search
Back to results

A Study in Patients With Venous Leg Ulcers and Measuring the Effects of Using Geko™ Device

Primary Purpose

Venous Leg Ulcer

Status
Completed
Phase
Not Applicable
Locations
United Kingdom
Study Type
Interventional
Intervention
geko™ device
Sponsored by
Firstkind Ltd
About
Eligibility
Locations
Arms
Outcomes
Full info

About this trial

This is an interventional other trial for Venous Leg Ulcer

Eligibility Criteria

18 Years - 99 Years (Adult, Older Adult)All SexesDoes not accept healthy volunteers

Inclusion Criteria:

  1. Age ≥ 18 years
  2. Intact healthy skin at the site of device application
  3. Able to understand the Patient Information Sheet
  4. Willing and able to give informed consent
  5. Willing and able to follow the requirements of the protocol
  6. Subjects who had a chronic venous leg ulcer (i.e. CEAP classification of C6 1) greater than 1 cm2 and less than 10 cm in maximum diameter,
  7. ABPI of ≥0.8
  8. Patient treated with 4 layer compression bandaging

Exclusion Criteria:

  1. Wound infection either acute or chronic
  2. History of significant haematological disorders or DVT with the preceding six months
  3. Pregnant
  4. Pacemakers or implantable defibrillators
  5. Use of any other neuro-modulation device
  6. Current use of TENS in pelvic region, back or legs
  7. Use of investigational drug or device within the past 4 weeks that may interfere with this study
  8. Recent surgery that may affect the study (such as abdominopelvic, or lower limb) in the opinion of the investigator.
  9. Recent trauma to the lower limbs
  10. Size of leg incompatible with the geko™ device.
  11. Obesity (BMI > 34)
  12. Any medication deemed to be significant by the Investigator
  13. Subjects who had an index venous leg ulcer greater in maximum diameter than 10cm in any one dimension, or less than 2cm.
  14. Diabetes
  15. Clinical evidence of peripheral arterial disease (i.e signs or symptoms, in the opinion of the researcher)

Sites / Locations

  • The University of Manchester Academic Surgery Unit 2nd Floor, ERC University Hospital of South Manchester M23 9LT

Arms of the Study

Arm 1

Arm Type

Experimental

Arm Label

geko device arm

Arm Description

Outcomes

Primary Outcome Measures

The acute effect of the geko™ device on ambulatory venous pressure in patients with venous leg ulcers will be evaluated when sitting, standing or supine
using Lectromed Multitrace II venous pressure recording system, this will measure Ambulatory venous pressure which will show any influence, if any, gekoTM has on AVP.

Secondary Outcome Measures

The acute effect of the geko™ device on lower leg venous transit times
Using an ultrasound contrast agent to detect venous flow using Ultrasound imaging. Ultrasound images will be produced and a comparison of results between baseline and using geko™ device will be assessed.
The acute effect of the geko™ device on wound tissue oxygen levels
The patient will have multipsectral images taken of the ulcer using a fixed camera. The outcome measures (proportions of deoxy- and oxyhaemoglobin) will be displayed on an attached PC.
The effect of the geko™ device on lower leg microcirculation
Laser Speckle contrast imaging will be applied to record images at baseline and with geko™ device
Adverse events assessments
Patients will be monitored for adverse events throughout the duration of the study. Adverse events may be spontaneously reported by the subject, observed by the study personnel. Serious Adverse Events will be reported to the Sponsor, the National Research Ethics Service (NRES) recognised Research Ethics Committee.

Full Information

First Posted
August 17, 2016
Last Updated
May 20, 2022
Sponsor
Firstkind Ltd
search

1. Study Identification

Unique Protocol Identification Number
NCT02884323
Brief Title
A Study in Patients With Venous Leg Ulcers and Measuring the Effects of Using Geko™ Device
Official Title
A Single Centre Open Label Pilot Study Measuring Lower Limb Physiology in Patients With Venous Leg Ulcers Using the Geko™ T-2 or gekoTM Plus [R-2] Neuromuscular Electro Stimulation Device
Study Type
Interventional

2. Study Status

Record Verification Date
May 2022
Overall Recruitment Status
Completed
Study Start Date
August 2016 (Actual)
Primary Completion Date
July 2, 2018 (Actual)
Study Completion Date
July 2, 2018 (Actual)

3. Sponsor/Collaborators

Responsible Party, by Official Title
Sponsor
Name of the Sponsor
Firstkind Ltd

4. Oversight

Data Monitoring Committee
No

5. Study Description

Brief Summary
This is a single centre open label study measuring lower limb physiology in patients with venous leg ulcers at the University Hospital of South Manchester. Ambulatory venous pressure, venous transit times, wound bed tissue oxygenation and changes in microcirculation will be measured at baseline after the gekoTM device is activated. Ambulatory venous pressure and venous transit times will be performed whilst the participant is standing, sitting and supine

6. Conditions and Keywords

Primary Disease or Condition Being Studied in the Trial, or the Focus of the Study
Venous Leg Ulcer

7. Study Design

Primary Purpose
Other
Study Phase
Not Applicable
Interventional Study Model
Single Group Assignment
Masking
None (Open Label)
Allocation
N/A
Enrollment
7 (Actual)

8. Arms, Groups, and Interventions

Arm Title
geko device arm
Arm Type
Experimental
Intervention Type
Device
Intervention Name(s)
geko™ device
Intervention Description
The geko™ (T-2 and R-2) devices are small disposable, internally powered, neuromuscular stimulators that are applied externally to the leg.
Primary Outcome Measure Information:
Title
The acute effect of the geko™ device on ambulatory venous pressure in patients with venous leg ulcers will be evaluated when sitting, standing or supine
Description
using Lectromed Multitrace II venous pressure recording system, this will measure Ambulatory venous pressure which will show any influence, if any, gekoTM has on AVP.
Time Frame
2 hours
Secondary Outcome Measure Information:
Title
The acute effect of the geko™ device on lower leg venous transit times
Description
Using an ultrasound contrast agent to detect venous flow using Ultrasound imaging. Ultrasound images will be produced and a comparison of results between baseline and using geko™ device will be assessed.
Time Frame
2 hours
Title
The acute effect of the geko™ device on wound tissue oxygen levels
Description
The patient will have multipsectral images taken of the ulcer using a fixed camera. The outcome measures (proportions of deoxy- and oxyhaemoglobin) will be displayed on an attached PC.
Time Frame
2 hours
Title
The effect of the geko™ device on lower leg microcirculation
Description
Laser Speckle contrast imaging will be applied to record images at baseline and with geko™ device
Time Frame
2 hours
Title
Adverse events assessments
Description
Patients will be monitored for adverse events throughout the duration of the study. Adverse events may be spontaneously reported by the subject, observed by the study personnel. Serious Adverse Events will be reported to the Sponsor, the National Research Ethics Service (NRES) recognised Research Ethics Committee.
Time Frame
2 hours

10. Eligibility

Sex
All
Minimum Age & Unit of Time
18 Years
Maximum Age & Unit of Time
99 Years
Accepts Healthy Volunteers
No
Eligibility Criteria
Inclusion Criteria: Age ≥ 18 years Intact healthy skin at the site of device application Able to understand the Patient Information Sheet Willing and able to give informed consent Willing and able to follow the requirements of the protocol Subjects who had a chronic venous leg ulcer (i.e. CEAP classification of C6 1) greater than 1 cm2 and less than 10 cm in maximum diameter, ABPI of ≥0.8 Patient treated with 4 layer compression bandaging Exclusion Criteria: Wound infection either acute or chronic History of significant haematological disorders or DVT with the preceding six months Pregnant Pacemakers or implantable defibrillators Use of any other neuro-modulation device Current use of TENS in pelvic region, back or legs Use of investigational drug or device within the past 4 weeks that may interfere with this study Recent surgery that may affect the study (such as abdominopelvic, or lower limb) in the opinion of the investigator. Recent trauma to the lower limbs Size of leg incompatible with the geko™ device. Obesity (BMI > 34) Any medication deemed to be significant by the Investigator Subjects who had an index venous leg ulcer greater in maximum diameter than 10cm in any one dimension, or less than 2cm. Diabetes Clinical evidence of peripheral arterial disease (i.e signs or symptoms, in the opinion of the researcher)
Overall Study Officials:
First Name & Middle Initial & Last Name & Degree
Charles McCollum
Organizational Affiliation
UHSM
Official's Role
Principal Investigator
Facility Information:
Facility Name
The University of Manchester Academic Surgery Unit 2nd Floor, ERC University Hospital of South Manchester M23 9LT
City
Manchester
ZIP/Postal Code
M23 9LT
Country
United Kingdom

12. IPD Sharing Statement

Plan to Share IPD
Yes

Learn more about this trial

A Study in Patients With Venous Leg Ulcers and Measuring the Effects of Using Geko™ Device

We'll reach out to this number within 24 hrs