Trial on Safety & Performance of TAXUS Element vs. XIENCE Prime Stent in Treatment of Coronary Lesion in Diabetics (Tuxedo)

Primary Purpose

Type 2 Diabetes, Coronary Heart Disease

Status
Completed
Phase
Not Applicable
Locations
India
Study Type
Interventional
Intervention
TAXUS Element™ Paclitaxel-Eluting Stent System
Xience PRIME Everolimus-Eluting Stent System
Sponsored by
Fortis Escorts Heart Institute
About
Eligibility
Locations
Arms
Outcomes
Full info

About this trial

This is an interventional treatment trial for Type 2 Diabetes focused on measuring coronary artery disease, diabetes mellitus, everolimus, paclitaxel stents

Eligibility Criteria

18 Years - undefined (Adult, Older Adult)All SexesDoes not accept healthy volunteers

Inclusion Criteria:

CI1. Patient must have a diagnosis of diabetes mellitus (Type 1 or Type 2) defined according to the American Diabetes Association as history of one of the followings :

  1. Two hour plasma glucose >200 mg/dL (11.1 mmol/L) following a 75g oral glucose tolerance test
  2. Random plasma glucose >200 mg/dL 3. A fasting plasma glucose level >126 mg/dL (7.0 mmol/L)

4. Elevated HbA1c level 6.5 And currently undergoing pharmacological treatment 5.Patients admitted with ACS NSTEMI and HbA1c > 7 can be included even if they were not on pharmacological treatment. CI2. Patient (or legal guardian) understands the trial requirements and the treatment procedures and provides written informed consent before any trial-specific tests or procedures are performed CI3. Patient is eligible for percutaneous coronary intervention (PCI) CI4. Patient has symptomatic coronary artery disease or documented silent ischemia. CI5. Patient is willing to comply with all protocol-required follow-up evaluations.

Angiographic Inclusion Criteria (visual estimate)

AI1. Target lesion must be a de novo lesion located in a native coronary artery with a visually estimated reference vessel diameter (RVD) 2.25 mm and 4.0 mm. Treatment of up to 3 de novo target lesions is allowed with a maximum of two denovo target lesions per epicardial vessel.

AI2. Target lesion length must measure 34 mm (by visual estimate) AI3. Target lesion must be in a major coronary artery or branch with visually estimated stenosis 50% and <100% with Thrombolysis in Myocardial Infarction (TIMI) flow 1. AI4. If more than one target lesion will be treated, the RVD and lesion length of each must meet the above criteria. AI5. Non-study percutaneous intervention for lesions in a target vessel (including side branches) is allowed if performed 9 months prior to the index procedure. AI6. Non study percutaneous interventions for lesions in a non target vessel are allowed in the following circumstances:

  1. Unsuccessful, or complicated bare metal stent, balloon dilatation, cutting balloon, atherectomy, thrombectomy, and laser treatments are allowed if performed 30 days prior to the index procedure.
  2. Drug-eluting stent treatment is permitted if performed 90 days prior to index procedure. AI7. Non study, percutaneous interventions for lesion(s) in a target vessel (including side branches) or non-target vessel are allowed if performed 9 months after the index procedure.

Exclusion Criteria:

CE1. Patient has known allergy to the study stent system or protocol-required concomitant medications (e.g., stainless steel, platinum, chromium, nickel, iron, thienopyridines, aspirin, radiographic contrast medium) that cannot be adequately pre-medicated. CE2. Patient has any other serious medical illness (e.g., cancer, congestive heart failure) that may reduce life expectancy to less than 12 months CE3. Acute or chronic renal dysfunction (creatinine > 2.0 mg/dl or 177 μmol/l) CE4. Currently participating in another investigational drug or device study

Angiographic Exclusion Criteria (visual estimate)

AE1. Target lesion meets any of the following criteria:

  • Left main location including left main ostial location
  • Located within 2 mm of the origin of the left anterior descending (LAD) coronary artery or left circumflex (LCX) coronary artery by visual estimate
  • Located within a saphenous vein graft or an arterial graft or distal to a diseased arterial or saphenous vein graft. Diseased graft defined as irregularity per angiogram and any visually estimated diameter stenosis > 20%.
  • Involves a bifurcation in which the side branch 2.0 mm in diameter AND the ostium of the side branch is > 50% stenosed by visual estimate.
  • Involves a side branch requiring pre-dilatation
  • TIMI flow 0 (total occlusion) prior to guide wire crossing
  • Excessive tortuosity proximal to or within the lesion
  • Extreme angulation ( ≥90°) proximal to or within the lesion
  • Target lesion and/or target vessel proximal to the target lesion is moderately to severely calcified by visual estimate
  • Restenotic from previous intervention
  • Thrombus, or possible thrombus, present in the target vessel AE2. Patient has an additional clinically significant lesion(s) in the target vessel for which an intervention within 9 months after the index procedure may be required

Sites / Locations

  • Fortis Escorts Heart Institute

Arms of the Study

Arm 1

Arm 2

Arm Type

Experimental

Active Comparator

Arm Label

TAXUS Element™ Paclitaxel-Eluting System

XIENCE PRIME™ ™ Everolimus-Eluting Stent System

Arm Description

The TAXUS® Element™ stent system is a multifunctional device providing a mechanical structure for vascular lumen support and a pharmacological agent targeted toward reducing or preventing the incidence of restenosis. The TAXUS Element™ stent is a balloon expandable, stainless steel platinum alloy stent, coated with paclitaxel in a slow-release system, pre-mounted on a high-pressure Monorail delivery catheter and is intended for use in the treatment of coronary artery disease. The pharmacological agent, paclitaxel, is incorporated into a triblock polymer matrix and applied to the surface of the stent. The polymer matrix provides controlled release of available paclitaxel. The TAXUS Element™ stent design is built upon the TAXUS Express and TAXUS Liberte design experience, but incorporates several improved stent design characteristics. The TAXUS Element™ stent also has a smaller tip profile, designed to enhance the ability to cross tighter and/or more complex lesions.

The everolimus-eluting stent (EES, manufactured and distributed by Abbott Vascular, Santa Clara, CA, as XIENCE PRIME™ ) is a balloon expandable stent manufactured from a flexible cobalt chromium alloy with a multicellular design and 0.0032-in strut thickness which is coated with a thin (7.8 μm) nonadhesive, durable, biocompatible acrylic polymer and fluorinated copolymer releasing everolimus. Everolimus [40-O-(2-hydroxyethyl)- rapamycin], a semisynthetic macrolide immunosuppressant, inhibits growth factor-stimulated cell proliferation by causing cell-cycle arrest in the late G1 stage, thereby suppressing neointimal formation. Comparative analysis in an in vivo rabbit aortoiliac model has shown more rapid endothelialization with the EES compared to SES, PES, and ZES.

Outcomes

Primary Outcome Measures

Composite safety endpoint of Target Vessel Failure (TVF) rate at 12 months post-index procedure: • Cardiac Death related to target vessel • Target Vessel Myocardial Infarction (TV-MI) • Target Vessel Revascularization (TVR)
TVS is defined as any ischemia-driven revascularization of the target vessel( TVR), MI (Q-wave and non-Q-wave) related to the target vessel, or cardiac death related to the target vessel.

Secondary Outcome Measures

Target Lesion Revascularization (TLR) TVF rate (primary endpoint 1 year) Target Vessel Revascularization rate Target Lesion Revascularization Composite of cardiac death or target vessel
Ischemia Driven Target Lesion Revascularization (TLR) Rate TVF rate (primary endpoint 1 year) Target Vessel Revascularization rate Target Lesion Revascularization Composite of cardiac death or target vessel
Target Vessel Failure (TVF)
Ischemia Driven Target Vessel Revascularization (TVR)
Target Lesion Failure Rate
Target Lesion Failure Rate defined as any ischemia-driven revascularization of the target lesion (TLR), MI (Q-wave and non-Q-wave) related to the target vessel, or cardiac death related to the target vessel
Myocardial Infarction(MI) rate
Q-wave and Non-Q-wave, cumulative and individual
Cardiac death rate
Non-Cardiac death rate
All death or MI rate
All Death / MI / TVR Rate
Major Adverse Cardiac Event (MACE)
MACE defined as a composite of death, MI (Q-wave and non-Q-wave), emergent coronary artery bypass surgery (CABG), or target lesion revascularization (TLR) by repeat PTCA, or CABG.
Stent Thrombosis Rate
Stent thrombosis(ST) rate defined using ARC definition of definite and probable stent thrombosis and categorized as early, late or very late.

Full Information

First Posted
September 2, 2015
Last Updated
April 21, 2017
Sponsor
Fortis Escorts Heart Institute
Collaborators
Boston Scientific Corporation, Max Neeman Medical International Ltd.
search

1. Study Identification

Unique Protocol Identification Number
NCT03125772
Brief Title
Trial on Safety & Performance of TAXUS Element vs. XIENCE Prime Stent in Treatment of Coronary Lesion in Diabetics
Acronym
Tuxedo
Official Title
A Prospective, Single Blind, Multi-center, Randomized Trial to Compare the TAXUS Element™ Coronary Stent System Against the XIENCE Prime™ Coronary Stent System in the Treatment of a Diabetic Patient PopulatiOn in India
Study Type
Interventional

2. Study Status

Record Verification Date
April 2017
Overall Recruitment Status
Completed
Study Start Date
June 2011 (undefined)
Primary Completion Date
May 2015 (Actual)
Study Completion Date
May 2016 (Actual)

3. Sponsor/Collaborators

Responsible Party, by Official Title
Principal Investigator
Name of the Sponsor
Fortis Escorts Heart Institute
Collaborators
Boston Scientific Corporation, Max Neeman Medical International Ltd.

4. Oversight

Data Monitoring Committee
Yes

5. Study Description

Brief Summary
The TUXEDO-India is a prospective, single blind, multi-center randomized clinical trial to assess the TAXUS Element™ in a consecutive population of diabetic patients with coronary artery disease undergoing coronary revascularization. Approximately 1,830 patients with single or multi lesion, multi vessel coronary artery or saphenous vein graft disease ranging in vessels ranging from 2.25 mm to 4.0 mm in diameter by visual estimate will be enrolled in a 1:1 randomization to TAXUS Element™ vs. XIENCE™ Prime in India at up to 50 clinical sites, to demonstrate the safety and effectiveness of TAXUS Element™ in an unrestricted population. Procedural Endpoints: Device success, defined as attainment of < 30% residual stenosis of the target lesion (visual assessment) using the TAXUS Element™ or XIENCE™ Prime stent. Lesion success defined as attainment of < 30% residual stenosis (visual assessment) using any percutaneous method. Procedure success defined as lesion success without the occurrence of in-hospital MACE. Procedure complication rate including composite and individual angiographic occurrence of dissection ≥B, distal embolization, no reflow, slow flow, abrupt closure, or perforation.
Detailed Description
Primary Endpoint: Composite safety endpoint of Target Vessel Failure (TVF) rate at 12 months post-index procedure: Cardiac Death related to target vessel Target Vessel Myocardial Infarction (TV-MI) Target Vessel Revascularization (TVR) Secondary Endpoint: Clinical endpoints measured at 30, 180 days, and 1 and 2 years post index procedure: TVF rate (primary endpoint 1 year) Target Vessel Revascularization (TVR) rate Target Lesion Revascularization (TLR) Composite of cardiac death or target vessel MI Composite of all deaths, all MI, all revascularizations Major Adverse Cardiac Events (MACE) which is the composite endpoint of cardiac death, all myocardial infarction, and TLR MI (Q-wave and non-Q-wave) rate Cardiac death rate Non-cardiac death rate All death rate Cardiac death or MI rate All death or MI rate Stent thrombosis rate (definite or probable by Academic Research Consortium [ARC] definitions) Periprocedural endpoints: Technical success rate Clinical procedural success rate Anti-platelet Therapy A loading dose of either Clopidogrel (300mg, 600mg recommended), Ticlopidine (500mg), or Prasugrel (60mg) must be given to the patient prior to index procedure. Thereafter, Clopidogrel (75mg daily), Ticlopidine (250mg twice daily), Prasugrel (10mg) must be given for at least 12 months after stent implantation. If the protocol mandated (loading and or daily) dosage conflicts with local DFU, the local DFU should take precedence. Aspirin (ASA): Must be administered concomitantly with Clopidogrel, Ticlopidine or Prasugrel and then continued indefinitely Sample Size Parameters: The expected 12 month TVF rate for both groups is estimated to be 8.4% based on the data available from the SPIRIT IV trial. Given the non-inferiority margin (delta) of 4% with equal expected means and a one-sided 5% significance level, 824 patients in each group will provide at least 90% power to reject the null hypothesis if it is false. When allowance is made for 10% attrition, approximately 915 patients are required per each treatment group. Therefore, the necessary total sample size for the trial is 1,830 patients.

6. Conditions and Keywords

Primary Disease or Condition Being Studied in the Trial, or the Focus of the Study
Type 2 Diabetes, Coronary Heart Disease
Keywords
coronary artery disease, diabetes mellitus, everolimus, paclitaxel stents

7. Study Design

Primary Purpose
Treatment
Study Phase
Not Applicable
Interventional Study Model
Parallel Assignment
Masking
Participant
Allocation
Randomized
Enrollment
1830 (Actual)

8. Arms, Groups, and Interventions

Arm Title
TAXUS Element™ Paclitaxel-Eluting System
Arm Type
Experimental
Arm Description
The TAXUS® Element™ stent system is a multifunctional device providing a mechanical structure for vascular lumen support and a pharmacological agent targeted toward reducing or preventing the incidence of restenosis. The TAXUS Element™ stent is a balloon expandable, stainless steel platinum alloy stent, coated with paclitaxel in a slow-release system, pre-mounted on a high-pressure Monorail delivery catheter and is intended for use in the treatment of coronary artery disease. The pharmacological agent, paclitaxel, is incorporated into a triblock polymer matrix and applied to the surface of the stent. The polymer matrix provides controlled release of available paclitaxel. The TAXUS Element™ stent design is built upon the TAXUS Express and TAXUS Liberte design experience, but incorporates several improved stent design characteristics. The TAXUS Element™ stent also has a smaller tip profile, designed to enhance the ability to cross tighter and/or more complex lesions.
Arm Title
XIENCE PRIME™ ™ Everolimus-Eluting Stent System
Arm Type
Active Comparator
Arm Description
The everolimus-eluting stent (EES, manufactured and distributed by Abbott Vascular, Santa Clara, CA, as XIENCE PRIME™ ) is a balloon expandable stent manufactured from a flexible cobalt chromium alloy with a multicellular design and 0.0032-in strut thickness which is coated with a thin (7.8 μm) nonadhesive, durable, biocompatible acrylic polymer and fluorinated copolymer releasing everolimus. Everolimus [40-O-(2-hydroxyethyl)- rapamycin], a semisynthetic macrolide immunosuppressant, inhibits growth factor-stimulated cell proliferation by causing cell-cycle arrest in the late G1 stage, thereby suppressing neointimal formation. Comparative analysis in an in vivo rabbit aortoiliac model has shown more rapid endothelialization with the EES compared to SES, PES, and ZES.
Intervention Type
Device
Intervention Name(s)
TAXUS Element™ Paclitaxel-Eluting Stent System
Intervention Description
Texus Element is the next generation Boston Scientific paclitexel-eluting coronary sten and received DCGI approval on April 13th, 2010.
Intervention Type
Device
Intervention Name(s)
Xience PRIME Everolimus-Eluting Stent System
Intervention Description
The Everolimus-eluting stent manufactured and distributed by Abbott Vascular Santa Clara, CA, as Xience Prime.
Primary Outcome Measure Information:
Title
Composite safety endpoint of Target Vessel Failure (TVF) rate at 12 months post-index procedure: • Cardiac Death related to target vessel • Target Vessel Myocardial Infarction (TV-MI) • Target Vessel Revascularization (TVR)
Description
TVS is defined as any ischemia-driven revascularization of the target vessel( TVR), MI (Q-wave and non-Q-wave) related to the target vessel, or cardiac death related to the target vessel.
Time Frame
12 Months
Secondary Outcome Measure Information:
Title
Target Lesion Revascularization (TLR) TVF rate (primary endpoint 1 year) Target Vessel Revascularization rate Target Lesion Revascularization Composite of cardiac death or target vessel
Time Frame
Measured at 30,180 days,and 1 and 2 years post index procedure
Title
Ischemia Driven Target Lesion Revascularization (TLR) Rate TVF rate (primary endpoint 1 year) Target Vessel Revascularization rate Target Lesion Revascularization Composite of cardiac death or target vessel
Time Frame
Measured at 30,180 days,and 1 and 2 years post index procedure
Title
Target Vessel Failure (TVF)
Time Frame
Measured at 30,180 days,and 1 and 2 years post index procedure
Title
Ischemia Driven Target Vessel Revascularization (TVR)
Time Frame
Measured at 30,180 days,and 1 and 2 years post index procedure
Title
Target Lesion Failure Rate
Description
Target Lesion Failure Rate defined as any ischemia-driven revascularization of the target lesion (TLR), MI (Q-wave and non-Q-wave) related to the target vessel, or cardiac death related to the target vessel
Time Frame
Measured at 30,180 days,and 1 and 2 years post index procedure
Title
Myocardial Infarction(MI) rate
Description
Q-wave and Non-Q-wave, cumulative and individual
Time Frame
Measured at 30,180 days,and 1 and 2 years post index procedure
Title
Cardiac death rate
Time Frame
Measured at 30,180 days,and 1 and 2 years post index procedure
Title
Non-Cardiac death rate
Time Frame
Measured at 30,180 days,and 1 and 2 years post index procedure
Title
All death or MI rate
Time Frame
Measured at 30,180 days,and 1 and 2 years post index procedure
Title
All Death / MI / TVR Rate
Time Frame
Measured at 30,180 days,and 1 and 2 years post index procedure
Title
Major Adverse Cardiac Event (MACE)
Description
MACE defined as a composite of death, MI (Q-wave and non-Q-wave), emergent coronary artery bypass surgery (CABG), or target lesion revascularization (TLR) by repeat PTCA, or CABG.
Time Frame
Measured at 30,180 days,and 1 and 2 years post index procedure
Title
Stent Thrombosis Rate
Description
Stent thrombosis(ST) rate defined using ARC definition of definite and probable stent thrombosis and categorized as early, late or very late.
Time Frame
Measured at 30,180 days,and 1 and 2 years post index procedure
Other Pre-specified Outcome Measures:
Title
Device Success
Description
Device Success Defined as attainment of <30% residual stenosis of the target lesion (visual assessment) using the TAXUS Element or XIENCE Prime stent.
Time Frame
Baseline
Title
Lesion Success
Description
Lesion success defined as attainment of <30% residual stenosis (visual assessment) uring any percutaneous method
Time Frame
Baseline
Title
Procedure Success
Description
Procedure success defined as lesion success without the occurrence of in-hospital MACE.
Time Frame
Baseline
Title
Procedural complication rate
Description
Procedural complication rate including composite and individual angiographic occurrence of dissection, distal embolization, no reflow, slow flow, abrupt closure, or perforation
Time Frame
Baseline

10. Eligibility

Sex
All
Minimum Age & Unit of Time
18 Years
Accepts Healthy Volunteers
No
Eligibility Criteria
Inclusion Criteria: CI1. Patient must have a diagnosis of diabetes mellitus (Type 1 or Type 2) defined according to the American Diabetes Association as history of one of the followings : Two hour plasma glucose >200 mg/dL (11.1 mmol/L) following a 75g oral glucose tolerance test Random plasma glucose >200 mg/dL 3. A fasting plasma glucose level >126 mg/dL (7.0 mmol/L) 4. Elevated HbA1c level 6.5 And currently undergoing pharmacological treatment 5.Patients admitted with ACS NSTEMI and HbA1c > 7 can be included even if they were not on pharmacological treatment. CI2. Patient (or legal guardian) understands the trial requirements and the treatment procedures and provides written informed consent before any trial-specific tests or procedures are performed CI3. Patient is eligible for percutaneous coronary intervention (PCI) CI4. Patient has symptomatic coronary artery disease or documented silent ischemia. CI5. Patient is willing to comply with all protocol-required follow-up evaluations. Angiographic Inclusion Criteria (visual estimate) AI1. Target lesion must be a de novo lesion located in a native coronary artery with a visually estimated reference vessel diameter (RVD) 2.25 mm and 4.0 mm. Treatment of up to 3 de novo target lesions is allowed with a maximum of two denovo target lesions per epicardial vessel. AI2. Target lesion length must measure 34 mm (by visual estimate) AI3. Target lesion must be in a major coronary artery or branch with visually estimated stenosis 50% and <100% with Thrombolysis in Myocardial Infarction (TIMI) flow 1. AI4. If more than one target lesion will be treated, the RVD and lesion length of each must meet the above criteria. AI5. Non-study percutaneous intervention for lesions in a target vessel (including side branches) is allowed if performed 9 months prior to the index procedure. AI6. Non study percutaneous interventions for lesions in a non target vessel are allowed in the following circumstances: Unsuccessful, or complicated bare metal stent, balloon dilatation, cutting balloon, atherectomy, thrombectomy, and laser treatments are allowed if performed 30 days prior to the index procedure. Drug-eluting stent treatment is permitted if performed 90 days prior to index procedure. AI7. Non study, percutaneous interventions for lesion(s) in a target vessel (including side branches) or non-target vessel are allowed if performed 9 months after the index procedure. Exclusion Criteria: CE1. Patient has known allergy to the study stent system or protocol-required concomitant medications (e.g., stainless steel, platinum, chromium, nickel, iron, thienopyridines, aspirin, radiographic contrast medium) that cannot be adequately pre-medicated. CE2. Patient has any other serious medical illness (e.g., cancer, congestive heart failure) that may reduce life expectancy to less than 12 months CE3. Acute or chronic renal dysfunction (creatinine > 2.0 mg/dl or 177 μmol/l) CE4. Currently participating in another investigational drug or device study Angiographic Exclusion Criteria (visual estimate) AE1. Target lesion meets any of the following criteria: Left main location including left main ostial location Located within 2 mm of the origin of the left anterior descending (LAD) coronary artery or left circumflex (LCX) coronary artery by visual estimate Located within a saphenous vein graft or an arterial graft or distal to a diseased arterial or saphenous vein graft. Diseased graft defined as irregularity per angiogram and any visually estimated diameter stenosis > 20%. Involves a bifurcation in which the side branch 2.0 mm in diameter AND the ostium of the side branch is > 50% stenosed by visual estimate. Involves a side branch requiring pre-dilatation TIMI flow 0 (total occlusion) prior to guide wire crossing Excessive tortuosity proximal to or within the lesion Extreme angulation ( ≥90°) proximal to or within the lesion Target lesion and/or target vessel proximal to the target lesion is moderately to severely calcified by visual estimate Restenotic from previous intervention Thrombus, or possible thrombus, present in the target vessel AE2. Patient has an additional clinically significant lesion(s) in the target vessel for which an intervention within 9 months after the index procedure may be required
Overall Study Officials:
First Name & Middle Initial & Last Name & Degree
Upendra Kaul, M.D
Organizational Affiliation
Fortis Escorts Heart Institute
Official's Role
Principal Investigator
Facility Information:
Facility Name
Fortis Escorts Heart Institute
City
New Delhi
State/Province
Delhi
ZIP/Postal Code
110025
Country
India

12. IPD Sharing Statement

Citations:
Citation
www.crf.org/crf/newsroom/news/news-archive/963-announcing-the-tct-2015-late-breaking-trials-and-first-report-investigations
Results Reference
background
Links:
URL
http://www.ctri.nic.in/Clinicaltrials/pmaindet2.php?trialid=3184&EncHid=&userName=Tuxedo
Description
Clinical Trial Registry by India Council of Medical Research

Learn more about this trial

Trial on Safety & Performance of TAXUS Element vs. XIENCE Prime Stent in Treatment of Coronary Lesion in Diabetics

We'll reach out to this number within 24 hrs