search
Back to results

High Resolution MRI Study for Prostate Cancer

Primary Purpose

Prostate Cancer

Status
Completed
Phase
Not Applicable
Locations
United States
Study Type
Interventional
Intervention
high resolution MRI (hrMRI)
Sponsored by
Cedars-Sinai Medical Center
About
Eligibility
Locations
Arms
Outcomes
Full info

About this trial

This is an interventional diagnostic trial for Prostate Cancer focused on measuring prostate cancer, MRI

Eligibility Criteria

19 Years - undefined (Adult, Older Adult)MaleDoes not accept healthy volunteers

Inclusion Criteria:

  • Age over 18 years
  • Patients diagnosed with clinically localized prostate cancer
  • Low or Low-intermediate Risk Prostate cancer1 defined as:
  • Pre-operative prostate specific antigen (PSA) ≤ 20.0 ng/ml
  • Clinical stage cT1 or cT2
  • Gleason score 3+3 or 3+4
  • Patients choosing AS or already on AS as primary management strategy
  • No previous treatment for prostate cancer with radiotherapy, chemotherapy, or hormonal therapy
  • No contraindications for gadolinium enhanced MRI

Exclusion Criteria:

  • No exclusion criteria

Sites / Locations

  • Cedars Sinai Medical Center

Arms of the Study

Arm 1

Arm Type

Other

Arm Label

Paired imaging

Arm Description

Single arm, paired imaging of high resolution MRI (hrMRI) and stand MRI (sMRI)

Outcomes

Primary Outcome Measures

Evidence of prostate cancer disease progression
evidence of disease progression as defined by any of the following: Increase in Gleason score from 3 + 3 to Gleason sum 7 on biopsy Gleason score 4+3 on biopsy Gleason sum 8-10 on biopsy > 3 Increase in number of positive cores Progression to nodal or bone involvement

Secondary Outcome Measures

Full Information

First Posted
September 21, 2017
Last Updated
December 14, 2022
Sponsor
Cedars-Sinai Medical Center
search

1. Study Identification

Unique Protocol Identification Number
NCT03292874
Brief Title
High Resolution MRI Study for Prostate Cancer
Official Title
Evaluation of a Novel High-Resolution Diffusion-Weighted MRI Sequence
Study Type
Interventional

2. Study Status

Record Verification Date
December 2022
Overall Recruitment Status
Completed
Study Start Date
September 13, 2017 (Actual)
Primary Completion Date
December 14, 2022 (Actual)
Study Completion Date
December 14, 2022 (Actual)

3. Sponsor/Collaborators

Responsible Party, by Official Title
Principal Investigator
Name of the Sponsor
Cedars-Sinai Medical Center

4. Oversight

Studies a U.S. FDA-regulated Drug Product
No
Studies a U.S. FDA-regulated Device Product
Yes
Product Manufactured in and Exported from the U.S.
Yes
Data Monitoring Committee
No

5. Study Description

Brief Summary
This high resolution MRI (hrMRI), along with stand MRI (sMRI) will be obtained at baseline and again in approximately 1 year in patients on prostate cancer active surveillance. Changes in lesion size and ADC values will be assessed on the serial studies. This study evaluates the hypothesis that hrMRI will detect changes that sMRI cannot detect and that these changes will correlate with prostate cancer progression as determined on prostate biopsy.
Detailed Description
2.0 BACKGROUND AND RATIONALE Multiparametric MRI Multiparametric MRI combining T2-weighted, diffusion-weighted, and dynamic contrast enhanced (DCE) images is commonly employed for detection and localization of prostate lesions. Diffusion-weighted imaging (DWI) is sensitive to the diffusion of water molecules interacting with surrounding macromolecules. DWI, which provides a quantitative biological parameter called apparent diffusion coefficient (ADC) value, is a robust MRI parameter for differentiating benign and malignant prostate tissue. In fact, the latest version of the Prostate Imaging-Reporting and Data System (PI-RADS) scoring system relies almost exclusively on DWI to identify tumors in the peripheral zone, which is where the vast majority of prostate cancers form. Findings on T2 images are not used to identify cancer, and DCE images are only used to differentiate between some PI-RADS 3 and 4 lesions. In a pilot study of prostate cancer AS, DW-MRI was useful for detecting progression of Gleason score based on changes in ADC value. Tumor size is another important clinical criterion for defining low risk prostate cancer, and tumor size based on DWI has been shown to crudely predict low risk prostate cancer. However, conventional DWI using single-shot echo-planar imaging is unable to detect small tumors, low grade tumors, or small changes in tumor size on serial imaging. Approximately 20% of small, low grade tumors found in men on AS are detected on modern prostate MRI. High Resolution MRI Investigators introduce a new three-dimensional (3D) high-resolution diffusion-weighted imaging sequence (HR-DWI), which improves image quality while conferring at least a 5-fold improvement in resolution when compared to standard two-dimensional (2D) DWI (S-DWI). This novel 3D DWI technique has been developed by our team and can be applied on existing 1.5T or 3T MRI systems. S-DWI suffers from two important limitations. a) It uses single-shot echo-planar imaging (EPI) for data acquisition, which produces magnetic susceptibility induced streaking artifacts and geometric distortions so that round objects may appear oval. b) The relatively low signal-to-noise ratio and 2D image acquisition with S-DWI limit spatial resolution, which is defined by the minimum distance between two objects required to resolve them uniquely. Our HR-DWI overcomes these limitations by using magnetization prepared, multi-shot, turbo-spin-echo acquisition, which improves signal-to-noise ratio (SNR), spatial resolution, and image quality, and eliminates geometric distortions and streaking artifacts associated with EPI. Preliminary studies In preliminary studies assessing the performance of our HR-DWI in a prospective pilot trial of prostate cancer AS patients, the technique could detect tumors not seen on S-DWI and measure ADC, which correlates with grade. This is important because the long-term natural history of small prostate cancers invisible to S-DWI has never been prospectively defined, in part due to lack of adequate imaging technology. In the era of molecular diagnostics and next-generation sequencing, an important step in understanding the biology of these lesions is to develop technologies to image and characterize these lesions. Importance of HR-DWI includes: Better imaging will allow these lesions to be monitored serially and targeted for biopsy, providing tissue for both histologic and molecular characterization. Higher resolution imaging will better delineate tumor boundaries, which can improve tumor staging and identify margins during partial-gland ablation by cryotherapy or high intensity focused ultrasound (HIFU), which was approved in 2015 by the U.S. FDA. Improved imaging resolution will allow for more accurate measurement of tumor size and ADC, and detection of small changes in size or grade over time. Standard prostate DWI has poor resolution; therefore, tumor growth kinetics have never been accepted as clinical criteria for cancer progression while on AS. If tumor growth kinetics or changes in grade determined by ADC prove prognostic, AS can rely less on serial transrectal biopsies, which can lead to serious complications.

6. Conditions and Keywords

Primary Disease or Condition Being Studied in the Trial, or the Focus of the Study
Prostate Cancer
Keywords
prostate cancer, MRI

7. Study Design

Primary Purpose
Diagnostic
Study Phase
Not Applicable
Interventional Study Model
Single Group Assignment
Model Description
Single arm, paired imaging
Masking
None (Open Label)
Allocation
N/A
Enrollment
56 (Actual)

8. Arms, Groups, and Interventions

Arm Title
Paired imaging
Arm Type
Other
Arm Description
Single arm, paired imaging of high resolution MRI (hrMRI) and stand MRI (sMRI)
Intervention Type
Diagnostic Test
Intervention Name(s)
high resolution MRI (hrMRI)
Intervention Description
high resolution MRI (hrMRI) and standard MRI (sMRI) will be obtained at baseline and again in approximately 1 year in patients on prostate cancer active surveillance.
Primary Outcome Measure Information:
Title
Evidence of prostate cancer disease progression
Description
evidence of disease progression as defined by any of the following: Increase in Gleason score from 3 + 3 to Gleason sum 7 on biopsy Gleason score 4+3 on biopsy Gleason sum 8-10 on biopsy > 3 Increase in number of positive cores Progression to nodal or bone involvement
Time Frame
3 years from baseline imaging

10. Eligibility

Sex
Male
Minimum Age & Unit of Time
19 Years
Accepts Healthy Volunteers
No
Eligibility Criteria
Inclusion Criteria: Age over 18 years Patients diagnosed with clinically localized prostate cancer Low or Low-intermediate Risk Prostate cancer1 defined as: Pre-operative prostate specific antigen (PSA) ≤ 20.0 ng/ml Clinical stage cT1 or cT2 Gleason score 3+3 or 3+4 Patients choosing AS or already on AS as primary management strategy No previous treatment for prostate cancer with radiotherapy, chemotherapy, or hormonal therapy No contraindications for gadolinium enhanced MRI Exclusion Criteria: No exclusion criteria
Overall Study Officials:
First Name & Middle Initial & Last Name & Degree
Hyung L Kim, MD
Organizational Affiliation
Cedars-Sinai Medical Center
Official's Role
Principal Investigator
Facility Information:
Facility Name
Cedars Sinai Medical Center
City
Los Angeles
State/Province
California
ZIP/Postal Code
90048
Country
United States

12. IPD Sharing Statement

Learn more about this trial

High Resolution MRI Study for Prostate Cancer

We'll reach out to this number within 24 hrs