search
Back to results

Measuring Oxygenation of Newborn Infants in Targeted Oxygen Ranges (MONITOR)

Primary Purpose

Premature Infant, Hypoxia, Hyperoxia

Status
Completed
Phase
Not Applicable
Locations
United Kingdom
Study Type
Interventional
Intervention
Higher target range
Sponsored by
University of Edinburgh
About
Eligibility
Locations
Arms
Outcomes
Full info

About this trial

This is an interventional treatment trial for Premature Infant focused on measuring Neonatology

Eligibility Criteria

48 Hours - 1 Month (Child)All SexesDoes not accept healthy volunteers

Inclusion Criteria:

  • Infants born at less than 29 weeks gestation
  • Infants greater than 48 hours of age
  • Infants who are receiving supplementary oxygen

Exclusion Criteria:

  • Congenital anomalies that would affect oxygenation (eg. cardiac defects, congenital diaphragmatic hernia)

Sites / Locations

  • Neonatal Unit - Royal Infirmary of Edinburgh

Arms of the Study

Arm 1

Arm 2

Arm Type

Experimental

No Intervention

Arm Label

Higher target range

Standard target range

Arm Description

Infants will be targeted to 92-97% oxygen saturation

Infants will be targeted to 90-95% oxygen saturation, which is the range used as routine in the Neonatal Unit involved in the study

Outcomes

Primary Outcome Measures

Incidence of hyperoxia and hypoxia on saturations
Percentage time spent above an SpO2 of 97% and below an SpO2 of 90% when infants are targeted to an SpO2 range of 92-97% compared to 90-95%

Secondary Outcome Measures

Incidence of hyperoxia and hypoxia on Transcutaneous monitoring
To discover the percentage time spent above a TcPO2 of 80mmHg and below a TcPO2 of 50mmHg when infants are targeted to an SpO2 range of 92-97% compared to 90-95%
Saturation variability
To discover the variability in SpO2 (measured by standard deviation) when infants are targeted to an SpO2 range of 92-97% compared to 90-95%
Transcutaneous variability
To discover the variability in TcPO2 (measured by standard deviation) when infants are targeted to an SpO2 range of 92-97% compared to 90-95%
Characterise PaO2 values within the two oxygen saturation target ranges
In infants who are undergoing PaO2 measurement as part of their routine care describe the PO2 values observed in the two target ranges
Pooled frequency histogram of SpO2
To generate a pooled frequency histogram of percentage time at each SpO2 point between 80 and 100% for infants targeted to an SpO2 range of 92-97% compared to 90-95%
Pooled frequency histogram of TcPO2
To generate a pooled frequency histogram of percentage time at a TcPO2 of below 30mmHg, 30-39.9mmHg, 40-49.9mmHg, 50-59.9mmHg, 60-69.9mmHg, 70-79.9mmHg, and 80mmHg and above for infants targeted to an SpO2 range of 92-97% compared to 90-95%

Full Information

First Posted
November 27, 2017
Last Updated
March 10, 2022
Sponsor
University of Edinburgh
Collaborators
NHS Lothian
search

1. Study Identification

Unique Protocol Identification Number
NCT03360292
Brief Title
Measuring Oxygenation of Newborn Infants in Targeted Oxygen Ranges
Acronym
MONITOR
Official Title
Describing the Differences in Oxygen Profiles in Premature Infants of Less Than 29 Weeks Gestational Age When Targeted to an Oxygen Saturation Range 92 to 97%, Compared to 90 to 95%
Study Type
Interventional

2. Study Status

Record Verification Date
September 2019
Overall Recruitment Status
Completed
Study Start Date
January 18, 2020 (Actual)
Primary Completion Date
May 18, 2021 (Actual)
Study Completion Date
February 17, 2022 (Actual)

3. Sponsor/Collaborators

Responsible Party, by Official Title
Sponsor
Name of the Sponsor
University of Edinburgh
Collaborators
NHS Lothian

4. Oversight

Studies a U.S. FDA-regulated Drug Product
No
Studies a U.S. FDA-regulated Device Product
No
Data Monitoring Committee
No

5. Study Description

Brief Summary
The investigators aim to measure the effect of targeting premature babies to a slightly higher oxygen saturation target range (92-97%) than routinely used, for a brief period, to plan a future larger study of the effect of this on clinical outcomes. It is still unclear exactly what levels of oxygen premature babies need - both too little or too much oxygen in the first weeks after birth may be harmful. Previous studies used saturation monitoring (SpO2), where a small probe shines light through the skin and calculates how much oxygen is carried in the blood. These studies demonstrated using an SpO2 range of 91-95% rather than 85-89% was associated with more babies surviving and fewer babies suffering from a bowel condition called necrotising enterocolitis (NEC). However, targeting oxygen higher increased the number of infants who needed treatment for an eye condition called retinopathy of prematurity (ROP). It is possible an SpO2 range higher than 91-95% would be associated with even better survival. It is also possible that a higher range might not improve survival but could increase the need for ROP treatment. Infants born at less than 29 weeks gestation, greater than 48 hours of age and receiving supplementary oxygen would be eligible for inclusion. The study is at the Royal Infirmary of Edinburgh. Total study time is 12 hours for each infant (6 hours at the standard 90-95% range used in our unit, and 6 hours at 92-97%). It is a crossover study with infants acting as their own controls. Based on previous research the investigators are confident these oxygen levels will not be dangerously high. To provide an additional measure of oxygen the investigators will also use a transcutaneous monitor for the 12 hour study period, which fastens gently to the skin and measures oxygen and carbon dioxide levels on the skin surface.
Detailed Description
This study is a single centre randomised crossover study. Infants born at less than 29 weeks gestation, greater than 48 hours of age and receiving supplementary oxygen would be eligible for inclusion. The study is at the Royal Infirmary of Edinburgh. Total study time is 12 hours for each infant (6 hours at the standard 90-95% range used in our unit, and 6 hours at 92-97%). It is a crossover study with infants acting as their own controls. A complete list of all monitoring that will be carried out is shown below: SpO2 monitoring TcPO2 monitoring Heart rate monitoring (used to validate SpO2 readings as described below) Arterial gas sampling (only if conducted by the direct care team as part of the routine care of the infant will these be recorded. No extra blood samples will be taken as part of the study) Each infant will be monitored simultaneously with an SpO2 monitor and TcPo2 monitor, with data recording starting from the time the transcutaneous monitor finishes calibrating. SpO2 readings will be downloaded directly from the multiparameter patient monitor. SpO2 will be measured using a Siemens Infinity SC7000 multiparameter monitor. This monitor uses Siemens' Oxisure pulse oximetry technology and Nellcor Oximax saturation probes and incorporates ECG to reduce motion artefact. To reduce the influence of artefact further, data from an infants chest leads (recording heart rate) will also be downloaded. If there is a greater than 10 beats per minute difference between heart rate measured from the pulse oximeter and heart rate measured from the chest leads, SpO2 for that time point will be disregarded. TcPO2 will be measured using a SenTec Digital Monitoring System with OxiVent sensor. TcPO2 is calculated by dynamic fluorescence quenching which measures oxygen molecules present in the vicinity of a fluorescent dye incorporated within the sensor surface. The sensor is operated at a constant temperature of 43 degrees Celsius. Control of sensor temperature and application duration are designed to meet all applicable standards and this monitoring device is used routinely in many neonatal units, with transcutaneous monitoring part of the monitoring equipment we use in selected infants in our unit and being transported by our local neonatal transport team. Temperature is supervised by two independent circuits, as well as by the monitor firmware. Transcutaneous data will be transferred contemporaneously to a bedside PC via the proprietary software V-STATS (with V-CareNeT) version 4.01. We will ensure the time on the monitor is synchronised with the time displayed on the electronic patient record system recording SpO2 and heart rate. V-STATS software can identify any spurious spikes in TcPO2 caused by air bubbles and these identified segments of data will be discarded. Artefact has not significantly affected readings during the routine use of this monitor previously on our neonatal unit and with our neonatal transport team. The site of the transcutaneous probe will be rotated on each infant every 2 hours. SpO2, TcPO2 and heart rate data will be recorded every second. The time of any arterial oxygen samples taken routinely during the study will be recorded from the unit Radiometer ABL800 FLEX blood gas analyser.

6. Conditions and Keywords

Primary Disease or Condition Being Studied in the Trial, or the Focus of the Study
Premature Infant, Hypoxia, Hyperoxia
Keywords
Neonatology

7. Study Design

Primary Purpose
Treatment
Study Phase
Not Applicable
Interventional Study Model
Crossover Assignment
Model Description
This is a randomised cross-over study of oxygen target ranges in premature infants, with infants acting as their own controls.
Masking
None (Open Label)
Masking Description
Infants will be randomised to either higher (92-97%) or lower (90-95%) oxygen saturation target range, and then cross-over to the alternative range after 6 hours of monitoring (with 12 hours in total study time). The study is randomised but not blinded.
Allocation
Randomized
Enrollment
20 (Actual)

8. Arms, Groups, and Interventions

Arm Title
Higher target range
Arm Type
Experimental
Arm Description
Infants will be targeted to 92-97% oxygen saturation
Arm Title
Standard target range
Arm Type
No Intervention
Arm Description
Infants will be targeted to 90-95% oxygen saturation, which is the range used as routine in the Neonatal Unit involved in the study
Intervention Type
Other
Intervention Name(s)
Higher target range
Other Intervention Name(s)
Using a higher oxygen saturation target range
Intervention Description
Intervention is using a higher oxygen saturation target range than in routine practice
Primary Outcome Measure Information:
Title
Incidence of hyperoxia and hypoxia on saturations
Description
Percentage time spent above an SpO2 of 97% and below an SpO2 of 90% when infants are targeted to an SpO2 range of 92-97% compared to 90-95%
Time Frame
12 hours
Secondary Outcome Measure Information:
Title
Incidence of hyperoxia and hypoxia on Transcutaneous monitoring
Description
To discover the percentage time spent above a TcPO2 of 80mmHg and below a TcPO2 of 50mmHg when infants are targeted to an SpO2 range of 92-97% compared to 90-95%
Time Frame
12 hours
Title
Saturation variability
Description
To discover the variability in SpO2 (measured by standard deviation) when infants are targeted to an SpO2 range of 92-97% compared to 90-95%
Time Frame
12 hours
Title
Transcutaneous variability
Description
To discover the variability in TcPO2 (measured by standard deviation) when infants are targeted to an SpO2 range of 92-97% compared to 90-95%
Time Frame
12 hours
Title
Characterise PaO2 values within the two oxygen saturation target ranges
Description
In infants who are undergoing PaO2 measurement as part of their routine care describe the PO2 values observed in the two target ranges
Time Frame
12 hours
Title
Pooled frequency histogram of SpO2
Description
To generate a pooled frequency histogram of percentage time at each SpO2 point between 80 and 100% for infants targeted to an SpO2 range of 92-97% compared to 90-95%
Time Frame
12 hours
Title
Pooled frequency histogram of TcPO2
Description
To generate a pooled frequency histogram of percentage time at a TcPO2 of below 30mmHg, 30-39.9mmHg, 40-49.9mmHg, 50-59.9mmHg, 60-69.9mmHg, 70-79.9mmHg, and 80mmHg and above for infants targeted to an SpO2 range of 92-97% compared to 90-95%
Time Frame
12 hours

10. Eligibility

Sex
All
Minimum Age & Unit of Time
48 Hours
Maximum Age & Unit of Time
1 Month
Accepts Healthy Volunteers
No
Eligibility Criteria
Inclusion Criteria: Infants born at less than 29 weeks gestation Infants greater than 48 hours of age Infants who are receiving supplementary oxygen Exclusion Criteria: Congenital anomalies that would affect oxygenation (eg. cardiac defects, congenital diaphragmatic hernia)
Facility Information:
Facility Name
Neonatal Unit - Royal Infirmary of Edinburgh
City
Edinburgh
State/Province
Lothian
ZIP/Postal Code
EH16 4SA
Country
United Kingdom

12. IPD Sharing Statement

Plan to Share IPD
No

Learn more about this trial

Measuring Oxygenation of Newborn Infants in Targeted Oxygen Ranges

We'll reach out to this number within 24 hrs