Mesh Position and Outcomes Following Inguinal Hernia Repair Using an MRI Visible Hernia Mesh
Primary Purpose
Unilateral Simple Inguinal Hernia
Status
Terminated
Phase
Not Applicable
Locations
Switzerland
Study Type
Interventional
Intervention
DynaMesh visible mesh
Sponsored by
About this trial
This is an interventional treatment trial for Unilateral Simple Inguinal Hernia
Eligibility Criteria
Inclusion Criteria:
- Male patients with a primary symptomatic unilateral inguinal hernia.
- Patients eligible to undergo hernia repair either by minimally invasive (TEP, TAPP) or open techniques (e.g. Lichtenstein) as judged by the treating surgeon
- Written informed consent
Exclusion Criteria:
- Previous inguinal hernia repair
- Bilateral inguinal hernia
- Femoral hernia repair
- Repair in local anesthetics,
- Previous abdominal surgery
- Children
- Emergency surgery, e.g. incarcerated hernias
- Contraindication for MRI scans (e.g. Pacemakers and similar implants, cochlea implants, claustrophobia)
- Contraindications to usage of mesh e.g. known hypersensitivity or allergy
- Women who are pregnant or breast feeding
- Inability to follow the procedures of the study, e.g. due to language problems, psychological disorders, dementia
- American Society of Anesthesiologists (ASA) classification higher or equal to 3
Sites / Locations
- University Hospital of Basel, Department of Surgery
Arms of the Study
Arm 1
Arm 2
Arm 3
Arm Type
Experimental
Experimental
Experimental
Arm Label
Open inguinal hernia repair (Lichtenstein)
Total extraperitoneal inguinal hernia repair (TEP)
Trans abdominal preperitoneal hernia repair (TAPP)
Arm Description
Open inguinal hernia repair using a DynaMesh visible mesh
Total extraperitoneal inguinal hernia repair using a DynaMesh visible mesh
Trans abdominal preperitoneal hernia repair using a DynaMesh visible mesh
Outcomes
Primary Outcome Measures
Evaluation of Mesh Position per MRI
Secondary Outcome Measures
Evaluation of Mesh Deformation per MRI
Groin pain using visual analogue scale
Recurrence of hernia
Full Information
NCT ID
NCT02770703
First Posted
May 11, 2016
Last Updated
March 1, 2022
Sponsor
University Hospital, Basel, Switzerland
1. Study Identification
Unique Protocol Identification Number
NCT02770703
Brief Title
Mesh Position and Outcomes Following Inguinal Hernia Repair Using an MRI Visible Hernia Mesh
Official Title
Mesh Position and Outcomes Following Open (Lichtenstein), Endoscopic (TEP) and Laparoscopic (TAPP) Inguinal Hernia Repair Using a MRI Visible Hernia Mesh
Study Type
Interventional
2. Study Status
Record Verification Date
March 2022
Overall Recruitment Status
Terminated
Why Stopped
USB is responsible party on behalf of the principal investigator (PI). As PI cannot be tracked (lost to follow-up), the USB as "sponsor" set "overall recruitment status" unless the PI can be identified or tracked.
Study Start Date
April 2016 (undefined)
Primary Completion Date
March 2019 (Actual)
Study Completion Date
March 2019 (Actual)
3. Sponsor/Collaborators
Responsible Party, by Official Title
Sponsor
Name of the Sponsor
University Hospital, Basel, Switzerland
4. Oversight
Data Monitoring Committee
No
5. Study Description
Brief Summary
Inguinal hernia repair can be considered as one of the most frequent surgeries in general surgery worldwide. Surgical hernia repair procedures can generally be divided into minimally invasive (TEP, TAPP) and open techniques (e.g. Lichtenstein) and are equivalent with some advantages and disadvantages. The posterior wall of the inguinal channel is usually reinforced by a synthetic mesh, while non-mesh based surgeries have been steadily abandoned.
Two of the most frequent complications following hernia surgery are hernia recurrence and chronic groin pain. Latter can occur in up to 10%. Both represent a considerable socio-economic impact. While different surgical hernia procedures and mesh fixation techniques have been evaluated as influential factors, the impact of mesh position and mesh deformation on hernia recurrence and chronic groin pain is unknown. This may be even more important, since endoscopic and laparoscopic hernia surgery procedures (TEP, TAPP) carry the risk of suboptimal mesh positioning, due to the final steps at the end of the surgery, where the mesh position is not under direct visual control.
Until now direct mesh visualization was impossible. A recent development of MRI visible meshes (DynaMesh® visible) provides the opportunity to evaluate mesh position and deformation after hernia surgery. In case of suspicious clinical hernia recurrence or postoperative chronic groin pain the mesh position can now directly be identified with Magnetic Resonance (MR) imaging preventing unnecessary explorative surgery.
In this study the investigators plan to perform MRI scans to assess mesh position and deformation 90 days postoperatively and correlate it with the clinical status and pain score (VAS) of the patient. In order to allow for an optimal comparison of the post-operative mesh position in relation to the operative technique, patients will be randomized to minimally invasive (TEP, TAPP) and open techniques (e.g. Lichtenstein). To the investigators knowledge this is the first study investigating the impact of the three most common surgical hernia procedures on postoperative mesh position and deformation and its correlation to the clinical findings focussing on hernia recurrence and chronic groin pain.
6. Conditions and Keywords
Primary Disease or Condition Being Studied in the Trial, or the Focus of the Study
Unilateral Simple Inguinal Hernia
7. Study Design
Primary Purpose
Treatment
Study Phase
Not Applicable
Interventional Study Model
Parallel Assignment
Masking
Outcomes Assessor
Allocation
Randomized
Enrollment
60 (Actual)
8. Arms, Groups, and Interventions
Arm Title
Open inguinal hernia repair (Lichtenstein)
Arm Type
Experimental
Arm Description
Open inguinal hernia repair using a DynaMesh visible mesh
Arm Title
Total extraperitoneal inguinal hernia repair (TEP)
Arm Type
Experimental
Arm Description
Total extraperitoneal inguinal hernia repair using a DynaMesh visible mesh
Arm Title
Trans abdominal preperitoneal hernia repair (TAPP)
Arm Type
Experimental
Arm Description
Trans abdominal preperitoneal hernia repair using a DynaMesh visible mesh
Intervention Type
Device
Intervention Name(s)
DynaMesh visible mesh
Intervention Description
Implantation of a MRI visible mesh
Primary Outcome Measure Information:
Title
Evaluation of Mesh Position per MRI
Time Frame
90 days postoperatively
Secondary Outcome Measure Information:
Title
Evaluation of Mesh Deformation per MRI
Time Frame
90 days postoperatively
Title
Groin pain using visual analogue scale
Time Frame
0, 1, 90, 365 days postoperatively
Title
Recurrence of hernia
Time Frame
0, 1, 90, 365 days postoperatively
10. Eligibility
Sex
Male
Minimum Age & Unit of Time
18 Years
Accepts Healthy Volunteers
No
Eligibility Criteria
Inclusion Criteria:
Male patients with a primary symptomatic unilateral inguinal hernia.
Patients eligible to undergo hernia repair either by minimally invasive (TEP, TAPP) or open techniques (e.g. Lichtenstein) as judged by the treating surgeon
Written informed consent
Exclusion Criteria:
Previous inguinal hernia repair
Bilateral inguinal hernia
Femoral hernia repair
Repair in local anesthetics,
Previous abdominal surgery
Children
Emergency surgery, e.g. incarcerated hernias
Contraindication for MRI scans (e.g. Pacemakers and similar implants, cochlea implants, claustrophobia)
Contraindications to usage of mesh e.g. known hypersensitivity or allergy
Women who are pregnant or breast feeding
Inability to follow the procedures of the study, e.g. due to language problems, psychological disorders, dementia
American Society of Anesthesiologists (ASA) classification higher or equal to 3
Overall Study Officials:
First Name & Middle Initial & Last Name & Degree
Robert Mechera, MD
Organizational Affiliation
University Hospital of Basel, Department of Surgery
Official's Role
Principal Investigator
Facility Information:
Facility Name
University Hospital of Basel, Department of Surgery
City
Basel
ZIP/Postal Code
4031
Country
Switzerland
12. IPD Sharing Statement
Plan to Share IPD
No
Learn more about this trial
Mesh Position and Outcomes Following Inguinal Hernia Repair Using an MRI Visible Hernia Mesh
We'll reach out to this number within 24 hrs