search
Back to results

Head to Head Comparison of Two Needles EUS Guided FNB

Primary Purpose

Pancreatic Tumor

Status
Withdrawn
Phase
Not Applicable
Locations
United States
Study Type
Interventional
Intervention
Ultrasound biopsy needle Echo Tip ProCore
Ultrasound biopsy needle SharkCore
Sponsored by
Milton S. Hershey Medical Center
About
Eligibility
Locations
Arms
Outcomes
Full info

About this trial

This is an interventional diagnostic trial for Pancreatic Tumor focused on measuring Core tissue biopsy, Core needle biopsy, EUS, Fine needle biopsy, Fine needle aspiration

Eligibility Criteria

18 Years - 89 Years (Adult, Older Adult)All SexesDoes not accept healthy volunteers

Inclusion Criteria:

  • Adult subjects aged 18-90 of any gender, ethnicity and race that are referred to endoscopy for endoscopic ultrasound guided tissue acquisition for solid pancreatic mass.
  • Voluntary enrollment
  • Ability to give written informed consent
  • Subjects must have a pancreatic mass detected by radiology (CT or MRI) or ultrasound or at the time of EUS.

Exclusion Criteria:

  • Patients with coagulopathy with an elevated INR>2
  • Any individual who cannot provide one's voluntary informed written consent.
  • Any pre-existing or discovered medical condition that may at the discretion of investigator interfere with the completion of and/ or participation in existing protocol.
  • Pregnancy
  • Less than 18 years old

Sites / Locations

  • Penn State Milton S. Hershey Medical Center

Arms of the Study

Arm 1

Arm 2

Arm Type

Experimental

Experimental

Arm Label

Pro Core EUS guided Fine Needle Biopsy

Shark Core EUS guided Fine Needle Biopsy

Arm Description

Echo Tip ProCore ultrasound biopsy needle (Cook Medical 25 gauge) with reverse bevel design for diagnosis of pancreatic lesions.

SharkCore ultrasound biopsy needle (Medtronic [Beacon] 25 gauge) with six cutting edge surfaces and an opposing bevel design for diagnosis of pancreatic lesions.

Outcomes

Primary Outcome Measures

Direct Comparison of pancreatic mass histologic tissue adequacy using two EUS guided fine needle biopsy needles
Head to head comparison of tissue adequacy for solid pancreatic lesions using two 25 gauge EUS guided fine needle biopsy platforms - ProCore vs SharkCore.

Secondary Outcome Measures

Full Information

First Posted
August 13, 2015
Last Updated
September 12, 2016
Sponsor
Milton S. Hershey Medical Center
search

1. Study Identification

Unique Protocol Identification Number
NCT02534246
Brief Title
Head to Head Comparison of Two Needles EUS Guided FNB
Official Title
A Paired Prospective, Single Blinded Study of the Diagnostic Accuracy and Specimen Adequacy of Two Endoscopic Tissue Biopsy Needles for Diagnosis Solid Pancreatic Mass
Study Type
Interventional

2. Study Status

Record Verification Date
September 2016
Overall Recruitment Status
Withdrawn
Study Start Date
August 2016 (undefined)
Primary Completion Date
October 2016 (Anticipated)
Study Completion Date
October 2017 (Anticipated)

3. Sponsor/Collaborators

Responsible Party, by Official Title
Principal Investigator
Name of the Sponsor
Milton S. Hershey Medical Center

4. Oversight

Data Monitoring Committee
Yes

5. Study Description

Brief Summary
The aim of this study is to evaluate and compare the diagnostic accuracy and specimen adequacy of two ultrasound biopsy needles. These are two existing FDA approved tissue biopsy regimens, with respect to diagnosis of solid pancreatic lesions.
Detailed Description
EUS guided core biopsy using various needle designs and sizes, seems to be a promising technique to procure tissue in solid pancreatic masses for making an accurate histological diagnosis. EUS-guided core biopsies of pancreas may aid in patients with non-diagnostic EUS-FNA samples and institutions where they do not have on-site cytopathology available for prompt evaluation of tissue adequacy. Making an accurate diagnosis not only assists in planning appropriate treatment but also may decrease morbidity/mortality from unnecessary surgeries. Our goal is to evaluate and compare the diagnostic accuracy and specimen adequacy of the Cook Medical 25 gauge ProCore ultrasound biopsy needle and the Medtronic (Beacon) 25 gauge SharkCore ultrasound biopsy needle. We hypothesize the endoscopic ultrasound tissue biopsy will not be different in diagnostic accuracy of solid pancreatic lesions when using a 25 gauge SharkCore ultrasound biopsy needle in comparison with the 25 gauge ProCore ultrasound biopsy needle. This is a non- inferior paired, prospective, single-blind study design in which patients undergoing EUS for a solid pancreatic mass. Two biopsies with each of the two endoscopic needles of interest in this study will be used in random order. The biopsy needle passed first will be randomized, after which the two needles will be alternated for each of the remaining biopsies. Randomization will occur in permuted blocks of 3. Physician will record the ease/ difficulty of obtaining each of the 4 biopsies on a scale of 1 to 5. Also, they record the needle visibility on ultrasound. The biopsy site will be examined for evidence of bleeding. Biopsies will be sent to the pathology laboratory in a blinded fashion in coded containers, where pathologist determine the number of adequate biopsies out of two passes of each needle.The pathologist will also provide a scale of perceived diagnostic usefulness of material in a blinded fashion. Post procedure care will including a letter to referring physician with recommendations for treatment and follow up. This study include 30 patients referred to Hershey Medical Center.

6. Conditions and Keywords

Primary Disease or Condition Being Studied in the Trial, or the Focus of the Study
Pancreatic Tumor
Keywords
Core tissue biopsy, Core needle biopsy, EUS, Fine needle biopsy, Fine needle aspiration

7. Study Design

Primary Purpose
Diagnostic
Study Phase
Not Applicable
Interventional Study Model
Crossover Assignment
Masking
Care Provider
Allocation
Randomized
Enrollment
0 (Actual)

8. Arms, Groups, and Interventions

Arm Title
Pro Core EUS guided Fine Needle Biopsy
Arm Type
Experimental
Arm Description
Echo Tip ProCore ultrasound biopsy needle (Cook Medical 25 gauge) with reverse bevel design for diagnosis of pancreatic lesions.
Arm Title
Shark Core EUS guided Fine Needle Biopsy
Arm Type
Experimental
Arm Description
SharkCore ultrasound biopsy needle (Medtronic [Beacon] 25 gauge) with six cutting edge surfaces and an opposing bevel design for diagnosis of pancreatic lesions.
Intervention Type
Device
Intervention Name(s)
Ultrasound biopsy needle Echo Tip ProCore
Intervention Description
Two passes preformed with Echo Tip ProCore ultrasound biopsy needle (Cook Medical 25 gauge) and two passes will be performed using SharkCore ultrasound biopsy needle (Medtronic [Beacon] 25 gauge) from single lesion.
Intervention Type
Device
Intervention Name(s)
Ultrasound biopsy needle SharkCore
Primary Outcome Measure Information:
Title
Direct Comparison of pancreatic mass histologic tissue adequacy using two EUS guided fine needle biopsy needles
Description
Head to head comparison of tissue adequacy for solid pancreatic lesions using two 25 gauge EUS guided fine needle biopsy platforms - ProCore vs SharkCore.
Time Frame
1year

10. Eligibility

Sex
All
Minimum Age & Unit of Time
18 Years
Maximum Age & Unit of Time
89 Years
Accepts Healthy Volunteers
No
Eligibility Criteria
Inclusion Criteria: Adult subjects aged 18-90 of any gender, ethnicity and race that are referred to endoscopy for endoscopic ultrasound guided tissue acquisition for solid pancreatic mass. Voluntary enrollment Ability to give written informed consent Subjects must have a pancreatic mass detected by radiology (CT or MRI) or ultrasound or at the time of EUS. Exclusion Criteria: Patients with coagulopathy with an elevated INR>2 Any individual who cannot provide one's voluntary informed written consent. Any pre-existing or discovered medical condition that may at the discretion of investigator interfere with the completion of and/ or participation in existing protocol. Pregnancy Less than 18 years old
Overall Study Officials:
First Name & Middle Initial & Last Name & Degree
John M Levenick, MD
Organizational Affiliation
Milton S. Hershey Medical Center
Official's Role
Principal Investigator
Facility Information:
Facility Name
Penn State Milton S. Hershey Medical Center
City
Hershey
State/Province
Pennsylvania
ZIP/Postal Code
17033
Country
United States

12. IPD Sharing Statement

Learn more about this trial

Head to Head Comparison of Two Needles EUS Guided FNB

We'll reach out to this number within 24 hrs