The Efficacy and Safety of Magnesium Alloy Screw as a Novel Bioabsorbable Material in Patients Due to Hand Fractures
Primary Purpose
Hand Fractures
Status
Completed
Phase
Phase 2
Locations
Study Type
Interventional
Intervention
K-MET™ Bioresorbable Bone screw
Sponsored by

About this trial
This is an interventional treatment trial for Hand Fractures
Eligibility Criteria
Inclusion Criteria:
- Male or female patients aged 20 years or older
- Patients who require internal fixation using screws in the hand
- The clinical features of hand fractures are oblique and spiral fractures
- Patients who voluntarily submitted a written informed consent and are willing to and able to follow the clinical study protocol.
Exclusion Criteria:
- Infections around the fracture site or soft-tissue injury greater than Grade III
- Fracture patterns such as open, transverse or comminuted fracture with greater than type II
- Fractures that require the use of wires, pins or plates for fixation
- Patients with re-fracture
- Patients with critical systemic diseases
- Patients with renal failure showing plasma creatinine level exceed 1.4 at the screening
- Pregnant, lactating women
- Patients who have a history of allergy to magnesium alloy
- Patients with presence of past illness or taking a drug that may affect bone union
- Patients who have participated in other clinical study and treated with medication or other medical device within past 3 months
- Patients who are judged not to be appropriate for study enrollment in the opinion of the investigator
Sites / Locations
Arms of the Study
Arm 1
Arm Type
Experimental
Arm Label
K-MET™ Bioresorbable Bone screw
Arm Description
The K-MET™ Bioresorbable Bone Screw, intended to be used for trauma therapy, consists of Cortex screws, Cannulated headless screws. For Headless screw and Cannulated headless screws, the design is similar to normal headless compression screws but the compression function was achieved by using different lengths for the front and rear pitches. These screws are dynamic and allow therewith the fracture at the Carpal, metacarpal, and small hand bone.
Outcomes
Primary Outcome Measures
Bone union
Bone union was evaluated at 6-month after surgery according to the following definition.Definition of bone union is when simple X-ray findings reveal that bone trabeculae or cortical bone exceeds the fracture site. Non-union is defined as no union at 3-month post-surgery.
Secondary Outcome Measures
PROM(Passive Range of Motion)
This Passive Range of Motion(PROM) is measured by goniometer and is compared with the value of the normal hand that did not undergo surgery.
TAM(Total Active Motion)
Total Active Motion(TAM) is measured by goniometer and is compared with the value of the normal hand that did not undergo surgery.
Power(grip strength and pick-up power)
The Power was measured using a dynamometer and pick-up counter and is compared with the value of the hand that did not undergo surgery.
DASH scale
This questionnaire evaluates the ability of the hand to perform certain activities before and after surgery. It was directly completed by subjects.
Pain as measured by the NRS (1~10)
The NRS (1~10) was used to measure the level of pain and was compared before and after surgery.
Full Information
1. Study Identification
Unique Protocol Identification Number
NCT02456415
Brief Title
The Efficacy and Safety of Magnesium Alloy Screw as a Novel Bioabsorbable Material in Patients Due to Hand Fractures
Official Title
A Prospective, Single Center, Single Group, Open-label Study to Evaluate the Efficacy and Safety of Magnesium Alloy Screw as a Novel Bioabsorbable Material in Patients Requiring Internal Fixation Due to Hand Fractures
Study Type
Interventional
2. Study Status
Record Verification Date
May 2015
Overall Recruitment Status
Completed
Study Start Date
July 2013 (undefined)
Primary Completion Date
November 2014 (Actual)
Study Completion Date
December 2014 (Actual)
3. Sponsor/Collaborators
Responsible Party, by Official Title
Sponsor
Name of the Sponsor
U&I Corporation
4. Oversight
Data Monitoring Committee
Yes
5. Study Description
Brief Summary
This study evaluates the safety and efficacy of biodegradable magnesium alloy screw, in patients with hand fractures who require internal fixation (to obtain a product license from the Ministry of Food and Drug Safety in Korea (MFDS)).
Detailed Description
Rationale: Hand fractures including intra- and extra-articular phalanges and metacarpal are common and account for approximately 40% of upper extremity fractures and lead to functional loss of the hand.Fractures can be treated conservatively with a nonsurgical approach(Closed reduction) by placing the damaged figure in a splint; this may results in displacement, rotation, angulation and/or instability, therefore require surgery. Surgical techniques for treatment of hand fractures include internal fixation with metal plate or screws after Open reduction and external fixation with insertion of percutaneous pins or screws. Percutaneous external fixation is one of the widely used methods, but is difficult to maintained when accompanied by unstable fractures and soft tissue injuries or there are severely comminuted fractures and sometimes results in restricted motion of adjacent joints due to prolonged fixation. In comparison, internal fixation is an operation using internal fixators such as plates, wires, screws etc. solely or concurrently depending on the location and severity of hand fracture. With the recent advancement of implant design and fixation techniques, a variety of screws are widely used for fixation of small-bone fractures.
The present study was designed to evaluate the efficacy and safety of magnesium alloy screw as a novel bioabsorbable and biodegradable material.
Study Duration: After an approval of clinical protocol from MFDS in Korea, total 20 months were required including 14 months for subject enrollment and 6 months of follow-up. An additional 1 month was required after completion of the study for handling of data, statistical analysis and preparation of study report.
Target Subjects: Patients who require internal fixation using screws due to hand fractures
Investigational Device: K-MET™ Bioresorbable Bone screw (manufactured by U&I) This device divided into two type,Cortex screw and Headless compression screw.
Number of Subjects: A total of 34 cases of bone fractures in 28 subjects.
6. Conditions and Keywords
Primary Disease or Condition Being Studied in the Trial, or the Focus of the Study
Hand Fractures
7. Study Design
Primary Purpose
Treatment
Study Phase
Phase 2
Interventional Study Model
Single Group Assignment
Masking
None (Open Label)
Allocation
N/A
Enrollment
28 (Actual)
8. Arms, Groups, and Interventions
Arm Title
K-MET™ Bioresorbable Bone screw
Arm Type
Experimental
Arm Description
The K-MET™ Bioresorbable Bone Screw, intended to be used for trauma therapy, consists of Cortex screws, Cannulated headless screws. For Headless screw and Cannulated headless screws, the design is similar to normal headless compression screws but the compression function was achieved by using different lengths for the front and rear pitches. These screws are dynamic and allow therewith the fracture at the Carpal, metacarpal, and small hand bone.
Intervention Type
Device
Intervention Name(s)
K-MET™ Bioresorbable Bone screw
Intervention Description
The biodegradable screw inserted into bone with an appropriate driver is slowly degraded and is completely degraded after completion of bone union and absorbed into the body. The screw is indicated for fixing damaged bone.
Primary Outcome Measure Information:
Title
Bone union
Description
Bone union was evaluated at 6-month after surgery according to the following definition.Definition of bone union is when simple X-ray findings reveal that bone trabeculae or cortical bone exceeds the fracture site. Non-union is defined as no union at 3-month post-surgery.
Time Frame
up to 6 months
Secondary Outcome Measure Information:
Title
PROM(Passive Range of Motion)
Description
This Passive Range of Motion(PROM) is measured by goniometer and is compared with the value of the normal hand that did not undergo surgery.
Time Frame
up to 6 months
Title
TAM(Total Active Motion)
Description
Total Active Motion(TAM) is measured by goniometer and is compared with the value of the normal hand that did not undergo surgery.
Time Frame
up to 6 months
Title
Power(grip strength and pick-up power)
Description
The Power was measured using a dynamometer and pick-up counter and is compared with the value of the hand that did not undergo surgery.
Time Frame
up to 6 months
Title
DASH scale
Description
This questionnaire evaluates the ability of the hand to perform certain activities before and after surgery. It was directly completed by subjects.
Time Frame
3,6 months
Title
Pain as measured by the NRS (1~10)
Description
The NRS (1~10) was used to measure the level of pain and was compared before and after surgery.
Time Frame
up to 6 months
10. Eligibility
Sex
All
Minimum Age & Unit of Time
20 Years
Accepts Healthy Volunteers
Accepts Healthy Volunteers
Eligibility Criteria
Inclusion Criteria:
Male or female patients aged 20 years or older
Patients who require internal fixation using screws in the hand
The clinical features of hand fractures are oblique and spiral fractures
Patients who voluntarily submitted a written informed consent and are willing to and able to follow the clinical study protocol.
Exclusion Criteria:
Infections around the fracture site or soft-tissue injury greater than Grade III
Fracture patterns such as open, transverse or comminuted fracture with greater than type II
Fractures that require the use of wires, pins or plates for fixation
Patients with re-fracture
Patients with critical systemic diseases
Patients with renal failure showing plasma creatinine level exceed 1.4 at the screening
Pregnant, lactating women
Patients who have a history of allergy to magnesium alloy
Patients with presence of past illness or taking a drug that may affect bone union
Patients who have participated in other clinical study and treated with medication or other medical device within past 3 months
Patients who are judged not to be appropriate for study enrollment in the opinion of the investigator
Overall Study Officials:
First Name & Middle Initial & Last Name & Degree
Gyeong-jin Han, professor
Organizational Affiliation
Ajou Univ hospital
Official's Role
Principal Investigator
12. IPD Sharing Statement
Learn more about this trial
The Efficacy and Safety of Magnesium Alloy Screw as a Novel Bioabsorbable Material in Patients Due to Hand Fractures
We'll reach out to this number within 24 hrs