About this trial

This is an interventional diagnostic trial for Abdominal Injuries

Eligibility Criteria

0 Years - 7 Years (Child)All SexesAccepts Healthy Volunteers

Inclusion Criteria for study CEUS

  1. Males or females < 8 years of age at time of enrollment
  2. Clinically stable (defined as not undergoing an emergent surgical procedure in the next hour)
  3. Abdominal CT ordered or obtained
  4. IV in place

Exclusion Criteria for study CEUS

  1. Unable to obtain contrast-enhanced ultrasound within 72 hours after CT
  2. History of allergic reaction to Lumason, sulfa-hexafluoride lipid microsphere components, or other ingredients in Lumason (polyethylene glycol 4000, distearoylphosphatidylcholine (DSPC), dipalmitoylphosphatidylglycerol sodium (DPPG-Na) palmitic acid)
  3. Known congenital or acquired heart disease

Alternative Inclusion and Exclusion Criteria for children who have undergone or are undergoing CEUS as part of clinical care

Inclusion criteria:

  1. Males or females < 8 years of age at time of CEUS.
  2. Clinical Team plans to perform CT or has performed CT as part of clinical care for abdominal trauma
  3. Clinical Team plans to perform (or has performed) CEUS as part of clinical care
  4. Date of CEUS after January 1, 2015

Exclusion Criteria: None

Sites / Locations

  • Children's Hospital of Philadelphia

Arms of the Study

Arm 1

Arm 2

Arm 3

Arm Type

No Intervention

No Intervention

Other

Arm Label

Retrospective Review

Prospective Observation

Contrast-Enhanced Ultrasound using Lumason

Arm Description

Comparison of CT and CEUS results from retrospective chart review of children who have had a CEUS for trauma at the Children's Hospital of Philadelphia (CHOP).

Prospective observation of comparison of CT and CEUS results among children who are undergoing a CEUS and abdominal CT as part of clinical care.

Prospective intervention using contrast enhanced ultrasound with IV contrast Lumason.

Outcomes

Primary Outcome Measures

Sensitivity of Contrast-Enhanced Ultrasound in detection of abdominal solid organ injury in young children <8 years of age
To determine the sensitivity of contrast-enhanced ultrasound (CEUS) compared with standard, abdominal Computer Tomography (CT) in the detection of abdominal solid organ injury in young children < 8 years of age with concern for blunt abdominal trauma.
Specificity of Contrast-Enhanced Ultrasound in detection of abdominal solid organ injury in young children <8 years of age
To determine the specificity of contrast-enhanced ultrasound (CEUS) compared with standard, abdominal Computer Tomography (CT) in the detection of abdominal solid organ injury in young children < 8 years of age with concern for blunt abdominal trauma.

Secondary Outcome Measures

Full Information

First Posted
March 15, 2018
Last Updated
January 3, 2023
Sponsor
Children's Hospital of Philadelphia
Collaborators
The Ray E. Helfer Society
search

1. Study Identification

Unique Protocol Identification Number
NCT03473249
Brief Title
Effectiveness of Contrast-Enhanced Ultrasound
Official Title
Clinical Effectiveness of Contrast-Enhanced Ultrasound in the Evaluation of Blunt Abdominal Trauma in Young Children
Study Type
Interventional

2. Study Status

Record Verification Date
January 2023
Overall Recruitment Status
Active, not recruiting
Study Start Date
May 9, 2018 (Actual)
Primary Completion Date
December 2023 (Anticipated)
Study Completion Date
December 2023 (Anticipated)

3. Sponsor/Collaborators

Responsible Party, by Official Title
Sponsor
Name of the Sponsor
Children's Hospital of Philadelphia
Collaborators
The Ray E. Helfer Society

4. Oversight

Studies a U.S. FDA-regulated Drug Product
Yes
Studies a U.S. FDA-regulated Device Product
No
Product Manufactured in and Exported from the U.S.
No
Data Monitoring Committee
No

5. Study Description

Brief Summary
The purpose of the study is to generate pilot data describing test characteristics of contrast enhanced ultrasound in young children with concern for abdominal trauma. The primary objective in this study is to determine the sensitivity and specificity of contrast-enhanced ultrasound (CEUS) compared to abdominal Computed Tomography (CT) in the detection of abdominal solid organ injury in young children < 8 years of age with concern for blunt abdominal trauma.
Detailed Description
Abdominal trauma in children can be deadly, but intra-abdominal injuries can be difficult to detect and often lack external signs of injury on physical exam. The current gold standard imaging study is Computed Tomography (CT) with IV contrast, which is associated with radiation exposure. Contrast-enhanced ultrasound is a radiation-free alternative to detect abdominal injuries and has been studied primarily in adults and some older children, but evidence to support its use in young children is needed. This is a prospective study of children less than 8 years of age who are clinically stable and undergoing an abdominal CT with IV contrast as part of their clinical care due to concerns for abdominal trauma. Investigators will compare CEUS results with those obtained by CT. Investigators will additionally include retrospective data of children who underwent both abdominal CT and CEUS as part of clinical care.

6. Conditions and Keywords

Primary Disease or Condition Being Studied in the Trial, or the Focus of the Study
Abdominal Injuries, Physical Abuse, Accidental Fall, Motor Vehicle Injury

7. Study Design

Primary Purpose
Diagnostic
Study Phase
Phase 4
Interventional Study Model
Single Group Assignment
Masking
None (Open Label)
Allocation
Non-Randomized
Enrollment
120 (Anticipated)

8. Arms, Groups, and Interventions

Arm Title
Retrospective Review
Arm Type
No Intervention
Arm Description
Comparison of CT and CEUS results from retrospective chart review of children who have had a CEUS for trauma at the Children's Hospital of Philadelphia (CHOP).
Arm Title
Prospective Observation
Arm Type
No Intervention
Arm Description
Prospective observation of comparison of CT and CEUS results among children who are undergoing a CEUS and abdominal CT as part of clinical care.
Arm Title
Contrast-Enhanced Ultrasound using Lumason
Arm Type
Other
Arm Description
Prospective intervention using contrast enhanced ultrasound with IV contrast Lumason.
Intervention Type
Drug
Intervention Name(s)
Contrast-Enhanced Ultrasound using Lumason
Other Intervention Name(s)
SonoVue (25 mg under sulfur hexafluoride gas) / Lumason, Sulfur hexafluoride microbubbles for injection, US Patent No. 5,686,060
Intervention Description
Subjects will undergo a contrast enhanced ultrasound (CEUS) during which a standard greyscale abdominal ultrasound is performed first followed by injection of intravenous contrast with Lumason, and completion of contrast-enhanced ultrasound
Primary Outcome Measure Information:
Title
Sensitivity of Contrast-Enhanced Ultrasound in detection of abdominal solid organ injury in young children <8 years of age
Description
To determine the sensitivity of contrast-enhanced ultrasound (CEUS) compared with standard, abdominal Computer Tomography (CT) in the detection of abdominal solid organ injury in young children < 8 years of age with concern for blunt abdominal trauma.
Time Frame
2 years
Title
Specificity of Contrast-Enhanced Ultrasound in detection of abdominal solid organ injury in young children <8 years of age
Description
To determine the specificity of contrast-enhanced ultrasound (CEUS) compared with standard, abdominal Computer Tomography (CT) in the detection of abdominal solid organ injury in young children < 8 years of age with concern for blunt abdominal trauma.
Time Frame
2 years

10. Eligibility

Sex
All
Minimum Age & Unit of Time
0 Years
Maximum Age & Unit of Time
7 Years
Accepts Healthy Volunteers
Accepts Healthy Volunteers
Eligibility Criteria
Inclusion Criteria for study CEUS Males or females < 8 years of age at time of enrollment Clinically stable (defined as not undergoing an emergent surgical procedure in the next hour) Abdominal CT ordered or obtained IV in place Exclusion Criteria for study CEUS Unable to obtain contrast-enhanced ultrasound within 72 hours after CT History of allergic reaction to Lumason, sulfa-hexafluoride lipid microsphere components, or other ingredients in Lumason (polyethylene glycol 4000, distearoylphosphatidylcholine (DSPC), dipalmitoylphosphatidylglycerol sodium (DPPG-Na) palmitic acid) Known congenital or acquired heart disease Alternative Inclusion and Exclusion Criteria for children who have undergone or are undergoing CEUS as part of clinical care Inclusion criteria: Males or females < 8 years of age at time of CEUS. Clinical Team plans to perform CT or has performed CT as part of clinical care for abdominal trauma Clinical Team plans to perform (or has performed) CEUS as part of clinical care Date of CEUS after January 1, 2015 Exclusion Criteria: None
Facility Information:
Facility Name
Children's Hospital of Philadelphia
City
Philadelphia
State/Province
Pennsylvania
ZIP/Postal Code
19104
Country
United States

12. IPD Sharing Statement

Plan to Share IPD
Undecided
Citations:
PubMed Identifier
16385300
Citation
Wood J, Rubin DM, Nance ML, Christian CW. Distinguishing inflicted versus accidental abdominal injuries in young children. J Trauma. 2005 Nov;59(5):1203-8. doi: 10.1097/01.ta.0000196437.07011.b1.
Results Reference
background
PubMed Identifier
15185237
Citation
Lutz N, Nance ML, Kallan MJ, Arbogast KB, Durbin DR, Winston FK. Incidence and clinical significance of abdominal wall bruising in restrained children involved in motor vehicle crashes. J Pediatr Surg. 2004 Jun;39(6):972-5. doi: 10.1016/j.jpedsurg.2004.02.029.
Results Reference
background
PubMed Identifier
26850907
Citation
Carter KW, Moulton SL. Pediatric abdominal injury patterns caused by "falls": A comparison between nonaccidental and accidental trauma. J Pediatr Surg. 2016 Feb;51(2):326-8. doi: 10.1016/j.jpedsurg.2015.10.056. Epub 2015 Oct 31.
Results Reference
background
PubMed Identifier
3172310
Citation
Cooper A, Floyd T, Barlow B, Niemirska M, Ludwig S, Seidl T, O'Neill J, Templeton J, Ziegler M, Ross A, et al. Major blunt abdominal trauma due to child abuse. J Trauma. 1988 Oct;28(10):1483-7. doi: 10.1097/00005373-198810000-00015.
Results Reference
background
PubMed Identifier
19620197
Citation
Lindberg D, Makoroff K, Harper N, Laskey A, Bechtel K, Deye K, Shapiro R; ULTRA Investigators. Utility of hepatic transaminases to recognize abuse in children. Pediatrics. 2009 Aug;124(2):509-16. doi: 10.1542/peds.2008-2348. Epub 2009 Jul 20.
Results Reference
background
PubMed Identifier
23319537
Citation
Lindberg DM, Shapiro RA, Blood EA, Steiner RD, Berger RP; ExSTRA investigators. Utility of hepatic transaminases in children with concern for abuse. Pediatrics. 2013 Feb;131(2):268-75. doi: 10.1542/peds.2012-1952. Epub 2013 Jan 14.
Results Reference
background
PubMed Identifier
20936274
Citation
Trout AT, Strouse PJ, Mohr BA, Khalatbari S, Myles JD. Abdominal and pelvic CT in cases of suspected abuse: can clinical and laboratory findings guide its use? Pediatr Radiol. 2011 Jan;41(1):92-8. doi: 10.1007/s00247-010-1847-8. Epub 2010 Oct 9.
Results Reference
background
PubMed Identifier
2359686
Citation
Hennes HM, Smith DS, Schneider K, Hegenbarth MA, Duma MA, Jona JZ. Elevated liver transaminase levels in children with blunt abdominal trauma: a predictor of liver injury. Pediatrics. 1990 Jul;86(1):87-90.
Results Reference
background
PubMed Identifier
10784214
Citation
Rothrock SG, Green SM, Morgan R. Abdominal trauma in infants and children: prompt identification and early management of serious and life-threatening injuries. Part I: injury patterns and initial assessment. Pediatr Emerg Care. 2000 Apr;16(2):106-15. doi: 10.1097/00006565-200004000-00012.
Results Reference
background
PubMed Identifier
21847723
Citation
Goske MJ, Applegate KE, Bulas D, Butler PF, Callahan MJ, Coley BD, Don S, Frush DP, Hernanz-Schulman M, Kaste SC, Morrison G, Sidhu M, Strauss KJ, Treves ST; Alliance for Radiation Safety in Pediatric Imaging. Image Gently: progress and challenges in CT education and advocacy. Pediatr Radiol. 2011 Sep;41 Suppl 2:461-6. doi: 10.1007/s00247-011-2133-0. Epub 2011 Aug 17.
Results Reference
background
PubMed Identifier
28255580
Citation
Laugesen NG, Nolsoe CP, Rosenberg J. Clinical Applications of Contrast-Enhanced Ultrasound in the Pediatric Work-Up of Focal Liver Lesions and Blunt Abdominal Trauma: A Systematic Review. Ultrasound Int Open. 2017 Feb;3(1):E2-E7. doi: 10.1055/s-0042-124502.
Results Reference
background
PubMed Identifier
27075018
Citation
Miele V, Piccolo CL, Trinci M, Galluzzo M, Ianniello S, Brunese L. Diagnostic imaging of blunt abdominal trauma in pediatric patients. Radiol Med. 2016 May;121(5):409-30. doi: 10.1007/s11547-016-0637-2. Epub 2016 Apr 13.
Results Reference
background
PubMed Identifier
18682877
Citation
Catalano O, Aiani L, Barozzi L, Bokor D, De Marchi A, Faletti C, Maggioni F, Montanari N, Orlandi PE, Siani A, Sidhu PS, Thompson PK, Valentino M, Ziosi A, Martegani A. CEUS in abdominal trauma: multi-center study. Abdom Imaging. 2009 Mar-Apr;34(2):225-34. doi: 10.1007/s00261-008-9452-0.
Results Reference
background
PubMed Identifier
18503121
Citation
Clevert DA, Weckbach S, Minaifar N, Clevert DA, Stickel M, Reiser M. Contrast-enhanced ultrasound versus MS-CT in blunt abdominal trauma. Clin Hemorheol Microcirc. 2008;39(1-4):155-69.
Results Reference
background
PubMed Identifier
19484583
Citation
Manetta R, Pistoia ML, Bultrini C, Stavroulis E, Di Cesare E, Masciocchi C. Ultrasound enhanced with sulphur-hexafluoride-filled microbubbles agent (SonoVue) in the follow-up of mild liver and spleen trauma. Radiol Med. 2009 Aug;114(5):771-9. doi: 10.1007/s11547-009-0406-6. Epub 2009 May 30. English, Italian.
Results Reference
background
PubMed Identifier
18376464
Citation
Thorelius L. Emergency real-time contrast-enhanced ultrasonography for detection of solid organ injuries. Eur Radiol. 2007 Dec;17 Suppl 6:F107-11. doi: 10.1007/s10406-007-0235-4.
Results Reference
background
PubMed Identifier
16632732
Citation
Valentino M, Serra C, Zironi G, De Luca C, Pavlica P, Barozzi L. Blunt abdominal trauma: emergency contrast-enhanced sonography for detection of solid organ injuries. AJR Am J Roentgenol. 2006 May;186(5):1361-7. doi: 10.2214/AJR.05.0027.
Results Reference
background
PubMed Identifier
16965977
Citation
Piscaglia F, Bolondi L; Italian Society for Ultrasound in Medicine and Biology (SIUMB) Study Group on Ultrasound Contrast Agents. The safety of Sonovue in abdominal applications: retrospective analysis of 23188 investigations. Ultrasound Med Biol. 2006 Sep;32(9):1369-75. doi: 10.1016/j.ultrasmedbio.2006.05.031.
Results Reference
background
PubMed Identifier
14652701
Citation
Oldenburg A, Hohmann J, Skrok J, Albrecht T. Imaging of paediatric splenic injury with contrast-enhanced ultrasonography. Pediatr Radiol. 2004 Apr;34(4):351-4. doi: 10.1007/s00247-003-1092-5. Epub 2003 Dec 2.
Results Reference
background
PubMed Identifier
18195385
Citation
Valentino M, Serra C, Pavlica P, Labate AM, Lima M, Baroncini S, Barozzi L. Blunt abdominal trauma: diagnostic performance of contrast-enhanced US in children--initial experience. Radiology. 2008 Mar;246(3):903-9. doi: 10.1148/radiol.2463070652. Epub 2008 Jan 14.
Results Reference
background
PubMed Identifier
25822953
Citation
Menichini G, Sessa B, Trinci M, Galluzzo M, Miele V. Accuracy of contrast-enhanced ultrasound (CEUS) in the identification and characterization of traumatic solid organ lesions in children: a retrospective comparison with baseline US and CE-MDCT. Radiol Med. 2015 Nov;120(11):989-1001. doi: 10.1007/s11547-015-0535-z. Epub 2015 Mar 31.
Results Reference
background
PubMed Identifier
23052725
Citation
Riccabona M. Application of a second-generation US contrast agent in infants and children--a European questionnaire-based survey. Pediatr Radiol. 2012 Dec;42(12):1471-80. doi: 10.1007/s00247-012-2472-5. Epub 2012 Oct 3.
Results Reference
background
PubMed Identifier
25701526
Citation
Piskunowicz M, Kosiak W, Batko T, Piankowski A, Polczynska K, Adamkiewicz-Drozynska E. Safety of intravenous application of second-generation ultrasound contrast agent in children: prospective analysis. Ultrasound Med Biol. 2015 Apr;41(4):1095-9. doi: 10.1016/j.ultrasmedbio.2014.11.003. Epub 2015 Feb 18.
Results Reference
background
PubMed Identifier
27959665
Citation
Yusuf GT, Sellars ME, Deganello A, Cosgrove DO, Sidhu PS. Retrospective Analysis of the Safety and Cost Implications of Pediatric Contrast-Enhanced Ultrasound at a Single Center. AJR Am J Roentgenol. 2017 Feb;208(2):446-452. doi: 10.2214/AJR.16.16700. Epub 2016 Dec 13.
Results Reference
background
PubMed Identifier
24132647
Citation
Jacob J, Deganello A, Sellars ME, Hadzic N, Sidhu PS. Contrast enhanced ultrasound (CEUS) characterization of grey-scale sonographic indeterminate focal liver lesions in pediatric practice. Ultraschall Med. 2013 Dec;34(6):529-40. doi: 10.1055/s-0033-1355785. Epub 2013 Oct 16.
Results Reference
background
PubMed Identifier
23396596
Citation
Bonini G, Pezzotta G, Morzenti C, Agazzi R, Nani R. Contrast-enhanced ultrasound with SonoVue in the evaluation of postoperative complications in pediatric liver transplant recipients. J Ultrasound. 2007 Jun;10(2):99-106. doi: 10.1016/j.jus.2007.02.008. Epub 2007 Jun 13.
Results Reference
background
PubMed Identifier
27300274
Citation
Knieling F, Strobel D, Rompel O, Zapke M, Menendez-Castro C, Wolfel M, Schulz J, Rascher W, Jungert J. Spectrum, Applicability and Diagnostic Capacity of Contrast-Enhanced Ultrasound in Pediatric Patients and Young Adults after Intravenous Application - A Retrospective Trial. Ultraschall Med. 2016 Dec;37(6):619-626. doi: 10.1055/s-0042-108429. Epub 2016 Jun 14.
Results Reference
background
PubMed Identifier
26674117
Citation
Stenzel M. Intravenous contrast-enhanced sonography in children and adolescents - a single center experience. J Ultrason. 2013 Jun;13(53):133-44. doi: 10.15557/JoU.2013.0014. Epub 2013 Jun 30.
Results Reference
background
PubMed Identifier
27610750
Citation
Rafailidis V, Deganello A, Watson T, Sidhu PS, Sellars ME. Enhancing the role of paediatric ultrasound with microbubbles: a review of intravenous applications. Br J Radiol. 2017 Jan;90(1069):20160556. doi: 10.1259/bjr.20160556. Epub 2016 Sep 26.
Results Reference
background

Learn more about this trial

Effectiveness of Contrast-Enhanced Ultrasound

We'll reach out to this number within 24 hrs