This is an interventional supportive care trial for Spinal Cord Injuries

Eligibility Criteria

18 Years - 80 Years (Adult, Older Adult)All SexesDoes not accept healthy volunteers

Inclusion Criteria:

  • Lower extremity functional impairment due to neurologic or neuromuscular disease, orthopedic disease or trauma.
  • Prior active and compliant use of unilateral Knee-ankle-foot orthosis (KAFO) or Stance control orthosis (SCO).
  • Age 18 - 80 years.
  • Demonstrate a reciprocal gait pattern using the SCO and C-Brace trial tools.
  • Cognitive ability to understand and the willingness to sign a written informed consent.
  • Subjects must be able to demonstrate the ability to turn the global positioning sensor (GPS) and Actigraph units on and off and sufficient memory ability to wear the devices each day during use of the orthoses.

Exclusion Criteria:

  • Passive ankle range of motion (PROM) of the lower extremity requiring the knee-ankle-foot orthosis (KAFO) of less than 2 degrees.
  • Body weight >275 pounds.
  • Unstable neurological or cardiovascular/pulmonary disease, cancer.
  • Knee flexion contracture resulting in the inability to actively use C-Brace or SCO.
  • Participating in physical therapy currently or within 1 month of starting protocol, specific to orthotic use and gait training.

Sites / Locations

  • Rehabilitation Institute of Chicago

Arms of the Study

Arm 1

Arm 2

Arm Type

Experimental

Experimental

Arm Label

C-brace then stance control orthosis

Stance control orthosis then C-brace

Arm Description

Outcomes

Primary Outcome Measures

Six minute walk test (6MWT)
The test measures the distance that the patient can walk on a flat, hard surface, indoors, in a period of 6 minutes. The walk test is patient self-paced and assesses the level of functional capacity. Patients are allowed to stop and rest during the test, however, the timer does not stop. If the patient is unable to complete the time, the time stopped is noted and reason for stopping prematurely is recorded. This test will be administered while wearing a mask to measure oxygen consumption.

Secondary Outcome Measures

Muscle strength
Muscle strength with be assessed using a hand held dynamometer for muscle strength testing of the lower limb.
Passive and active range of motion
10 meter walk test
This test will examine the patient's gait speed. Patients will be directed to walk at their preferred maximum but safe speed. Patients will be positioned 1 meter before the start line and instructed to walk the entire distance and past the end line approximately 1 meter. The distance before and after the course are meant to minimize the effect of acceleration and deceleration. Time will be recorded using a stopwatch and recorded to the one hundredth of a second (ex: 2.15 sec). The test will be recorded 2 times, with adequate rest in between. The average of the 2 times should be recorded.
Hill Assessment Index
The Hill Assessment Index is a 12 point ordinal scale used to assess different gait patterns during ascent or descent of slopes. It was developed to detect differences in function with different knee units for transfemoral prosthetics.
Stair Assessment Index
The Stair Assessment Index is a 14 point ordinal scale originally used to assess functional abilities during ascent and descent of stairs.
Cross Walk Blinking Signal Test
The cross walk blinking signal test will measure how long it takes a participant to cross a designated street. The street that is designated for the street is 2 lanes and has ramps from the sidewalk to the street. The distance measured will be from the end of the ramp or edge of the curb on either side of the street.
GAITRite Data Capture
The GAITRite system automates measuring temporal and spatial gait parameters via an electronic walkway connected to a computer. The GAITRite electronic walkway contains sensor pads encapsulated in a carpet to collect gait information. The system can be laid over any flat surface. The GAITRite electronic walkway for the study shall be a minimum of 14 feet long. The GAITRite data capture was chosen as measurement of the patient's overall gait quality. Patients will be asked to walk at a self-selected speed across the GAITRite electronic walkway.
Berg Balance Scale
The Berg Balance Scale is a 14-item scale designed to measure balance in adults in a clinical setting. When scoring, the lowest response category that applies should be recorded. In each item, points should be deducted if the time or distance requirements are not met, the subject's performance requires supervision, or the subject requires assistance from support or examiner.
Functional Gait Assessment
The Functional Gait Assessment is a 10 item test used to assess postural stability during walking tasks. It has a maximum score of 30 with each item being scored 0-3. It may be performed with or without an assistive device; however, individuals lose a point on all items requiring a device.
5 times sit to stand test
The 5 Time Sit to Stand Test is a measure of functional lower limb strength during transitional movement. The individual sits in a standard height chair (43-45 cm) and is instructed to stand up and sit down 5 times as quickly as possible.

Full Information

First Posted
February 26, 2014
Last Updated
January 12, 2023
Sponsor
Shirley Ryan AbilityLab
Collaborators
Otto Bock Healthcare Products GmbH
search

1. Study Identification

Unique Protocol Identification Number
NCT02089880
Brief Title
Comparing Functional Outcomes in Individuals Using Micro-processor Controlled Orthosis Versus Stance Control Orthosis
Official Title
Micro-processor Controlled Knee-Ankle-Foot Orthosis (C-Brace) Versus Stance-control Knee-Ankle-Foot Orthosis (SCO): Functional Outcomes in Individuals With Lower Extremity Impairment
Study Type
Interventional

2. Study Status

Record Verification Date
January 2023
Overall Recruitment Status
Active, not recruiting
Study Start Date
February 2014 (Actual)
Primary Completion Date
December 2023 (Anticipated)
Study Completion Date
December 2023 (Anticipated)

3. Sponsor/Collaborators

Responsible Party, by Official Title
Principal Investigator
Name of the Sponsor
Shirley Ryan AbilityLab
Collaborators
Otto Bock Healthcare Products GmbH

4. Oversight

5. Study Description

Brief Summary
The study will specifically evaluate the potential of the C-Brace to improve the functional mobility and quality of life in individuals with lower extremity impairments due to neurologic or neuromuscular disease, orthopedic disease or trauma, as compared to the stance control orthosis.

6. Conditions and Keywords

Primary Disease or Condition Being Studied in the Trial, or the Focus of the Study
Spinal Cord Injuries, Poliomyelitis, Post-polio Syndrome, Arthritis, Lower Motor Neurone Lesion

7. Study Design

Primary Purpose
Supportive Care
Study Phase
Not Applicable
Interventional Study Model
Crossover Assignment
Masking
None (Open Label)
Allocation
Randomized
Enrollment
24 (Anticipated)

8. Arms, Groups, and Interventions

Arm Title
C-brace then stance control orthosis
Arm Type
Experimental
Arm Title
Stance control orthosis then C-brace
Arm Type
Experimental
Intervention Type
Device
Intervention Name(s)
C-brace
Other Intervention Name(s)
C-Brace by Ottobock
Intervention Description
The participant will receive 6 sessions of training over a one month period in using the C-brace in all levels of functional gait. The participant will then continue use of the C-brace for one month following training. The C-Brace from Otto Bock is an orthosis that controls throughout stance and swing phases of gait with a micro-processor (MP) controlled knee.
Intervention Type
Device
Intervention Name(s)
Stance control orthosis
Intervention Description
The participant will receive 6 sessions of training over a one month period in using his current stance control knee-ankle-foot orthosis (SCO) in all levels of functional gait. The participant will then continue use of the SCO for one month following training. The SCO controls the knee by maintaining it straight and extended during the stance phase of gait.
Primary Outcome Measure Information:
Title
Six minute walk test (6MWT)
Description
The test measures the distance that the patient can walk on a flat, hard surface, indoors, in a period of 6 minutes. The walk test is patient self-paced and assesses the level of functional capacity. Patients are allowed to stop and rest during the test, however, the timer does not stop. If the patient is unable to complete the time, the time stopped is noted and reason for stopping prematurely is recorded. This test will be administered while wearing a mask to measure oxygen consumption.
Time Frame
Change from baseline in 6MWT using device 1 at 8 weeks and using device 2 at 16 weeks.
Secondary Outcome Measure Information:
Title
Muscle strength
Description
Muscle strength with be assessed using a hand held dynamometer for muscle strength testing of the lower limb.
Time Frame
Change from baseline in muscle strength after device 1 use at 8 weeks and after device 2 use at 16 weeks.
Title
Passive and active range of motion
Time Frame
Change from baseline in range of motion after device 1 use at 8 weeks and after device 2 use at 16 weeks.
Title
10 meter walk test
Description
This test will examine the patient's gait speed. Patients will be directed to walk at their preferred maximum but safe speed. Patients will be positioned 1 meter before the start line and instructed to walk the entire distance and past the end line approximately 1 meter. The distance before and after the course are meant to minimize the effect of acceleration and deceleration. Time will be recorded using a stopwatch and recorded to the one hundredth of a second (ex: 2.15 sec). The test will be recorded 2 times, with adequate rest in between. The average of the 2 times should be recorded.
Time Frame
Change from baseline in gait speed using device 1 at 8 weeks and using device 2 at 16 weeks.
Title
Hill Assessment Index
Description
The Hill Assessment Index is a 12 point ordinal scale used to assess different gait patterns during ascent or descent of slopes. It was developed to detect differences in function with different knee units for transfemoral prosthetics.
Time Frame
Change from baseline in hill descent using device 1 at 8 weeks and using device 2 at 16 weeks.
Title
Stair Assessment Index
Description
The Stair Assessment Index is a 14 point ordinal scale originally used to assess functional abilities during ascent and descent of stairs.
Time Frame
Change from baseline in stair descent using device 1 at 8 weeks and using device 2 at 16 weeks.
Title
Cross Walk Blinking Signal Test
Description
The cross walk blinking signal test will measure how long it takes a participant to cross a designated street. The street that is designated for the street is 2 lanes and has ramps from the sidewalk to the street. The distance measured will be from the end of the ramp or edge of the curb on either side of the street.
Time Frame
Change from baseline in the Cross Walk Blinking Signal Test using device 1 at 8 weeks and using device 2 at 16 weeks.
Title
GAITRite Data Capture
Description
The GAITRite system automates measuring temporal and spatial gait parameters via an electronic walkway connected to a computer. The GAITRite electronic walkway contains sensor pads encapsulated in a carpet to collect gait information. The system can be laid over any flat surface. The GAITRite electronic walkway for the study shall be a minimum of 14 feet long. The GAITRite data capture was chosen as measurement of the patient's overall gait quality. Patients will be asked to walk at a self-selected speed across the GAITRite electronic walkway.
Time Frame
Change from baseline in gait parameters using device 1 at 8 weeks and using device 2 at 16 weeks.
Title
Berg Balance Scale
Description
The Berg Balance Scale is a 14-item scale designed to measure balance in adults in a clinical setting. When scoring, the lowest response category that applies should be recorded. In each item, points should be deducted if the time or distance requirements are not met, the subject's performance requires supervision, or the subject requires assistance from support or examiner.
Time Frame
Change from baseline in Berg Balance Scale score using device 1 at 8 weeks and using device 2 at 16 weeks.
Title
Functional Gait Assessment
Description
The Functional Gait Assessment is a 10 item test used to assess postural stability during walking tasks. It has a maximum score of 30 with each item being scored 0-3. It may be performed with or without an assistive device; however, individuals lose a point on all items requiring a device.
Time Frame
Change from baseline in Functional Gait Assessment scores using device 1 at 8 weeks and using device 2 at 16 weeks.
Title
5 times sit to stand test
Description
The 5 Time Sit to Stand Test is a measure of functional lower limb strength during transitional movement. The individual sits in a standard height chair (43-45 cm) and is instructed to stand up and sit down 5 times as quickly as possible.
Time Frame
Change from baseline in 5 times sit to stand test using device 1 at 8 weeks and using device 2 at 16 weeks.
Other Pre-specified Outcome Measures:
Title
Modified Falls Efficacy Scale
Description
The Modified Falls Efficacy Scale is self-report questionnaire consisting of 14 items which is designed to measure fear of falling in the elderly. It assesses an individual's perception of balance during activities of daily living by asking "how confident are you that you can do the following activities without falling."
Time Frame
Change from baseline in Modified Falls Efficacy Scale after device 1 use at 8 weeks and after device 2 use at 16 weeks.
Title
Orthotics and Prosthetics User Survey
Description
The Orthotic and Prosthetics User Survey is a self-report questionnaire which is designed to evaluate the outcome of orthotic and prosthetic services. We will administer three of the five domains: lower limb functional measure, health-related quality of life and satisfaction with device.
Time Frame
Change from baseline in Orthotics and Prosthetics User Survey after device 1 use at 8 weeks and after device 2 use at 16 weeks.
Title
World Health Organization Quality of Life, brief form (WHOQOL-BREF)
Description
The WHOQOL-BREF is a self-report questionnaire that measures an individual's perceived quality of life. It contains four domains which cover physical health, psychological health, social relationships, and environment. Scores range from 0-100 with 100 indicating a higher quality of life.
Time Frame
Change from baseline in WHOQOL-BREF after device 1 use at 8 weeks and after device 2 use at 16 weeks.
Title
Global Positioning System (GPS)
Description
GPS will be used to measure community mobility during the home use period, at baseline and after training with each device.
Time Frame
Change from baseline measurement after device 1 training at 8 weeks and after device 2 training at 16 weeks.
Title
Actigraph
Description
The Actigraph is a small accelerometer worn on a belt which can identify performance of functional activities during use.
Time Frame
Change from baseline measurement after device 1 training at 8 weeks and after device 2 training at 16 weeks.
Title
Metria Sensor A wireless wearable sensor used in conjunction with the Actigraph to measure activity and monitor vitals and energy use during functional activities.
Description
The Metria Sensor is a wireless wearable sensor used in conjunction with the Actigraph to measure activity and monitor vitals and energy use during functional activities.
Time Frame
Change from baseline measurement after device 1 training at 8 weeks and after device 2 training at 16 weeks.

10. Eligibility

Sex
All
Minimum Age & Unit of Time
18 Years
Maximum Age & Unit of Time
80 Years
Accepts Healthy Volunteers
No
Eligibility Criteria
Inclusion Criteria: Lower extremity functional impairment due to neurologic or neuromuscular disease, orthopedic disease or trauma. Prior active and compliant use of unilateral Knee-ankle-foot orthosis (KAFO) or Stance control orthosis (SCO). Age 18 - 80 years. Demonstrate a reciprocal gait pattern using the SCO and C-Brace trial tools. Cognitive ability to understand and the willingness to sign a written informed consent. Subjects must be able to demonstrate the ability to turn the global positioning sensor (GPS) and Actigraph units on and off and sufficient memory ability to wear the devices each day during use of the orthoses. Exclusion Criteria: Passive ankle range of motion (PROM) of the lower extremity requiring the knee-ankle-foot orthosis (KAFO) of less than 2 degrees. Body weight >275 pounds. Unstable neurological or cardiovascular/pulmonary disease, cancer. Knee flexion contracture resulting in the inability to actively use C-Brace or SCO. Participating in physical therapy currently or within 1 month of starting protocol, specific to orthotic use and gait training.
Facility Information:
Facility Name
Rehabilitation Institute of Chicago
City
Chicago
State/Province
Illinois
ZIP/Postal Code
60611
Country
United States

12. IPD Sharing Statement

Citations:
PubMed Identifier
32976844
Citation
Deems-Dluhy S, Hoppe-Ludwig S, Mummidisetty CK, Semik P, Heinemann AW, Jayaraman A. Microprocessor Controlled Knee Ankle Foot Orthosis (KAFO) vs Stance Control vs Locked KAFO: A Randomized Controlled Trial. Arch Phys Med Rehabil. 2021 Feb;102(2):233-244. doi: 10.1016/j.apmr.2020.08.013. Epub 2020 Sep 22.
Results Reference
derived

Learn more about this trial

Comparing Functional Outcomes in Individuals Using Micro-processor Controlled Orthosis Versus Stance Control Orthosis

We'll reach out to this number within 24 hrs