Improving Postprandial Glycaemia by a New Developed Closed-loop Control System - Closedloop4meals (CL4M-Controls)

Primary Purpose

Diabetes Mellitus, Type 1

Status
Completed
Phase
Not Applicable
Locations
Spain
Study Type
Interventional
Intervention
Closed-loop insulin infusion system
Open-loop insulin infusion system
Sponsored by
Fundación para la Investigación del Hospital Clínico de Valencia
About
Eligibility
Locations
Arms
Outcomes
Full info

About this trial

This is an interventional treatment trial for Diabetes Mellitus, Type 1 focused on measuring Closed-loop insulin infusion, Postprandial glucose control, Glucose variability

Eligibility Criteria

18 Years - 60 Years (Adult)All SexesDoes not accept healthy volunteers

Inclusion Criteria:

  • Subjects with type 1 diabetes mellitus
  • Continuous subcutaneous insulin infusion (CSII) treatment for at least six months before Visit 1
  • Body mass index of between 18 and 30 kg/m2
  • HbA1c 6.0-8.5% at Visit 1
  • Normal laboratory values, ECG, and vital signs unless the investigator considered an abnormality to be clinically irrelevant
  • Women postmenopausal or using contraception judged by the investigator to be adequate (e.g., oral contraceptives, intra-uterine device or surgical treatment), or with a negative negative urine pregnancy tests at visits 1, 3 and 5

Exclusion Criteria:

  • Pregnancy and lactation
  • History of hypersensitivity to the study medications or to drugs with similar chemical structures
  • Hypoglycaemia unawareness
  • Progressive fatal diseases
  • History of drug or alcohol abuse
  • History of positive HIV or hepatitis B or C test
  • Impaired hepatic function, as shown by, but not limited to, SGPT or SGOT of more than twice the upper limit of the normal range at visit 1
  • Impaired renal function, as shown by, but not limited to, serum creatinine > 1.5 mg/dL at visit 1
  • Clinically relevant microvascular (pre-proliferative and proliferative retinopathy and macroalbuminuria), cardiovascular, hepatic, neurologic, endocrine or other major systemic diseases other than T1DM which could hinder implementation of the clinical study protocol or interpretation of the study results
  • Pre-planned surgery during the study
  • Blood donation of more than 500 ml during the past three months for men, or during the past six months for women
  • Mental condition rendering the subject unable to understand the nature, scope and possible consequences of the study
  • Subject unlikely to comply with clinical study protocol, e.g., uncooperative attitude, inability to return for follow-up visits, or poor likelihood of completing the study
  • Receipt of an experimental drug or use of an experimental device during the past 30 days.

Sites / Locations

  • Hospital Clínic i Universitari de Barcelona
  • Hospital Clínico Universitario de Valencia

Arms of the Study

Arm 1

Arm 2

Arm Type

Active Comparator

Experimental

Arm Label

Open-loop insulin infusion system

Closed-loop insulin infusion system

Arm Description

Standard Open-loop intensive insulin treatment with continuous insulin infusion (CSII). Commercially available insulin infusion systems will be used.

Sliding Mode Reference Conditioning (SMRC) Closed-loop insulin administration. Automated insulin infusion based on subcutaneous continuous glucose monitoring (CGM). Commercially available insulin infusion systems and CGM devices will be used. However, insulin infusion will be driven by the by the software under investigation (CL4M Controls) based on blood glucose estimations from CGM.

Outcomes

Primary Outcome Measures

Intra-subject postprandial glycemic variability
Clinical validation of a new algorithm (glucose controller) for closed-loop control of postprandial glucose in comparison with a standard bolus (open-loop control), in type 1 diabetic subjects using insulin pump therapy. The robustness and effectiveness of the new algorithm for closed-loop glycaemic control (PID controller modified by SMRC-based external loop adjustments) will be evaluated through measurement of intra-subject postprandial glycemic variability expressed as the coefficient of variation (CV) of the area under the curve (AUC) of plasma glucose (PG) during the 8h post-prandial period (CV_AUC-PG_0-8h). The hypothesis is that closed-loop insulin infusion reduces postprandial glucose variability as compared with standard treatment.

Secondary Outcome Measures

CV_AUC-PG_3-8h
Coefficient of variation of the area under the curve (AUC) of plasma glucose (PG) during the late postprandial phase.

Full Information

First Posted
March 27, 2014
Last Updated
November 14, 2015
Sponsor
Fundación para la Investigación del Hospital Clínico de Valencia
Collaborators
Hospital Clinic of Barcelona, Universitat Politècnica de València, Universitat de Girona
search

1. Study Identification

Unique Protocol Identification Number
NCT02100488
Brief Title
Improving Postprandial Glycaemia by a New Developed Closed-loop Control System - Closedloop4meals
Acronym
CL4M-Controls
Official Title
Improving Postprandial Glycaemia by a New Developed Closed-loop Control System (Closedloop4meals). An Interdisciplinary, Investigator's Initiated Project for Optimization of Glucose Control in Type1 Diabetic Subjects
Study Type
Interventional

2. Study Status

Record Verification Date
November 2015
Overall Recruitment Status
Completed
Study Start Date
March 2014 (undefined)
Primary Completion Date
July 2015 (Actual)
Study Completion Date
October 2015 (Actual)

3. Sponsor/Collaborators

Responsible Party, by Official Title
Sponsor
Name of the Sponsor
Fundación para la Investigación del Hospital Clínico de Valencia
Collaborators
Hospital Clinic of Barcelona, Universitat Politècnica de València, Universitat de Girona

4. Oversight

Data Monitoring Committee
No

5. Study Description

Brief Summary
Achieving near-normoglycemia has been established as the main objective for most patients with diabetes. However, postprandial glucose control is a challenging issue in everyday diabetes care. Indeed, excessive postprandial glucose excursions are the major contributors to plasma glucose (PG) variability in subjects with type 1 diabetes (T1DM). In addition, the poor reproducibility of postprandial glucose response is burdensome for patients and healthcare professionals. Automatic glucose control, the so-called artificial pancreas or closed-loop system, may represent the ideal solution for reaching the therapeutic goals in diabetic patients. Intuitively, closed-loop insulin delivery may be superior to open-loop insulin delivery due to a better compensation of the variability of subcutaneous insulin absorption and the intra-subject insulin sensitivity. However, several challenges exist to effectively realize an optimal postprandial closed-loop control of blood glucose. Indeed, the eating process induces one of the major glucose perturbations that need to be controlled by an artificial pancreas and is currently one of the main challenges found in clinical validations of the few existing prototypes of an artificial pancreas. In particular, experiments carried out with the currently used algorithms for glucose control (the so called PID and MPC) showed that closed-loop insulin delivery often tend to overcorrect hyperglycemia thus increasing the risk hypoglycemia. In this project, a rigorous clinical testing of a novel closed-loop controller ('artificial pancreas') will be carried out in T1DM patients treated with continuous subcutaneous insulin infusion (CSII). The innovative element of the controller is a safety auxiliary feedback based on sliding mode reference conditioning (SMRC), which has been demonstrated (in simulation studies) to limit over-insulinization and the resulting hypoglycemia, reducing glycaemic variability. Standardized meal test studies will be performed in T1DM subjects treated with CSII, comparing the administration of a classical bolus (open-loop study) with a controller-driven prandial insulin delivery (closed-loop study) based on continuous subcutaneous glucose monitoring (CGM). The hypothesis is that closed loop control will provide better postprandial control, especially in terms of reduction of glucose variability and incidence of hypoglycemia.

6. Conditions and Keywords

Primary Disease or Condition Being Studied in the Trial, or the Focus of the Study
Diabetes Mellitus, Type 1
Keywords
Closed-loop insulin infusion, Postprandial glucose control, Glucose variability

7. Study Design

Primary Purpose
Treatment
Study Phase
Not Applicable
Interventional Study Model
Crossover Assignment
Masking
Participant
Allocation
Randomized
Enrollment
20 (Actual)

8. Arms, Groups, and Interventions

Arm Title
Open-loop insulin infusion system
Arm Type
Active Comparator
Arm Description
Standard Open-loop intensive insulin treatment with continuous insulin infusion (CSII). Commercially available insulin infusion systems will be used.
Arm Title
Closed-loop insulin infusion system
Arm Type
Experimental
Arm Description
Sliding Mode Reference Conditioning (SMRC) Closed-loop insulin administration. Automated insulin infusion based on subcutaneous continuous glucose monitoring (CGM). Commercially available insulin infusion systems and CGM devices will be used. However, insulin infusion will be driven by the by the software under investigation (CL4M Controls) based on blood glucose estimations from CGM.
Intervention Type
Device
Intervention Name(s)
Closed-loop insulin infusion system
Other Intervention Name(s)
CL4M Controls
Intervention Description
Each subject will undergo two "Open-loop" and two "Closed-loop" meal tests, each one at 1-2 week intervals, thus completing the 4 experiments in about 6 weeks. The day of the experiment, a standard mixed meal test containing 60 g of carbohydrates (CHO), will be administered. On two occasions, patients will receive in a randomized order the standard insulin bolus based on the individual insulin to CHO ratio (First arm, Open-loop study). On the other two occasions they will receive a Sliding Mode Reference Conditioning (SMRC) Closed-loop insulin administration, based on subcutaneous continuous glucose monitoring (Second arm, Closed-loop study). Commercial insulin infusion systems and continuous glucose monitoring devices will be used.
Intervention Type
Other
Intervention Name(s)
Open-loop insulin infusion system
Intervention Description
Standard subcutaneous insulin infusion based on the individual insulin to carbohydrate ratio. Commercial insulin infusion systems and continuous glucose monitoring devices will be used.
Primary Outcome Measure Information:
Title
Intra-subject postprandial glycemic variability
Description
Clinical validation of a new algorithm (glucose controller) for closed-loop control of postprandial glucose in comparison with a standard bolus (open-loop control), in type 1 diabetic subjects using insulin pump therapy. The robustness and effectiveness of the new algorithm for closed-loop glycaemic control (PID controller modified by SMRC-based external loop adjustments) will be evaluated through measurement of intra-subject postprandial glycemic variability expressed as the coefficient of variation (CV) of the area under the curve (AUC) of plasma glucose (PG) during the 8h post-prandial period (CV_AUC-PG_0-8h). The hypothesis is that closed-loop insulin infusion reduces postprandial glucose variability as compared with standard treatment.
Time Frame
Eight-hour post-prandial period
Secondary Outcome Measure Information:
Title
CV_AUC-PG_3-8h
Description
Coefficient of variation of the area under the curve (AUC) of plasma glucose (PG) during the late postprandial phase.
Time Frame
the 3-8 hour post-prandial interval
Other Pre-specified Outcome Measures:
Title
AUC_PG_0-8h
Description
Area under the curve of plasma glucose (PG) during the 8h post-prandial period
Time Frame
the 8h post-prandial period
Title
Time into range
Description
Time spent in an acceptable glycaemic range (70-180 mg/dl), during the postprandial period
Time Frame
0-8h post-prandial period

10. Eligibility

Sex
All
Minimum Age & Unit of Time
18 Years
Maximum Age & Unit of Time
60 Years
Accepts Healthy Volunteers
No
Eligibility Criteria
Inclusion Criteria: Subjects with type 1 diabetes mellitus Continuous subcutaneous insulin infusion (CSII) treatment for at least six months before Visit 1 Body mass index of between 18 and 30 kg/m2 HbA1c 6.0-8.5% at Visit 1 Normal laboratory values, ECG, and vital signs unless the investigator considered an abnormality to be clinically irrelevant Women postmenopausal or using contraception judged by the investigator to be adequate (e.g., oral contraceptives, intra-uterine device or surgical treatment), or with a negative negative urine pregnancy tests at visits 1, 3 and 5 Exclusion Criteria: Pregnancy and lactation History of hypersensitivity to the study medications or to drugs with similar chemical structures Hypoglycaemia unawareness Progressive fatal diseases History of drug or alcohol abuse History of positive HIV or hepatitis B or C test Impaired hepatic function, as shown by, but not limited to, SGPT or SGOT of more than twice the upper limit of the normal range at visit 1 Impaired renal function, as shown by, but not limited to, serum creatinine > 1.5 mg/dL at visit 1 Clinically relevant microvascular (pre-proliferative and proliferative retinopathy and macroalbuminuria), cardiovascular, hepatic, neurologic, endocrine or other major systemic diseases other than T1DM which could hinder implementation of the clinical study protocol or interpretation of the study results Pre-planned surgery during the study Blood donation of more than 500 ml during the past three months for men, or during the past six months for women Mental condition rendering the subject unable to understand the nature, scope and possible consequences of the study Subject unlikely to comply with clinical study protocol, e.g., uncooperative attitude, inability to return for follow-up visits, or poor likelihood of completing the study Receipt of an experimental drug or use of an experimental device during the past 30 days.
Overall Study Officials:
First Name & Middle Initial & Last Name & Degree
Francisco Javier Ampudia-Blasco, MD, PhD
Organizational Affiliation
Department of Medicine, Division of Endocrinology and Nutrition, Clinic University Hospital of Valencia - Fundación INCLIVA, University of Valencia, Valencia, Spain.
Official's Role
Principal Investigator
First Name & Middle Initial & Last Name & Degree
Ignacio Conget, MD, PhD
Organizational Affiliation
Unidad de Diabetes. Servicio de Endocrinología y Nutrición, Hospital Clínic i Universitari de Barcelona, Barcelona, Spain
Official's Role
Principal Investigator
First Name & Middle Initial & Last Name & Degree
Jorge Bondia, PhD
Organizational Affiliation
University Institute of Control Systems and Industrial Computing (ai2 Institute), Polytechnic University of Valencia, Valencia, Spain
Official's Role
Study Director
First Name & Middle Initial & Last Name & Degree
Josep Vehí, PhD
Organizational Affiliation
Institute of Informatics and Applications, University of Girona, Girona, Spain
Official's Role
Study Director
Facility Information:
Facility Name
Hospital Clínic i Universitari de Barcelona
City
Barcelona
ZIP/Postal Code
08036
Country
Spain
Facility Name
Hospital Clínico Universitario de Valencia
City
Valencia
ZIP/Postal Code
46010
Country
Spain

12. IPD Sharing Statement

Citations:
PubMed Identifier
23428611
Citation
Revert A, Garelli F, Pico J, De Battista H, Rossetti P, Vehi J, Bondia J. Safety auxiliary feedback element for the artificial pancreas in type 1 diabetes. IEEE Trans Biomed Eng. 2013 Aug;60(8):2113-22. doi: 10.1109/TBME.2013.2247602. Epub 2013 Feb 15.
Results Reference
background
PubMed Identifier
28459603
Citation
Rossetti P, Quiros C, Moscardo V, Comas A, Gimenez M, Ampudia-Blasco FJ, Leon F, Montaser E, Conget I, Bondia J, Vehi J. Closed-Loop Control of Postprandial Glycemia Using an Insulin-on-Board Limitation Through Continuous Action on Glucose Target. Diabetes Technol Ther. 2017 Jun;19(6):355-362. doi: 10.1089/dia.2016.0443. Epub 2017 May 1.
Results Reference
derived

Learn more about this trial

Improving Postprandial Glycaemia by a New Developed Closed-loop Control System - Closedloop4meals

We'll reach out to this number within 24 hrs