Transcranial Magnetic Stimulation for Cocaine Addiction (BRAINSWITCH)
Cocaine Dependence, Substance Use Disorders, Chemical Addiction
About this trial
This is an interventional treatment trial for Cocaine Dependence focused on measuring cocaine, addiction, transcranial magnetic stimulation, neuromodulation, neuroimaging, brain stimulation
Eligibility Criteria
Inclusion Criteria:
- Current diagnosis of cocaine use disorder (from moderate to severe), based on the Diagnostic and Statistical Manual of Mental Disorder - Fifth Edition (DSM-5);
- Abstinence from cocaine for at least 48 hrs.
Exclusion Criteria:
- Current DSM-5 diagnosis of substance and/or alcohol use disorders other than nicotine;
- Current DSM-5 diagnosis of schizophrenia, bipolar disorder, or other psychotic disorder;
- Use in the past 4 weeks of any medication with known pro-convulsant action; or current regular use of any psychotropic medications (benzodiazepines, antipsychotic medications, tricyclic antidepressants, anti-epileptics, mood stabilizers);
- Any history of any clinically significant neurological disorder, including organic brain disease, epilepsy, stroke, brain lesions, multiple sclerosis, previous neurosurgery, or personal history of head trauma that resulted in loss of consciousness for > 5 minutes and retrograde amnesia for > 30 minutes;
- Any personal or family history (1st degree relatives) of seizures other than febrile childhood seizures;
- Any psychiatric, medical or social condition whether or not listed above, due to which, in the judgment of the PI and after any consults if indicated, participation in the study is not in the best interest of the patient;
- For female patients: Pregnancy/breastfeeding.
Subjects who have contraindications to MRI. Some of the exclusions are:
- Have non-MRI compatible metal in the body, such as a cardiac pacemaker, brain stimulator, shrapnel, surgical metal, clips in the brain or on blood vessels, cochlear implants, artificial heart valves or ferromagnetic fragments in the eye or oral cavity as these make having an MRI unsafe.
- Unable to lie flat on the back for the expected length of the experiment (50 minutes).
- Have an abnormality on the brain imaging or neurologic examination not related to the diagnosis.
- Uncomfortable being in a small space for the expected length of the experiment (50 minutes).
- Non-removable body piercing or tattoo posing MRI risk
- Pregnancy
Sites / Locations
- Department of Neuroscience, Imaging and Clinical SciencesRecruiting
- La Promessa ONLUS
Arms of the Study
Arm 1
Arm 2
Experimental
Placebo Comparator
Active Comparator: Active rTMS (15 Hz)
Sham Comparator: Sham rTMS (15 Hz)
The intervention will be Repetitive Transcranial Magnetic Stimulation. Each patient will receive active stimulation targeting the left dorsolateral prefrontal cortex (lDLPFC) with a frequency of 15 Hz and 100% of the individual resting motor threshold, for a total of 40 trains (60 stimuli per train, inter-train interval of 15 second, total duration 13 minutes). Each session will be repeated twice/daily for 10 consecutive days for 2 weeks, during the continued treatment phase. Following this, the participants will receive the maintenance intervention of 2 sessions per week for 3 months (rTMS follow-up), at the same parameters described above. Device: MagPro R30 with the Cool-B80 figure-of-eight coil (MagVenture, Falun, Denmark).
The intervention will be Repetitive Transcranial Magnetic Stimulation (Sham). rTMS will be used with the software necessary for the operator to remain blind to the stimulation condition. Also, the software will be pre-programmed by a staff member that will not be involved in data collection and analysis. The sham condition will match the number of pulses delivered during the 15Hz session and will use the same coil placement but the intensity of stimulation will be set a 3% of the individual resting motor threshold so to ensure that the participant will feel similar scalp sensations experienced by participants receiving active rTMS, but brain tissue will not be stimulated. Device: MagPro R30 with the Cool-B80 figure-of-eight coil (MagVenture, Falun, Denmark).