Clinical Comparison of Different Humidification Strategies During Noninvasive Ventilation With Helmet
Primary Purpose
Respiratory Failure
Status
Completed
Phase
Not Applicable
Locations
Italy
Study Type
Interventional
Intervention
Measurements
Sponsored by
About this trial
This is an interventional treatment trial for Respiratory Failure focused on measuring Noninvasive Ventilation, Mechanical Ventilation
Eligibility Criteria
Inclusion Criteria:
- Awake and collaborative patients
- Age>18 years
- Need for noninvasive mechanical ventilation
- Informed consent
Exclusion Criteria:
- Cardiopulmonary resuscitation
- Haemodynamic instability
- Coma
- Asma
- Hypercapnia (paCO2>45 mmHg)
- Recent gastric or abdominal surgery
Sites / Locations
- General ICU, A. Gemelli hospital
Arms of the Study
Arm 1
Arm 2
Arm 3
Arm 4
Arm Type
Experimental
Experimental
Experimental
Experimental
Arm Label
HME
HH33
HH37
NoH
Arm Description
Passive humidification with heat and moisture exchanger, Y-piece circuit.
Heated humification (MR 730, Fisher & Paykel, Auckland, New Zealand), humidification chamber temperature 33°C.
Heated humification (MR 730, Fisher & Paykel, Auckland, New Zealand), humidification chamber temperature 33°C.
Passive humidification, double tube circuit
Outcomes
Primary Outcome Measures
Comfort assessed by visual analogic scale modified for ICU patients
Patient's comfort, assessed by visual analogic scale modified for ICU patients
Patient-ventilator asynchrony. Asynchrony index
Asynchrony index number of asynchrony events divided by the total respiratory rate computed as the sum of the number of ventilator cycles (triggered or not) and of wasted efforts. Inspiratory trigger delay (time between the onset of patient's effort and ventilatory support). Pressurization and depressurization efficacy.
Work of breathing. Oesophageal pressure time product
Pressure time product of the esophageal pressure (PTPes) and pressure time product of the transdiaphragmatic pressure (PTPdi)
Secondary Outcome Measures
PaO2
respiratory rate
Dyspnea
Borg dyspnea score
Helmet humidity
Helmet temperature
PaCO2
Full Information
NCT ID
NCT02875379
First Posted
July 27, 2015
Last Updated
January 23, 2019
Sponsor
Catholic University of the Sacred Heart
1. Study Identification
Unique Protocol Identification Number
NCT02875379
Brief Title
Clinical Comparison of Different Humidification Strategies During Noninvasive Ventilation With Helmet
Official Title
Clinical Comparison of Different Humidification Strategies During Noninvasive Ventilation With Helmet
Study Type
Interventional
2. Study Status
Record Verification Date
January 2019
Overall Recruitment Status
Completed
Study Start Date
February 1, 2017 (Actual)
Primary Completion Date
January 23, 2019 (Actual)
Study Completion Date
January 23, 2019 (Actual)
3. Sponsor/Collaborators
Responsible Party, by Official Title
Principal Investigator
Name of the Sponsor
Catholic University of the Sacred Heart
4. Oversight
Studies a U.S. FDA-regulated Drug Product
No
Studies a U.S. FDA-regulated Device Product
No
Data Monitoring Committee
No
5. Study Description
Brief Summary
Background. Non invasive positive pressure ventilation (NIV) is among first line treatments of acute respiratory failure. Several interfaces are available for non-invasive ventilation.Despite full face and oronasal masks are more frequently used, some evidence suggests that helmets may optimize patients' comfort and NIV tolerability.
During NIV, humidification strategies (heat and moisture exchangers HME or heated humidifiers HH) may significantly affect patient's comfort and work of breathing.
Despite physiological data suggested heated humidification as the best strategy during NIV with full face masks, no differences were found in a randomized controlled study assessing the effects of HME or HH on a pragmatic clinical outcome.
However, the higher dead space (i.e. 18 L/min) and rebreathing rate observed during helmet NIV make such results not applicable to this particular setting.
The investigators designed a randomized-crossover trial to assess the effect of four humidification strategies during helmet NIV on patients with acute respiratory failure, in terms of comfort, work of breathing and patient-ventilator interaction.
Methods. All awake, collaborative, hypoxemic patients requiring mechanical ventilation will be considered for the enrollment. Hypercapnic patients (i.e.PaCO2>45 mmHg) will be excluded.
Each enrolled patient will undergo helmet NIV with all the following humidification strategies in a random order. Each period will last 60 minutes.
Passive humidification, double tube circuit.
Heated humification (MR 730, Fisher & Paykel, Auckland, New Zealand), humidification chamber temperature 33°C.
Heated humification (MR 730, Fisher & Paykel, Auckland, New Zealand), humidification chamber temperature 37°C.
Passive humidification with HME, Y-piece circuit.
Ventilatory settings (Draeger Evita xl or Evita infinity ventilators):
Pressure support ventilation; pressure support=20 cmH20; FiO2 titrated to obtain SpO2 between 92 and 98%; positive end-expiratory pressure=10 cmH2O; maximum inspiratory time 0.9 seconds; inspiratory flow trigger = 2 l/min; expiratory trigger: 30% of the maximum inspiratory flow; pressurization time=0,00 s.
Such settings will be kept unchanged during the whole study period. An oesophageal catheter will be placed and secured to measure oesophageal pressure (Pes) and gastric pressure (Pga) (Nutrivent, Italy): the reliability of the measured pressure will be confirmed with an airway occlusion test during NIV with oronasal mask. Work of breathing will be estimated with the pressure-time product (PTP) of the pleural pressure.
A pneumotachograph (KleisTek) will record flow, airway pressure, Pes and Pga on a dedicated laptop.
At the end of each cycle, the patient will be asked to rate his/her discomfort on a visual analog scale (VAS) modified for ICU patients. The level of dyspnea will be assessed with the Borg dyspnea scale.
The following parameters will be record at the end of each cycle:
Arterial pressure, heart rate, respiratory rate, SpO2, pH, PCO2, PaO2, SaO2. Airway and esophageal pressure signals will be reviewed offline to detect patient-ventilator asynchronies (ineffective efforts, double cycling, premature cycling, delayed cycling) and asynchrony index (number of asynchrony events divided by the total respiratory rate computed as the sum of the number of ventilator cycles (triggered or not) and of wasted efforts) will be computed. The trigger delay will be also measured. The pressurization and depressurization velocity will be assessed with the PTP airway index 300 and 500 (inspiratory and expiratory), as suggested by Ferrone and coworkers. The work of breathing (WOB) for each breath will be estimated by PTPes.
An hygrometer (Dimar SRL, Italy) will measure and record on a dedicated laptop Helmet temperature, relative and absolute humidity.
Primary endpoints: patient's comfort, work of breathing and asynchrony index.
Sample Sizing:
Given the physiological design of the study, the investigators did not make an a priori sample size and plan to enroll 24 patients.
Detailed Description
Background Non invasive positive pressure ventilation (NIV) is among first line treatments of acute respiratory failure. In patients with new-onset respiratory failure, NIV was showed to reduce the rate of complications and the length of ICU stay, as compared to invasive mechanical ventilation[1] Several interfaces are available for non-invasive ventilation: full face masks, oronasal masks, nasal prongs and helmets[2].
Despite full face and oronasal masks are more frequently used, some evidence suggests that helmets may optimize patients' comfort and NIV tolerability. The helmet allows patients' interaction, speech, feeding and does not limit cough. In addition, skin necrosis, gastric distension, or eye irritation are seldom observed during helmet NIV, while may be consequences of long-term treatments with face masks. [3] On the contrary, helmet NIV hampers tidal volume monitoring, is contraindicated in hypercapnic patients and requires specific ventilator settings[4]. Lastly, when compared to face masks, helmets may increase the work of breathing and worsen patient-ventilator interaction[5][6][7].
During NIV, humidification strategies (heat and moisture exchangers HME or heated humidifiers HH) may significantly affect patient's comfort and work of breathing [8][9].
Despite physiological data suggested heated humidification as the best strategy during NIV with full face masks[8][9], no differences were found in a randomized controlled study assessing the effects of HME or HH on a pragmatic clinical outcome[10].
However, the higher dead space (i.e. 18 L/min) and rebreathing rate observed during helmet NIV make such results not applicable to this particular setting.
One only study assessed the effects of a HH during helmet low-flow continuous positive airway pressure on comfort in healthy volunteers[11]. Indeed, patients suffering from acute respiratory failure may behave differently, especially in terms of minute ventilation and maximum inspiratory flow.
A recent bench study identified a better patient-ventilator interaction when helmet NIV was provided through a double tube circuit, as compared to the Y-piece system [12]. The investigators designed a randomized-crossover trial to assess the effect of four humidification strategies during helmet NIV on patients with acute respiratory failure, in terms of comfort, work of breathing and patient-ventilator interaction.
Methods Design: monocentric, randomized, cross-over trial. Each enrolled patient will undergo helmet NIV with all the following humidification strategies in a random order. Each period will last 60 minutes.
Passive humidification, double tube circuit.
Heated humification (MR 730, Fisher & Paykel, Auckland, New Zealand), humidification chamber temperature 33°C.
Heated humification (MR 730, Fisher & Paykel, Auckland, New Zealand), humidification chamber temperature 37°C.
Passive humidification with HME, Y-piece circuit.
Ventilatory settings (Draeger Evita xl or Evita infinity ventilators):
Pressure support ventilation; pressure support=20 cmH20[4]; FiO2 titrated to obtain SpO2 between 92 and 98%; positive end-expiratory pressure=10 cmH2O[4]; maximum inspiratory time 0.9 seconds; inspiratory flow trigger = 2 l/min; expiratory trigger: 30% of the maximum inspiratory flow; pressurization time=0,00 s.
Such settings will be kept unchanged during the whole study period. An oesophageal catheter will be placed and secured to measure oesophageal pressure (Pes) and gastric pressure (Pga) (Nutrivent, Italy): the reliability of the measured pressure will be confirmed with an airway occlusion test during NIV with oronasal mask[13]. Work of breathing will be estimated with the pressure-time product (PTP) of the pleural pressure[13].
A pneumotachograph (KleisTek) will record flow, airway pressure, Pes and Pga on a dedicated laptop.
At the end of each cycle, the patient will be asked to rate his/her discomfort on a visual analog scale (VAS) modified for ICU patients. The level of dyspnea will be assessed with the Borg dyspnea scale[14].
The following parameters will be record at the end of each cycle:
Arterial pressure, heart rate, respiratory rate, SpO2, pH, PCO2, PaO2, SaO2. Airway and esophageal pressure signals will be reviewed offline to detect patient-ventilator asynchronies (ineffective efforts, double cycling, premature cycling, delayed cycling) and asynchrony index (number of asynchrony events divided by the total respiratory rate computed as the sum of the number of ventilator cycles (triggered or not) and of wasted efforts) will be computed[15]. The trigger delay will be also measured. The pressurization and depressurization velocity will be assessed with the PTP airway index 300 and 500 (inspiratory and expiratory), as suggested by Ferrone and coworkers[12]. The work of breathing (WOB) for each breath will be estimated by PTPes.
An hygrometer (Dimar SRL, Italy) will measure and record on a dedicated laptop Helmet temperature, relative and absolute humidity.
End point:
Primary endpoints: patient's comfort, work of breathing and asynchrony index.
Sample Sizing:
Given the physiological design of the study, the investigators did not make an a priori sample size and planned to enroll 24 patients.
Statistical analysis Qualitative data will be expressed as number of events (%) and continuous data as mean ± standard deviation or median [Interquartile range]. Comparisons concerning qualitative variables will be performed with the Mc-Namar test. Ordinal qualitative variables or non normal quantitative variables will be compared with the Friedman's Test, the wilcoxon sum of ranks test or the Mann-Whitney test, as appropriate. All analysis will be performed applying a bilateral hypothesis. P ≤ 0.05 will be considered significant. Statistical analysis will be performed with SPSS 20.0.
6. Conditions and Keywords
Primary Disease or Condition Being Studied in the Trial, or the Focus of the Study
Respiratory Failure
Keywords
Noninvasive Ventilation, Mechanical Ventilation
7. Study Design
Primary Purpose
Treatment
Study Phase
Not Applicable
Interventional Study Model
Crossover Assignment
Masking
None (Open Label)
Allocation
Randomized
Enrollment
20 (Actual)
8. Arms, Groups, and Interventions
Arm Title
HME
Arm Type
Experimental
Arm Description
Passive humidification with heat and moisture exchanger, Y-piece circuit.
Arm Title
HH33
Arm Type
Experimental
Arm Description
Heated humification (MR 730, Fisher & Paykel, Auckland, New Zealand), humidification chamber temperature 33°C.
Arm Title
HH37
Arm Type
Experimental
Arm Description
Heated humification (MR 730, Fisher & Paykel, Auckland, New Zealand), humidification chamber temperature 33°C.
Arm Title
NoH
Arm Type
Experimental
Arm Description
Passive humidification, double tube circuit
Intervention Type
Procedure
Intervention Name(s)
Measurements
Intervention Description
Measurements of respiratory mechanics and parameters, arterial blood gases and comfort
Primary Outcome Measure Information:
Title
Comfort assessed by visual analogic scale modified for ICU patients
Description
Patient's comfort, assessed by visual analogic scale modified for ICU patients
Time Frame
At the end of each 1-hour ventilation period
Title
Patient-ventilator asynchrony. Asynchrony index
Description
Asynchrony index number of asynchrony events divided by the total respiratory rate computed as the sum of the number of ventilator cycles (triggered or not) and of wasted efforts. Inspiratory trigger delay (time between the onset of patient's effort and ventilatory support). Pressurization and depressurization efficacy.
Time Frame
At the end of each 1-hour ventilation period
Title
Work of breathing. Oesophageal pressure time product
Description
Pressure time product of the esophageal pressure (PTPes) and pressure time product of the transdiaphragmatic pressure (PTPdi)
Time Frame
At the end of each 1-hour ventilation period
Secondary Outcome Measure Information:
Title
PaO2
Time Frame
At the end of each 1-hour ventilation period
Title
respiratory rate
Time Frame
At the end of each 1-hour ventilation period
Title
Dyspnea
Description
Borg dyspnea score
Time Frame
At the end of each 1-hour ventilation period
Title
Helmet humidity
Time Frame
At the end of each 1-hour ventilation period
Title
Helmet temperature
Time Frame
At the end of each 1-hour ventilation period
Title
PaCO2
Time Frame
At the end of each 1-hour ventilation period
10. Eligibility
Sex
All
Minimum Age & Unit of Time
18 Years
Accepts Healthy Volunteers
No
Eligibility Criteria
Inclusion Criteria:
Awake and collaborative patients
Age>18 years
Need for noninvasive mechanical ventilation
Informed consent
Exclusion Criteria:
Cardiopulmonary resuscitation
Haemodynamic instability
Coma
Asma
Hypercapnia (paCO2>45 mmHg)
Recent gastric or abdominal surgery
Facility Information:
Facility Name
General ICU, A. Gemelli hospital
City
Rome
ZIP/Postal Code
00100
Country
Italy
12. IPD Sharing Statement
Plan to Share IPD
Undecided
Citations:
PubMed Identifier
34952962
Citation
Bongiovanni F, Grieco DL, Anzellotti GM, Menga LS, Michi T, Cesarano M, Raggi V, De Bartolomeo C, Mura B, Mercurio G, D'Arrigo S, Bello G, Maviglia R, Pennisi MA, Antonelli M. Gas conditioning during helmet noninvasive ventilation: effect on comfort, gas exchange, inspiratory effort, transpulmonary pressure and patient-ventilator interaction. Ann Intensive Care. 2021 Dec 24;11(1):184. doi: 10.1186/s13613-021-00972-9.
Results Reference
derived
Learn more about this trial
Clinical Comparison of Different Humidification Strategies During Noninvasive Ventilation With Helmet
We'll reach out to this number within 24 hrs