Study to Evaluate the Reliability and Validity of the Modified Manual Muscle Test for Persons With MS
Primary Purpose
Multiple Sclerosis
Status
Completed
Phase
Not Applicable
Locations
Switzerland
Study Type
Interventional
Intervention
Modified Manual Muscle Test
BMRC manual muscle test
MicroFET2 handhold dynamometer
Modified Tardieu Scale
Fatigue Scale for Motor and Cognitive Functions
numeric rating scale Fatigue
Sponsored by

About this trial
This is an interventional diagnostic trial for Multiple Sclerosis
Eligibility Criteria
Inclusion Criteria
- diagnosed with MS according to the McDonald criteria
- EDSS between 0 and 6.5
- older than 18 years of age.
Exclusion Criteria:
- An acute episode of MS within 3 months prior to the testing,
- grave cognitive changes
- distinct fatigue
- a history of current back, neck or elbow pain
Sites / Locations
- Felix Platter Hospital
Arms of the Study
Arm 1
Arm 2
Arm 3
Arm Type
Active Comparator
Active Comparator
Active Comparator
Arm Label
Modified Manual Muscle Test
Neurostatus BMRC
MicroFET2
Arm Description
The MMMT will be tested in a test-retest design
The Neurostatus BMRC measures Strength and will be used in a test-retest design
The MicroFET2 is a hand held dynamometer to measure strength
Outcomes
Primary Outcome Measures
Inter-rater reliability Modified Manual Muscle Test
The primary endpoint is the MMMT level. The ordinal levels (2+, 3-, 3, 4-, 4, 4+ and 5) will be transformed to ranks (1-7), and the intra-class correlation coefficient (ICC) of the ranked MMMT levels will be estimated. The aim is to show that the MMMT results are at a clinically relevant - thus high - level of ICC (that is a pre-specified, clinically relevant level the ICC margin).
The null hypothesis is that the lower limit of the 95% confidence interval (CI) of the ICC is smaller than or equal to the ICC margin. The alternative hypothesis is that the lower limit of the 95% CI of the ICC is larger than the ICC margin.
If the lower limit of the CI is larger than the ICC margin, the MMMT will be considered a reliable tool for evaluating muscle strength in MS patients.
Secondary Outcome Measures
Intra-rater reliability Modified Manual Muscle Test
The intra-rater reliability will be evaluated by comparing the test results of two tests (test-retest), which will be executed by the same tester. The two tests will be executed on the same day within 4 hours. The intra-class correlation coefficient of the ranked MMMT levels (analogue to the primary endpoint) will be used to describe the intra-rater reliability of the MMMT.
Validity of the Modified Manual Muscle Test
The inter-rater reliability of the BMRC will be measured by the ICC. The ICC of the BMRC will be estimated and analysed as previously described for the primary analysis. The ICCs of the MMMT and the BMRC will be compared descriptively.
The test-retest reliability of the MMMT and the BMRC will be estimated for each rater separately using a two-way random-effects ANOVA, including the patient and "test type" (test/retest) as random effects. The ICC estimates will be reported with the 95% CI and compared descriptively between the raters using the same test and between the tests (MMMT vs BMRC).
The pairwise correlations of the MMMT and the BMRC with the muscle strength as assessed by the microFET2 will be investigated graphically (scatterplots and/or boxplots). Furthermore, Spearman's rank correlation coefficient will be presented with the corresponding 95% CI and p-values.
Modified Tardieu Scale level
The BMRC has 6 levels, which makes the scale robust and reliable but insensitive to change. In addition, the BMRC does not consider spasticity. The MMMT has 12 levels, which makes it more sensitive, but it also might mean that the scale is less reliable. Because the MMMT considers spasticity, we expect that this compensates for the possible loss of reliability. It is assumed that the MMMT is less sensitive to spasticity than the BMRC. Thus, for patients with a different level of spasticity measured by the Modified Tardieu Scale, both the inter-rater and the test-retest reliability of the MMMT are expected to be equal to those of the BMRC.
The primary and secondary analyses will thus be repeated for the subgroups of high-spasticity and low-spasticity patients separately (assuming that a reasonable number of patients per subgroup and endpoint are available).
Full Information
NCT ID
NCT03603691
First Posted
June 19, 2018
Last Updated
January 29, 2019
Sponsor
Nanco van der Maas
Collaborators
University Hospital, Basel, Switzerland, Physiotherapie Langmatten Binningen, Switzerland, Clinical Trial Unit, University Hospital Basel, Switzerland
1. Study Identification
Unique Protocol Identification Number
NCT03603691
Brief Title
Study to Evaluate the Reliability and Validity of the Modified Manual Muscle Test for Persons With MS
Official Title
A Single-centre, Prospective, Cross-sectional Study to Evaluate the Reliability and Validity of the Modified Manual Muscle Test for Persons With Multiple Sclerosis) (MS)
Study Type
Interventional
2. Study Status
Record Verification Date
January 2019
Overall Recruitment Status
Completed
Study Start Date
August 1, 2018 (Actual)
Primary Completion Date
December 15, 2018 (Actual)
Study Completion Date
January 29, 2019 (Actual)
3. Sponsor/Collaborators
Responsible Party, by Official Title
Sponsor-Investigator
Name of the Sponsor
Nanco van der Maas
Collaborators
University Hospital, Basel, Switzerland, Physiotherapie Langmatten Binningen, Switzerland, Clinical Trial Unit, University Hospital Basel, Switzerland
4. Oversight
Studies a U.S. FDA-regulated Drug Product
No
Studies a U.S. FDA-regulated Device Product
No
Data Monitoring Committee
Yes
5. Study Description
Brief Summary
Many patients with multiple sclerosis (MS) are treated with physiotherapy. Muscle weakness is a common symptom. It can be evaluated with a variety of muscle function tests. In MS patients, testing muscle function can be confounded by many factors, such as spasticity and ataxia, which are not considered by the existing tests and may cause biased test results. Steinlin Egli described a Modified Manual Muscle Test (MMMT) that considers spasticity and may provide a more reliable and valid muscle function test for MS patients.
The investigators aim to evaluate the inter- and intra-rater reliability of the Modified Manual Muscle Test in MS and evaluate the validity of the Modified MMT according to the criteria of the 6 level British Medical Research Council (BMRC) manual muscle test and the microFET2 handhold dynamometer.
Detailed Description
Background In Switzerland, many patients with multiple sclerosis (MS) are treated with physiotherapy. Muscle weakness is a common symptom. Particularly in progressive disease courses, motor dysfunction is a major contributor to the reduced mobility and quality of life. Therefore, improving the motor dysfunction is an important goal for therapy and is evaluated with a variety of muscle function tests. The 6 level British Medical Research Council (BMRC) manual muscle test is the most widely used test in MS and is a part of the Neurostatus-Expanded Disability Status Scale (EDSS) assessment, which has been adopted as the standard in most of the pivotal trials that have led to the approval of the current MS treatments. In MS patients, testing muscle function can be confounded by many factors, such as spasticity and ataxia, which are not considered by the existing tests and may cause biased test results. Steinlin Egli described a Modified Manual Muscle Test (MMMT) that considers spasticity and may provide a more reliable and valid muscle function test for MS patients.
Aim of the study is to evaluate the inter- and intra-rater reliability of the Modified Manual Muscle Test in MS and evaluate the validity of the Modified MMT according to the criteria of the Neurostatus BMRC manual muscle test and the microFET2 handhold dynamometer.
Methods This is a single-centre, prospective cross-sectional study with a test-retest design. The Neurostatus BMRC manual muscle test and the microFET2 hand held dynamometer are used as the criteria. The primary endpoint is the ordinal MMMT level. The intra-class correlation coefficient (ICC) of the ranked MMMT levels will be estimated. The investigator aims to show that the MMMT results are clinically relevant with a high level of ICC.
The secondary endpoints include the Neurostatus BMRC levels, the muscle strength as measured by the microFET2 dynamometer and fatigue using a numeric rating scale (NRS). Subgroup analyses will determine whether the MMMT is less sensitive to the influence of spasticity than the Neurostatus BMRC.
28 patients with MS will be tested in 2 days. In each day, six examiners will test seven patients in the morning and seven patients in the afternoon. Three MS-therapists from the Specialized Group Physiotherapy in MS and three neurologists from the Department of Neurology at the University Hospital Basel will be tester. All examiners will be blinded to the results of the other examiners. All test persons will be blinded to their test results. First, the patient will rate his fatigue using the NRS. Muscle function will be tested with the microFET2 and spasticity will be assessed using the modified Tardieu Scale. Then, the first round of manual testing will be executed. After each test, there will be a break that is long enough for the patients to recuperate. The order of the examiners will be randomized. The retest round will proceed in a different order. Finally, spasticity will be tested again using the modified Tardieu Scale, and the patients will rate their fatigue.
Statistical Analysis The study data will be analysed using the internet-based program R. The descriptive statistics will describe the sample characteristics. The inter-rater reliability will be estimated by the ICC of the MMMT ranks. The ICC will be estimated by a two-way random-effects ANOVA and reported with 95% CI. If the lower limit of the CI is larger than the pre-specified clinically relevant ICC margin, the MMMT will be considered a reliable tool for evaluating muscle strength in MS patients.
The inter-rater reliability the Neurostatus BMRC will be estimated similarly by the ICC. The ICC of both tests will be compared. The test-retest reliability of the MMMT and Neurostatus BMRC will be estimated using two-way random-effects ANOVA and will be reported by ICC estimates. The influence of potential fatigue will be analysed by plotting the test and retest results against the NRS and investigating the associations and interactions using a linear mixed effects model. The pairwise correlations of the MMMT and the Neurostatus BMRC with the microFET2 will be graphically analysed (scatterplots and/or boxplots), and Spearman's ρ will be calculated. The primary and secondary analyses will be repeated for subgroups with high and low spasticity patients to compare the sensitivity of the MMMT and Neurostatus BMRC to spasticity.
Expected results: The investigators expect the MMMT for MS to be a reliable and valid manual muscle function test that can be used in the evaluation of the long-term treatment of MS patients with physical therapy.
6. Conditions and Keywords
Primary Disease or Condition Being Studied in the Trial, or the Focus of the Study
Multiple Sclerosis
7. Study Design
Primary Purpose
Diagnostic
Study Phase
Not Applicable
Interventional Study Model
Crossover Assignment
Model Description
Prospective, cross-sectional and test-retest
Masking
Outcomes Assessor
Masking Description
the outcome assessors will be blinded for the results of other assessors.
Allocation
Randomized
Enrollment
28 (Actual)
8. Arms, Groups, and Interventions
Arm Title
Modified Manual Muscle Test
Arm Type
Active Comparator
Arm Description
The MMMT will be tested in a test-retest design
Arm Title
Neurostatus BMRC
Arm Type
Active Comparator
Arm Description
The Neurostatus BMRC measures Strength and will be used in a test-retest design
Arm Title
MicroFET2
Arm Type
Active Comparator
Arm Description
The MicroFET2 is a hand held dynamometer to measure strength
Intervention Type
Diagnostic Test
Intervention Name(s)
Modified Manual Muscle Test
Intervention Description
Manual Muscle Testing Grading System from 0=No visible or palpable contraction to 5= full range of movement against gravity, maximal resistance
Intervention Type
Diagnostic Test
Intervention Name(s)
BMRC manual muscle test
Intervention Description
muscle scale grades muscle power on a scale of 0 to 5 in relation to the maximum expected for that muscle
Intervention Type
Diagnostic Test
Intervention Name(s)
MicroFET2 handhold dynamometer
Intervention Description
MicroFET 2 Handheld Dynamometer is a force evaluation testing device to evaluate the strength of various muscle groups
Intervention Type
Diagnostic Test
Intervention Name(s)
Modified Tardieu Scale
Intervention Description
Modified Tardieu Scale is to measure if there is spasticity present in a person's muscle and its response to movement
Intervention Type
Diagnostic Test
Intervention Name(s)
Fatigue Scale for Motor and Cognitive Functions
Intervention Description
Measures cognitive and motor fatigue for people with MS
Intervention Type
Diagnostic Test
Intervention Name(s)
numeric rating scale Fatigue
Intervention Description
visual analog scale that uses a scalar numbering system to objectify a patient's fatigue (0 = no fatigue; 10 = most extreme fatigue)
Primary Outcome Measure Information:
Title
Inter-rater reliability Modified Manual Muscle Test
Description
The primary endpoint is the MMMT level. The ordinal levels (2+, 3-, 3, 4-, 4, 4+ and 5) will be transformed to ranks (1-7), and the intra-class correlation coefficient (ICC) of the ranked MMMT levels will be estimated. The aim is to show that the MMMT results are at a clinically relevant - thus high - level of ICC (that is a pre-specified, clinically relevant level the ICC margin).
The null hypothesis is that the lower limit of the 95% confidence interval (CI) of the ICC is smaller than or equal to the ICC margin. The alternative hypothesis is that the lower limit of the 95% CI of the ICC is larger than the ICC margin.
If the lower limit of the CI is larger than the ICC margin, the MMMT will be considered a reliable tool for evaluating muscle strength in MS patients.
Time Frame
Baseline
Secondary Outcome Measure Information:
Title
Intra-rater reliability Modified Manual Muscle Test
Description
The intra-rater reliability will be evaluated by comparing the test results of two tests (test-retest), which will be executed by the same tester. The two tests will be executed on the same day within 4 hours. The intra-class correlation coefficient of the ranked MMMT levels (analogue to the primary endpoint) will be used to describe the intra-rater reliability of the MMMT.
Time Frame
Baseline- Baseline plus 4 hours
Title
Validity of the Modified Manual Muscle Test
Description
The inter-rater reliability of the BMRC will be measured by the ICC. The ICC of the BMRC will be estimated and analysed as previously described for the primary analysis. The ICCs of the MMMT and the BMRC will be compared descriptively.
The test-retest reliability of the MMMT and the BMRC will be estimated for each rater separately using a two-way random-effects ANOVA, including the patient and "test type" (test/retest) as random effects. The ICC estimates will be reported with the 95% CI and compared descriptively between the raters using the same test and between the tests (MMMT vs BMRC).
The pairwise correlations of the MMMT and the BMRC with the muscle strength as assessed by the microFET2 will be investigated graphically (scatterplots and/or boxplots). Furthermore, Spearman's rank correlation coefficient will be presented with the corresponding 95% CI and p-values.
Time Frame
Baseline- Baseline plus 4 hours
Title
Modified Tardieu Scale level
Description
The BMRC has 6 levels, which makes the scale robust and reliable but insensitive to change. In addition, the BMRC does not consider spasticity. The MMMT has 12 levels, which makes it more sensitive, but it also might mean that the scale is less reliable. Because the MMMT considers spasticity, we expect that this compensates for the possible loss of reliability. It is assumed that the MMMT is less sensitive to spasticity than the BMRC. Thus, for patients with a different level of spasticity measured by the Modified Tardieu Scale, both the inter-rater and the test-retest reliability of the MMMT are expected to be equal to those of the BMRC.
The primary and secondary analyses will thus be repeated for the subgroups of high-spasticity and low-spasticity patients separately (assuming that a reasonable number of patients per subgroup and endpoint are available).
Time Frame
Baseline- Baseline plus 4 hours
Other Pre-specified Outcome Measures:
Title
Bias testing Fatigue
Description
The study may be biased by the multiple testing that cause motor fatigue. The test and retest ratings will be plotted against the respective Numeric Rating Scale fatigue (at the beginning or end of the assessment, respectively) and tested for an overall association and interaction using a linear mixed effects model.
Time Frame
Baseline- Baseline plus 4 hours
10. Eligibility
Sex
All
Minimum Age & Unit of Time
18 Years
Accepts Healthy Volunteers
No
Eligibility Criteria
Inclusion Criteria
diagnosed with MS according to the McDonald criteria
EDSS between 0 and 6.5
older than 18 years of age.
Exclusion Criteria:
An acute episode of MS within 3 months prior to the testing,
grave cognitive changes
distinct fatigue
a history of current back, neck or elbow pain
Overall Study Officials:
First Name & Middle Initial & Last Name & Degree
Nico van der Maas
Organizational Affiliation
Institute for Physiotherapy Research, Biel, Switzerland
Official's Role
Principal Investigator
First Name & Middle Initial & Last Name & Degree
Marcus Dsouza, Dr. med.
Organizational Affiliation
University Hospital Basle, Basle, Switzerland
Official's Role
Principal Investigator
First Name & Middle Initial & Last Name & Degree
Regula Steinlin Egli
Organizational Affiliation
Specialized Group Physiotherapy in MS, Binningen, Switzerland
Official's Role
Principal Investigator
Facility Information:
Facility Name
Felix Platter Hospital
City
Basel
ZIP/Postal Code
4055
Country
Switzerland
12. IPD Sharing Statement
Plan to Share IPD
Undecided
Learn more about this trial
Study to Evaluate the Reliability and Validity of the Modified Manual Muscle Test for Persons With MS
We'll reach out to this number within 24 hrs