HEAVy HAT-HEAlthy Volunteers Heart to Arm Time. Haemorrhage Simulation Protocol in Healthy Volunteers (HEAvyHAT)
Primary Purpose
Shock
Status
Completed
Phase
Not Applicable
Locations
Italy
Study Type
Interventional
Intervention
LBNP Lower Bodi Negative Pressure Chamber
Sponsored by

About this trial
This is an interventional basic science trial for Shock focused on measuring Hypovolaemic shock, Monitoring, Haemorrhage, Transthoracic Echocardiography
Eligibility Criteria
Inclusion Criteria:
- 30 healthy volunteers with no assumption of coffee or any other substance with possible action on the autonomic nervous system.
Exclusion Criteria:
- age < 18 yrs,
- pregnancy,
- assumption of any drugs and existence of any disease,
- intake of any drug/substance with action on the autonomic nervous system during the previous 24 hours.
Sites / Locations
- AO Ospedale Niguarda Ca' Granda
Arms of the Study
Arm 1
Arm Type
Experimental
Arm Label
Haemorrhage simulation
Arm Description
Outcomes
Primary Outcome Measures
iHAT validation as a bleeding predictor in a simulated and controlled haemorrhage model (Lower Body Negative Pressure chamber, LBNP)
Secondary Outcome Measures
Change from baseline in CO evaluated by Transthoracic echocardiography (TTE) during an haemorrhagic model
Full Information
NCT ID
NCT02177188
First Posted
March 1, 2013
Last Updated
June 26, 2014
Sponsor
University of Milano Bicocca
1. Study Identification
Unique Protocol Identification Number
NCT02177188
Brief Title
HEAVy HAT-HEAlthy Volunteers Heart to Arm Time. Haemorrhage Simulation Protocol in Healthy Volunteers
Acronym
HEAvyHAT
Official Title
HEAVy HAT-HEAlthy Volunteers Heart to Arm Time. Haemorrhage Simulation Protocol in Healthy Volunteers.
Study Type
Interventional
2. Study Status
Record Verification Date
June 2014
Overall Recruitment Status
Completed
Study Start Date
April 2012 (undefined)
Primary Completion Date
August 2012 (Actual)
Study Completion Date
September 2012 (Actual)
3. Sponsor/Collaborators
Responsible Party, by Official Title
Sponsor
Name of the Sponsor
University of Milano Bicocca
4. Oversight
Data Monitoring Committee
Yes
5. Study Description
Brief Summary
In prehospital settings, hypovolemic shock diagnosis is based on Advanced Trauma Life Support (ATLS) shock classification. The most often used clinical signs are heart rate (HR), arterial blood pressure (BP), respiratory rate, neurologic status, diuresis, skin colour and temperature. However, some of these signs, such as hypotension and tachycardia, lack specificity and sensitivity and do not occur early enough. Even with an early preload reduction, blood pressure can remain constant due to compensatory mechanisms, such as vasoconstriction and positive chronotropism. Tachycardia occurs earlier, but has poor specificity and sensitivity. A retrospective analysis of 25,287 trauma patients showed that among 489 patients presenting with systolic BP < 90 mmHg, only 65% had tachycardia (HR > 90 bpm), while 39% of patients with systolic BP > 120 mmHg were tachycardic, probably resulting from other stimuli influencing heart rate, such as pain, fear, circulating hormones and endogenous enkephalins. Therefore, it could be very useful to have an index that identifies initial volume variation, when physiological regulatory mechanisms are still effectively maintaining normal BP.
Pulse transit time (PTT) is the sum of pre-ejection period (PEP; the time interval between the onset of ventricular depolarization and ventricular ejection) and vascular transit time (VTT; the time it takes for the pulse wave to travel from the aortic valve to peripheral arteries). PEP and VTT variations depend on preload variation, and PTT increases with PEP, showing a linear correlation (R2 = 0.96). Chan et al. subjected 11 healthy volunteers to the head-up tilt test, and demonstrated that PEP increased and VTT decreased for increasing tilt angles from 0° to 80°, corresponding to light-moderate bleeding. They also observed early sympathetic activation, expressed by decreases of both RR interval (RR) and VTT, dampening the PTT increase, since PTT is influenced by both continuous PEP increase and progressive VTT decrease occurring during hypovolaemia.
Here the investigators describe a new index, called indexed Heart to Arm Time (iHAT). iHAT is the mPTT/RR ratio, where mPTT is a modified PTT, measured from the onset of ventricular depolarization (the 'R' wave of the ECG trace) to the systolic peak of the photoplethysmographic pulse oxymetry (PPG) waveform. mPTT is indexed to RR interval on ECG to counteract sympathetic activation that would dampen PEP increase and enhance VTT reduction, by means of positive inotropism and peripheral vasoconstriction, respectively. iHAT therefore increases during haemorrhage because of preload reduction and the consequent PEP increase and RR interval decrease. iHAT is expressed as the time percentage of the interbeat interval (RR) it takes to the PPG waveform to travel to peripheral arteries. In this study iHAT has been calculated as the average of beat-to-beat mPTT/RR ratios over 30 heart beats (corresponding to at least 2 breathing cycles) in order to minimize the effect of spontaneous breathing on preload, and thus on PEP and PTT.
In the present study, the investigators aimed to evaluate iHAT in a simulating model of hypovolaemia by using a Lower Body Negative Pressure (LBNP) chamber. LBNP chamber simulates haemorrhage by applying negative pressure to the lower limbs, thus giving an accurate model of hypovolemia. The LBNP chamber has been used for many years for research purposes, and in 2001 Convertino suggested it is a useful device to test severe haemorrhage-related hemodynamic responses. In fact, the induced volemic sequestration is an efficient technique to study physiological behaviours in humans.
The primary endpoint was to evaluate the use of the iHAT as a predictor of hypovolaemia. The secondary endpoint was to compare the specificity and sensitivity of the iHAT index compared to commonly used indexes (BP, HR). Furthermore, the investigators aimed to assess feasibility of Transthoracic echocardiography (TTE) evaluation of Cardiac Output (CO) in a haemorrhagic model and to evaluate CO changes with respect to measured hemodynamic variables.
TTE evaluation of CO is non invasive and comparable to thermodilution, and of possible use in an emergency setting.
6. Conditions and Keywords
Primary Disease or Condition Being Studied in the Trial, or the Focus of the Study
Shock
Keywords
Hypovolaemic shock, Monitoring, Haemorrhage, Transthoracic Echocardiography
7. Study Design
Primary Purpose
Basic Science
Study Phase
Not Applicable
Interventional Study Model
Single Group Assignment
Masking
None (Open Label)
Allocation
N/A
Enrollment
30 (Actual)
8. Arms, Groups, and Interventions
Arm Title
Haemorrhage simulation
Arm Type
Experimental
Intervention Type
Device
Intervention Name(s)
LBNP Lower Bodi Negative Pressure Chamber
Primary Outcome Measure Information:
Title
iHAT validation as a bleeding predictor in a simulated and controlled haemorrhage model (Lower Body Negative Pressure chamber, LBNP)
Time Frame
Progressive lower body negative pressure (LBNP) was applied in 5-min stages until the onset of impending cardiovascular collapse.
Secondary Outcome Measure Information:
Title
Change from baseline in CO evaluated by Transthoracic echocardiography (TTE) during an haemorrhagic model
Time Frame
Progressive lower body negative pressure (LBNP) was applied in 5-min stages until the onset of impending cardiovascular collapse.
10. Eligibility
Sex
All
Minimum Age & Unit of Time
18 Years
Accepts Healthy Volunteers
Accepts Healthy Volunteers
Eligibility Criteria
Inclusion Criteria:
30 healthy volunteers with no assumption of coffee or any other substance with possible action on the autonomic nervous system.
Exclusion Criteria:
age < 18 yrs,
pregnancy,
assumption of any drugs and existence of any disease,
intake of any drug/substance with action on the autonomic nervous system during the previous 24 hours.
Facility Information:
Facility Name
AO Ospedale Niguarda Ca' Granda
City
Milan
ZIP/Postal Code
20162
Country
Italy
12. IPD Sharing Statement
Citations:
PubMed Identifier
17701385
Citation
Chan GS, Middleton PM, Celler BG, Wang L, Lovell NH. Change in pulse transit time and pre-ejection period during head-up tilt-induced progressive central hypovolaemia. J Clin Monit Comput. 2007 Oct;21(5):283-93. doi: 10.1007/s10877-007-9086-8. Epub 2007 Aug 16.
Results Reference
background
PubMed Identifier
17327587
Citation
Esch BT, Scott JM, Warburton DE. Construction of a lower body negative pressure chamber. Adv Physiol Educ. 2007 Mar;31(1):76-81. doi: 10.1152/advan.00009.2006.
Results Reference
background
PubMed Identifier
12365445
Citation
Convertino VA. Lower body negative pressure as a tool for research in aerospace physiology and military medicine. J Gravit Physiol. 2001 Dec;8(2):1-14.
Results Reference
background
Learn more about this trial
HEAVy HAT-HEAlthy Volunteers Heart to Arm Time. Haemorrhage Simulation Protocol in Healthy Volunteers
We'll reach out to this number within 24 hrs