Wearable Sensor for Responsive DBS for ET
Primary Purpose
Essential Tremor
Status
Completed
Phase
Not Applicable
Locations
United States
Study Type
Interventional
Intervention
Responsive deep brain stimulation
Sponsored by
About this trial
This is an interventional treatment trial for Essential Tremor
Eligibility Criteria
Inclusion Criteria:
- Provide informed consent
- Patient is over 21 years of age
- Patient has had a significant disabling, medication-refractory upper extremity tremor with no evidence of non-ET central nervous system disease or injury for at least three (3) months prior to implantation of Activa SC, PC, or RC device.
- Patient receives Vim electrode and Activa SC, PC or RC device implants, and recovers fully after surgery.
- Patient is available for study participation after their clinical programming appointments for six months.
Exclusion Criteria:
- Medication related movement disorders.
- Any suspicion of Parkinsonian tremor, including presence of Parkinsonian features such as bradykinesia, rigidity, or postural instability.
- Severe medical co-morbidity including cardiovascular disorder, lung disorder, kidney disease, continuous neurological disease, hematological disease, or frailty that impact tolerability of the surgery as judged by the screening physicians.
- Patient is undergoing a lead revision surgery.
Sites / Locations
- UF Health
- Biomedical Sciences Building
Arms of the Study
Arm 1
Arm Type
Experimental
Arm Label
Subjects with Essential Tremor
Arm Description
This cohort will receive deep brain stimulation (DBS) therapy responsively based on the level of their symptoms as detected by wearable EMG and inertia (acceleration) sensors.
Outcomes
Primary Outcome Measures
Clinical Rating Scale for Tremor (CRST)
Responsive deep brain stimulation as an effective alternative to continuous deep brain stimulation. Clinical Tremor Rating Scale (TRS), rated by a blinded neurologist, during responsive brain stimulation will be compared to scores during continuous deep brain stimulation and no stimulation. The minimum and maximum score range for this scale is 0-80, with higher score indicating worse outcome.
Secondary Outcome Measures
Full Information
NCT ID
NCT03051178
First Posted
February 9, 2017
Last Updated
October 27, 2022
Sponsor
University of Florida
Collaborators
Medtronic, De Luca Foundation, National Institute of Neurological Disorders and Stroke (NINDS)
1. Study Identification
Unique Protocol Identification Number
NCT03051178
Brief Title
Wearable Sensor for Responsive DBS for ET
Official Title
Wearable Sensor Driven Closed-loop Deep Brain Stimulation for Essential Tremor
Study Type
Interventional
2. Study Status
Record Verification Date
October 2022
Overall Recruitment Status
Completed
Study Start Date
September 18, 2018 (Actual)
Primary Completion Date
September 29, 2021 (Actual)
Study Completion Date
September 29, 2021 (Actual)
3. Sponsor/Collaborators
Responsible Party, by Official Title
Sponsor
Name of the Sponsor
University of Florida
Collaborators
Medtronic, De Luca Foundation, National Institute of Neurological Disorders and Stroke (NINDS)
4. Oversight
Studies a U.S. FDA-regulated Drug Product
No
Studies a U.S. FDA-regulated Device Product
Yes
Product Manufactured in and Exported from the U.S.
No
Data Monitoring Committee
Yes
5. Study Description
Brief Summary
The purpose of this study is evaluate the effectiveness and safety of a possible new treatment for Essential Tremor (ET) using external wearable sensors, which have the capability of recording acceleration and Electromyography (EMG). This therapy is called Responsive Deep Brain Stimulation (R-DBS). R-DBS systems will communicate with a computer, and apply stimulation when the computer detects patterns associated with tremor. This detection will suppress pathological activity and improve or alleviate the tremor.
Currently, DBS is approved for the treatment of ET; however, stimulation is delivered continuously even when tremor or other symptoms are absent. Continuous DBS can lead to unwanted side effects such as stuttering and gait\balance problems. On the other hand, R-DBS will turn on only if activity associated with ET from the external sensors is detected.
Detailed Description
The overall purpose of this application is to capture pathological activity related to essential tremor using external wearable sensors to responsively initiate or terminate DBS. To this end, the researchers propose to use the Nexus-D system, which requires a firm ware update to an Activa Implantable Neurostimulator (INS), and it will in a smart way turn DBS on/off in patients. The study team will recruit subjects with Activa SC or PC neurostimulator implants during 6 post-operative programming visits. The research group is already familiar with and is in possession of the Nexus-D system, and the investigators have successfully performed responsive DBS in two patients with Tourette syndrome (TS) and in four patients with Parkinson's disease in acute settings. The lab is also equipped with wireless wearable sensor and amplifier systems, such as a 16-unit wireless EMG+ acceleration+inertia Trigno Wireless Bio Acquisition System (Delsys Inc, Natick, MA). The study team aims to combine these signal modalities to capture pathological symptoms and generate commands to initiate or terminate DBS (also record adverse side effects, if any). The project goal is to characterize the clinical efficacy, side effect profile, and battery life of closed-loop DBS in acute settings using wearable sensors in essential tremor patients.
6. Conditions and Keywords
Primary Disease or Condition Being Studied in the Trial, or the Focus of the Study
Essential Tremor
7. Study Design
Primary Purpose
Treatment
Study Phase
Not Applicable
Interventional Study Model
Single Group Assignment
Masking
None (Open Label)
Allocation
N/A
Enrollment
17 (Actual)
8. Arms, Groups, and Interventions
Arm Title
Subjects with Essential Tremor
Arm Type
Experimental
Arm Description
This cohort will receive deep brain stimulation (DBS) therapy responsively based on the level of their symptoms as detected by wearable EMG and inertia (acceleration) sensors.
Intervention Type
Device
Intervention Name(s)
Responsive deep brain stimulation
Intervention Description
Responsive deep brain stimulation (R-DBS) therapy will be delivered responsively based on the level of their symptoms as detected by wearable EMG and inertia (acceleration) sensors.
Primary Outcome Measure Information:
Title
Clinical Rating Scale for Tremor (CRST)
Description
Responsive deep brain stimulation as an effective alternative to continuous deep brain stimulation. Clinical Tremor Rating Scale (TRS), rated by a blinded neurologist, during responsive brain stimulation will be compared to scores during continuous deep brain stimulation and no stimulation. The minimum and maximum score range for this scale is 0-80, with higher score indicating worse outcome.
Time Frame
30 minutes during one monthly visit after clinical continuous deep brain stimulation is optimized.
10. Eligibility
Sex
All
Minimum Age & Unit of Time
21 Years
Maximum Age & Unit of Time
90 Years
Accepts Healthy Volunteers
No
Eligibility Criteria
Inclusion Criteria:
Provide informed consent
Patient is over 21 years of age
Patient has had a significant disabling, medication-refractory upper extremity tremor with no evidence of non-ET central nervous system disease or injury for at least three (3) months prior to implantation of Activa SC, PC, or RC device.
Patient receives Vim electrode and Activa SC, PC or RC device implants, and recovers fully after surgery.
Patient is available for study participation after their clinical programming appointments for six months.
Exclusion Criteria:
Medication related movement disorders.
Any suspicion of Parkinsonian tremor, including presence of Parkinsonian features such as bradykinesia, rigidity, or postural instability.
Severe medical co-morbidity including cardiovascular disorder, lung disorder, kidney disease, continuous neurological disease, hematological disease, or frailty that impact tolerability of the surgery as judged by the screening physicians.
Patient is undergoing a lead revision surgery.
Overall Study Officials:
First Name & Middle Initial & Last Name & Degree
Aysegul Gunduz, PhD
Organizational Affiliation
University of Florida
Official's Role
Principal Investigator
Facility Information:
Facility Name
UF Health
City
Gainesville
State/Province
Florida
ZIP/Postal Code
32610
Country
United States
Facility Name
Biomedical Sciences Building
City
Gainesville
State/Province
Florida
ZIP/Postal Code
32611
Country
United States
12. IPD Sharing Statement
Plan to Share IPD
Undecided
Learn more about this trial