search
Back to results

Hypoglossal Nerve Stimulation on Cardiovascular Outcomes (CARDIOSA-12)

Primary Purpose

Obstructive Sleep Apnea

Status
Completed
Phase
Not Applicable
Locations
United States
Study Type
Interventional
Intervention
Therapeutic HGNS
Subtherapeutic 'Sham' HGNS
Sponsored by
University of Pennsylvania
About
Eligibility
Locations
Arms
Outcomes
Full info

About this trial

This is an interventional treatment trial for Obstructive Sleep Apnea focused on measuring Sleep apnea, Tongue stimulation, Cardiovascular function

Eligibility Criteria

22 Years - undefined (Adult, Older Adult)All SexesDoes not accept healthy volunteers

Eligibility Criteria: All patients recruited into the study will have already been implanted with the Inspire® device. Additional inclusion criteria include:

  • As tolerating the therapeutic level during sleep can take time (weeks to months), all patients must be able to use the device at the therapeutic setting (> 20 hours/week for > 1 month) prior to enrollment, based on compliance data.
  • All patients will be English-speaking and able to give written informed consent.

Exclusion Criteria include:

  • Inspire® remote Model 2500 or later is required. Patients with older remotes are not candidates due to limited adherence monitoring capabilities.
  • Patients who have fallen asleep while driving resulting in accident or "near miss" accident within 1 year prior to HGNS implantation.
  • Pregnant women will be excluded.*
  • Actively using positive airway pressure (PAP) therapy for treatment of OSA.
  • Patients in whom the difference between sham and therapeutic voltages is less than 30% the therapeutic voltage.
  • * Women of child bearing potential must NOT be pregnant or plan on becoming pregnant. This study involves temporarily stopping treatment of obstructive sleep apnea, which may harm the fetus. If applicable, the patient will need to take a urine pregnancy test after enrollment (prior to washout #1), and again prior to washout #2.

Sites / Locations

  • Hospital of the University of Pennsylvania

Arms of the Study

Arm 1

Arm 2

Arm Type

Experimental

Sham Comparator

Arm Label

Therapeutic HGNS

Subtherapeutic 'Sham' HGNS

Arm Description

Therapeutic Hypoglossal Nerve Stimulation (HGNS). Prior to enrollment in this study, the HGNS will have been implanted as part of clinical care, and a therapeutic voltage setting will have been determined via overnight sleep study.

Sham threshold determination will be performed as follows. The patient will be in a reclined position with the mouth open while nasal breathing. Stimulation will be increased from 0.1V up by 0.1V until bulk tongue motion is detected without obvious protrusion. This process is repeated twice and the average value is used to determine "sham-HGNS". The electrode configuration will remain consistent between the patient's therapeutic and sham thresholds.

Outcomes

Primary Outcome Measures

Mean 24-Hour Systolic Ambulatory Blood Pressure Values
Patients will undergo 24-hour ambulatory blood pressure testing (ABP) using a noninvasive, portable device. The monitor is programmed to record blood pressure every 30 minutes. The patient will be asked to record bedtime and wake time to corroborate the sleep and wake time from the recorder. Mean 24-hour systolic ambulatory blood pressure values will be calculated.

Secondary Outcome Measures

Mean 24-Hour Diastolic Ambulatory Blood Pressure Values
Patients will undergo 24-hour ambulatory blood pressure testing (ABP) using a noninvasive, portable device. The monitor is programmed to record blood pressure every 30 minutes. The patient will be asked to record bedtime and wake time to corroborate the sleep and wake time from the recorder. Mean 24-hour diastolic ambulatory blood pressure values will be calculated.
Mean Nocturnal Systolic and Diastolic Ambulatory Blood Pressure Values
Patients will undergo ambulatory blood pressure testing (ABP) using a noninvasive, portable device. The patient will be asked to record bedtime and wake time to corroborate the sleep and wake time from the recorder. Mean sleep systolic and diastolic ambulatory blood pressure values will be calculated.
Mean Muscle Sympathetic Nerve Activity (MSNA) Frequency (Bursts/Minute)
The peroneal nerve will be located with transcutaneous stimulation and a tungsten microelectrode will be inserted into the nerve, and a reference electrode will be inserted 1-2 cm from the recording electrode. Nerve signals will be preamplified, amplified, filtered, rectified, and integrated to obtain a mean voltage display of sympathetic nerve activity that is recorded. Muscle sympathetic bursts will be identified by visual inspection and expressed as burst frequency (bursts per minute). MSNA was only performed on 7 patients at Emory University, prior to the trial being transferred to the University of Pennsylvania. This is due to there being no research collaborators available at the University of Pennsylvania to capture MSNA as part of this trial. There is insufficient data gathered to make meaningful claims regarding this outcome measure.
Mean Muscle Sympathetic Nerve Activity (MSNA) Tonal Activity (Units/Minute)
The peroneal nerve will be located with transcutaneous stimulation and a tungsten microelectrode will be inserted into the nerve, and a reference electrode will be inserted 1-2 cm from the recording electrode. Nerve signals will be preamplified, amplified, filtered, rectified, and integrated to obtain tonal activity (units/minute). MSNA was only performed on 7 patients at Emory University, prior to the trial being transferred to the University of Pennsylvania. This is due to there being no research collaborators available at the University of Pennsylvania to capture MSNA as part of this trial. There is insufficient data gathered to make meaningful claims regarding this outcome measure.
Mean Pre-Ejection Period (PEP)
A patient will be fitted with Impedance Cardiography (ICG) Noninvasive Cardiac Output Module that will record the ECG (Electrocardiogram) and the ICG (Impedance cardiography) continuously during a 10-minute period. PEP will be calculated as the average interval (milliseconds) from the onset of left ventricular depolarization, reflected by the Q-wave onset in the ECG to the opening of the aortic valve, reflected by the B-point in the ICG signal. A significant difference in PEP to be a 10 millisecond increase from baseline.
Mean Flow-mediated Dilation (FMD)
The brachial artery of the nondominant arm will be imaged using a high-resolution ultrasound transducer. A blood pressure cuff on the forearm will be inflated to suprasystolic pressures to produce 5 min of ischemia. On cuff deflation, imaging will be performed to measure FMD. Brachial artery FMD will be calculated as (post-ischemia diameter - baseline diameter) / (baseline diameter) x 100.
Mean Peripheral Arterial Stiffness (PAS)
Following a rest period of 10 minutes with subjects in a supine position in a quiet, temperature-controlled room, blood pressure will be measured 3 times at 5-minute intervals by an automatic device. The standard metric of peripheral arterial stiffness (PAS) is carotid-femoral pulse wave velocity (PWV), which will be estimated using the Sphygmocor device® (Atcor Medical, Sydney, Australia). PAS was only captured on 21 patients at Emory University and the University of Pennsylvania. This is due to our cardiovascular research collaborators at the University of Pennsylvania indicating they would no longer be able to support our research study due to their own COVID-19 related resource constraints. There is insufficient data gathered to make meaningful claims regarding this outcome measure. PAS is reported as changes in pulse wave velocity, with a meters/second unit measure.
Mean Psychomotor Vigilance Test (PVT) Reciprocal Reaction Time
Patients will perform the neurobehavioral test on a specially calibrated (for timing precision) and designated laptop in a quiet room in the outpatient setting. Each patient will perform a unique version of the psychomotor vigilance test to assess psychomotor speed. The trial's protocol was amended to begin capturing neurobehavioral measures like the PVT at the University of Pennsylvania, as part of a new collaboration with research collaborators in the Department of Psychiatry. PVT is a validated instrument to capture attention, and response time on this cognitive test is reported as reciprocal milliseconds or 1/milliseconds.
Mean Digit Symbol Substitution Test (DSST) Reaction Time
Patients will perform the neurobehavioral test on a specially calibrated (for timing precision) and designated laptop in a quiet room in the outpatient setting. Each patient will perform a unique version of the digit symbol substitution test to assess processing speed. The trial's protocol was amended to begin capturing neurobehavioral measures like the DSST at the University of Pennsylvania, as part of a new collaboration with research collaborators in the Department of Psychiatry. DSST is a validated instrument to capture visual tracking and working memory, and response time on this cognitive test is reported in milliseconds.

Full Information

First Posted
November 27, 2017
Last Updated
March 29, 2023
Sponsor
University of Pennsylvania
Collaborators
American Heart Association, American Academy of Sleep Medicine
search

1. Study Identification

Unique Protocol Identification Number
NCT03359096
Brief Title
Hypoglossal Nerve Stimulation on Cardiovascular Outcomes
Acronym
CARDIOSA-12
Official Title
Cardiovascular Endpoints for Obstructive Sleep Apnea With Twelfth Nerve Stimulation (CARDIOSA-12): A Randomized, Sham-Controlled, Double-Blind, Crossover Trial
Study Type
Interventional

2. Study Status

Record Verification Date
March 2023
Overall Recruitment Status
Completed
Study Start Date
December 13, 2017 (Actual)
Primary Completion Date
January 21, 2022 (Actual)
Study Completion Date
January 21, 2022 (Actual)

3. Sponsor/Collaborators

Responsible Party, by Official Title
Principal Investigator
Name of the Sponsor
University of Pennsylvania
Collaborators
American Heart Association, American Academy of Sleep Medicine

4. Oversight

Studies a U.S. FDA-regulated Drug Product
No
Studies a U.S. FDA-regulated Device Product
Yes
Product Manufactured in and Exported from the U.S.
No
Data Monitoring Committee
Yes

5. Study Description

Brief Summary
A new, well-tolerated treatment for obstructive sleep apnea - tongue stimulation - is a device which opens the airway during sleep and can provide treatment for patients unable to use the mask and hose treatment. The study will evaluate the effect of this new treatment on blood pressure and heart-related measures to see if it lowers patients' risk of heart problems.
Detailed Description
Obstructive sleep apnea, repetitive airway blockage during sleep, affects 1 in 10 Americans. If left untreated, it results in decreased quality of life and increased risk of heart problems. Only half of these people are able to use the main treatment, continuous positive airway pressure (CPAP) therapy, which involves wearing a mask and hose at night. A new, well-tolerated treatment - tongue stimulation - is a device which opens the airway during sleep and can provide treatment for patients unable to use the mask and hose treatment. The study will evaluate the effect of this new treatment on blood pressure and heart-related measures to see if it lowers patients' risk of heart problems.

6. Conditions and Keywords

Primary Disease or Condition Being Studied in the Trial, or the Focus of the Study
Obstructive Sleep Apnea
Keywords
Sleep apnea, Tongue stimulation, Cardiovascular function

7. Study Design

Primary Purpose
Treatment
Study Phase
Not Applicable
Interventional Study Model
Crossover Assignment
Model Description
Washout Period 1 (Study Week 1): The patient will not use Hypoglossal Nerve Stimulation (HGNS) for 1 week. Randomization Visit (Study Week 2): The patient will be randomized to sub-therapeutic HGNS (sham) or therapeutic HGNS (treatment) for 28 days. Sympathetic and Vascular testing (Study Week 6). Washout Period 2 (Study Week 6-7): The patient will not use HGNS for 7 days. The patient will be switched to the other intervention arm (treatment to sham vs. sham to treatment) for 28 days. Sympathetic and Vascular testing (Study Week 11).
Masking
ParticipantInvestigatorOutcomes Assessor
Allocation
Randomized
Enrollment
63 (Actual)

8. Arms, Groups, and Interventions

Arm Title
Therapeutic HGNS
Arm Type
Experimental
Arm Description
Therapeutic Hypoglossal Nerve Stimulation (HGNS). Prior to enrollment in this study, the HGNS will have been implanted as part of clinical care, and a therapeutic voltage setting will have been determined via overnight sleep study.
Arm Title
Subtherapeutic 'Sham' HGNS
Arm Type
Sham Comparator
Arm Description
Sham threshold determination will be performed as follows. The patient will be in a reclined position with the mouth open while nasal breathing. Stimulation will be increased from 0.1V up by 0.1V until bulk tongue motion is detected without obvious protrusion. This process is repeated twice and the average value is used to determine "sham-HGNS". The electrode configuration will remain consistent between the patient's therapeutic and sham thresholds.
Intervention Type
Device
Intervention Name(s)
Therapeutic HGNS
Other Intervention Name(s)
Hypoglossal Nerve Stimulation
Intervention Description
Prior to enrollment in this study, the HGNS will have been implanted as part of clinical care, and a therapeutic voltage setting will have been determined via overnight sleep study The pulse generator, using technology from cardiac pacemakers, utilizes the signal from the pressure sensor for timing of stimulation to the tongue nerve. Patient will undergo activation of the implanted device one month post-operatively. A functional threshold (in volts) is obtained based on tongue motion during device stimulation. For the next month, the patient will have steadily increased stimulation strength by 0.1V every 2-3 nights within the preset range until the upper limit is reached.
Intervention Type
Device
Intervention Name(s)
Subtherapeutic 'Sham' HGNS
Other Intervention Name(s)
Sham Hypoglossal Nerve Stimulation
Intervention Description
Sham threshold determination will be performed as follows. The patient will be in a reclined position with the mouth open while nasal breathing. Stimulation will be increased from 0.1V up by 0.1V until bulk tongue motion is detected without obvious protrusion. This process is repeated twice and the average value is used to determine "sham-HGNS". The electrode configuration will remain consistent between the patient's therapeutic and sham thresholds
Primary Outcome Measure Information:
Title
Mean 24-Hour Systolic Ambulatory Blood Pressure Values
Description
Patients will undergo 24-hour ambulatory blood pressure testing (ABP) using a noninvasive, portable device. The monitor is programmed to record blood pressure every 30 minutes. The patient will be asked to record bedtime and wake time to corroborate the sleep and wake time from the recorder. Mean 24-hour systolic ambulatory blood pressure values will be calculated.
Time Frame
Study Week 6, Day 1; study Week 11, Day 1
Secondary Outcome Measure Information:
Title
Mean 24-Hour Diastolic Ambulatory Blood Pressure Values
Description
Patients will undergo 24-hour ambulatory blood pressure testing (ABP) using a noninvasive, portable device. The monitor is programmed to record blood pressure every 30 minutes. The patient will be asked to record bedtime and wake time to corroborate the sleep and wake time from the recorder. Mean 24-hour diastolic ambulatory blood pressure values will be calculated.
Time Frame
Study Week 6, Day 1; study Week 11, Day 1
Title
Mean Nocturnal Systolic and Diastolic Ambulatory Blood Pressure Values
Description
Patients will undergo ambulatory blood pressure testing (ABP) using a noninvasive, portable device. The patient will be asked to record bedtime and wake time to corroborate the sleep and wake time from the recorder. Mean sleep systolic and diastolic ambulatory blood pressure values will be calculated.
Time Frame
Study Week 6, Day 1; study Week 11, Day 1
Title
Mean Muscle Sympathetic Nerve Activity (MSNA) Frequency (Bursts/Minute)
Description
The peroneal nerve will be located with transcutaneous stimulation and a tungsten microelectrode will be inserted into the nerve, and a reference electrode will be inserted 1-2 cm from the recording electrode. Nerve signals will be preamplified, amplified, filtered, rectified, and integrated to obtain a mean voltage display of sympathetic nerve activity that is recorded. Muscle sympathetic bursts will be identified by visual inspection and expressed as burst frequency (bursts per minute). MSNA was only performed on 7 patients at Emory University, prior to the trial being transferred to the University of Pennsylvania. This is due to there being no research collaborators available at the University of Pennsylvania to capture MSNA as part of this trial. There is insufficient data gathered to make meaningful claims regarding this outcome measure.
Time Frame
Study Week 6, Day 2; Study Week 11, Day 2
Title
Mean Muscle Sympathetic Nerve Activity (MSNA) Tonal Activity (Units/Minute)
Description
The peroneal nerve will be located with transcutaneous stimulation and a tungsten microelectrode will be inserted into the nerve, and a reference electrode will be inserted 1-2 cm from the recording electrode. Nerve signals will be preamplified, amplified, filtered, rectified, and integrated to obtain tonal activity (units/minute). MSNA was only performed on 7 patients at Emory University, prior to the trial being transferred to the University of Pennsylvania. This is due to there being no research collaborators available at the University of Pennsylvania to capture MSNA as part of this trial. There is insufficient data gathered to make meaningful claims regarding this outcome measure.
Time Frame
Study Week 6, Day 2; Study Week 11, Day 2
Title
Mean Pre-Ejection Period (PEP)
Description
A patient will be fitted with Impedance Cardiography (ICG) Noninvasive Cardiac Output Module that will record the ECG (Electrocardiogram) and the ICG (Impedance cardiography) continuously during a 10-minute period. PEP will be calculated as the average interval (milliseconds) from the onset of left ventricular depolarization, reflected by the Q-wave onset in the ECG to the opening of the aortic valve, reflected by the B-point in the ICG signal. A significant difference in PEP to be a 10 millisecond increase from baseline.
Time Frame
Study Week 6, Day 2; Study Week 11, Day 2
Title
Mean Flow-mediated Dilation (FMD)
Description
The brachial artery of the nondominant arm will be imaged using a high-resolution ultrasound transducer. A blood pressure cuff on the forearm will be inflated to suprasystolic pressures to produce 5 min of ischemia. On cuff deflation, imaging will be performed to measure FMD. Brachial artery FMD will be calculated as (post-ischemia diameter - baseline diameter) / (baseline diameter) x 100.
Time Frame
Study Week 6, Day 2; Study Week 11, Day 2
Title
Mean Peripheral Arterial Stiffness (PAS)
Description
Following a rest period of 10 minutes with subjects in a supine position in a quiet, temperature-controlled room, blood pressure will be measured 3 times at 5-minute intervals by an automatic device. The standard metric of peripheral arterial stiffness (PAS) is carotid-femoral pulse wave velocity (PWV), which will be estimated using the Sphygmocor device® (Atcor Medical, Sydney, Australia). PAS was only captured on 21 patients at Emory University and the University of Pennsylvania. This is due to our cardiovascular research collaborators at the University of Pennsylvania indicating they would no longer be able to support our research study due to their own COVID-19 related resource constraints. There is insufficient data gathered to make meaningful claims regarding this outcome measure. PAS is reported as changes in pulse wave velocity, with a meters/second unit measure.
Time Frame
Study Week 6, Day 2; Study Week 11, Day 2
Title
Mean Psychomotor Vigilance Test (PVT) Reciprocal Reaction Time
Description
Patients will perform the neurobehavioral test on a specially calibrated (for timing precision) and designated laptop in a quiet room in the outpatient setting. Each patient will perform a unique version of the psychomotor vigilance test to assess psychomotor speed. The trial's protocol was amended to begin capturing neurobehavioral measures like the PVT at the University of Pennsylvania, as part of a new collaboration with research collaborators in the Department of Psychiatry. PVT is a validated instrument to capture attention, and response time on this cognitive test is reported as reciprocal milliseconds or 1/milliseconds.
Time Frame
Study Week 6, Day 2; Study Week 11, Day 2
Title
Mean Digit Symbol Substitution Test (DSST) Reaction Time
Description
Patients will perform the neurobehavioral test on a specially calibrated (for timing precision) and designated laptop in a quiet room in the outpatient setting. Each patient will perform a unique version of the digit symbol substitution test to assess processing speed. The trial's protocol was amended to begin capturing neurobehavioral measures like the DSST at the University of Pennsylvania, as part of a new collaboration with research collaborators in the Department of Psychiatry. DSST is a validated instrument to capture visual tracking and working memory, and response time on this cognitive test is reported in milliseconds.
Time Frame
Study Week 6, Day 2; Study Week 11, Day 2

10. Eligibility

Sex
All
Minimum Age & Unit of Time
22 Years
Accepts Healthy Volunteers
No
Eligibility Criteria
All patients recruited into the study will have already been implanted with the Inspire® HGNS device. Additional Inclusion Criteria include: As tolerating the therapeutic level during sleep can take time (weeks to months), all patients must be able to use the device at the therapeutic setting (> 20 hours/week for > 1 month) prior to enrollment, based on compliance data. All patients will be English-speaking and able to give written informed consent. Exclusion Criteria include: Inspire® remote Model 2500 or later is required. Patients with older remotes are not candidates due to limited adherence monitoring capabilities. Patients who have fallen asleep while driving resulting in accident or "near miss" accident within 1 year prior to HGNS implantation. Actively using positive airway pressure (PAP) therapy for treatment of OSA. Patients in whom the difference between sham and therapeutic voltages is less than 30% the therapeutic voltage. Pregnant women will be excluded.* Women of childbearing potential must NOT be pregnant or plan on becoming pregnant. This study involves temporarily stopping treatment of obstructive sleep apnea, which may harm the fetus. If applicable, the patient will need to take a urine pregnancy test after enrollment (prior to washout #1), and again prior to washout #2.
Overall Study Officials:
First Name & Middle Initial & Last Name & Degree
Raj C Dedhia, MD, MSCR
Organizational Affiliation
University of Pennsylvania
Official's Role
Principal Investigator
Facility Information:
Facility Name
Hospital of the University of Pennsylvania
City
Philadelphia
State/Province
Pennsylvania
ZIP/Postal Code
19104
Country
United States

12. IPD Sharing Statement

Citations:
PubMed Identifier
30194765
Citation
Dedhia RC, Quyyumi AA, Park J, Shah AJ, Strollo PJ, Bliwise DL. Cardiovascular endpoints for obstructive sleep apnea with twelfth cranial nerve stimulation (CARDIOSA-12): Rationale and methods. Laryngoscope. 2018 Nov;128(11):2635-2643. doi: 10.1002/lary.27284. Epub 2018 Sep 8.
Results Reference
background

Learn more about this trial

Hypoglossal Nerve Stimulation on Cardiovascular Outcomes

We'll reach out to this number within 24 hrs