search
Back to results

HLT transfemOral Replacement of aortIc Valve Via transcatherteriZatiON (HORIZON)

Primary Purpose

Severe Aortic Stenosis, Aortic Valve Stenosis

Status
Completed
Phase
Not Applicable
Locations
Germany
Study Type
Interventional
Intervention
HLT Transcatheter Aortic Valve System
Sponsored by
HLT Inc.
About
Eligibility
Locations
Arms
Outcomes
Full info

About this trial

This is an interventional treatment trial for Severe Aortic Stenosis focused on measuring Severe aortic stenosis, Aortic valve stenosis, Transcatheter aortic valve replacement

Eligibility Criteria

75 Years - undefined (Older Adult)All SexesDoes not accept healthy volunteers

Inclusion Criteria:

  1. 75 years of age or older
  2. Echocardiographic or hemodynamic based evidence of calcific (senile) aortic stenosis with one of the following: aortic valve EOA <1.0 cm2 or 0.6 cm2/m2 , mean aortic valve gradient >40 mmHg or peak aortic valve velocity >4 m/sec
  3. Symptomatology due to aortic stenosis resulting in a New York Heart Association (NYHA) Functional Classification of II or greater
  4. Aortic valve annular diameter ≥ 21 and ≤23mm measured by MSCT
  5. An STS score ≥10; or Logistic EuroScore I ≥ 15; or a determination by one cardiovascular surgeon and one cardiologist that the co-morbidities not captured by the STS or EuroScore expected to increase the operative mortality risk to > 15%.
  6. Geographically available, willing to comply with follow up and able to provide written informed consent

Exclusion Criteria:

  1. Congenital unicuspid or bicuspid aortic valve, or noncalcified aortic valve; or valve eccentricity (calcific or otherwise) that in the opinion of the investigator could compromise procedural success.
  2. Pre-existing prosthetic heart valve in any position, or prosthetic ring
  3. Severe (Grade 3 to 4) aortic, mitral or tricuspid valve regurgitation
  4. Moderate to severe mitral stenosis
  5. Myocardial infarction within the past 30 days*
  6. Echocardiographic evidence of intracardiac mass, thrombus or vegetation
  7. LVEF < 30%
  8. Uncontrolled hypertension (i.e. blood pressure at baseline > 140 mmHg systolic; or in the opinion of the investigator cannot be controlled by medical therapy).
  9. Severe pulmonary hypertension with pulmonary systolic pressure greater than two-thirds of systemic pressure
  10. Hemodynamic instability requiring inotropic drug therapy within the past 14 days or mechanical support within the past 6 months*
  11. Untreated clinically significant coronary artery disease requiring revascularization
  12. Presence of significant aortic disease such as atheroma, thrombus, or aneurysm which, in the opinion of the investigator, precludes safe implant delivery
  13. Blood dyscrasias defined as: acute leukopenia, acute anemia, acute thrombocytopenia, history of bleeding diathesis or coagulopathy
  14. Patient ineligible for or refuses blood transfusions
  15. Unfavorable peripheral vascular anatomy or disease (e.g. severe obstructive calcification, severe tortuosity or small vessels) that would preclude passage of catheters from the femoral arterial access to the aorta as evidenced by peripheral MSCT
  16. Active peptic ulcer or gastrointestinal bleeding within the past 90 days*
  17. Stroke or transient ischemic attack within past 6 months*
  18. Renal insufficiency as demonstrated by a serum creatinine > 2.5 mg/dL or end stage renal disease requiring chronic dialysis
  19. Active infection requiring ongoing treatment
  20. Need for emergent surgery or intervention other than the investigational procedure
  21. Any therapeutic invasive cardiac procedure performed or planned to perform within 30 days of the index procedure, (or 6 months for drug eluting coronary stent or biventricular pacemaker implantation)*
  22. Hypersensitivity or contraindication to procedural medication and device materials (e.g. titanium, nickel, pork) which cannot be adequately pre-medicated
  23. Life expectancy < 1 year due to non-cardiac co-morbid conditions
  24. Currently participating in any investigational drug or device studies that may confound the results of this study
  25. History of any cognitive or mental health status that would interfere with study participation

"*"At the time of procedure, if a subject's medical status has changed since enrollment, the subject shall be re-evaluated for eligibility.

Sites / Locations

  • University of Leipzig - Heart Center

Arms of the Study

Arm 1

Arm Type

Experimental

Arm Label

HLT Transcatheter Aortic Valve System

Arm Description

Transcatheter aortic valve replacement with an HLT Transcatheter Aortic Valve System

Outcomes

Primary Outcome Measures

Primary Performance Endpoint 1: Procedural Device Performance
The primary performance endpoint is the Device Success defined as: Absence of procedural mortality AND Correct positioning of a single HLT Valve into the proper anatomical location AND Intended performance of the HLT Valve (no prosthesis- patient mismatch and mean aortic valve gradient < 20 mmHg or peak aortic valve velocity < 3 m/sec, AND no moderate or severe aortic valve regurgitation)
Primary Safety Endpoint 2: Mortality at 30 days
The primary safety endpoint is all-cause mortality at 30 days.

Secondary Outcome Measures

Secondary Performance Endpoint 1: Post-procedural Valve Performance
The HLT Valve performance will be evaluated by the following parameters with echocardiograms obtained at pre-discharge, 1, 6, 12, 24, 36, 48 and 60 months: Aortic valve effective orifice area (EOA) Severity of aortic valve regurgitation (AR) Aortic valve gradient
Secondary Safety Endpoint 2: Adverse Events
All adverse events will be assessed throughout the 5 year follow up period

Full Information

First Posted
June 2, 2014
Last Updated
April 28, 2021
Sponsor
HLT Inc.
search

1. Study Identification

Unique Protocol Identification Number
NCT02157142
Brief Title
HLT transfemOral Replacement of aortIc Valve Via transcatherteriZatiON
Acronym
HORIZON
Official Title
HLT transfemOral Replacement of aortIc Valve Via transcatherteriZatiON
Study Type
Interventional

2. Study Status

Record Verification Date
April 2021
Overall Recruitment Status
Completed
Study Start Date
August 2014 (Actual)
Primary Completion Date
December 2014 (Actual)
Study Completion Date
October 2019 (Actual)

3. Sponsor/Collaborators

Responsible Party, by Official Title
Sponsor
Name of the Sponsor
HLT Inc.

4. Oversight

Studies a U.S. FDA-regulated Drug Product
No
Studies a U.S. FDA-regulated Device Product
Yes
Device Product Not Approved or Cleared by U.S. FDA
Yes
Product Manufactured in and Exported from the U.S.
Yes
Data Monitoring Committee
Yes

5. Study Description

Brief Summary
The purpose of this study is to evaluate the safety and performance of the HLT System in patients with severe aortic stenosis who present at High Risk for aortic valve replacement surgery.

6. Conditions and Keywords

Primary Disease or Condition Being Studied in the Trial, or the Focus of the Study
Severe Aortic Stenosis, Aortic Valve Stenosis
Keywords
Severe aortic stenosis, Aortic valve stenosis, Transcatheter aortic valve replacement

7. Study Design

Primary Purpose
Treatment
Study Phase
Not Applicable
Interventional Study Model
Single Group Assignment
Masking
None (Open Label)
Allocation
N/A
Enrollment
4 (Actual)

8. Arms, Groups, and Interventions

Arm Title
HLT Transcatheter Aortic Valve System
Arm Type
Experimental
Arm Description
Transcatheter aortic valve replacement with an HLT Transcatheter Aortic Valve System
Intervention Type
Device
Intervention Name(s)
HLT Transcatheter Aortic Valve System
Intervention Description
Transcatheter aortic valve replacement with an HLT Transcatheter Aortic Valve System
Primary Outcome Measure Information:
Title
Primary Performance Endpoint 1: Procedural Device Performance
Description
The primary performance endpoint is the Device Success defined as: Absence of procedural mortality AND Correct positioning of a single HLT Valve into the proper anatomical location AND Intended performance of the HLT Valve (no prosthesis- patient mismatch and mean aortic valve gradient < 20 mmHg or peak aortic valve velocity < 3 m/sec, AND no moderate or severe aortic valve regurgitation)
Time Frame
Post procedure (day of procedure)
Title
Primary Safety Endpoint 2: Mortality at 30 days
Description
The primary safety endpoint is all-cause mortality at 30 days.
Time Frame
30 days
Secondary Outcome Measure Information:
Title
Secondary Performance Endpoint 1: Post-procedural Valve Performance
Description
The HLT Valve performance will be evaluated by the following parameters with echocardiograms obtained at pre-discharge, 1, 6, 12, 24, 36, 48 and 60 months: Aortic valve effective orifice area (EOA) Severity of aortic valve regurgitation (AR) Aortic valve gradient
Time Frame
pre-discharge (up to 14 days), 1, 6, 12, 24, 36, 48 and 60 months
Title
Secondary Safety Endpoint 2: Adverse Events
Description
All adverse events will be assessed throughout the 5 year follow up period
Time Frame
throughout the 5 year follow up period

10. Eligibility

Sex
All
Minimum Age & Unit of Time
75 Years
Accepts Healthy Volunteers
No
Eligibility Criteria
Inclusion Criteria: 75 years of age or older Echocardiographic or hemodynamic based evidence of calcific (senile) aortic stenosis with one of the following: aortic valve EOA <1.0 cm2 or 0.6 cm2/m2 , mean aortic valve gradient >40 mmHg or peak aortic valve velocity >4 m/sec Symptomatology due to aortic stenosis resulting in a New York Heart Association (NYHA) Functional Classification of II or greater Aortic valve annular diameter ≥ 21 and ≤23mm measured by MSCT An STS score ≥10; or Logistic EuroScore I ≥ 15; or a determination by one cardiovascular surgeon and one cardiologist that the co-morbidities not captured by the STS or EuroScore expected to increase the operative mortality risk to > 15%. Geographically available, willing to comply with follow up and able to provide written informed consent Exclusion Criteria: Congenital unicuspid or bicuspid aortic valve, or noncalcified aortic valve; or valve eccentricity (calcific or otherwise) that in the opinion of the investigator could compromise procedural success. Pre-existing prosthetic heart valve in any position, or prosthetic ring Severe (Grade 3 to 4) aortic, mitral or tricuspid valve regurgitation Moderate to severe mitral stenosis Myocardial infarction within the past 30 days* Echocardiographic evidence of intracardiac mass, thrombus or vegetation LVEF < 30% Uncontrolled hypertension (i.e. blood pressure at baseline > 140 mmHg systolic; or in the opinion of the investigator cannot be controlled by medical therapy). Severe pulmonary hypertension with pulmonary systolic pressure greater than two-thirds of systemic pressure Hemodynamic instability requiring inotropic drug therapy within the past 14 days or mechanical support within the past 6 months* Untreated clinically significant coronary artery disease requiring revascularization Presence of significant aortic disease such as atheroma, thrombus, or aneurysm which, in the opinion of the investigator, precludes safe implant delivery Blood dyscrasias defined as: acute leukopenia, acute anemia, acute thrombocytopenia, history of bleeding diathesis or coagulopathy Patient ineligible for or refuses blood transfusions Unfavorable peripheral vascular anatomy or disease (e.g. severe obstructive calcification, severe tortuosity or small vessels) that would preclude passage of catheters from the femoral arterial access to the aorta as evidenced by peripheral MSCT Active peptic ulcer or gastrointestinal bleeding within the past 90 days* Stroke or transient ischemic attack within past 6 months* Renal insufficiency as demonstrated by a serum creatinine > 2.5 mg/dL or end stage renal disease requiring chronic dialysis Active infection requiring ongoing treatment Need for emergent surgery or intervention other than the investigational procedure Any therapeutic invasive cardiac procedure performed or planned to perform within 30 days of the index procedure, (or 6 months for drug eluting coronary stent or biventricular pacemaker implantation)* Hypersensitivity or contraindication to procedural medication and device materials (e.g. titanium, nickel, pork) which cannot be adequately pre-medicated Life expectancy < 1 year due to non-cardiac co-morbid conditions Currently participating in any investigational drug or device studies that may confound the results of this study History of any cognitive or mental health status that would interfere with study participation "*"At the time of procedure, if a subject's medical status has changed since enrollment, the subject shall be re-evaluated for eligibility.
Overall Study Officials:
First Name & Middle Initial & Last Name & Degree
Axel Linke, MD
Organizational Affiliation
University of Leipzig - Herzzcntrum
Official's Role
Principal Investigator
Facility Information:
Facility Name
University of Leipzig - Heart Center
City
Leipzig
ZIP/Postal Code
04289
Country
Germany

12. IPD Sharing Statement

Learn more about this trial

HLT transfemOral Replacement of aortIc Valve Via transcatherteriZatiON

We'll reach out to this number within 24 hrs