Noninferiority Trial of MitraClip Implantation Strategies: 1 Clip vs. 2 Clips in Patients With Functional Mitral Regurgitation (One-Plus-One)

Primary Purpose

Mitral Regurgitation Functional

Status
Withdrawn
Phase
Not Applicable
Locations
Study Type
Interventional
Intervention
MitraClip implantation
Sponsored by
Asklepios proresearch
About
Eligibility
Locations
Arms
Outcomes
Full info

About this trial

This is an interventional treatment trial for Mitral Regurgitation Functional focused on measuring Mitral Regurgitation, transcatheter mitral valve repair, MitraClip

Eligibility Criteria

18 Years - undefined (Adult, Older Adult)All SexesDoes not accept healthy volunteers

Inclusion Criteria:

  • Absence of a structural abnormality of the mitral valve giving rise to MR.
  • MR severity of US grade 3+ or 4+ of central or noncentral origin
  • Patient must consent to randomization in the hybrid operating theater upon successful implantation of a single MitraClip. Written informed consent must be provided prior to the MitraClip procedure.

Exclusion Criteria:

  • patients with primary regurgitation

Sites / Locations

    Arms of the Study

    Arm 1

    Arm 2

    Arm Type

    Active Comparator

    Active Comparator

    Arm Label

    One CLIP

    Two CLIPs

    Arm Description

    Implantation of single MitraClip

    Implantation of second MitraClip (after successful Implantation of single MitraClip)

    Outcomes

    Primary Outcome Measures

    Evaluation of number of participants who died death within one year
    death
    Evaluation of number of rehospitalizations due to heart failure among patients receiving one or two clips
    heart failure rehospitalization
    Evaluation of number of participants with recurrent regurgitation within one year
    recurrence of mitral regurgitation (>grade 2+ at 1 year)

    Secondary Outcome Measures

    death
    freedom from death (1-year)
    heart failure
    freedom from heart failure (1-year)
    rehospitalization
    rehospitalization
    regurgitation
    freedom from recurrence of mitral regurgitation (>2+; 1-year)
    success rate
    procedural success rate in 2-clip arm
    procedure duration
    procedure duration
    total device time
    total device time
    fluoroscopy time
    fluoroscopy time
    contrast volume
    contrast volume
    complications
    periprocedural (30-day) complications
    echocardiographic variables
    The following echocardiographic variables will be assessed by 2-dimensional transthoracic echocardiography at 12 months: Left ventricular (LV) end-diastolic diameter and volume; LV end-systolic diameter and volume; LV ejection fraction; LV outflow tract diameter and velocity time integral in LV outflow tract (to calculate forward stroke volume).
    changes in echocardiographic variables
    Changes from baseline to 12 months in echocardiographically assessed (at both time points) LV end-diastolic diameter and volume; LV end-systolic diameter and volume; LV ejection fraction; and forward stroke volume.
    NYHA
    NYHA functional class
    6-minutes walk
    6-minutes walk distance
    quality of life
    Assessment of the Minnesota Living With Heart Failure Questionnaire (MLHFQ) quality-of-life score. The questionnaire consists of 21 quality-of-life questions to be answered by the patient on a grading scale of 0 (best) to 5 (worst). Thus, the overall MLHFQ score ranges from 0 to 105.

    Full Information

    First Posted
    March 6, 2018
    Last Updated
    January 2, 2019
    Sponsor
    Asklepios proresearch
    Collaborators
    Abbott
    search

    1. Study Identification

    Unique Protocol Identification Number
    NCT03503851
    Brief Title
    Noninferiority Trial of MitraClip Implantation Strategies: 1 Clip vs. 2 Clips in Patients With Functional Mitral Regurgitation
    Acronym
    One-Plus-One
    Official Title
    Noninferiority Trial of MitraClip Implantation Strategies: 1 Clip vs. 2 Clips in Patients With Functional Mitral Regurgitation (One-Plus-One)
    Study Type
    Interventional

    2. Study Status

    Record Verification Date
    January 2019
    Overall Recruitment Status
    Withdrawn
    Why Stopped
    Delay during study initiation. Change of MitraClip design in meantime.
    Study Start Date
    May 2018 (Anticipated)
    Primary Completion Date
    November 2019 (Anticipated)
    Study Completion Date
    December 2020 (Anticipated)

    3. Sponsor/Collaborators

    Responsible Party, by Official Title
    Sponsor
    Name of the Sponsor
    Asklepios proresearch
    Collaborators
    Abbott

    4. Oversight

    Studies a U.S. FDA-regulated Drug Product
    No
    Studies a U.S. FDA-regulated Device Product
    No
    Data Monitoring Committee
    No

    5. Study Description

    Brief Summary
    Implantation of the MitraClip has become the most frequently used percutaneous technique to treat significant (grade 3+ or 4+) mitral regurgitation (MR) in elderly patients deemed inoperable or at high surgical risk. In Europe, about two-thirds of patients treated with the MitraClip suffer from MR of functional origin secondary to ischemic or dilated cardiomyopathy. At present, there is debate among operators on whether stabilizing/supporting a single adequately implanted clip with a second clip is beneficial for patients with functional MR.
    Detailed Description
    Implantation of the MitraClip has become the most frequently used percutaneous technique to treat significant (grade 3+ or 4+) mitral regurgitation (MR) in elderly patients deemed inoperable or at high surgical risk. In Europe, about two-thirds of patients treated with the MitraClip suffer from MR of functional origin secondary to ischemic or dilated cardiomyopathy. At present, there is debate among operators on whether stabilizing/supporting a single adequately implanted clip with a second clip is beneficial for patients with functional MR. Purpose To demonstrate the noninferiority of a 1-clip strategy vs. a 2-clip strategy of MitraClip implantation, when the second clip in the 2-clip study arm is implanted for stabilizing/supporting purposes.

    6. Conditions and Keywords

    Primary Disease or Condition Being Studied in the Trial, or the Focus of the Study
    Mitral Regurgitation Functional
    Keywords
    Mitral Regurgitation, transcatheter mitral valve repair, MitraClip

    7. Study Design

    Primary Purpose
    Treatment
    Study Phase
    Not Applicable
    Interventional Study Model
    Parallel Assignment
    Model Description
    Prospective, multi-center, randomized, parallel-arm trial
    Masking
    None (Open Label)
    Allocation
    Randomized
    Enrollment
    0 (Actual)

    8. Arms, Groups, and Interventions

    Arm Title
    One CLIP
    Arm Type
    Active Comparator
    Arm Description
    Implantation of single MitraClip
    Arm Title
    Two CLIPs
    Arm Type
    Active Comparator
    Arm Description
    Implantation of second MitraClip (after successful Implantation of single MitraClip)
    Intervention Type
    Device
    Intervention Name(s)
    MitraClip implantation
    Intervention Description
    Device to approximate the mitral valve leaflets
    Primary Outcome Measure Information:
    Title
    Evaluation of number of participants who died death within one year
    Description
    death
    Time Frame
    1 year
    Title
    Evaluation of number of rehospitalizations due to heart failure among patients receiving one or two clips
    Description
    heart failure rehospitalization
    Time Frame
    1 year
    Title
    Evaluation of number of participants with recurrent regurgitation within one year
    Description
    recurrence of mitral regurgitation (>grade 2+ at 1 year)
    Time Frame
    1 year
    Secondary Outcome Measure Information:
    Title
    death
    Description
    freedom from death (1-year)
    Time Frame
    1 year
    Title
    heart failure
    Description
    freedom from heart failure (1-year)
    Time Frame
    1 year
    Title
    rehospitalization
    Description
    rehospitalization
    Time Frame
    1-year
    Title
    regurgitation
    Description
    freedom from recurrence of mitral regurgitation (>2+; 1-year)
    Time Frame
    1-year
    Title
    success rate
    Description
    procedural success rate in 2-clip arm
    Time Frame
    1-year
    Title
    procedure duration
    Description
    procedure duration
    Time Frame
    1-year
    Title
    total device time
    Description
    total device time
    Time Frame
    1-year
    Title
    fluoroscopy time
    Description
    fluoroscopy time
    Time Frame
    1-year
    Title
    contrast volume
    Description
    contrast volume
    Time Frame
    1-year
    Title
    complications
    Description
    periprocedural (30-day) complications
    Time Frame
    1-year
    Title
    echocardiographic variables
    Description
    The following echocardiographic variables will be assessed by 2-dimensional transthoracic echocardiography at 12 months: Left ventricular (LV) end-diastolic diameter and volume; LV end-systolic diameter and volume; LV ejection fraction; LV outflow tract diameter and velocity time integral in LV outflow tract (to calculate forward stroke volume).
    Time Frame
    1-year
    Title
    changes in echocardiographic variables
    Description
    Changes from baseline to 12 months in echocardiographically assessed (at both time points) LV end-diastolic diameter and volume; LV end-systolic diameter and volume; LV ejection fraction; and forward stroke volume.
    Time Frame
    1-year
    Title
    NYHA
    Description
    NYHA functional class
    Time Frame
    1-year
    Title
    6-minutes walk
    Description
    6-minutes walk distance
    Time Frame
    1-year
    Title
    quality of life
    Description
    Assessment of the Minnesota Living With Heart Failure Questionnaire (MLHFQ) quality-of-life score. The questionnaire consists of 21 quality-of-life questions to be answered by the patient on a grading scale of 0 (best) to 5 (worst). Thus, the overall MLHFQ score ranges from 0 to 105.
    Time Frame
    1-year

    10. Eligibility

    Sex
    All
    Minimum Age & Unit of Time
    18 Years
    Accepts Healthy Volunteers
    No
    Eligibility Criteria
    Inclusion Criteria: Absence of a structural abnormality of the mitral valve giving rise to MR. MR severity of US grade 3+ or 4+ of central or noncentral origin Patient must consent to randomization in the hybrid operating theater upon successful implantation of a single MitraClip. Written informed consent must be provided prior to the MitraClip procedure. Exclusion Criteria: patients with primary regurgitation
    Overall Study Officials:
    First Name & Middle Initial & Last Name & Degree
    Karl-Heinz Kuck, MD, PHD
    Organizational Affiliation
    Asklepios Klinik St. Georg, Dept. of Cardiology
    Official's Role
    Principal Investigator

    12. IPD Sharing Statement

    Plan to Share IPD
    No
    Citations:
    PubMed Identifier
    26718672
    Citation
    Feldman T, Kar S, Elmariah S, Smart SC, Trento A, Siegel RJ, Apruzzese P, Fail P, Rinaldi MJ, Smalling RW, Hermiller JB, Heimansohn D, Gray WA, Grayburn PA, Mack MJ, Lim DS, Ailawadi G, Herrmann HC, Acker MA, Silvestry FE, Foster E, Wang A, Glower DD, Mauri L; EVEREST II Investigators. Randomized Comparison of Percutaneous Repair and Surgery for Mitral Regurgitation: 5-Year Results of EVEREST II. J Am Coll Cardiol. 2015 Dec 29;66(25):2844-2854. doi: 10.1016/j.jacc.2015.10.018.
    Results Reference
    background
    PubMed Identifier
    21463154
    Citation
    Feldman T, Foster E, Glower DD, Kar S, Rinaldi MJ, Fail PS, Smalling RW, Siegel R, Rose GA, Engeron E, Loghin C, Trento A, Skipper ER, Fudge T, Letsou GV, Massaro JM, Mauri L; EVEREST II Investigators. Percutaneous repair or surgery for mitral regurgitation. N Engl J Med. 2011 Apr 14;364(15):1395-406. doi: 10.1056/NEJMoa1009355. Epub 2011 Apr 4. Erratum In: N Engl J Med. 2011 Jul 14;365(2):189. Glower, Donald G [corrected to Glower, Donald D].
    Results Reference
    background
    PubMed Identifier
    20219746
    Citation
    Franzen O, Baldus S, Rudolph V, Meyer S, Knap M, Koschyk D, Treede H, Barmeyer A, Schofer J, Costard-Jackle A, Schluter M, Reichenspurner H, Meinertz T. Acute outcomes of MitraClip therapy for mitral regurgitation in high-surgical-risk patients: emphasis on adverse valve morphology and severe left ventricular dysfunction. Eur Heart J. 2010 Jun;31(11):1373-81. doi: 10.1093/eurheartj/ehq050. Epub 2010 Mar 10.
    Results Reference
    background
    PubMed Identifier
    22685268
    Citation
    Baldus S, Schillinger W, Franzen O, Bekeredjian R, Sievert H, Schofer J, Kuck KH, Konorza T, Mollmann H, Hehrlein C, Ouarrak T, Senges J, Meinertz T; German Transcatheter Mitral Valve Interventions (TRAMI) investigators. MitraClip therapy in daily clinical practice: initial results from the German transcatheter mitral valve interventions (TRAMI) registry. Eur J Heart Fail. 2012 Sep;14(9):1050-5. doi: 10.1093/eurjhf/hfs079. Epub 2012 Jun 8.
    Results Reference
    background
    PubMed Identifier
    23433761
    Citation
    Grasso C, Capodanno D, Scandura S, Cannata S, Imme S, Mangiafico S, Pistritto A, Ministeri M, Barbanti M, Caggegi A, Chiaranda M, Dipasqua F, Giaquinta S, Occhipinti M, Ussia G, Tamburino C. One- and twelve-month safety and efficacy outcomes of patients undergoing edge-to-edge percutaneous mitral valve repair (from the GRASP Registry). Am J Cardiol. 2013 May 15;111(10):1482-7. doi: 10.1016/j.amjcard.2013.01.300. Epub 2013 Feb 20.
    Results Reference
    background
    PubMed Identifier
    23343688
    Citation
    Surder D, Pedrazzini G, Gaemperli O, Biaggi P, Felix C, Rufibach K, der Maur CA, Jeger R, Buser P, Kaufmann BA, Moccetti M, Hurlimann D, Buhler I, Bettex D, Scherman J, Pasotti E, Faletra FF, Zuber M, Moccetti T, Luscher TF, Erne P, Grunenfelder J, Corti R. Predictors for efficacy of percutaneous mitral valve repair using the MitraClip system: the results of the MitraSwiss registry. Heart. 2013 Jul;99(14):1034-40. doi: 10.1136/heartjnl-2012-303105. Epub 2013 Jan 23.
    Results Reference
    background
    PubMed Identifier
    23747789
    Citation
    Maisano F, Franzen O, Baldus S, Schafer U, Hausleiter J, Butter C, Ussia GP, Sievert H, Richardt G, Widder JD, Moccetti T, Schillinger W. Percutaneous mitral valve interventions in the real world: early and 1-year results from the ACCESS-EU, a prospective, multicenter, nonrandomized post-approval study of the MitraClip therapy in Europe. J Am Coll Cardiol. 2013 Sep 17;62(12):1052-1061. doi: 10.1016/j.jacc.2013.02.094. Epub 2013 Jun 7.
    Results Reference
    background
    PubMed Identifier
    25169171
    Citation
    Nickenig G, Estevez-Loureiro R, Franzen O, Tamburino C, Vanderheyden M, Luscher TF, Moat N, Price S, Dall'Ara G, Winter R, Corti R, Grasso C, Snow TM, Jeger R, Blankenberg S, Settergren M, Tiroch K, Balzer J, Petronio AS, Buttner HJ, Ettori F, Sievert H, Fiorino MG, Claeys M, Ussia GP, Baumgartner H, Scandura S, Alamgir F, Keshavarzi F, Colombo A, Maisano F, Ebelt H, Aruta P, Lubos E, Plicht B, Schueler R, Pighi M, Di Mario C; Transcatheter Valve Treatment Sentinel Registry Investigators of the EURObservational Research Programme of the European Society of Cardiology. Percutaneous mitral valve edge-to-edge repair: in-hospital results and 1-year follow-up of 628 patients of the 2011-2012 Pilot European Sentinel Registry. J Am Coll Cardiol. 2014 Sep 2;64(9):875-84. doi: 10.1016/j.jacc.2014.06.1166.
    Results Reference
    background
    PubMed Identifier
    25601532
    Citation
    Eggebrecht H, Schelle S, Puls M, Plicht B, von Bardeleben RS, Butter C, May AE, Lubos E, Boekstegers P, Ouarrak T, Senges J, Schmermund A. Risk and outcomes of complications during and after MitraClip implantation: Experience in 828 patients from the German TRAnscatheter mitral valve interventions (TRAMI) registry. Catheter Cardiovasc Interv. 2015 Oct;86(4):728-35. doi: 10.1002/ccd.25838. Epub 2015 Feb 12.
    Results Reference
    background
    Links:
    URL
    https://www.ncbi.nlm.nih.gov/pubmed
    Description
    Related Info

    Learn more about this trial

    Noninferiority Trial of MitraClip Implantation Strategies: 1 Clip vs. 2 Clips in Patients With Functional Mitral Regurgitation

    We'll reach out to this number within 24 hrs