His Bundle Pacing Versus Coronary Sinus Pacing for Cardiac Resynchronization Therapy (His-SYNC)

Primary Purpose

Congestive Heart Failure

Status
Completed
Phase
Not Applicable
Locations
United States
Study Type
Interventional
Intervention
CRT Pacemaker
Sponsored by
University of Chicago
About
Eligibility
Locations
Arms
Outcomes
Full info

About this trial

This is an interventional treatment trial for Congestive Heart Failure focused on measuring Wide QRS, Ventricular Dyssynchrony

Eligibility Criteria

18 Years - undefined (Adult, Older Adult)All SexesDoes not accept healthy volunteers

Inclusion Criteria:

  • Patients at least 18 years of age
  • LV systolic dysfunction with LVEF ≤ 35%
  • Evidence of intraventricular conduction delay with QRS duration > 120 msec
  • NYHA Class II, III, and ambulatory Class IV heart failure with either ischemic or nonischemic cardiomyopathy and patients with NYHA Class I symptoms and ischemic cardiomyopathy
  • Left ventricular ejection fraction (LVEF) ≤ 35%, sinus rhythm (SR), left bundle-branch block (LBBB) morphology, and QRS duration ≥ 150 msec, and NYHA Class II, III, or ambulatory Class IV patients on goal-directed medical therapy (GDMT) [Class I]
  • LVEF ≤ 35%, SR with LBBB with QRS 120-149 msec on GDMT [Class IIa]
  • LVEF ≤ 35%, SR with non-LBBB with QRS ≥ 150 msec on GDMT [Class IIa]
  • LVEF ≤ 35%, in AF if medication or AV nodal ablation will allow near 100% pacing [Class IIa]
  • LVEF ≤ 35% undergoing new or replacement device with anticipated >40% ventricular pacing on GDMT [Class IIa]
  • LVEF ≤ 30%, ischemic etiology of HF, SR with LBBB ≥ 150 msec and NYHA Class I symptoms on GDMT [Class IIb]
  • LVEF ≤ 35%, SR with non-LBBB with QRS 120-149 msec, NYHA Class III/ambulatory Class IV HF on GDMT [Class IIb] LVEF ≤ 35%, SR with non-LBBB with QRS ≥ 150 msec, NYHA Class II HF on GDMT [Class IIb]

Exclusion Criteria:

  • Existing CRT device
  • Inability of patient capacity to provide consent for themselves either due to medical or psychiatric comorbidity
  • Pregnancy
  • Participation in other trials
  • Difficulty with follow-up

Sites / Locations

  • The University of California, Los Angeles
  • Northwestern University
  • Rush University Medical Center
  • The University of Chicago
  • Edward Hospital
  • Indiana University
  • Baptist Health Louisville
  • Geisinger Wyoming Valley Medical Center

Arms of the Study

Arm 1

Arm 2

Arm Type

Active Comparator

Active Comparator

Arm Label

His Bundle Pacing

Coronary Sinus Pacing

Arm Description

Subjects will be randomized to the HB lead position with their cardiac resynchronization therapy (CRT) pacemaker. HB lead pacing will be performed with the Medtronic SelectSecure™, Model 3830 lead. Delivery of the lead utilizes a deflectable sheath, the Medtronic SelectSite™, Model C304. Both devices are FDA approved for the purpose of HB pacing. It is the only device available which is presently FDA approved for selective HB pacing.

Subjects will be randomized to the CS lead position with their cardiac resynchronization therapy (CRT) pacemaker. CS lead and CRT device generator selected for implant will be left to the discretion of the operator. Only FDA approved CS leads and CRT generators will be utilized in the study. There are five present manufacturers of CS leads and CRT generators: Biotronik, Boston Scientific, Medtronic, Sorin, and St. Jude Medical.

Outcomes

Primary Outcome Measures

Change in Left Ventricular Ejection Fraction (LVEF)
Change in left ventricular ejection fraction (LVEF) as measured by echocardiography in a blinded core lab.
Change in QRS Duration
Change in QRS duration as measured by electrocardiography
Time to First Cardiovascular Hospitalization or Death
Time to first cardiovascular hospitalization or death in months

Secondary Outcome Measures

New York Heart Association (NYHA) Functional Class Change
New York Heart Association (NYHA) functional class change for baseline, 6 months, and 12 months. NYHA class determines the functional status of the patient. There are classes I-IV. Class I is no symptoms or limitation of physical activity, II is slight limitation of physical activity but comfortable at rest, III marked limitation of physical activity, and IV is unable to carry any physical activity without discomfort, heart failure symptoms at rest, and discomfort increases with any physical activity as described the American Heart Association (AHA).
Quality of Life Change by Kansas City Questionnaire (KCCQ)
Quality of life change as measured by Kansas City Questionnaire (KCCQ) is a 23-item instrument that is self-administered. KCCQ measures physical function, symptoms (specifically frequency, severity, and recent change), social function, self-efficacy and knowledge, and quality of life. Subscales and Total Score range from minimum of 0-100 (maximum); higher scores show better health status. Developed and validated by Dr. John Spertus,MD of University of Missouri-Kansas City.
Time to First Cardiovascular Rehospitalization
Time to first cardiovascular rehospitalization in 12 months
Time to First Treated Ventricular Arrhythmia/Ventricular Tachycardia (VT/VF)
Time to first treated ventricular arrhythmia/ventricular tachycardia (VT/VF) in 12 months

Full Information

First Posted
January 29, 2016
Last Updated
August 10, 2021
Sponsor
University of Chicago
Collaborators
University of California, Los Angeles, Northwestern University, Rush University Medical Center, Geisinger Clinic, Indiana University, Edward Hospital, Baptist Health, Louisville
search

1. Study Identification

Unique Protocol Identification Number
NCT02700425
Brief Title
His Bundle Pacing Versus Coronary Sinus Pacing for Cardiac Resynchronization Therapy
Acronym
His-SYNC
Official Title
His Bundle Pacing Versus Coronary Sinus Pacing for Cardiac Resynchronization Therapy
Study Type
Interventional

2. Study Status

Record Verification Date
July 2021
Overall Recruitment Status
Completed
Study Start Date
May 17, 2016 (Actual)
Primary Completion Date
July 31, 2020 (Actual)
Study Completion Date
July 31, 2020 (Actual)

3. Sponsor/Collaborators

Responsible Party, by Official Title
Sponsor
Name of the Sponsor
University of Chicago
Collaborators
University of California, Los Angeles, Northwestern University, Rush University Medical Center, Geisinger Clinic, Indiana University, Edward Hospital, Baptist Health, Louisville

4. Oversight

Studies a U.S. FDA-regulated Drug Product
No
Studies a U.S. FDA-regulated Device Product
Yes
Data Monitoring Committee
No

5. Study Description

Brief Summary
The goal of this study is to compare the effectiveness of pacing from a physiologic His bundle (HB) lead position versus with the standard coronary sinus (CS) lead position in subjects with heart failure undergoing cardiac resynchronization therapy (CRT). While placement of left ventricular leads via the coronary sinus has anatomic limitations, we hypothesis that the achievement of QRS narrowing with His bundle capture will be superior for improving systolic function by echocardiographic indices (ejection fraction and strain) and quality of life and decreased rehospitalization and mortality.
Detailed Description
This is a randomized, single-blinded study of 40 patients to a strategy of HB pacing versus CS pacing, and remain blinded to their treatment allocation. Both treatment options use standard-of-care, FDA-approved devices. The distinction is only in the allocation toward HB pacing and CS pacing. Treating physicians will be aware of assignment in order to facilitate routine device follow-up. Echocardiographic and electrocardiographic evaluation will also be performed in a blinded manner. Cross-over is permitted between treatment group allocation if: CS lead cannot be placed due to difficult cannulation of the CS, limited branches at the posterolateral or lateral wall, or phrenic nerve capture. These subjects may then cross-over to HB pacing. HB pacing subjects may cross-over if HB lead cannot be positioned with adequate stability and reasonable pacing output, or if QRS width does not narrow by at least 20% or to a QRS width of ≤ 130 msec. Implant procedure will be per routine percutaneous access, as is standard for pacemaker and ICDs. All subjects will receive an FDA-approved cardiac resynchronization therapy pacemaker or defibrillator device, as per standard of care outlined for the subject. In order to facilitate optimal lead placement, arterial access for levo-phase CS angiography and/or LV septal mapping to characterize site of bundle-branch block may also be performed, at the discretion of the implanting physician per his/her standard practice. Follow-up will be performed at 2 weeks post-implant for incision check and device interrogation as is standard of care. In addition, routine device and clinical follow-up will be scheduled at 1, 3, 6, and 12 months. Electrocardiography (ECG) will be performed pre-implant, prior to hospital discharge, at 3 months, 6 months, and 12 months. Echocardiography will be performed pre-implant and 6 months to evaluate for change in LVEF, chamber dimension, and wall motion with strain imaging as is standard of care in the treatment of patients with advanced heart failure. NYHA functional class and quality of life (utilizing the Kansas City Cardiomyopathy Questionnaire) will be assessed pre-implant and at 6 months.

6. Conditions and Keywords

Primary Disease or Condition Being Studied in the Trial, or the Focus of the Study
Congestive Heart Failure
Keywords
Wide QRS, Ventricular Dyssynchrony

7. Study Design

Primary Purpose
Treatment
Study Phase
Not Applicable
Interventional Study Model
Parallel Assignment
Masking
Participant
Allocation
Randomized
Enrollment
41 (Actual)

8. Arms, Groups, and Interventions

Arm Title
His Bundle Pacing
Arm Type
Active Comparator
Arm Description
Subjects will be randomized to the HB lead position with their cardiac resynchronization therapy (CRT) pacemaker. HB lead pacing will be performed with the Medtronic SelectSecure™, Model 3830 lead. Delivery of the lead utilizes a deflectable sheath, the Medtronic SelectSite™, Model C304. Both devices are FDA approved for the purpose of HB pacing. It is the only device available which is presently FDA approved for selective HB pacing.
Arm Title
Coronary Sinus Pacing
Arm Type
Active Comparator
Arm Description
Subjects will be randomized to the CS lead position with their cardiac resynchronization therapy (CRT) pacemaker. CS lead and CRT device generator selected for implant will be left to the discretion of the operator. Only FDA approved CS leads and CRT generators will be utilized in the study. There are five present manufacturers of CS leads and CRT generators: Biotronik, Boston Scientific, Medtronic, Sorin, and St. Jude Medical.
Intervention Type
Device
Intervention Name(s)
CRT Pacemaker
Intervention Description
Cardiac Resynchronization Therapy (CRT) is the use of a pacemaker with two endocardial leads placed in the right atrium (RA) and right ventricle (RV). The third lead is traditionally placed in a tributary of the coronary sinus (CS) overlying the epicardial surface of the left ventricle (LV). Alternatively, the third lead may be positioned based on mapping of the common His bundle and actively fixed to achieve QRS normalization via direct His bundle capture.
Primary Outcome Measure Information:
Title
Change in Left Ventricular Ejection Fraction (LVEF)
Description
Change in left ventricular ejection fraction (LVEF) as measured by echocardiography in a blinded core lab.
Time Frame
baseline and 6 months
Title
Change in QRS Duration
Description
Change in QRS duration as measured by electrocardiography
Time Frame
baseline and 12 months
Title
Time to First Cardiovascular Hospitalization or Death
Description
Time to first cardiovascular hospitalization or death in months
Time Frame
Through study completion, an average of 12 months.
Secondary Outcome Measure Information:
Title
New York Heart Association (NYHA) Functional Class Change
Description
New York Heart Association (NYHA) functional class change for baseline, 6 months, and 12 months. NYHA class determines the functional status of the patient. There are classes I-IV. Class I is no symptoms or limitation of physical activity, II is slight limitation of physical activity but comfortable at rest, III marked limitation of physical activity, and IV is unable to carry any physical activity without discomfort, heart failure symptoms at rest, and discomfort increases with any physical activity as described the American Heart Association (AHA).
Time Frame
baseline, 6 months, and 12 months
Title
Quality of Life Change by Kansas City Questionnaire (KCCQ)
Description
Quality of life change as measured by Kansas City Questionnaire (KCCQ) is a 23-item instrument that is self-administered. KCCQ measures physical function, symptoms (specifically frequency, severity, and recent change), social function, self-efficacy and knowledge, and quality of life. Subscales and Total Score range from minimum of 0-100 (maximum); higher scores show better health status. Developed and validated by Dr. John Spertus,MD of University of Missouri-Kansas City.
Time Frame
baseline and 12 months
Title
Time to First Cardiovascular Rehospitalization
Description
Time to first cardiovascular rehospitalization in 12 months
Time Frame
Through study completion, an average of 12 months
Title
Time to First Treated Ventricular Arrhythmia/Ventricular Tachycardia (VT/VF)
Description
Time to first treated ventricular arrhythmia/ventricular tachycardia (VT/VF) in 12 months
Time Frame
Through study completion, an average of 12 months

10. Eligibility

Sex
All
Minimum Age & Unit of Time
18 Years
Accepts Healthy Volunteers
No
Eligibility Criteria
Inclusion Criteria: Patients at least 18 years of age LV systolic dysfunction with LVEF ≤ 35% Evidence of intraventricular conduction delay with QRS duration > 120 msec NYHA Class II, III, and ambulatory Class IV heart failure with either ischemic or nonischemic cardiomyopathy and patients with NYHA Class I symptoms and ischemic cardiomyopathy Left ventricular ejection fraction (LVEF) ≤ 35%, sinus rhythm (SR), left bundle-branch block (LBBB) morphology, and QRS duration ≥ 150 msec, and NYHA Class II, III, or ambulatory Class IV patients on goal-directed medical therapy (GDMT) [Class I] LVEF ≤ 35%, SR with LBBB with QRS 120-149 msec on GDMT [Class IIa] LVEF ≤ 35%, SR with non-LBBB with QRS ≥ 150 msec on GDMT [Class IIa] LVEF ≤ 35%, in AF if medication or AV nodal ablation will allow near 100% pacing [Class IIa] LVEF ≤ 35% undergoing new or replacement device with anticipated >40% ventricular pacing on GDMT [Class IIa] LVEF ≤ 30%, ischemic etiology of HF, SR with LBBB ≥ 150 msec and NYHA Class I symptoms on GDMT [Class IIb] LVEF ≤ 35%, SR with non-LBBB with QRS 120-149 msec, NYHA Class III/ambulatory Class IV HF on GDMT [Class IIb] LVEF ≤ 35%, SR with non-LBBB with QRS ≥ 150 msec, NYHA Class II HF on GDMT [Class IIb] Exclusion Criteria: Existing CRT device Inability of patient capacity to provide consent for themselves either due to medical or psychiatric comorbidity Pregnancy Participation in other trials Difficulty with follow-up
Overall Study Officials:
First Name & Middle Initial & Last Name & Degree
Roderick Tung, MD
Organizational Affiliation
University of Chicago
Official's Role
Principal Investigator
First Name & Middle Initial & Last Name & Degree
Gaurav A. Upadhyay, MD
Organizational Affiliation
University of Chicago
Official's Role
Principal Investigator
Facility Information:
Facility Name
The University of California, Los Angeles
City
Los Angeles
State/Province
California
ZIP/Postal Code
90095
Country
United States
Facility Name
Northwestern University
City
Chicago
State/Province
Illinois
ZIP/Postal Code
60611
Country
United States
Facility Name
Rush University Medical Center
City
Chicago
State/Province
Illinois
ZIP/Postal Code
60612
Country
United States
Facility Name
The University of Chicago
City
Chicago
State/Province
Illinois
ZIP/Postal Code
60637
Country
United States
Facility Name
Edward Hospital
City
Naperville
State/Province
Illinois
ZIP/Postal Code
60540
Country
United States
Facility Name
Indiana University
City
Indianapolis
State/Province
Indiana
ZIP/Postal Code
46202
Country
United States
Facility Name
Baptist Health Louisville
City
Louisville
State/Province
Kentucky
ZIP/Postal Code
40207
Country
United States
Facility Name
Geisinger Wyoming Valley Medical Center
City
Wilkes-Barre
State/Province
Pennsylvania
ZIP/Postal Code
18711
Country
United States

12. IPD Sharing Statement

Plan to Share IPD
No
Citations:
PubMed Identifier
31078637
Citation
Upadhyay GA, Vijayaraman P, Nayak HM, Verma N, Dandamudi G, Sharma PS, Saleem M, Mandrola J, Genovese D, Tung R; His-SYNC Investigators. His Corrective Pacing or Biventricular Pacing for Cardiac Resynchronization in Heart Failure. J Am Coll Cardiol. 2019 Jul 9;74(1):157-159. doi: 10.1016/j.jacc.2019.04.026. Epub 2019 May 9. No abstract available.
Results Reference
result
PubMed Identifier
31096064
Citation
Upadhyay GA, Vijayaraman P, Nayak HM, Verma N, Dandamudi G, Sharma PS, Saleem M, Mandrola J, Genovese D, Oren JW, Subzposh FA, Aziz Z, Beaser A, Shatz D, Besser S, Lang RM, Trohman RG, Knight BP, Tung R; His-SYNC Investigators. On-treatment comparison between corrective His bundle pacing and biventricular pacing for cardiac resynchronization: A secondary analysis of the His-SYNC Pilot Trial. Heart Rhythm. 2019 Dec;16(12):1797-1807. doi: 10.1016/j.hrthm.2019.05.009. Epub 2019 May 13.
Results Reference
result

Learn more about this trial

His Bundle Pacing Versus Coronary Sinus Pacing for Cardiac Resynchronization Therapy

We'll reach out to this number within 24 hrs