Feasibility Study of Remote Support for Implantable Pulse Generator (IPG)/Implantable Cardioverter Defibrillator (ICD) Implant
Primary Purpose
Bradycardia, Sudden Cardiac Arrest
Status
Completed
Phase
Not Applicable
Locations
United States
Study Type
Interventional
Intervention
Remote Implant Support Capability
Sponsored by
About this trial
This is an interventional supportive care trial for Bradycardia focused on measuring Pacemaker, Defibrillator, Remote Consultation
Eligibility Criteria
Inclusion Criteria:
- Planned IPG implant or planned ICD (without CRT) implant
- Signed informed consent
Exclusion Criteria:
- Pacing dependency
- Defibrillation threshold testing planned
- Basal ventricular rate >110 beats per minute
- Younger than 18 years
- Pregnant
- Currently involved in another IPG or ICD related clinical trial
Sites / Locations
- Centennial Heart
Arms of the Study
Arm 1
Arm Type
Experimental
Arm Label
Remote Implant Support
Arm Description
Implant supported through remote implant support capability
Outcomes
Primary Outcome Measures
System Integrity
Percentage of patients whose implantable devices with clinically equivalent programming by remote support and local support.
Successful Support
Percentage of implant attempts with successful support. If the local support person does not participate in any part of the surgery, other than observing, then the remote support will be called a success.
Secondary Outcome Measures
Full Information
NCT ID
NCT01809652
First Posted
March 11, 2013
Last Updated
April 23, 2014
Sponsor
Medtronic Cardiac Rhythm and Heart Failure
1. Study Identification
Unique Protocol Identification Number
NCT01809652
Brief Title
Feasibility Study of Remote Support for Implantable Pulse Generator (IPG)/Implantable Cardioverter Defibrillator (ICD) Implant
Official Title
Remote Implant Support
Study Type
Interventional
2. Study Status
Record Verification Date
April 2014
Overall Recruitment Status
Completed
Study Start Date
December 2013 (undefined)
Primary Completion Date
April 2014 (Actual)
Study Completion Date
April 2014 (Actual)
3. Sponsor/Collaborators
Responsible Party, by Official Title
Sponsor
Name of the Sponsor
Medtronic Cardiac Rhythm and Heart Failure
4. Oversight
Data Monitoring Committee
No
5. Study Description
Brief Summary
The purpose of this study is to gain real world, live implant experience with the remote implant support system. This system is intended to provide the technical support for device implants from a remote location through telepresence (audio and video) and remote control. Specifically, the goals of this study are to corroborate bench testing, assess the performance of the system, gain understanding of the workflows, customer experience, and logistics.
The intent of the remote support model is to provide the same support that would typically be provided by a local support person, only remotely. As such, the remote support person would only perform actions that a local support person would routinely do under the direction of a physician. This may involve observing patient data, providing technical support and advice, and performing testing and device reprogramming via remote control of the programmer.
6. Conditions and Keywords
Primary Disease or Condition Being Studied in the Trial, or the Focus of the Study
Bradycardia, Sudden Cardiac Arrest
Keywords
Pacemaker, Defibrillator, Remote Consultation
7. Study Design
Primary Purpose
Supportive Care
Study Phase
Not Applicable
Interventional Study Model
Single Group Assignment
Masking
None (Open Label)
Allocation
N/A
Enrollment
37 (Actual)
8. Arms, Groups, and Interventions
Arm Title
Remote Implant Support
Arm Type
Experimental
Arm Description
Implant supported through remote implant support capability
Intervention Type
Other
Intervention Name(s)
Remote Implant Support Capability
Intervention Description
Use of audio and video telepresence and remote control of device programmer to allow implant to be supported from a remote location
Primary Outcome Measure Information:
Title
System Integrity
Description
Percentage of patients whose implantable devices with clinically equivalent programming by remote support and local support.
Time Frame
At implant
Title
Successful Support
Description
Percentage of implant attempts with successful support. If the local support person does not participate in any part of the surgery, other than observing, then the remote support will be called a success.
Time Frame
At implant
10. Eligibility
Sex
All
Minimum Age & Unit of Time
18 Years
Accepts Healthy Volunteers
No
Eligibility Criteria
Inclusion Criteria:
Planned IPG implant or planned ICD (without CRT) implant
Signed informed consent
Exclusion Criteria:
Pacing dependency
Defibrillation threshold testing planned
Basal ventricular rate >110 beats per minute
Younger than 18 years
Pregnant
Currently involved in another IPG or ICD related clinical trial
Facility Information:
Facility Name
Centennial Heart
City
Nashville
State/Province
Tennessee
ZIP/Postal Code
37203
Country
United States
12. IPD Sharing Statement
Learn more about this trial
Feasibility Study of Remote Support for Implantable Pulse Generator (IPG)/Implantable Cardioverter Defibrillator (ICD) Implant
We'll reach out to this number within 24 hrs