20 sq.cm) hernias [Grubnik et al, 2011]. The interventors applied this safe technique for giant (HSA > 20 sq.cm) hiatal hernias, but recurrence rate was 20 % [Grubnik et al, 2011]. This result corresponds to the literature, but may be improved. The interventors believe, it is possible to minimize recurrence rate of giant hiatal hernias, but it could be achieved by introduction of fundamentally new types of prostheses and methods of its fixation. To remove the risk of mesh-related oesophageal complications of polypropylene or PTFE meshes, biological prostheses were introduced for hiatal repair. However, prospective randomized study by Oelschlager et al (2010) demonstrated insignificant difference in recurrence rates in prosthesis arm compared to primary repair arm (more than 50 %), although no cases of mesh-related complications were observed in prosthesis arm. Similar data regarding biological prostheses were retrieved in the study of Frantzides et al (2010). Data from the literature and international congresses suggest that current biological prostheses cannot be widely used in the setting of giant hiatal hernias due to high rate of recurrences and their high price. Thus, based on current literature data, there is insufficient grade 1 evidence for choice of optimal method of repair of giant hiatal hernias, and the search for the optimal prosthesis is still ongoing. Therefore, a fundamentally new prosthesis for laparoscopic repair of giant hiatal defects was created. The prototype prosthesis "Rebound HRD-Hiatus hernia" was created by the interventors in collaboration with U.S. company, Minnesota Medical Development, Inc. This device is made from high quality lightweight PTFE mesh attached to a heart-shaped nitinol frame with a notch for oesophagus. Prosthesis may be easily inserted through the trocar using a special tube, and expanded to its initial form inside the abdomen. The principle and purpose of using of the device and method of its fixation was patented in Ukraine (patents No. 66397, 66399). The interventors applied new prosthesis in 29 patients, operated from 2010. All procedures were successfully completed. Two main principles are used in a new prosthesis. First, mesh is made of lightweight PTFE minimizing possibility of adhesions and related complications. As a result, there were no esophageal complications in the cohort. Second, peripheral nitinol frame of the prosthesis provides real tension-free repair without risk of prolapse between free, i.e. anterior, margin of the mesh and oesophagus, which other meshes do if fixed to the borders of the hiatus. As a result, there were no recurrences within mean surveillance of 15 months in this series. Naturally, final conclusions regarding superior efficacy and safety of the new device could be established by prospective randomized study. Therefore, the hypothesis of this double-blind prospective randomized trial is: new method of nitinol-framed lightweight PTFE mesh (Rebound HRD-Hiatus hernia, Minnesota Medical Development, Inc) repair is more effective in terms of recurrence rate compared to sub-lay partially absorbable lightweight mesh (Ultrapro, Ethicon, Inc) repair, and is characterized by at least similar safety in terms of oesophageal complications. The study will enroll at least 50 patients with giant (HSA > 20 sq.cm) types II and III hiatal hernias. The basic eligibility criteria will be: absence of oesophageal motility disorders, absence of oesophageal shortening requiring Collis procedure, absence of Barrett's oesophagus, peptic strictures and other factors that may independently influence the rate of recurrence and dysphagia/oesophageal strictures. Thus, the only difference between arms will be method of hiatal closure. To exclude fundoplication-related bias, standard floppy-Nissen procedure will be performed in every patient. Every patient will be operated by single surgical team with an experience of more than 1500 laparoscopic anti-reflux procedures since 1998. The necessary ethic regulations will be saved including informed consent with the statement that patient is unaware of the method of repair (double-masked). Every patient will be evaluated preoperatively, 6 months, and 24 months postoperatively using symptom questionnaires, quality of life and satisfaction questionnaires, barium studies, endoscopic examinations, 24-hour pH testing, and analysis of possible reoperations. For issue of efficacy of prosthetic repair, recurrence rate of hernia and GERD, which are the primary outcome measure, will be studied. For issue of safety of prosthetic repair, rates of long-term dysphagia/oesophageal strictures/mesh erosions, which are main secondary outcome measure, will be evaluated.

6. Conditions and Keywords

Primary Disease or Condition Being Studied in the Trial, or the Focus of the Study
Hernia, Hiatal
Keywords
Hiatal hernia, Gastro-oesophageal reflux disease, Laparoscopic hiatal repair, Laparoscopic anti-reflux surgery, Partially absorbable lightweight mesh, Polytetrafluoroethylene, PTFE, Nitinol, Nitinol-framed lightweight PTFE mesh

7. Study Design

Primary Purpose
Treatment
Study Phase
Phase 3
Interventional Study Model
Parallel Assignment
Masking
ParticipantOutcomes Assessor
Allocation
Randomized
Enrollment
50 (Anticipated)

8. Arms, Groups, and Interventions

Arm Title
Nitinol-framed PTFE mesh hiatal repair
Arm Type
Active Comparator
Arm Description
Nitinol-framed lightweight PTFE mesh for hiatal repair
Arm Title
Lightweight mesh hiatal repair
Arm Type
Active Comparator
Arm Description
Partially absorbable lightweight mesh for hiatal repair
Intervention Type
Device
Intervention Name(s)
Nitinol-framed lightweight PTFE mesh for hiatal repair
Other Intervention Name(s)
Rebound HRD-Hiatus hernia
Intervention Description
The heart-shaped nitinol-framed lightweight PTFE prosthesis "Rebound HRD-Hiatus hernia" (Minnesota Medical Development, Inc.) of small (4,0 x 4,5 cm) to large size (5,5 х 6,0 cm) is sutured to the crura posteriorly to oesophagus with 3 or 5 interrupted non-absorbable (Ethibond 3-0 by Ethicon, Inc.) sutures, thus performing complete tension-free hiatal repair.
Intervention Type
Device
Intervention Name(s)
Partially absorbable lightweight mesh for hiatal repair
Other Intervention Name(s)
Ultrapro
Intervention Description
A fashioned according to the dimensions of hernia defect partially absorbable lightweight mesh Ultrapro (Ethicon, Inc.) will be sutured to both crura posteriorly to oesophagus with 3 to 5 interrupted non-absorbable (Ethibond 3-0 by Ethicon, Inc.) sutures (as tension-free repair). Subsequent 2 to 3 interrupted non-absorbable sutures will approximate crura to completely cover a mesh to preclude its contact with the esophagus (original "sandwich" sub-lay technique). In both arms procedure will be done in a standard fashion: placement of 30 Fr esophageal bougie, reduction of hernia with excision of hernia sac and mobilization of distal esophagus, exposure of borders of hiatal opening, repair of hiatal hernia defect, a short (2,5 - 3,5 cm) 360° fundoplication wrap (floppy-Nissen procedure).
Primary Outcome Measure Information:
Title
Anatomical and functional recurrence of hiatal hernia and GERD
Description
Recurrence of hiatal hernia, i.e. anatomical recurrence, will be assessed by symptom questionnaire with visual analogue scales, mainly by barium study, and data from possible redo procedures. Recurrence of GERD, i.e. functional recurrence, will be evaluated by symptom questionnaire with visual analogue scales, endoscopic examination with assessment of degree of reflux-oesophagitis according to Los-Angeles classification, and 24 hour pH-testing with calculation of DeMeester score.
Time Frame
24 months
Secondary Outcome Measure Information:
Title
Repair-related dysphagia/oesophageal stricture/prosthetic erosion
Description
Long-term dysphagia, including due to repair-related oesophageal stricture, will be assessed by symptom questionnaire with visual analogue scales, barium study, endoscopic examination, and data from possible redo procedures. Patients also will be endoscopically assessed for such rare complication as prosthetic erosion of oesophagus.
Time Frame
24 months
Title
Quality of life and satisfaction
Description
Quality of life and satisfaction will be assessed by GERD-HRQL score
Time Frame
24 months
Title
Morbidity
Time Frame
1 month
Title
Time to discharge
Description
Time to discharge will be measured in days, from the day of primary surgical procedure, i.e. laparoscopic hiatal hernia repair, to the day of discharge from the hospital
Time Frame
1 month
Title
Number of participants completely recovered from extra-oesophageal complications of hiatal hernia following surgical procedure
Description
Extra-oesophageal complications of hiatal hernia to be assessed are: asthma, chronic obstructive pulmonary disease, laryngitis, angina, and arrhythmias
Time Frame
24 months

10. Eligibility

Sex
All
Minimum Age & Unit of Time
20 Years
Maximum Age & Unit of Time
80 Years
Accepts Healthy Volunteers
No
Eligibility Criteria
Inclusion Criteria: Type II and III hiatal hernias, including complicated by GERD, Able to undergo elective laparoscopic hiatal hernia repair, Able to 24 months follow-up with office examinations, Hiatal surface area (HSA) exceeding 20 sq.cm (by Granderath et al, 2007) which correspond to the diameter of hernia defect exceeding 8 cm (the distinct size is determined intraoperatively, those with smaller diameter will be excluded from the study), Nissen fundoplication (intraoperative criterion) Exclusion Criteria: Unable to undergo laparoscopic hiatal hernia repair due to: severe comorbidities (ASA III and more), previous major surgery with severe adhesions, etc. Cases of conversion to open surgery Age < 20 years and > 80 years BMI < 16 and > 39 kg/sq.m Pregnancy or plans for pregnancy within next 2 years (in females) Uncorrectable coagulopathy and immunosuppression Oesophageal motility disorders Oesophageal peptic strictures Oesophageal diverticula, other types (i.e. non-reflux) of chronic esophagitis, connective tissue disorders (e.g. scleroderma) Oesophageal shortening (determined intraoperatively as inability to achieve intra-abdominal length of oesophagus at least 3 cm in spite of intramediastinal oesophageal mobilization) Barrett's oesophagus History of oesophageal/gastric/duodenal surgery including vagotomy Relapsing course of ulcer disease/hyperacid gastritis including complicated by delayed gastric/duodenal emptying
Overall Study Officials:
First Name & Middle Initial & Last Name & Degree
Volodymyr V. Grubnik, Prof., MD
Organizational Affiliation
Department of surgery No. 1 of Odessa national medical university
Official's Role
Principal Investigator
Facility Information:
Facility Name
Department of surgery No. 1 of Odessa national medical university, Odessa regional hospital
City
Odessa
State/Province
Ukaraine
ZIP/Postal Code
65025
Country
Ukraine

12. IPD Sharing Statement

Citations:
PubMed Identifier
16151684
Citation
Draaisma WA, Gooszen HG, Tournoij E, Broeders IA. Controversies in paraesophageal hernia repair: a review of literature. Surg Endosc. 2005 Oct;19(10):1300-8. doi: 10.1007/s00464-004-2275-3. Epub 2005 Aug 4.
Results Reference
background
PubMed Identifier
12049534
Citation
Frantzides CT, Madan AK, Carlson MA, Stavropoulos GP. A prospective, randomized trial of laparoscopic polytetrafluoroethylene (PTFE) patch repair vs simple cruroplasty for large hiatal hernia. Arch Surg. 2002 Jun;137(6):649-52. doi: 10.1001/archsurg.137.6.649.
Results Reference
background
PubMed Identifier
15655204
Citation
Granderath FA, Schweiger UM, Kamolz T, Asche KU, Pointner R. Laparoscopic Nissen fundoplication with prosthetic hiatal closure reduces postoperative intrathoracic wrap herniation: preliminary results of a prospective randomized functional and clinical study. Arch Surg. 2005 Jan;140(1):40-8. doi: 10.1001/archsurg.140.1.40.
Results Reference
background
PubMed Identifier
23272622
Citation
Grubnik VV, Malinovskii AV. [Analysis of long-term results of laparoscopic repair of hiatal hernias and Nissen fundoplication]. Klin Khir. 2012 Oct;(10):34-6. No abstract available. Russian.
Results Reference
background
PubMed Identifier
21715189
Citation
Oelschlager BK, Pellegrini CA, Hunter JG, Brunt ML, Soper NJ, Sheppard BC, Polissar NL, Neradilek MB, Mitsumori LM, Rohrmann CA, Swanstrom LL. Biologic prosthesis to prevent recurrence after laparoscopic paraesophageal hernia repair: long-term follow-up from a multicenter, prospective, randomized trial. J Am Coll Surg. 2011 Oct;213(4):461-8. doi: 10.1016/j.jamcollsurg.2011.05.017. Epub 2011 Jun 29. Erratum In: J Am Coll Surg. 2011 Dec;213(6):815.
Results Reference
background
Citation
Champion JK, McKernan JB. Hiatal size and risk of recurrence after laparoscopic fundoplication [abstract]. Surg Endosc. 1998; 12:565-570.
Results Reference
background
PubMed Identifier
12582773
Citation
Champion JK, Rock D. Laparoscopic mesh cruroplasty for large paraesophageal hernias. Surg Endosc. 2003 Apr;17(4):551-3. doi: 10.1007/s00464-002-8817-7. Epub 2003 Feb 17.
Results Reference
background
PubMed Identifier
19997755
Citation
Frantzides CT, Carlson MA, Loizides S, Papafili A, Luu M, Roberts J, Zeni T, Frantzides A. Hiatal hernia repair with mesh: a survey of SAGES members. Surg Endosc. 2010 May;24(5):1017-24. doi: 10.1007/s00464-009-0718-6. Epub 2009 Dec 8.
Results Reference
background
PubMed Identifier
17103275
Citation
Granderath FA, Schweiger UM, Pointner R. Laparoscopic antireflux surgery: tailoring the hiatal closure to the size of hiatal surface area. Surg Endosc. 2007 Apr;21(4):542-8. doi: 10.1007/s00464-006-9041-7. Epub 2006 Nov 14.
Results Reference
background
PubMed Identifier
16437267
Citation
Johnson JM, Carbonell AM, Carmody BJ, Jamal MK, Maher JW, Kellum JM, DeMaria EJ. Laparoscopic mesh hiatoplasty for paraesophageal hernias and fundoplications: a critical analysis of the available literature. Surg Endosc. 2006 Mar;20(3):362-6. doi: 10.1007/s00464-005-0357-5. Epub 2006 Jan 25.
Results Reference
background
PubMed Identifier
22127087
Citation
Nguyen NT, Christie C, Masoomi H, Matin T, Laugenour K, Hohmann S. Utilization and outcomes of laparoscopic versus open paraesophageal hernia repair. Am Surg. 2011 Oct;77(10):1353-7.
Results Reference
background
PubMed Identifier
18237510
Citation
Rathore MA, Andrabi SI, Bhatti MI, Najfi SM, McMurray A. Metaanalysis of recurrence after laparoscopic repair of paraesophageal hernia. JSLS. 2007 Oct-Dec;11(4):456-60.
Results Reference
background
PubMed Identifier
15611451
Citation
Targarona EM, Bendahan G, Balague C, Garriga J, Trias M. Mesh in the hiatus: a controversial issue. Arch Surg. 2004 Dec;139(12):1286-96; discussion 1296. doi: 10.1001/archsurg.139.12.1286.
Results Reference
background
PubMed Identifier
23877759
Citation
Grubnik VV, Malynovskyy AV. Laparoscopic repair of hiatal hernias: new classification supported by long-term results. Surg Endosc. 2013 Nov;27(11):4337-46. doi: 10.1007/s00464-013-3069-2. Epub 2013 Jul 23.
Results Reference
background

Learn more about this trial

Laparoscopic Repair of Giant Hiatal Hernias With Nitinol-framed Lightweight Polytetrafluoroethylene Mesh

We'll reach out to this number within 24 hrs