Detecting Neonatal Hypoglycemia Using Real-Time Continuous Glucose Monitoring (CGM)

Primary Purpose

Neonatal Hypoglycemia

Status
Completed
Phase
Not Applicable
Locations
United States
Study Type
Interventional
Intervention
Standard of care glucose test
Sponsored by
Stanford University
About
Eligibility
Locations
Arms
Outcomes
Full info

About this trial

This is an interventional diagnostic trial for Neonatal Hypoglycemia

Eligibility Criteria

undefined - 7 Days (Child)All SexesDoes not accept healthy volunteers

Inclusion Criteria:

  • Infants who are at least 34 weeks gestation that are born to mothers with gestational or pre-gestational diabetes and are admitted to LPCH are eligible for the study.

Exclusion Criteria:

  • Infants <2,000 grams will be excluded from the study. Infants will also be excluded if they have an anomaly of the skin or subcutaneous tissue that would prevent proper adhesion, placement, and function of the sensor.

Sites / Locations

  • Stanford University

Arms of the Study

Arm 1

Arm 2

Arm Type

Experimental

No Intervention

Arm Label

Remote Monitoring CGM Group

Blinded CGM Group

Arm Description

Participants wear a CGM that is blinded at bedside (to participant and clinical staff) but remotely monitored by study staff. If a blood sugar less than 46 mg/dl occurs, the study staff receive a notification and ask the clinical staff to perform a confirmation standard of care glucose test.

Participants wear a blinded CGM during the study period. Values are blinded to study staff, participant, and clinical staff.

Outcomes

Primary Outcome Measures

Sensor-detected Hypoglycemia
Reported values in the table represent the cumulative number of hypoglycemic events detected by the sensor that were not detected by the hospital standard of care measures across all participants.

Secondary Outcome Measures

Sensitivity of the CGM to Detect Hypoglycemia.
True positive rate.
Specificity of CGM to Detect Hypoglycemic Events
True negative rate

Full Information

First Posted
January 24, 2017
Last Updated
July 26, 2019
Sponsor
Stanford University
search

1. Study Identification

Unique Protocol Identification Number
NCT03032523
Brief Title
Detecting Neonatal Hypoglycemia Using Real-Time Continuous Glucose Monitoring (CGM)
Official Title
Detecting Neonatal Hypoglycemia Using Real-Time Continuous Glucose Monitoring (CGM)
Study Type
Interventional

2. Study Status

Record Verification Date
July 2019
Overall Recruitment Status
Completed
Study Start Date
October 1, 2016 (Actual)
Primary Completion Date
April 1, 2018 (Actual)
Study Completion Date
April 1, 2018 (Actual)

3. Sponsor/Collaborators

Responsible Party, by Official Title
Principal Investigator
Name of the Sponsor
Stanford University

4. Oversight

Data Monitoring Committee
No

5. Study Description

Brief Summary
Hypoglycemia is the most common metabolic problem faced after birth. The investigators will be studying the utility of using a continuous glucose monitoring(CGM) system to more closely monitor low blood sugars in newborns. The investigators will evaluate the number of hypoglycemic events detected using CGM and compare it to those detected using current standard of care screening methods.
Detailed Description
A CGM will be subcutaneously inserted by trained staff on a healthy area of skin and will be calibrated according to the manufacturer's instructions. Blood glucose measurements will be taken using a blinded study glucometer to calibrate the device. Calibration by trained study staff will take place about every 12 hours. Sensor insertion sites will be monitored for infection throughout the course of the study by nursing and clinical staff or by trained study staff on an as needed basis. At the conclusion of the study, the CGM will be removed and assessed for signs of infection. Study duration will be up to 7 days while the patient is admitted to the hospital. Participants will be randomized into 2 groups. The control group will have a blinded CGM in place for the duration of the study. The remote monitoring group will be blinded to clinical staff. This group will have a CGM connected to an iPod that sends continuous glucose data to the study phone and will be monitored 24/7 by study staff. If a blood sugar level of <46 mg/dl is detected, the infant will first be evaluated for positioning that could be causing a falsely low value. If the infant is re-positioned and CGM continues to show a blood sugar level of <46 mg/dl, study staff will prompt the nurse taking care of the patient to obtain a capillary glucose value to verify the low blood sugar and treat it as deemed appropriate by the clinical team. The investigators will evaluate the number of hypoglycemic events that occur in the blinded CGM group versus the number that occur in the remote monitoring group to assess if the CGM is able to more sensitively detect low blood sugars in infants than current hospital standard of care measures.

6. Conditions and Keywords

Primary Disease or Condition Being Studied in the Trial, or the Focus of the Study
Neonatal Hypoglycemia

7. Study Design

Primary Purpose
Diagnostic
Study Phase
Not Applicable
Interventional Study Model
Parallel Assignment
Masking
ParticipantCare ProviderOutcomes Assessor
Allocation
Randomized
Enrollment
21 (Actual)

8. Arms, Groups, and Interventions

Arm Title
Remote Monitoring CGM Group
Arm Type
Experimental
Arm Description
Participants wear a CGM that is blinded at bedside (to participant and clinical staff) but remotely monitored by study staff. If a blood sugar less than 46 mg/dl occurs, the study staff receive a notification and ask the clinical staff to perform a confirmation standard of care glucose test.
Arm Title
Blinded CGM Group
Arm Type
No Intervention
Arm Description
Participants wear a blinded CGM during the study period. Values are blinded to study staff, participant, and clinical staff.
Intervention Type
Diagnostic Test
Intervention Name(s)
Standard of care glucose test
Intervention Description
If the CGM in the remote monitoring group detects a blood sugar less than 46mg/dl, a confirmatory standard of care glucose test will be performed to confirm the low blood sugar.
Primary Outcome Measure Information:
Title
Sensor-detected Hypoglycemia
Description
Reported values in the table represent the cumulative number of hypoglycemic events detected by the sensor that were not detected by the hospital standard of care measures across all participants.
Time Frame
up to 8 days
Secondary Outcome Measure Information:
Title
Sensitivity of the CGM to Detect Hypoglycemia.
Description
True positive rate.
Time Frame
up to 7 days
Title
Specificity of CGM to Detect Hypoglycemic Events
Description
True negative rate
Time Frame
up to 7 days

10. Eligibility

Sex
All
Maximum Age & Unit of Time
7 Days
Accepts Healthy Volunteers
No
Eligibility Criteria
Inclusion Criteria: Infants who are at least 34 weeks gestation that are born to mothers with gestational or pre-gestational diabetes and are admitted to LPCH are eligible for the study. Exclusion Criteria: Infants <2,000 grams will be excluded from the study. Infants will also be excluded if they have an anomaly of the skin or subcutaneous tissue that would prevent proper adhesion, placement, and function of the sensor.
Overall Study Officials:
First Name & Middle Initial & Last Name & Degree
Laura Nally, MD
Organizational Affiliation
Stanford University
Official's Role
Principal Investigator
Facility Information:
Facility Name
Stanford University
City
Stanford
State/Province
California
ZIP/Postal Code
94305
Country
United States

12. IPD Sharing Statement

Plan to Share IPD
Undecided

Learn more about this trial

Detecting Neonatal Hypoglycemia Using Real-Time Continuous Glucose Monitoring (CGM)