search
Back to results

Computer Guided Lag Screw Fixation Versus Conventional Lag Screw Fixation in Anterior Mandibular Fractures

Primary Purpose

Mandible Fracture

Status
Unknown status
Phase
Not Applicable
Locations
Egypt
Study Type
Interventional
Intervention
Computer guided lag screw fixation
Conventional lag screw fixation
Sponsored by
Cairo University
About
Eligibility
Locations
Arms
Outcomes
Full info

About this trial

This is an interventional treatment trial for Mandible Fracture focused on measuring anterior mandible fracture, surgery computer assisted

Eligibility Criteria

undefined - undefined (Child, Adult, Older Adult)All SexesDoes not accept healthy volunteers

Inclusion criteria:

  • Patients with anterior mandibular fracture indicated for open reduction internal fixation alone or in combination with fracture elsewhere in the mandible or mid face.
  • All ages and both sexes were included in this study.
  • Patients should be free from any systemic disease that may affect normal healing of bone, and predictable outcome.
  • Patients with good general condition allowing major surgical procedure under general anaesthesia .
  • Patients with physical and psychological tolerance.

Exclusion criteria:

  • Patients with comminuted fractures as it is not indicated for compression osteosynthesis like lag screws.
  • Patients with high risk systemic diseases like uncontrolled diabetes mellitus. As uncontrolled diabetes mellitus has a negative impact on normal bone healing.
  • Patients with old and/or mal-union fractures. As they will affect accuracy of reduction of the fractured segments.

Sites / Locations

  • Faculty of Oral and Dental Medicine - Cairo UniversityRecruiting

Arms of the Study

Arm 1

Arm 2

Arm Type

Experimental

Active Comparator

Arm Label

Computer guided lag screw fixation

Conventional lag screw fixation

Arm Description

Patient specific surgical guided will be used for open reduction and internal fixation for anterior mandibular fracture by lag screws.

Open reduction and internal fixation for anterior mandibular fracture using lag screws.

Outcomes

Primary Outcome Measures

Stability of fixed fractured segment
stability of fixed fractured segment will be assessed using measuring device bimanual manipulation, measuring unit (binary yes or no)

Secondary Outcome Measures

neurosensory disturbance
presence of neurosensory disturbance will be assessed using measuring device: subjective assessment, measuring unit (binary yes or no)
Accuracy of lag screw placement
Accuracy of lag screw placement will be assessed by measuring device: Computer aided surgical simulation (CASS) software, measuring unit: Millimetre
supplemental fixation devices
The need for intra operative or post operative supplemental fixation devices, measuring device clinical assessment. measuring unit: binary yes or no
Need for second surgery
The need for second surgical procedure will be assessed by clinical assessment (measuring device). measuring unit: binary (yes or no).

Full Information

First Posted
May 4, 2018
Last Updated
May 18, 2018
Sponsor
Cairo University
search

1. Study Identification

Unique Protocol Identification Number
NCT03530891
Brief Title
Computer Guided Lag Screw Fixation Versus Conventional Lag Screw Fixation in Anterior Mandibular Fractures
Official Title
Evaluation of the Efficacy of Computer Guided Lag Screw Fixation in Comparison to Conventional Lag Screw Fixation in Anterior Mandibular Fractures (RCT)
Study Type
Interventional

2. Study Status

Record Verification Date
May 2018
Overall Recruitment Status
Unknown status
Study Start Date
January 11, 2018 (Actual)
Primary Completion Date
March 1, 2019 (Anticipated)
Study Completion Date
June 1, 2019 (Anticipated)

3. Sponsor/Collaborators

Responsible Party, by Official Title
Principal Investigator
Name of the Sponsor
Cairo University

4. Oversight

Studies a U.S. FDA-regulated Drug Product
No
Studies a U.S. FDA-regulated Device Product
No
Data Monitoring Committee
Yes

5. Study Description

Brief Summary
Comparison between computer guided lag screw fixation versus traditional lag screw fixation in open reduction and internal fixation of anterior mandibular fractures.
Detailed Description
Two groups of patients with anterior mandibular fractures indicated for open reduction and internal fixation. First group will be subjected to computer guided lag screw fixation. Second group will be subjected to traditional lag screw fixation. Eligible patients will be randomised in equal proportions between study group (computer guided lag screw fixation) and control group (conventional lag screw fixation). A- Computer guided lag screw fixation group: Pre operative Computed tomography will be done for the patient. Computed tomography data will be imported into Computer aided surgical simulation software. Utilizing Computer aided surgical simulation software the fracture segments are virtually reduced and patient specific surgical guide is designed and sent to three dimension printer before operation. Intra operative: All cases will undergo surgery under general anaesthesia. Exposure of the fractured segments will be done using vestibular incision. Inter-maxillary fixation will be done The fractured segments will be reduced in normal anatomic position guided by occlusion. Fracture fragments will be fixed using lag screws utilizing patient specific surgical guide. Closure of the surgical incision. Post operative at first week Computed tomography will be done for the patient. Computed tomography data will be imported into computer aided surgical simulation software. Utilizing computer aided surgical simulation software the post operative computed tomography will be superimposed onto the pre operative planned simulation. B- Conventional titanium plates: Pre operative Computed tomography will be done for the patient. Computed tomography data will be imported into Computer aided surgical simulation software. Utilizing Computer aided surgical simulation software the fracture segments are virtually reduced. Intra operative: All cases will undergo surgery under general anaesthesia. Exposure of the fractured segments will be done using vestibular incision. Inter-maxillary fixation will be done. The fractured segments will be reduced in normal anatomic position guided by occlusion. The fracture fragments will be fixed using lag screws. Closure of the surgical incision. Post operative at first week Computed tomography will be done for the patient. Computed tomography data will be imported into computer aided surgical simulation software. Utilizing computer aided surgical simulation software the post operative computed tomography will be superimposed onto the pre operative planned simulation. Follow up for both groups: Clinical evaluation will be performed at first week postoperative then patients will be recalled every week for one month. Final follow up visit will be at 3 months post operative.

6. Conditions and Keywords

Primary Disease or Condition Being Studied in the Trial, or the Focus of the Study
Mandible Fracture
Keywords
anterior mandible fracture, surgery computer assisted

7. Study Design

Primary Purpose
Treatment
Study Phase
Not Applicable
Interventional Study Model
Parallel Assignment
Model Description
A Randomized clinical trial. Parallel group study. A trial will be carried out in hospital of Oral and Maxillofacial surgery department- Faculty of Oral and Dental Medicine Cairo University Equal randomization: participants with equal probabilities for intervention. Positive controlled: Both groups receiving treatment.
Masking
None (Open Label)
Masking Description
Because the two interventions requires different pre operative preparation, both the participants and investigators can't be blinded.
Allocation
Randomized
Enrollment
26 (Anticipated)

8. Arms, Groups, and Interventions

Arm Title
Computer guided lag screw fixation
Arm Type
Experimental
Arm Description
Patient specific surgical guided will be used for open reduction and internal fixation for anterior mandibular fracture by lag screws.
Arm Title
Conventional lag screw fixation
Arm Type
Active Comparator
Arm Description
Open reduction and internal fixation for anterior mandibular fracture using lag screws.
Intervention Type
Procedure
Intervention Name(s)
Computer guided lag screw fixation
Other Intervention Name(s)
computer assisted surgery
Intervention Description
Under general anaesthesia: Patient specific pre operative prefabricated surgical guide will be used intra operative for open reduction and internal fixation for anterior mandibular fracture using lag screws.
Intervention Type
Procedure
Intervention Name(s)
Conventional lag screw fixation
Other Intervention Name(s)
traditional lag screw fixation
Intervention Description
Under general anaesthesia: Open reduction and internal fixation for anterior mandibular fracture utilising lag screws.
Primary Outcome Measure Information:
Title
Stability of fixed fractured segment
Description
stability of fixed fractured segment will be assessed using measuring device bimanual manipulation, measuring unit (binary yes or no)
Time Frame
1st week post operative.
Secondary Outcome Measure Information:
Title
neurosensory disturbance
Description
presence of neurosensory disturbance will be assessed using measuring device: subjective assessment, measuring unit (binary yes or no)
Time Frame
one month post operative
Title
Accuracy of lag screw placement
Description
Accuracy of lag screw placement will be assessed by measuring device: Computer aided surgical simulation (CASS) software, measuring unit: Millimetre
Time Frame
1st week post operative.
Title
supplemental fixation devices
Description
The need for intra operative or post operative supplemental fixation devices, measuring device clinical assessment. measuring unit: binary yes or no
Time Frame
intra operative and one month post operative
Title
Need for second surgery
Description
The need for second surgical procedure will be assessed by clinical assessment (measuring device). measuring unit: binary (yes or no).
Time Frame
one month post operative

10. Eligibility

Sex
All
Accepts Healthy Volunteers
No
Eligibility Criteria
Inclusion criteria: Patients with anterior mandibular fracture indicated for open reduction internal fixation alone or in combination with fracture elsewhere in the mandible or mid face. All ages and both sexes were included in this study. Patients should be free from any systemic disease that may affect normal healing of bone, and predictable outcome. Patients with good general condition allowing major surgical procedure under general anaesthesia . Patients with physical and psychological tolerance. Exclusion criteria: Patients with comminuted fractures as it is not indicated for compression osteosynthesis like lag screws. Patients with high risk systemic diseases like uncontrolled diabetes mellitus. As uncontrolled diabetes mellitus has a negative impact on normal bone healing. Patients with old and/or mal-union fractures. As they will affect accuracy of reduction of the fractured segments.
Central Contact Person:
First Name & Middle Initial & Last Name or Official Title & Degree
Mohamed N Kadry, MSc
Phone
+201200560027
Email
m.kadry2011@gmail.com
Overall Study Officials:
First Name & Middle Initial & Last Name & Degree
Khaled S Amr, PhD
Organizational Affiliation
Faculty of oral and dental medicine, Cairo University.
Official's Role
Study Director
Facility Information:
Facility Name
Faculty of Oral and Dental Medicine - Cairo University
City
Giza
ZIP/Postal Code
12613
Country
Egypt
Individual Site Status
Recruiting
Facility Contact:
First Name & Middle Initial & Last Name & Degree
Mohamed N Kadry, MsC
Phone
+201200560027
Email
m.Kadry2011@gmail.com
First Name & Middle Initial & Last Name & Degree
Khaled S Amr, PHD
Phone
+201006029031
Email
khaledamr82@hotmail.com

12. IPD Sharing Statement

Plan to Share IPD
No
Citations:
PubMed Identifier
1985177
Citation
Ellis E 3rd, Ghali GE. Lag screw fixation of anterior mandibular fractures. J Oral Maxillofac Surg. 1991 Jan;49(1):13-21; discussion 21-2. doi: 10.1016/0278-2391(91)90259-o.
Results Reference
background
PubMed Identifier
22209100
Citation
Ellis E 3rd. Is lag screw fixation superior to plate fixation to treat fractures of the mandibular symphysis? J Oral Maxillofac Surg. 2012 Apr;70(4):875-82. doi: 10.1016/j.joms.2011.08.042. Epub 2011 Dec 30.
Results Reference
background
PubMed Identifier
8936514
Citation
Kallela I, Ilzuka T, Laine P, Lindqvist C. Lag-screw fixation of mandibular parasymphyseal and angle fractures. Oral Surg Oral Med Oral Pathol Oral Radiol Endod. 1996 Nov;82(5):510-6. doi: 10.1016/s1079-2104(96)80195-8.
Results Reference
background
PubMed Identifier
17236929
Citation
Xia JJ, Gateno J, Teichgraeber JF, Christensen AM, Lasky RE, Lemoine JJ, Liebschner MA. Accuracy of the computer-aided surgical simulation (CASS) system in the treatment of patients with complex craniomaxillofacial deformity: A pilot study. J Oral Maxillofac Surg. 2007 Feb;65(2):248-54. doi: 10.1016/j.joms.2006.10.005.
Results Reference
background
PubMed Identifier
8665308
Citation
Zachariades N, Mezitis M, Papademetriou I. Use of lag screws for the management of mandibular trauma. Oral Surg Oral Med Oral Pathol Oral Radiol Endod. 1996 Feb;81(2):164-7. doi: 10.1016/s1079-2104(96)80407-0.
Results Reference
background
PubMed Identifier
17517303
Citation
Tiwana PS, Kushner GM, Alpert B. Lag screw fixation of anterior mandibular fractures: a retrospective analysis of intraoperative and postoperative complications. J Oral Maxillofac Surg. 2007 Jun;65(6):1180-5. doi: 10.1016/j.joms.2006.11.046.
Results Reference
background
PubMed Identifier
3277107
Citation
Jones JK, Van Sickels JE. Rigid fixation: a review of concepts and treatment of fractures. Oral Surg Oral Med Oral Pathol. 1988 Jan;65(1):13-8. doi: 10.1016/0030-4220(88)90183-1.
Results Reference
background
PubMed Identifier
20465554
Citation
Retzepi M, Donos N. The effect of diabetes mellitus on osseous healing. Clin Oral Implants Res. 2010 Jul;21(7):673-81. doi: 10.1111/j.1600-0501.2010.01923.x. Epub 2010 May 3.
Results Reference
background
PubMed Identifier
24501458
Citation
Parashar A, Sharma RK. Unfavourable outcomes in maxillofacial injuries: How to avoid and manage. Indian J Plast Surg. 2013 May;46(2):221-34. doi: 10.4103/0970-0358.118597.
Results Reference
background

Learn more about this trial

Computer Guided Lag Screw Fixation Versus Conventional Lag Screw Fixation in Anterior Mandibular Fractures

We'll reach out to this number within 24 hrs