search
Back to results

Transfemoral Replacement of Aortic Valve With HLT MeriDIAN Valve Early Feasibility Trial (RADIANT)

Primary Purpose

Aortic Valve Stenosis

Status
Terminated
Phase
Not Applicable
Locations
United States
Study Type
Interventional
Intervention
HLT Transcatheter Aortic Valve System
Sponsored by
HLT Inc.
About
Eligibility
Locations
Arms
Outcomes
Full info

About this trial

This is an interventional treatment trial for Aortic Valve Stenosis focused on measuring aortic stenosis, transcatheter aortic valve replacement

Eligibility Criteria

70 Years - undefined (Older Adult)All SexesDoes not accept healthy volunteers

Inclusion Criteria:

  1. 70 years of age or older
  2. Echocardiographic or hemodynamic based evidence of calcific (senile) aortic stenosis with one of the following: aortic valve EOA <1.0 cm2 or 0.6 cm2/m2, mean aortic valve gradient >40 mmHg or peak aortic valve velocity >4 m/sec
  3. Symptoms due to aortic stenosis resulting in one of the following:

    1. New York Heart Association (NYHA) Functional Classification of II or greater
    2. Presence of angina
    3. Presence of syncope
  4. Documented aortic valve annular diameter ≥ 21 and ≤ 24 mm (associated perimeter range is 66.0 - 75.4 mm or associated area range of 346 - 452 mm2) measured by the multislice computed tomography (MSCT) Core Lab assessment of pre-procedure imaging.
  5. Documented heart team agreement of high risk for surgical aortic valve replacement (SAVR) due to frailty or comorbidities such as:

    • Society of Thoracic Surgeons (STS) score of ≥8%
    • Frailty as indicated by one of the following:

      • Five meter walk test > 6 seconds
      • Katz activities of daily living (ADL) score of 3/6 or less
      • Body Mass Index < 20 kg/m2
      • Wheelchair bound, unable to live independently
    • Childs Class A or B liver disease
    • Severe lung disease (need for supplemental oxygen, forced expiratory volume at one second (FEV1) < 50% of predicted, diffusing capacity of the lungs for carbon monoxide (DLCO) < 60%, or other evidence of severe pulmonary dysfunction
    • Previous coronary artery bypass graft(s) at risk for re-operation
    • Serum albumin < 3.5 g/dL
    • Other evidence that subject is at high risk for surgical valve replacement by one of the following:

      • Hostile chest
      • Porcelain aorta
      • Severe pulmonary hypertension (> 60 mmHg)
      • Prior chest radiation therapy
      • Neuromuscular disease that creates risk for mechanical ventilation or rehabilitation after surgical aortic valve replacement
      • Orthopedic disease that creates risk for rehabilitation after surgical aortic valve replacement
  6. Geographically available, willing to comply with follow up and able to provide written informed consent

Exclusion Criteria:

  1. Congenital unicuspid or bicuspid aortic valve, or noncalcified aortic valve; or valve eccentricity (calcific or otherwise) which could compromise procedural success.
  2. Patients with a coronary height of < 10mm, or otherwise determined to be high risk for coronary obstruction
  3. Patients with low flow/low gradient aortic stenosis
  4. Patients with significant annular or left ventricular outflow tract (LVOT) calcification that could compromise procedural success
  5. Pre-existing prosthetic heart valve in any position
  6. Severe aortic, mitral or tricuspid valve regurgitation
  7. Moderate to severe mitral stenosis
  8. Myocardial infarction within the past 30 days*
  9. Echocardiographic evidence of intracardiac mass, thrombus, or vegetation
  10. Left Ventricular Ejection Fraction (LVEF) < 30%
  11. Severe pulmonary hypertension with pulmonary systolic pressure greater than two- thirds of systemic pressure
  12. Hemodynamic instability requiring inotropic drug therapy within the past 14 days
  13. Untreated clinically significant coronary artery disease requiring revascularization
  14. Presence of significant aortic disease such as atheroma, thrombus, or aneurysm which precludes safe implant delivery
  15. Blood dyscrasias defined as leukopenia (White blood cell count < 1,000 cell/mm3), anemia (hemoglobin < 9.0 g/dL), thrombocytopenia (platelet count < 50,000 cells/mm3), history of bleeding diathesis or coagulopathy
  16. Patient ineligible for or refuses blood transfusions
  17. Unfavorable peripheral vascular anatomy or disease (e.g. severe obstructive calcification, severe tortuosity) that would preclude passage of 18 French (18F) catheters from the femoral arterial access to the aorta as evidenced by peripheral MSCT
  18. Active peptic ulcer or gastrointestinal bleeding within the past 90 days, that would not allow treatment with the protocol antiplatelet regimen post implant *
  19. Symptoms of carotid or vertebral artery disease (e.g. stroke or transient ischemic attack) within past 6 months, or treatment of carotid stenosis within past two months*
  20. Renal disease as demonstrated by a serum creatinine > 2.5 mg/dL or end stage renal disease
  21. Active infection (including endocarditis) requiring ongoing treatment
  22. Need for emergent surgery or intervention other than the investigational procedure
  23. Any therapeutic invasive cardiac procedure performed or planned to perform within 30 days of the index procedure, except for percutaneous coronary intervention (PCI) which is performed within 7 days prior to the index procedure*
  24. Hypersensitivity or contraindication to procedural medication and device materials (e.g. titanium, nickel, pork) which cannot be adequately premedicated
  25. Life expectancy < 1 year due to non-cardiac co-morbid conditions
  26. Currently participating in any investigational drug or device studies that may confound the results of this study
  27. History of any cognitive or mental health status that would interfere with study participation
  28. Following surgical consultation, patient is deemed inoperable in the event that surgical intervention is required after Meridian valve implantation
  29. Patients with a history of hypertrophic cardiomyopathy
  30. Aortic root angle ≥ 70˚ as determined by the MSCT Core Lab assessment of pre- procedure imaging
  31. Unfavorable left ventricular anatomy (e.g., size or shape) as evidenced by pre- procedure imaging * At the time of procedure, if a subject's medical status has changed since enrollment, the subject shall be re-evaluated for eligibility

Sites / Locations

  • MedStar Health
  • St. Vincent Heart Center of Indiana
  • NYU Langone Medical Center
  • The Lindner Center for Research and Education at the Christ Hospital
  • Baylor Scott & White The Heart Hospital Plano

Arms of the Study

Arm 1

Arm Type

Experimental

Arm Label

HLT Transcatheter Aortic Valve System

Arm Description

Transcatheter aortic valve replacement with HLT Transcatheter Aortic Valve System

Outcomes

Primary Outcome Measures

Primary Endpoint: Mortality at 30 days
The primary safety endpoint is all-cause mortality at 30 days.

Secondary Outcome Measures

Secondary Performance Endpoint 1: Procedural Device Performance
The secondary performance endpoint is Device Success defined as: Absence of procedural mortality AND Correct positioning of a single Valve into the proper anatomical location AND Intended performance of the Valve (no severe prosthesis-patient mismatch and clinically acceptable gradient) AND no moderate or severe aortic valve regurgitation)
Secondary Performance Endpoint 2: Post-procedural Valve Performance
The Valve performance will be evaluated by the following parameters with echocardiograms obtained at pre-discharge, 1, 6, 12, 24, 36, 48 and 60 months: Aortic valve effective orifice area (EOA) Severity of aortic valve regurgitation (AR) Aortic valve gradient
Secondary Safety Endpoint 3: Adverse Events
All adverse events will be assessed throughout the 5 year follow up period.

Full Information

First Posted
June 3, 2016
Last Updated
May 29, 2023
Sponsor
HLT Inc.
search

1. Study Identification

Unique Protocol Identification Number
NCT02799823
Brief Title
Transfemoral Replacement of Aortic Valve With HLT MeriDIAN Valve Early Feasibility Trial
Acronym
RADIANT
Official Title
Transfemoral Replacement of Aortic Valve With HLT MeriDIAN Valve Early Feasibility Trial
Study Type
Interventional

2. Study Status

Record Verification Date
May 2023
Overall Recruitment Status
Terminated
Why Stopped
HLT Business Decision
Study Start Date
April 27, 2017 (Actual)
Primary Completion Date
January 20, 2023 (Actual)
Study Completion Date
January 20, 2023 (Actual)

3. Sponsor/Collaborators

Responsible Party, by Official Title
Sponsor
Name of the Sponsor
HLT Inc.

4. Oversight

Studies a U.S. FDA-regulated Drug Product
No
Studies a U.S. FDA-regulated Device Product
Yes
Device Product Not Approved or Cleared by U.S. FDA
Yes
Data Monitoring Committee
Yes

5. Study Description

Brief Summary
The purpose of this study is to evaluate the safety and performance of the HLT System in patients with severe aortic stenosis who present at High Risk for aortic valve replacement surgery.

6. Conditions and Keywords

Primary Disease or Condition Being Studied in the Trial, or the Focus of the Study
Aortic Valve Stenosis
Keywords
aortic stenosis, transcatheter aortic valve replacement

7. Study Design

Primary Purpose
Treatment
Study Phase
Not Applicable
Interventional Study Model
Single Group Assignment
Masking
None (Open Label)
Allocation
N/A
Enrollment
11 (Actual)

8. Arms, Groups, and Interventions

Arm Title
HLT Transcatheter Aortic Valve System
Arm Type
Experimental
Arm Description
Transcatheter aortic valve replacement with HLT Transcatheter Aortic Valve System
Intervention Type
Device
Intervention Name(s)
HLT Transcatheter Aortic Valve System
Intervention Description
Transcatheter aortic valve replacement with HLT Transcatheter Aortic Valve System
Primary Outcome Measure Information:
Title
Primary Endpoint: Mortality at 30 days
Description
The primary safety endpoint is all-cause mortality at 30 days.
Time Frame
30 days
Secondary Outcome Measure Information:
Title
Secondary Performance Endpoint 1: Procedural Device Performance
Description
The secondary performance endpoint is Device Success defined as: Absence of procedural mortality AND Correct positioning of a single Valve into the proper anatomical location AND Intended performance of the Valve (no severe prosthesis-patient mismatch and clinically acceptable gradient) AND no moderate or severe aortic valve regurgitation)
Time Frame
1 day
Title
Secondary Performance Endpoint 2: Post-procedural Valve Performance
Description
The Valve performance will be evaluated by the following parameters with echocardiograms obtained at pre-discharge, 1, 6, 12, 24, 36, 48 and 60 months: Aortic valve effective orifice area (EOA) Severity of aortic valve regurgitation (AR) Aortic valve gradient
Time Frame
pre-discharge, 1, 6, 12, 24, 36, 48 and 60 months
Title
Secondary Safety Endpoint 3: Adverse Events
Description
All adverse events will be assessed throughout the 5 year follow up period.
Time Frame
Throughout the 5 year follow up period

10. Eligibility

Sex
All
Minimum Age & Unit of Time
70 Years
Accepts Healthy Volunteers
No
Eligibility Criteria
Inclusion Criteria: 70 years of age or older Echocardiographic or hemodynamic based evidence of calcific (senile) aortic stenosis with one of the following: aortic valve EOA <1.0 cm2 or 0.6 cm2/m2, mean aortic valve gradient >40 mmHg or peak aortic valve velocity >4 m/sec Symptoms due to aortic stenosis resulting in one of the following: New York Heart Association (NYHA) Functional Classification of II or greater Presence of angina Presence of syncope Documented aortic valve annular diameter ≥ 21 and ≤ 24 mm (associated perimeter range is 66.0 - 75.4 mm or associated area range of 346 - 452 mm2) measured by the multislice computed tomography (MSCT) Core Lab assessment of pre-procedure imaging. Documented heart team agreement of high risk for surgical aortic valve replacement (SAVR) due to frailty or comorbidities such as: Society of Thoracic Surgeons (STS) score of ≥8% Frailty as indicated by one of the following: Five meter walk test > 6 seconds Katz activities of daily living (ADL) score of 3/6 or less Body Mass Index < 20 kg/m2 Wheelchair bound, unable to live independently Childs Class A or B liver disease Severe lung disease (need for supplemental oxygen, forced expiratory volume at one second (FEV1) < 50% of predicted, diffusing capacity of the lungs for carbon monoxide (DLCO) < 60%, or other evidence of severe pulmonary dysfunction Previous coronary artery bypass graft(s) at risk for re-operation Serum albumin < 3.5 g/dL Other evidence that subject is at high risk for surgical valve replacement by one of the following: Hostile chest Porcelain aorta Severe pulmonary hypertension (> 60 mmHg) Prior chest radiation therapy Neuromuscular disease that creates risk for mechanical ventilation or rehabilitation after surgical aortic valve replacement Orthopedic disease that creates risk for rehabilitation after surgical aortic valve replacement Geographically available, willing to comply with follow up and able to provide written informed consent Exclusion Criteria: Congenital unicuspid or bicuspid aortic valve, or noncalcified aortic valve; or valve eccentricity (calcific or otherwise) which could compromise procedural success. Patients with a coronary height of < 10mm, or otherwise determined to be high risk for coronary obstruction Patients with low flow/low gradient aortic stenosis Patients with significant annular or left ventricular outflow tract (LVOT) calcification that could compromise procedural success Pre-existing prosthetic heart valve in any position Severe aortic, mitral or tricuspid valve regurgitation Moderate to severe mitral stenosis Myocardial infarction within the past 30 days* Echocardiographic evidence of intracardiac mass, thrombus, or vegetation Left Ventricular Ejection Fraction (LVEF) < 30% Severe pulmonary hypertension with pulmonary systolic pressure greater than two- thirds of systemic pressure Hemodynamic instability requiring inotropic drug therapy within the past 14 days Untreated clinically significant coronary artery disease requiring revascularization Presence of significant aortic disease such as atheroma, thrombus, or aneurysm which precludes safe implant delivery Blood dyscrasias defined as leukopenia (White blood cell count < 1,000 cell/mm3), anemia (hemoglobin < 9.0 g/dL), thrombocytopenia (platelet count < 50,000 cells/mm3), history of bleeding diathesis or coagulopathy Patient ineligible for or refuses blood transfusions Unfavorable peripheral vascular anatomy or disease (e.g. severe obstructive calcification, severe tortuosity) that would preclude passage of 18 French (18F) catheters from the femoral arterial access to the aorta as evidenced by peripheral MSCT Active peptic ulcer or gastrointestinal bleeding within the past 90 days, that would not allow treatment with the protocol antiplatelet regimen post implant * Symptoms of carotid or vertebral artery disease (e.g. stroke or transient ischemic attack) within past 6 months, or treatment of carotid stenosis within past two months* Renal disease as demonstrated by a serum creatinine > 2.5 mg/dL or end stage renal disease Active infection (including endocarditis) requiring ongoing treatment Need for emergent surgery or intervention other than the investigational procedure Any therapeutic invasive cardiac procedure performed or planned to perform within 30 days of the index procedure, except for percutaneous coronary intervention (PCI) which is performed within 7 days prior to the index procedure* Hypersensitivity or contraindication to procedural medication and device materials (e.g. titanium, nickel, pork) which cannot be adequately premedicated Life expectancy < 1 year due to non-cardiac co-morbid conditions Currently participating in any investigational drug or device studies that may confound the results of this study History of any cognitive or mental health status that would interfere with study participation Following surgical consultation, patient is deemed inoperable in the event that surgical intervention is required after Meridian valve implantation Patients with a history of hypertrophic cardiomyopathy Aortic root angle ≥ 70˚ as determined by the MSCT Core Lab assessment of pre- procedure imaging Unfavorable left ventricular anatomy (e.g., size or shape) as evidenced by pre- procedure imaging * At the time of procedure, if a subject's medical status has changed since enrollment, the subject shall be re-evaluated for eligibility
Overall Study Officials:
First Name & Middle Initial & Last Name & Degree
Mathew Williams, MD
Organizational Affiliation
NYU Langone Medical Center
Official's Role
Principal Investigator
First Name & Middle Initial & Last Name & Degree
Dean Kereiakes, MD
Organizational Affiliation
The Christ Hospital
Official's Role
Principal Investigator
Facility Information:
Facility Name
MedStar Health
City
Washington
State/Province
District of Columbia
ZIP/Postal Code
20010
Country
United States
Facility Name
St. Vincent Heart Center of Indiana
City
Indianapolis
State/Province
Indiana
ZIP/Postal Code
46290
Country
United States
Facility Name
NYU Langone Medical Center
City
New York
State/Province
New York
ZIP/Postal Code
10016
Country
United States
Facility Name
The Lindner Center for Research and Education at the Christ Hospital
City
Cincinnati
State/Province
Ohio
ZIP/Postal Code
45219
Country
United States
Facility Name
Baylor Scott & White The Heart Hospital Plano
City
Plano
State/Province
Texas
ZIP/Postal Code
75093
Country
United States

12. IPD Sharing Statement

Plan to Share IPD
No
Citations:
PubMed Identifier
31362540
Citation
Rodes-Cabau J, Williams MR, Wijeysundera HC, Kereiakes DJ, Paradis JM, Staniloae C, Saric M, Radhakrishnan S, Wilson RF, Kubo SH. Transcatheter Aortic Valve Replacement With the HLT Meridian Valve. Circ Cardiovasc Interv. 2019 Aug;12(8):e008053. doi: 10.1161/CIRCINTERVENTIONS.119.008053. Epub 2019 Jul 31.
Results Reference
derived

Learn more about this trial

Transfemoral Replacement of Aortic Valve With HLT MeriDIAN Valve Early Feasibility Trial

We'll reach out to this number within 24 hrs