search
Back to results

Ultrapower; a Minimally Invasive Tool for Evaluation of Total Cardiac Power

Primary Purpose

Cardiac Diseases

Status
Completed
Phase
Not Applicable
Locations
Norway
Study Type
Interventional
Intervention
Comparison cardiac power and cardiac power output at different time points in the perioperative period
Sponsored by
Norwegian University of Science and Technology
About
Eligibility
Locations
Arms
Outcomes
Full info

About this trial

This is an interventional diagnostic trial for Cardiac Diseases focused on measuring Hemodynamics, Echocardiography, Doppler, Pulsed

Eligibility Criteria

18 Years - undefined (Adult, Older Adult)All SexesDoes not accept healthy volunteers

Inclusion Criteria:

• coronary artery bypass graft operation

Exclusion Criteria:

  • Lack of informed consent
  • Previous aortic valve replacement
  • Inadequate Doppler signal on transthoracic echocardiography

Sites / Locations

  • Department of cardiothoracic surgery

Arms of the Study

Arm 1

Arm Type

Other

Arm Label

Postoperative elective CABG patients

Arm Description

Patients included for coronary artery bypass graft (CABG) surgery, secondary to ischaemic heart disease.

Outcomes

Primary Outcome Measures

The hearts energy delivery per second measured in watts (Cardiac Power), using two established methods and the ultrapower method
Measured both as ultrapower and cardiac power output, both measured in watts and method of measurement described in intervention section
The hearts energy delivery per second measured in watts (Cardiac Power), using two established methods and the ultrapower method
The hearts energy delivery per second measured in watts (Cardiac Power), using two established methods and the ultrapower method

Secondary Outcome Measures

Full Information

First Posted
March 17, 2016
Last Updated
March 26, 2019
Sponsor
Norwegian University of Science and Technology
Collaborators
St. Olavs Hospital
search

1. Study Identification

Unique Protocol Identification Number
NCT02727634
Brief Title
Ultrapower; a Minimally Invasive Tool for Evaluation of Total Cardiac Power
Official Title
Ultrapower, an In-house Developed System for Instantaneous Logging of Ultrasound Based Blood Flow, Blood Pressure and ECG.
Study Type
Interventional

2. Study Status

Record Verification Date
March 2019
Overall Recruitment Status
Completed
Study Start Date
June 2016 (Actual)
Primary Completion Date
December 2016 (Actual)
Study Completion Date
December 2016 (Actual)

3. Sponsor/Collaborators

Responsible Party, by Official Title
Sponsor
Name of the Sponsor
Norwegian University of Science and Technology
Collaborators
St. Olavs Hospital

4. Oversight

Studies a U.S. FDA-regulated Drug Product
No
Studies a U.S. FDA-regulated Device Product
No
Data Monitoring Committee
No

5. Study Description

Brief Summary
The heart is essentially a hydraulic pump which ensures adequate delivery of blood through generating pressure and forward flow of blood. The energy delivered by the heart is uncommonly measured clinically, and todays gold standard involves placing a plastic catheter into the lung arteries. The investigators have developed an ultrasound based approach to calculate this energy without the need for catheters through the heart. This novel approach is called ultrapower. Ultrapower involves the instantaneous multiplication of the cardiac output and the arterial blood pressure. The study aims to use the ultrasound based approach to investigate Cardiac Power in the coronary artery bypass graft population.

6. Conditions and Keywords

Primary Disease or Condition Being Studied in the Trial, or the Focus of the Study
Cardiac Diseases
Keywords
Hemodynamics, Echocardiography, Doppler, Pulsed

7. Study Design

Primary Purpose
Diagnostic
Study Phase
Not Applicable
Interventional Study Model
Single Group Assignment
Masking
None (Open Label)
Allocation
N/A
Enrollment
28 (Actual)

8. Arms, Groups, and Interventions

Arm Title
Postoperative elective CABG patients
Arm Type
Other
Arm Description
Patients included for coronary artery bypass graft (CABG) surgery, secondary to ischaemic heart disease.
Intervention Type
Other
Intervention Name(s)
Comparison cardiac power and cardiac power output at different time points in the perioperative period
Intervention Description
The intervention is a comparison between two methods of calculating the heart's energy delivery, cardiac power, measured in watts. A tertiary measurement is calculation of arterioventricular coupling. All patients will have cardiac power output calculated through the use of Doppler echocardiography. The echocardiography based cardiac output will be done through the velocity time integral of the left ventricular outflow tract (LVOT). This will be compared against total power as measured by our Ultrapower approach which involves instantaneous doppler measurement of cardiac output through LVOT multiplied with simultaneous radial artery pressure. This and ejection fraction (for calculation of ventriculoarterial coupling) will be recorded at rest in neutral position preoperatively, directly post operatively and the day after operation. Directly postoperatively the power measurements will also be repeated in Trendelenburg and anti Trendelenburg position.
Primary Outcome Measure Information:
Title
The hearts energy delivery per second measured in watts (Cardiac Power), using two established methods and the ultrapower method
Description
Measured both as ultrapower and cardiac power output, both measured in watts and method of measurement described in intervention section
Time Frame
Immediately preoperatively
Title
The hearts energy delivery per second measured in watts (Cardiac Power), using two established methods and the ultrapower method
Time Frame
approximately 1 hour post operatively
Title
The hearts energy delivery per second measured in watts (Cardiac Power), using two established methods and the ultrapower method
Time Frame
1 day after operation

10. Eligibility

Sex
All
Minimum Age & Unit of Time
18 Years
Accepts Healthy Volunteers
No
Eligibility Criteria
Inclusion Criteria: • coronary artery bypass graft operation Exclusion Criteria: Lack of informed consent Previous aortic valve replacement Inadequate Doppler signal on transthoracic echocardiography
Overall Study Officials:
First Name & Middle Initial & Last Name & Degree
Idar Kirkeby-Garstad, md phd
Organizational Affiliation
Norwegian University of Science and Technology
Official's Role
Principal Investigator
Facility Information:
Facility Name
Department of cardiothoracic surgery
City
Trondheim
Country
Norway

12. IPD Sharing Statement

Plan to Share IPD
Undecided

Learn more about this trial

Ultrapower; a Minimally Invasive Tool for Evaluation of Total Cardiac Power

We'll reach out to this number within 24 hrs