search
Back to results

Study Comparing Pancreatic EUS-FNB With the 20-gauge Procore® and the 22-gauge Acquire® Needles (HISTOPAN)

Primary Purpose

Pancreas Cancer, Pancreatic Adenocarcinoma

Status
Completed
Phase
Not Applicable
Locations
France
Study Type
Interventional
Intervention
20-GAUGE PROCORE® first, then 22-GAUGE ACQUIRE®
22-GAUGE ACQUIRE® first, then 20-GAUGE PROCORE®
Sponsored by
Société Française d'Endoscopie Digestive
About
Eligibility
Locations
Arms
Outcomes
Full info

About this trial

This is an interventional diagnostic trial for Pancreas Cancer

Eligibility Criteria

18 Years - 90 Years (Adult, Older Adult)All SexesDoes not accept healthy volunteers

Inclusion Criteria:

  • Patient admitted to one of the investigative centers for endoscopic pancreatic puncture during the period from April 1, 2018 to April 1, 2019
  • Patient whose age is greater than or equal to 18 years and less than 90 years
  • Patient ASA 1, ASA 2, ASA 3 (ASA: American Society of Anaesthesiologists Classification)
  • Lack of participation in another clinical study
  • Signed informed consent

Exclusion Criteria:

  • Patients punctured with an extra-pancreatic mass
  • Patient under the age of 18 or over 90
  • Patient ASA 4, ASA 5
  • Pregnant woman
  • Patient with coagulation abnormalities preventing puncture: TP <50%, Platelets <50000 / mm3, effective anticoagulation in progress, clopidogrel in progress
  • Vascular or ductal or surgical fixation (Billroth II, Roux in Y) preventing endoscopic access to the lesion to be punctured
  • Patient unable to personally consent

Sites / Locations

  • David Karsenti

Arms of the Study

Arm 1

Arm 2

Arm Type

Active Comparator

Active Comparator

Arm Label

Group A

Group B

Arm Description

The two punctures performed successively with the 20-GAUGE PROCORE® (COOK) and the 22-GAUGE ACQUIRE® (BOSTON SCIENTIFIC) 20-GAUGE PROCORE® first, then 22-GAUGE ACQUIRE®

The two punctures performed successively with the 22-GAUGE ACQUIRE® (BOSTON SCIENTIFIC) and the 20-GAUGE PROCORE® (COOK) 22-GAUGE ACQUIRE® first, then 20-GAUGE PROCORE®

Outcomes

Primary Outcome Measures

cumulative length of tissue core biopsies per needle pass
cumulative length of tissue core biopsies per needle pass in mm

Secondary Outcome Measures

Presence of core biopsy specimen
Presence of core biopsy specimen
Sensitivity
EUS-FNB Sensitivity for the diagnosis of adenocarcinoma of the pancreas
Specificity
EUS-FNB Specificity for the diagnosis of adenocarcinoma of the pancreas
Positive Predictive Value
EUS-FNB Positive predictive value for the diagnosis of adenocarcinoma of the pancreas
Negative Predictive Value
EUS-FNB Negative Predictive Value for the diagnosis of adenocarcinoma of the pancreas
Computer Aided Morphometric Evaluation of the Tumor + Stroma Surface
Computer Aided Morphometric Evaluation of the Tumor + Stroma Surface on All Core biopsies
Success rate of isolation of tumor cells
Success rate of isolation of tumor cells
Morbidity
Puncture Morbidity (acute pancreatitis, haemorrhage)
Feasibility
Technical failure rate of puncture because of a impossibility to access to pancreatic mass with the needle (due to the needle stiffness)
inter evaluation of the anatomopathological criteria used (presence of a biopsy core, length of target tissue core per needle pass)
inter evaluation of the anatomopathological criteria used (presence of a biopsy core, length of target tissue core per needle pass)
determination of transcriptomic signatures of pancreatic adenocarcinoma subtypes
determination of transcriptomic signatures of pancreatic adenocarcinoma subtypes
intra-observer evaluation of the anatomopathological criteria used
intra-observer evaluation of the anatomopathological criteria used

Full Information

First Posted
May 29, 2018
Last Updated
September 29, 2019
Sponsor
Société Française d'Endoscopie Digestive
search

1. Study Identification

Unique Protocol Identification Number
NCT03567863
Brief Title
Study Comparing Pancreatic EUS-FNB With the 20-gauge Procore® and the 22-gauge Acquire® Needles
Acronym
HISTOPAN
Official Title
Multicentric Randomized Study Comparing the Histological and Molecular Material Quality Obtained by EUS-FNB of Pancreatic Mass With Two "Biopsic" Needles: the 20-gauge Procore® (Cook) and the 22-gauge Acquire® (Boston Scientific)
Study Type
Interventional

2. Study Status

Record Verification Date
September 2019
Overall Recruitment Status
Completed
Study Start Date
June 24, 2018 (Actual)
Primary Completion Date
September 29, 2019 (Actual)
Study Completion Date
September 29, 2019 (Actual)

3. Sponsor/Collaborators

Responsible Party, by Official Title
Principal Investigator
Name of the Sponsor
Société Française d'Endoscopie Digestive

4. Oversight

Studies a U.S. FDA-regulated Drug Product
No
Studies a U.S. FDA-regulated Device Product
No
Data Monitoring Committee
No

5. Study Description

Brief Summary
Multicenter randomized prospective study Criteria for inclusion: Patients admitted for EUS-FNB of a pancreatic mass Goals of the study: To compare the results of blinded punctures for suspicion of pancreatic tumor performed under endoscopic ultrasound in our center (Digestive Endoscopy Unit of the Digestive Pole Paris Bercy, PDPB), in terms of diagnosis and quality of histopathological material obtained with the help of 20G Procore, Cook and 22G Acquire needles, Boston Scientific. Main criterion: - Biopsy core length of target tissue obtained by needle pass Number of patients: 60 patients Duration of the study: 1 year
Detailed Description
Type of study: Multicenter randomized prospective study Criteria for inclusion: Patients admitted for ENDOSCOPIC ULTRASOUND FINE NEEDLE BIOPSY (EUS-FNB) of a pancreatic mass Exclusion criteria: Patients with an extra-pancreatic mass puncture Echendoscopic puncture contraindication or vascular interposition Goals of the study: To compare the results of blinded punctures for suspicion of pancreatic tumor performed under endoscopic ultrasound in our center (Digestive Endoscopy Unit of the Digestive Pole Paris Bercy, PDPB), in terms of diagnosis and quality of histopathological material obtained with the help of 20G Procore, Cook and 22G Acquire needles, Boston Scientific. Evaluation criteria : Main criterion: - Biopsy core length of target tissue obtained by needle pass Secondary criteria Presence of a core biopsy specimen Sensitivity of EUS-FNB for the diagnosis of adenocarcinoma of the pancreas False negative rate, Negative predictive value for the diagnosis of pancreatic adenocarcinoma Computer Aided Morphometric Evaluation of the Tumor + Stroma Surface on All core biopsy specimens Success rate of isolation of tumor cells and determination of transcriptomic signatures of pancreatic adenocarcinoma subtypes Immediate complications of puncture Variation in the quality of the puncture following the trans-duodenal or trans-gastric access route Technical failure rate of puncture Optional: inter and intra-observer evaluation of the anatomopathological criteria used (presence of a biopsy core, length of target tissue core per needle passage) Number of patients: 60 patients Duration of the study: 1 year

6. Conditions and Keywords

Primary Disease or Condition Being Studied in the Trial, or the Focus of the Study
Pancreas Cancer, Pancreatic Adenocarcinoma

7. Study Design

Primary Purpose
Diagnostic
Study Phase
Not Applicable
Interventional Study Model
Sequential Assignment
Masking
ParticipantInvestigator
Masking Description
the order of use of the 2 needles is not communicated to the cytologist
Allocation
Randomized
Enrollment
60 (Actual)

8. Arms, Groups, and Interventions

Arm Title
Group A
Arm Type
Active Comparator
Arm Description
The two punctures performed successively with the 20-GAUGE PROCORE® (COOK) and the 22-GAUGE ACQUIRE® (BOSTON SCIENTIFIC) 20-GAUGE PROCORE® first, then 22-GAUGE ACQUIRE®
Arm Title
Group B
Arm Type
Active Comparator
Arm Description
The two punctures performed successively with the 22-GAUGE ACQUIRE® (BOSTON SCIENTIFIC) and the 20-GAUGE PROCORE® (COOK) 22-GAUGE ACQUIRE® first, then 20-GAUGE PROCORE®
Intervention Type
Device
Intervention Name(s)
20-GAUGE PROCORE® first, then 22-GAUGE ACQUIRE®
Intervention Description
The two punctures performed successively with the 20-GAUGE PROCORE® (COOK) and the 22-GAUGE ACQUIRE® (BOSTON SCIENTIFIC)
Intervention Type
Device
Intervention Name(s)
22-GAUGE ACQUIRE® first, then 20-GAUGE PROCORE®
Intervention Description
The two punctures performed successively with the 22-GAUGE ACQUIRE® (BOSTON SCIENTIFIC) and the 20-GAUGE PROCORE® (COOK)
Primary Outcome Measure Information:
Title
cumulative length of tissue core biopsies per needle pass
Description
cumulative length of tissue core biopsies per needle pass in mm
Time Frame
in the 7 days after procedure
Secondary Outcome Measure Information:
Title
Presence of core biopsy specimen
Description
Presence of core biopsy specimen
Time Frame
in the 7 days after procedure
Title
Sensitivity
Description
EUS-FNB Sensitivity for the diagnosis of adenocarcinoma of the pancreas
Time Frame
in the 7 days or 6 months
Title
Specificity
Description
EUS-FNB Specificity for the diagnosis of adenocarcinoma of the pancreas
Time Frame
in the 7 days or 6 months
Title
Positive Predictive Value
Description
EUS-FNB Positive predictive value for the diagnosis of adenocarcinoma of the pancreas
Time Frame
in the 7 days or 6 months
Title
Negative Predictive Value
Description
EUS-FNB Negative Predictive Value for the diagnosis of adenocarcinoma of the pancreas
Time Frame
in the 7 days or 6 months
Title
Computer Aided Morphometric Evaluation of the Tumor + Stroma Surface
Description
Computer Aided Morphometric Evaluation of the Tumor + Stroma Surface on All Core biopsies
Time Frame
6 months
Title
Success rate of isolation of tumor cells
Description
Success rate of isolation of tumor cells
Time Frame
6 months
Title
Morbidity
Description
Puncture Morbidity (acute pancreatitis, haemorrhage)
Time Frame
7 days
Title
Feasibility
Description
Technical failure rate of puncture because of a impossibility to access to pancreatic mass with the needle (due to the needle stiffness)
Time Frame
during procedure
Title
inter evaluation of the anatomopathological criteria used (presence of a biopsy core, length of target tissue core per needle pass)
Description
inter evaluation of the anatomopathological criteria used (presence of a biopsy core, length of target tissue core per needle pass)
Time Frame
7 days
Title
determination of transcriptomic signatures of pancreatic adenocarcinoma subtypes
Description
determination of transcriptomic signatures of pancreatic adenocarcinoma subtypes
Time Frame
6 months
Title
intra-observer evaluation of the anatomopathological criteria used
Description
intra-observer evaluation of the anatomopathological criteria used
Time Frame
7 days

10. Eligibility

Sex
All
Minimum Age & Unit of Time
18 Years
Maximum Age & Unit of Time
90 Years
Accepts Healthy Volunteers
No
Eligibility Criteria
Inclusion Criteria: Patient admitted to one of the investigative centers for endoscopic pancreatic puncture during the period from April 1, 2018 to April 1, 2019 Patient whose age is greater than or equal to 18 years and less than 90 years Patient ASA 1, ASA 2, ASA 3 (ASA: American Society of Anaesthesiologists Classification) Lack of participation in another clinical study Signed informed consent Exclusion Criteria: Patients punctured with an extra-pancreatic mass Patient under the age of 18 or over 90 Patient ASA 4, ASA 5 Pregnant woman Patient with coagulation abnormalities preventing puncture: TP <50%, Platelets <50000 / mm3, effective anticoagulation in progress, clopidogrel in progress Vascular or ductal or surgical fixation (Billroth II, Roux in Y) preventing endoscopic access to the lesion to be punctured Patient unable to personally consent
Overall Study Officials:
First Name & Middle Initial & Last Name & Degree
David Karsenti, MD
Organizational Affiliation
Société Française d'Endoscopie Digestive
Official's Role
Principal Investigator
Facility Information:
Facility Name
David Karsenti
City
Charenton-le-Pont
State/Province
Ile De France
ZIP/Postal Code
94220
Country
France

12. IPD Sharing Statement

Plan to Share IPD
No
Citations:
PubMed Identifier
36255027
Citation
Chen TY, Cao JW, Jin C, Ji Y, Zhong L, Wang LM, Cui N, Di Y, Bao Y, Zhong N, Zhang YQ, Zhou PH. Comparison of specimen quality among the standard suction, slow-pull, and wet suction techniques for EUS-FNA: A multicenter, prospective, randomized controlled trial. Endosc Ultrasound. 2022 Sep-Oct;11(5):393-400. doi: 10.4103/EUS-D-21-00163.
Results Reference
derived
PubMed Identifier
36216266
Citation
Ishikawa H, Yamada M, Sato Y, Tanaka S, Akiko C, Tajika M, Doyama H, Takayama T, Ohda Y, Horimatsu T, Sano Y, Tanakaya K, Ikematsu H, Saida Y, Ishida H, Takeuchi Y, Kashida H, Kiriyama S, Hori S, Lee K, Tashiro J, Kobayashi N, Nakajima T, Suzuki S, Mutoh M; J-FAPP Study III Group. Intensive endoscopic resection for downstaging of polyp burden in patients with familial adenomatous polyposis (J-FAPP Study III): a multicenter prospective interventional study. Endoscopy. 2023 Apr;55(4):344-352. doi: 10.1055/a-1945-9120. Epub 2022 Oct 10.
Results Reference
derived
PubMed Identifier
35708359
Citation
Chen TY, Cao JW, Jin C, Ji Y, Zhong L, Wang LM, Cui N, Di Y, Bao Y, Zhong N, Zhang YQ, Zhou PH. Comparison of specimen quality among the standard suction, slow-pull, and wet suction techniques for EUS-FNA: A multicenter, prospective, randomized controlled trial. Endosc Ultrasound. 2022 Jun 8. doi: 10.4103/EUS-D-21-00163. Online ahead of print.
Results Reference
derived
PubMed Identifier
34905795
Citation
Motz VL, Lester C, Moyer MT, Maranki JL, Levenick JM. Hybrid argon plasma coagulation-assisted endoscopic mucosal resection for large sessile colon polyps to reduce local recurrence: a prospective pilot study. Endoscopy. 2022 Jun;54(6):580-584. doi: 10.1055/a-1677-3954. Epub 2021 Dec 14.
Results Reference
derived
PubMed Identifier
33285582
Citation
Park E, Barge W, Kramer J, Alajati B, Jakate S, Cimbaluk D, Giusto D, Ritz E, Bishehsari F, Lee S, Singh S, Losurdo J, Brown M, DeMeo M, Abraham R, Ma K, Melson J. Interobserver reliability of methods to determine complete resection of adenomas in colonoscopy. Endoscopy. 2021 Dec;53(12):1250-1255. doi: 10.1055/a-1331-4446. Epub 2021 Feb 18.
Results Reference
derived
PubMed Identifier
33264811
Citation
de Benito Sanz M, Hernandez L, Garcia Martinez MI, Diez-Redondo P, Joao Matias D, Gonzalez-Santiago JM, Ibanez M, Nunez Rodriguez MH, Cimavilla M, Tafur C, Mata L, Guardiola-Arevalo A, Feito J, Garcia-Alonso FJ; POLIPEC HOT-COLD Study Group. Efficacy and safety of cold versus hot snare polypectomy for small (5-9 mm) colorectal polyps: a multicenter randomized controlled trial. Endoscopy. 2022 Jan;54(1):35-44. doi: 10.1055/a-1327-8357. Epub 2021 Feb 18. Erratum In: Endoscopy. 2021 Nov 30;:
Results Reference
derived
PubMed Identifier
32906162
Citation
Nakamura M, Yano T, Esaki M, Oka S, Mitsui K, Hirai F, Kawasaki K, Fujishiro M, Torisu T, Tanaka S, Iwakiri K, Kishi M, Matsumoto T, Yamamoto H. Novel ultrathin double-balloon endoscopy for the diagnosis of small-bowel diseases: a multicenter nonrandomized study. Endoscopy. 2021 Aug;53(8):802-814. doi: 10.1055/a-1243-0226. Epub 2020 Sep 9.
Results Reference
derived
PubMed Identifier
32869230
Citation
Meng W, Yue P, Leung JW, Wang H, Wang X, Wang F, Zhu K, Zhang L, Zhu X, Wang Z, Zhang H, Zhou W, Li X. Impact of mechanical simulator practice on clinical ERCP performance by novice surgical trainees: a randomized controlled trial. Endoscopy. 2020 Nov;52(11):1004-1013. doi: 10.1055/a-1217-6727. Epub 2020 Aug 31.
Results Reference
derived
PubMed Identifier
32693411
Citation
Kovacevic B, Klausen P, Rift CV, Toxvaerd A, Grossjohann H, Karstensen JG, Brink L, Hassan H, Kalaitzakis E, Storkholm J, Hansen CP, Hasselby JP, Vilmann P. Clinical impact of endoscopic ultrasound-guided through-the-needle microbiopsy in patients with pancreatic cysts. Endoscopy. 2021 Jan;53(1):44-52. doi: 10.1055/a-1214-6043. Epub 2020 Jul 21.
Results Reference
derived
PubMed Identifier
32679602
Citation
Subramaniam S, Kandiah K, Chedgy F, Fogg C, Thayalasekaran S, Alkandari A, Baker-Moffatt M, Dash J, Lyons-Amos M, Longcroft-Wheaton G, Brown J, Bhandari P. A novel self-assembling peptide for hemostasis during endoscopic submucosal dissection: a randomized controlled trial. Endoscopy. 2021 Jan;53(1):27-35. doi: 10.1055/a-1198-0558. Epub 2020 Jul 17.
Results Reference
derived
PubMed Identifier
32668474
Citation
Zhang Y, Liu L, Wang Q, Guo L, Ye L, Zeng H, Zeng X, Yuan X, Li Y, Zhang Y, Zhou E, Hu B. Endoscopic submucosal dissection with additional radiotherapy in the treatment of T1a esophageal squamous cell cancer: randomized controlled Trial. Endoscopy. 2020 Dec;52(12):1066-1074. doi: 10.1055/a-1198-5232. Epub 2020 Jul 15.
Results Reference
derived
PubMed Identifier
32650346
Citation
Seicean A, Samarghitan A, Bolboaca SD, Pojoga C, Rusu I, Rusu D, Sparchez Z, Gheorghiu M, Al Hajjar N, Seicean R. Contrast-enhanced harmonic versus standard endoscopic ultrasound-guided fine-needle aspiration in solid pancreatic lesions: a single-center prospective randomized trial. Endoscopy. 2020 Dec;52(12):1084-1090. doi: 10.1055/a-1193-4954. Epub 2020 Jul 10.
Results Reference
derived
PubMed Identifier
32557475
Citation
Alvarez-Gonzalez MA, Pantaleon Sanchez MA, Bernad Cabredo B, Garcia-Rodriguez A, Frago Larramona S, Nogales O, Diez Redondo P, Puig Del Castillo I, Romero Mascarell C, Caballero N, Romero Sanchez-Miguel I, Perez Berbegal R, Hernandez Negrin D, Bujedo Sadornill G, Perez Oltra A, Casals Urquiza G, Amoros Martinez J, Seoane Urgorri A, Ibanez Zafon IA, Gimeno-Garcia AZ. Educational nurse-led telephone intervention shortly before colonoscopy as a salvage strategy after previous bowel preparation failure: a multicenter randomized trial. Endoscopy. 2020 Nov;52(11):1026-1035. doi: 10.1055/a-1178-9844. Epub 2020 Jun 17.
Results Reference
derived
PubMed Identifier
32515006
Citation
Struyvenberg M, Kahn A, Fleischer D, Swager AF, Bouma B, Ganguly EK, Konda V, Lightdale CJ, Pleskow D, Sethi A, Smith M, Trindade AJ, Wallace MB, Wang K, Wolfsen HC, Tearney GJ, Curvers WL, Leggett CL, Bergman JJ. Expert assessment on volumetric laser endomicroscopy full scans in Barrett's esophagus patients with or without high grade dysplasia or early cancer. Endoscopy. 2021 Mar;53(3):218-225. doi: 10.1055/a-1194-0397. Epub 2020 Jun 17.
Results Reference
derived
PubMed Identifier
32498100
Citation
Zwager LW, Bastiaansen BAJ, Bronzwaer MES, van der Spek BW, Heine GDN, Haasnoot KJC, van der Sluis H, Perk LE, Boonstra JJ, Rietdijk ST, Wolters HJ, Weusten BLAM, Gilissen LPL, Ten Hove WR, Nagengast WB, Bekkering FC, Schwartz MP, Terhaar Sive Droste JS, Vlug MS, Houben MHMG, Rando Munoz FJ, Seerden TCJ, Beaumont H, de Ridder R, Dekker E, Fockens P; Dutch eFTR Group. Endoscopic full-thickness resection (eFTR) of colorectal lesions: results from the Dutch colorectal eFTR registry. Endoscopy. 2020 Nov;52(11):1014-1023. doi: 10.1055/a-1176-1107. Epub 2020 Jun 4.
Results Reference
derived
PubMed Identifier
32408361
Citation
Karsenti D, Palazzo L, Perrot B, Zago J, Lemaistre AI, Cros J, Napoleon B. 22G Acquire vs. 20G Procore needle for endoscopic ultrasound-guided biopsy of pancreatic masses: a randomized study comparing histologic sample quantity and diagnostic accuracy. Endoscopy. 2020 Sep;52(9):747-753. doi: 10.1055/a-1160-5485. Epub 2020 May 14.
Results Reference
derived

Learn more about this trial

Study Comparing Pancreatic EUS-FNB With the 20-gauge Procore® and the 22-gauge Acquire® Needles

We'll reach out to this number within 24 hrs