Clinical Investigation of AcrySof® IQ PanOptix™ IOL Model TFNT00
Primary Purpose
Cataract
Status
Completed
Phase
Not Applicable
Locations
United States
Study Type
Interventional
Intervention
AcrySof IQ PanOptix Multifocal IOL
AcrySof Monofocal IOL
Sponsored by
About this trial
This is an interventional treatment trial for Cataract focused on measuring Intraocular lens, IOL
Eligibility Criteria
Inclusion Criteria:
- Diagnosed with bilateral cataracts with planned cataract removal by phacoemulsification with a clear cornea incision
- Able to comprehend and willing to sign informed consent and complete all required postoperative follow-up procedures
- Clear intraocular media other than cataract in both eyes.
- Preoperative keratometric astigmatism of less than 1.0 diopter (D) in both operative eyes.
Exclusion Criteria:
- Clinically significant corneal abnormalities including corneal dystrophy, irregularity, inflammation or edema
- Previous refractive surgery or refractive surgery procedures (including, but not limited to LASIK, astigmatic keratotomy, and limbal relaxing incisions)
- Glaucoma (uncontrolled or controlled with medication)
- Degenerative eye disorders (e.g. macular degeneration or other retinal disorders)
- Pregnant or lactating
- Expected to require a second surgical intervention or retinal laser treatment.
Sites / Locations
- Alcon Investigative Site
- Alcon Investigative Site
- Alcon Investigative Site
- Alcon Investigative Site
- Alcon Investigative Site
- Alcon Investigative Site
- Alcon Investigative Site
- Alcon Investigative Site
- Alcon Investigative Site
- Alcon Investigative Site
- Alcon Investigative Site
- Alcon Investigative Site
Arms of the Study
Arm 1
Arm 2
Arm Type
Experimental
Active Comparator
Arm Label
Multifocal IOL
Monofocal IOL
Arm Description
AcrySof IQ PanOptix Multifocal IOL Model TFNT00 implanted in the capsular bag in the posterior chamber following cataract removal and intended for long-term use over the lifetime of the cataract patient. Both eyes will be implanted (bilateral implantation).
AcrySof Monofocal IOL Model SN60AT implanted in the capsular bag in the posterior chamber following cataract removal and intended for long-term use over the lifetime of the cataract patient. Both eyes will be implanted (bilateral implantation).
Outcomes
Primary Outcome Measures
Mean Photopic Monocular Best Corrected Distance Visual Acuity (4 m)
Visual acuity (VA) was tested monocularly (each eye separately) under photopic (well-lit) conditions using the correction obtained from the manifest refraction and 100% contrast electronic Early Treatment Diabetic Retinopathy Study (ETDRS) charts at a distance of 4 meters (m) from the eye. VA was measured in logarithm of the minimum angle of resolution (logMAR), with 0.02 logMAR increment corresponding to a single letter on an ETDRS chart. A lower numeric value represents better visual acuity. This analysis was prespecified for the first operative eye.
Mean Photopic Monocular Distance Corrected Visual Acuity at Near (40 cm)
VA was tested monocularly under photopic conditions using the manifest refraction adjusted for optical infinity and 100% contrast electronic ETDRS charts at a distance of 40 centimeters (cm) from the eye. Distance corrected visual acuity at near was measured in logMAR, with 0.02 logMAR increment corresponding to a single letter on an ETDRS chart. A lower numeric value represents better visual acuity. This analysis was prespecified for the first operative eye.
Cumulative Rate of Secondary Surgical Interventions (SSI) Related to Optical Properties of the IOL, First Eye
The number of SSI's related to the optical properties of the IOL was calculated from time of implantation up to Month 6. The percentage was calculated as (# of eyes with an SSI related to the optical properties of the IOL) divided by (# of eyes with attempted IOL implantation, successful or aborted after contact with the eye) times 100. SSI's could include, but were not limited to, IOL replacement, IOL explantation, IOL repositioning, refractive laser treatment, paracentesis, vitreous aspirations, iridectomy or laser iridotomy for pupillary block, wound leak repair, and retinal detachment repair. No hypothesis testing was planned for this outcome measure.
Mean Photopic Without Glare Binocular Distance Contrast Sensitivity
Contrast sensitivity (ie, the ability to detect objects by distinguishing them from their background) was assessed binocularly (both eyes together) with the subject's best spectacle correction under photopic (well-lit) conditions at a distance of 8 feet from the eye at spatial frequencies of 3, 6, and 12, and 18 cycles per degree (cpd) using the Vector Vision CSV 1000-HGT without a glare source. Raw scores from contrast sensitivity testing were transformed to log units. Subjects who were unable to see a targeted spatial frequency at any available contrast, including that of the reference patch, were assigned the lowest measurable value. A higher numeric value represents better contrast sensitivity. Hypothesis testing was not planned for this outcome measure.
Mean Photopic With Glare Binocular Distance Contrast Sensitivity
Contrast sensitivity was assessed binocularly with the subject's best spectacle correction under photopic conditions at a distance of 8 feet from the eye at spatial frequencies of 3, 6, and 12, and 18 cpd using the Vector Vision CSV 1000-HGT with a glare source. Raw scores from contrast sensitivity testing were transformed to log units. Subjects who were unable to see a targeted spatial frequency at any available contrast, including that of the reference patch, were assigned the lowest measurable value. A higher numeric value represents better contrast sensitivity. Hypothesis testing was not planned for this outcome measure.
Mean Mesopic Without Glare Binocular Distance Contrast Sensitivity
Contrast sensitivity was assessed binocularly with the subject's best spectacle correction under mesopic (dimly-lit) conditions at a distance of 8 feet from the eye at spatial frequencies of 1.5, 3, 6, and 12 cpd using the Vector Vision CSV 1000-HGT without a glare source. Raw scores from contrast sensitivity testing were transformed to log units. Subjects who were unable to see a targeted spatial frequency at any available contrast, including that of the reference patch, were assigned the lowest measurable value. A higher numeric value represents better contrast sensitivity. Hypothesis testing was not planned for this outcome measure.
Mean Mesopic With Glare Binocular Distance Contrast Sensitivity
Contrast sensitivity was assessed binocularly with the subject's best spectacle correction under mesopic conditions at a distance of 8 feet from the eye at spatial frequencies of 1.5, 3, 6, and 12 cpd using the Vector Vision CSV 1000-HGT with a glare source. Raw scores from contrast sensitivity testing were transformed to log units. Subjects who were unable to see a targeted spatial frequency at any available contrast, including that of the reference patch, were assigned the lowest measurable value. A higher numeric value represents better contrast sensitivity. Hypothesis testing was not planned for this outcome measure.
Secondary Outcome Measures
Mean Photopic Monocular Distance Corrected Visual Acuity at Intermediate (66 cm)
VA was tested monocularly under photopic conditions using the manifest refraction adjusted for optical infinity and 100% contrast electronic ETDRS charts at a distance of 66 cm m from the eye. Monocular distance corrected visual acuity at intermediate was measured in logMAR, with 0.02 logMAR increment corresponding to a single letter on an ETDRS chart. A lower numeric value represents better visual acuity. This analysis was prespecified for the first operative eye.
Proportion of Subjects Who Respond "Never" to Question 1 of the Intraocular Lens Satisfaction (IOLSAT) Questionnaire
The IOLSAT is a patient-reported outcomes questionnaire. Subjects were asked, "Overall, in the past 7 days, how often did you need to wear eyeglasses to see?" The proportion of subjects who respond "Never" is reported as a percentage calculated as (# of subjects responding "Never") divided by (# of subjects with bilateral implantation and concordant, non-missing data) times 100.
Rate of Severe Visual Disturbances as Reported by the Subject Using the Questionnaire for Visual Disturbances (QUVID)
QUVID is a patient-reported outcomes questionnaire that collects responses about visual disturbance. Subjects were asked if they experienced any of the visual disturbances in the past 7 days from when the questionnaire was conducted and to answer about how severe their worst experience was on a scale from 0-4, where 0=none and 4=severe. The percentage of subjects responding "Severe" was calculated as (# of subjects responding "Severe") divided by (# of subjects with bilateral implantation and non-missing data in the specified category) times 100. Hypothesis testing was not planned for this outcome measure.
Rate of Most Bothersome Visual Disturbances as Reported by the Subject Using the QUVID
Subjects were asked if they experienced any of the visual disturbances in the past 7 days from when the questionnaire was conducted and to answer how much the disturbance bothered them on a scale from 0-4, where 0=not bothered at all and 4=bothered very much. The percentage of subjects with most bothersome visual disturbances was calculated as (# of subjects responding "Bothered very much") divided by (# of subjects with bilateral implantation and non-missing data in the specified category) times 100. Hypothesis testing was not planned for this outcome measure.
Full Information
1. Study Identification
Unique Protocol Identification Number
NCT03280108
Brief Title
Clinical Investigation of AcrySof® IQ PanOptix™ IOL Model TFNT00
Official Title
Clinical Investigation of AcrySof® IQ PanOptix™ IOL Model TFNT00
Study Type
Interventional
2. Study Status
Record Verification Date
October 2019
Overall Recruitment Status
Completed
Study Start Date
November 1, 2017 (Actual)
Primary Completion Date
September 27, 2018 (Actual)
Study Completion Date
September 27, 2018 (Actual)
3. Sponsor/Collaborators
Responsible Party, by Official Title
Sponsor
Name of the Sponsor
Alcon Research
4. Oversight
Studies a U.S. FDA-regulated Drug Product
No
Studies a U.S. FDA-regulated Device Product
Yes
Device Product Not Approved or Cleared by U.S. FDA
Yes
5. Study Description
Brief Summary
The purpose of this clinical study is to compare the visual outcomes of the AcrySof IQ PanOptix Multifocal Intraocular Lens (IOL) Model TFNT00 against that of a monofocal lens, the AcrySof Monofocal IOL Model SN60AT, in order to demonstrate comparable distance vision and superior near and intermediate vision.
Detailed Description
Both eyes of a subject must require cataract surgery to qualify for enrollment into this study. Subjects participating in the trial will attend a total of 10 study visits over a 7-month period. Of these 10 visits, 1 is preoperative, 2 are operative, and the remaining 7 are postoperative visits. Primary endpoint data will be collected at the Month 6 (Day 120-180) post second eye implantation visit.
6. Conditions and Keywords
Primary Disease or Condition Being Studied in the Trial, or the Focus of the Study
Cataract
Keywords
Intraocular lens, IOL
7. Study Design
Primary Purpose
Treatment
Study Phase
Not Applicable
Interventional Study Model
Parallel Assignment
Masking
Outcomes Assessor
Allocation
Non-Randomized
Enrollment
250 (Actual)
8. Arms, Groups, and Interventions
Arm Title
Multifocal IOL
Arm Type
Experimental
Arm Description
AcrySof IQ PanOptix Multifocal IOL Model TFNT00 implanted in the capsular bag in the posterior chamber following cataract removal and intended for long-term use over the lifetime of the cataract patient. Both eyes will be implanted (bilateral implantation).
Arm Title
Monofocal IOL
Arm Type
Active Comparator
Arm Description
AcrySof Monofocal IOL Model SN60AT implanted in the capsular bag in the posterior chamber following cataract removal and intended for long-term use over the lifetime of the cataract patient. Both eyes will be implanted (bilateral implantation).
Intervention Type
Device
Intervention Name(s)
AcrySof IQ PanOptix Multifocal IOL
Other Intervention Name(s)
Model TFNT00, AcrySof® IQ PanOptix®
Intervention Description
AcrySof IQ PanOptix Multifocal IOL Model TFNT00 for near, intermediate, and distance vision
Intervention Type
Device
Intervention Name(s)
AcrySof Monofocal IOL
Other Intervention Name(s)
Model SN60AT, AcrySof®
Intervention Description
AcrySof Monofocal IOL Model SN60AT for single vision
Primary Outcome Measure Information:
Title
Mean Photopic Monocular Best Corrected Distance Visual Acuity (4 m)
Description
Visual acuity (VA) was tested monocularly (each eye separately) under photopic (well-lit) conditions using the correction obtained from the manifest refraction and 100% contrast electronic Early Treatment Diabetic Retinopathy Study (ETDRS) charts at a distance of 4 meters (m) from the eye. VA was measured in logarithm of the minimum angle of resolution (logMAR), with 0.02 logMAR increment corresponding to a single letter on an ETDRS chart. A lower numeric value represents better visual acuity. This analysis was prespecified for the first operative eye.
Time Frame
Month 6 (Day 120-180), post second eye implantation
Title
Mean Photopic Monocular Distance Corrected Visual Acuity at Near (40 cm)
Description
VA was tested monocularly under photopic conditions using the manifest refraction adjusted for optical infinity and 100% contrast electronic ETDRS charts at a distance of 40 centimeters (cm) from the eye. Distance corrected visual acuity at near was measured in logMAR, with 0.02 logMAR increment corresponding to a single letter on an ETDRS chart. A lower numeric value represents better visual acuity. This analysis was prespecified for the first operative eye.
Time Frame
Month 6 (Day 120-180), post second eye implantation
Title
Cumulative Rate of Secondary Surgical Interventions (SSI) Related to Optical Properties of the IOL, First Eye
Description
The number of SSI's related to the optical properties of the IOL was calculated from time of implantation up to Month 6. The percentage was calculated as (# of eyes with an SSI related to the optical properties of the IOL) divided by (# of eyes with attempted IOL implantation, successful or aborted after contact with the eye) times 100. SSI's could include, but were not limited to, IOL replacement, IOL explantation, IOL repositioning, refractive laser treatment, paracentesis, vitreous aspirations, iridectomy or laser iridotomy for pupillary block, wound leak repair, and retinal detachment repair. No hypothesis testing was planned for this outcome measure.
Time Frame
Up to Month 6 (Day 120-180), post second eye implantation
Title
Mean Photopic Without Glare Binocular Distance Contrast Sensitivity
Description
Contrast sensitivity (ie, the ability to detect objects by distinguishing them from their background) was assessed binocularly (both eyes together) with the subject's best spectacle correction under photopic (well-lit) conditions at a distance of 8 feet from the eye at spatial frequencies of 3, 6, and 12, and 18 cycles per degree (cpd) using the Vector Vision CSV 1000-HGT without a glare source. Raw scores from contrast sensitivity testing were transformed to log units. Subjects who were unable to see a targeted spatial frequency at any available contrast, including that of the reference patch, were assigned the lowest measurable value. A higher numeric value represents better contrast sensitivity. Hypothesis testing was not planned for this outcome measure.
Time Frame
Month 6 (Day 120-180), post second eye implantation
Title
Mean Photopic With Glare Binocular Distance Contrast Sensitivity
Description
Contrast sensitivity was assessed binocularly with the subject's best spectacle correction under photopic conditions at a distance of 8 feet from the eye at spatial frequencies of 3, 6, and 12, and 18 cpd using the Vector Vision CSV 1000-HGT with a glare source. Raw scores from contrast sensitivity testing were transformed to log units. Subjects who were unable to see a targeted spatial frequency at any available contrast, including that of the reference patch, were assigned the lowest measurable value. A higher numeric value represents better contrast sensitivity. Hypothesis testing was not planned for this outcome measure.
Time Frame
Month 6 (Day 120-180), post second eye implantation
Title
Mean Mesopic Without Glare Binocular Distance Contrast Sensitivity
Description
Contrast sensitivity was assessed binocularly with the subject's best spectacle correction under mesopic (dimly-lit) conditions at a distance of 8 feet from the eye at spatial frequencies of 1.5, 3, 6, and 12 cpd using the Vector Vision CSV 1000-HGT without a glare source. Raw scores from contrast sensitivity testing were transformed to log units. Subjects who were unable to see a targeted spatial frequency at any available contrast, including that of the reference patch, were assigned the lowest measurable value. A higher numeric value represents better contrast sensitivity. Hypothesis testing was not planned for this outcome measure.
Time Frame
Month 6 (Day 120-180), post second eye implantation
Title
Mean Mesopic With Glare Binocular Distance Contrast Sensitivity
Description
Contrast sensitivity was assessed binocularly with the subject's best spectacle correction under mesopic conditions at a distance of 8 feet from the eye at spatial frequencies of 1.5, 3, 6, and 12 cpd using the Vector Vision CSV 1000-HGT with a glare source. Raw scores from contrast sensitivity testing were transformed to log units. Subjects who were unable to see a targeted spatial frequency at any available contrast, including that of the reference patch, were assigned the lowest measurable value. A higher numeric value represents better contrast sensitivity. Hypothesis testing was not planned for this outcome measure.
Time Frame
Month 6 (Day 120-180), post second eye implantation
Secondary Outcome Measure Information:
Title
Mean Photopic Monocular Distance Corrected Visual Acuity at Intermediate (66 cm)
Description
VA was tested monocularly under photopic conditions using the manifest refraction adjusted for optical infinity and 100% contrast electronic ETDRS charts at a distance of 66 cm m from the eye. Monocular distance corrected visual acuity at intermediate was measured in logMAR, with 0.02 logMAR increment corresponding to a single letter on an ETDRS chart. A lower numeric value represents better visual acuity. This analysis was prespecified for the first operative eye.
Time Frame
Month 6 (Day 120-180), post second eye implantation
Title
Proportion of Subjects Who Respond "Never" to Question 1 of the Intraocular Lens Satisfaction (IOLSAT) Questionnaire
Description
The IOLSAT is a patient-reported outcomes questionnaire. Subjects were asked, "Overall, in the past 7 days, how often did you need to wear eyeglasses to see?" The proportion of subjects who respond "Never" is reported as a percentage calculated as (# of subjects responding "Never") divided by (# of subjects with bilateral implantation and concordant, non-missing data) times 100.
Time Frame
Month 6 (Day 120-180), post second eye implantation
Title
Rate of Severe Visual Disturbances as Reported by the Subject Using the Questionnaire for Visual Disturbances (QUVID)
Description
QUVID is a patient-reported outcomes questionnaire that collects responses about visual disturbance. Subjects were asked if they experienced any of the visual disturbances in the past 7 days from when the questionnaire was conducted and to answer about how severe their worst experience was on a scale from 0-4, where 0=none and 4=severe. The percentage of subjects responding "Severe" was calculated as (# of subjects responding "Severe") divided by (# of subjects with bilateral implantation and non-missing data in the specified category) times 100. Hypothesis testing was not planned for this outcome measure.
Time Frame
Month 6 (Day 120-180), post second eye implantation
Title
Rate of Most Bothersome Visual Disturbances as Reported by the Subject Using the QUVID
Description
Subjects were asked if they experienced any of the visual disturbances in the past 7 days from when the questionnaire was conducted and to answer how much the disturbance bothered them on a scale from 0-4, where 0=not bothered at all and 4=bothered very much. The percentage of subjects with most bothersome visual disturbances was calculated as (# of subjects responding "Bothered very much") divided by (# of subjects with bilateral implantation and non-missing data in the specified category) times 100. Hypothesis testing was not planned for this outcome measure.
Time Frame
Month 6 (Day 120-180), post second eye implantation
10. Eligibility
Sex
All
Minimum Age & Unit of Time
22 Years
Accepts Healthy Volunteers
No
Eligibility Criteria
Inclusion Criteria:
Diagnosed with bilateral cataracts with planned cataract removal by phacoemulsification with a clear cornea incision
Able to comprehend and willing to sign informed consent and complete all required postoperative follow-up procedures
Clear intraocular media other than cataract in both eyes.
Preoperative keratometric astigmatism of less than 1.0 diopter (D) in both operative eyes.
Exclusion Criteria:
Clinically significant corneal abnormalities including corneal dystrophy, irregularity, inflammation or edema
Previous refractive surgery or refractive surgery procedures (including, but not limited to LASIK, astigmatic keratotomy, and limbal relaxing incisions)
Glaucoma (uncontrolled or controlled with medication)
Degenerative eye disorders (e.g. macular degeneration or other retinal disorders)
Pregnant or lactating
Expected to require a second surgical intervention or retinal laser treatment.
Overall Study Officials:
First Name & Middle Initial & Last Name & Degree
Alcon Research
Organizational Affiliation
Alcon Research
Official's Role
Study Director
Facility Information:
Facility Name
Alcon Investigative Site
City
Fresno
State/Province
California
ZIP/Postal Code
93720
Country
United States
Facility Name
Alcon Investigative Site
City
Mount Dora
State/Province
Florida
ZIP/Postal Code
32757
Country
United States
Facility Name
Alcon Investigative Site
City
Panama City
State/Province
Florida
ZIP/Postal Code
32405
Country
United States
Facility Name
Alcon Investigative Site
City
Poughkeepsie
State/Province
New York
ZIP/Postal Code
12603
Country
United States
Facility Name
Alcon Investigative Site
City
Mount Pleasant
State/Province
South Carolina
ZIP/Postal Code
29464
Country
United States
Facility Name
Alcon Investigative Site
City
Sioux Falls
State/Province
South Dakota
ZIP/Postal Code
57108
Country
United States
Facility Name
Alcon Investigative Site
City
Nashville
State/Province
Tennessee
ZIP/Postal Code
37205
Country
United States
Facility Name
Alcon Investigative Site
City
Houston
State/Province
Texas
ZIP/Postal Code
77027
Country
United States
Facility Name
Alcon Investigative Site
City
Hurst
State/Province
Texas
ZIP/Postal Code
76054
Country
United States
Facility Name
Alcon Investigative Site
City
Nacogdoches
State/Province
Texas
ZIP/Postal Code
75965
Country
United States
Facility Name
Alcon Investigative Site
City
Salt Lake City
State/Province
Utah
ZIP/Postal Code
84107
Country
United States
Facility Name
Alcon Investigative Site
City
Norfolk
State/Province
Virginia
ZIP/Postal Code
23502
Country
United States
12. IPD Sharing Statement
Plan to Share IPD
No
Learn more about this trial
Clinical Investigation of AcrySof® IQ PanOptix™ IOL Model TFNT00