At Home Study of a Zone-Model Predictive Control (MPC) Controller and a Health Monitoring System (HMS) With the Diabetes Assistant (DiAs) System and Run-to-Run Adaptation
Type 1 Diabetes Mellitus
About this trial
This is an interventional treatment trial for Type 1 Diabetes Mellitus focused on measuring Diabetes Mellitus, Type 1, Artificial Pancreas, Autoimmune Diseases, Diabetes Mellitus, Hyperglycemia, Hypoglycemia
Eligibility Criteria
Inclusion Criteria:
- Clinical diagnosis, based on investigator assessment, of type 1 diabetes for at least one year and using insulin for at least 1 year and an insulin pump for at least 6 months
- Willing to wear the study CGM device for the duration of the study
- Age ≥21 to <65 years
- HbA1c <10.0%; if HbA1c <6.0% then total daily insulin must be ≥0.5 U/kg
- For females, not currently known to be pregnant. If female and sexually active, must agree to use a form of contraception to prevent pregnancy while a participant in the study. A negative urine pregnancy test will be required for all premenopausal women who are not surgically sterile. Subjects who become pregnant will be discontinued from the study.
- Demonstration of proper mental status and cognition for the study
- Currently using insulin-to-carbohydrate ratio to calculate meal bolus sizes
- Hypoglycemia awareness as demonstrated by a Clarke Hypoglycemia Unawareness score of 2 or lower
- Access to internet and cell phone service at home, and a computer for downloading device data
- Availability of care partner committed to participating in training activities, knowledgeable at all times of the participant's location, and being available to provide assistance when system is being used at night
- Commitment to maintaining uninterrupted availability via cell phone and avoiding any overnight travel for the duration the period using the closed-loop system
- An understanding of and willingness to follow the protocol and sign the informed consent
Exclusion Criteria:
- Admission for diabetic ketoacidosis in the 12 months prior to enrollment
- Severe hypoglycemia resulting in seizure or loss of consciousness in the 12 months prior to enrollment
- History of a seizure disorder (except hypoglycemic seizure), unless written clearance is received from a neurologist
- Coronary artery disease or heart failure, unless written clearance is received from a cardiologist
- History of cardiac arrhythmia (except for benign premature atrial contractions and benign premature ventricular contractions which are permitted)
- Cystic fibrosis
A known medical condition that in the judgment of the investigator might interfere with the completion of the protocol such as the following examples:
- Inpatient psychiatric treatment in the past 6 months for either the subject or the subject's primary care giver (i.e., parent or guardian)
- Presence of a known adrenal disorder
- Abnormal liver function test results (Transaminase >2 times the upper limit of normal); testing required for subjects taking medications known to affect liver function or with diseases known to affect liver function
- Abnormal renal function test results (calculated GFR <60 mL/min/1.73m2); testing required for subjects with diabetes duration of greater than 5 years post onset of puberty
- Active gastroparesis
- If on antihypertensive, thyroid, anti-depressant or lipid lowering medication, lack of stability on the medication for the past 2 months prior to enrollment in the study
- Uncontrolled thyroid disease (TSH undetectable or >10 mlU/L); testing required within three months prior to admission for subjects with a goiter or who are on thyroid hormone replacement, and within one year otherwise
- Abuse of alcohol or recreational drugs
- Infectious process not anticipated to resolve prior to study procedures (e.g. meningitis, pneumonia, osteomyelitis)
- A recent injury to body or limb, muscular disorder, use of any medication, any carcinogenic disease, or other significant medical disorder if that injury, medication or disease in the judgment of the investigator will affect the completion of the protocol
Current use of the following drugs and supplements:
- Acetaminophen
- Beta blockers
- Oral or injectable glucocorticoids
- Any other medication that the investigator believes is a contraindication to the subject's participation
Sites / Locations
- William Sansum Diabetes Center
- Mayo Clinic
- University of Virginia
Arms of the Study
Arm 1
Arm 2
Active Comparator
Experimental
Sensor-Augmented Pump Open-Loop Care (Week 2)
Closed-Loop Control System with Zone MPC and HMS
The subjects' Sensor-Augmented Pump Open-Loop Care for the second week of the study before any adjustments to pump settings, using a CGM and Insulin Pump.
The artificial pancreas system will be allowed to employ its Model Predictive Control algorithm to make decisions about insulin delivery based on CGM glucose levels. The Health Monitoring System algorithm uses the same CGM data as the MPC control algorithm but utilizes a separate algorithm for trending and predictions of future glucose values. Using a redundant and independent algorithm is an important safety feature of the overall AP device. Algorithmic adjustment of carbohydrate ratios prior to closed-loop initiation, and continued basal rate and carbohydrate ratio algorithmic optimization during closed-loop use will occur.