High Resolution Immersion Ultrasound for iIOL Power Calculation
Primary Purpose
Cataract
Status
Unknown status
Phase
Not Applicable
Locations
Austria
Study Type
Interventional
Intervention
Cataract surgery
Sponsored by
About this trial
This is an interventional diagnostic trial for Cataract focused on measuring Cataract surgery, High resolution immersion ultrasound
Eligibility Criteria
Inclusion Criteria:
- Cataract
- Age 21 and older
- Able to understand the patient information
- Willing to follow the instructions and attend all follow-up visits
- Willing to sign informed consent prior to surgery
Exclusion Criteria:
- Relevant other ophthalmic diseases that are likely to reduce the refractive outcome, such as pseudoexfoliation syndrome, traumatic cataract, severe corneal scars
- Previous ocular surgeries on the study eye
- Patients who are not able to cooperate, with eccentric fixation or insufficient ability to fixate (tremor, nystagmus)
- Pregnant or lactating women (pregnancy testing will be performed preoperatively on women of reproductive age)
Sites / Locations
- Vienna Institute for Research in Ocular Surgery (VIROS)Recruiting
Arms of the Study
Arm 1
Arm Type
Experimental
Arm Label
ArcScan
Arm Description
High resolution immersion ultrasound measurement before Cataract surgery
Outcomes
Primary Outcome Measures
Difference in mean absolute error in refractive outcome
The difference in refractive error will be measured using auto- and subjective refraction
Secondary Outcome Measures
Anterior chamber depth and lens thickness measurement
Anterior chamber depth and lens thickness will be measured using the IOL Master 700
IOL tilt and decentration
IOL tilt and decentration will be assessed using the Purkinjemeter
Full Information
NCT ID
NCT03749486
First Posted
November 19, 2018
Last Updated
November 19, 2018
Sponsor
Prim. Prof. Dr. Oliver Findl, MBA
1. Study Identification
Unique Protocol Identification Number
NCT03749486
Brief Title
High Resolution Immersion Ultrasound for iIOL Power Calculation
Official Title
To Assess if Using a High Resolution Immersion Ultrasound Measurement Improves Intraocular Lens Power Calculation
Study Type
Interventional
2. Study Status
Record Verification Date
November 2018
Overall Recruitment Status
Unknown status
Study Start Date
January 1, 2018 (Actual)
Primary Completion Date
January 1, 2020 (Anticipated)
Study Completion Date
January 1, 2020 (Anticipated)
3. Sponsor/Collaborators
Responsible Party, by Official Title
Sponsor-Investigator
Name of the Sponsor
Prim. Prof. Dr. Oliver Findl, MBA
4. Oversight
Studies a U.S. FDA-regulated Drug Product
No
Studies a U.S. FDA-regulated Device Product
No
5. Study Description
Brief Summary
Assess is the additional use of high resolution immersion ultrasound measurements improve the refractive outcome after cataract surgery.
Detailed Description
Since the beginning of biometry, immersion ultrasound was shown to be accurate and reproducible. It is important to distinguish between immersion ultrasound techniques and contact ultrasound. The later was shown to be less accurate and examiner dependent.
Although immersion ultrasound has been improved significantly and novel high resolution ultrasound devices are available, the drawback of this technique is that measurement s take longer compared to optical biometry. The advantage of immersion ultrasound is that structures behind the iris are visible, whereas in optical biometry only structures within the pupil are visible.
Immersion ultrasound as well optical biometry can be used to calculate the needed power of an intraocular lens (IOL) to achieve the aimed post-operative refraction. Although IOL power calculation improved within the last decades, refractive surprises occur, especially in cases with very short eyes.
The estimation of the post-operative IOL position and therefore the estimated anterior chamber depth (ACD) is presently the main source of error (35% to 42%) in IOL power calculation and therefore for the refractive outcome of the patients after cataract surgery. Early IOL power calculation formulae, such as the Binkhorst I formula, used a fixed ACD value to predict the position of the IOL, but the refractive results were not appropriate because the post-operative position of the IOL varied significantly between patients. Later observations showed a correlation between the axial eye length and the post-operative ACD (more myopic eyes showed a larger ACD post-operatively). These correlations were taken into account in later developed formulas (such as the Binkhorst II formula). Olsen et al. measured the post-operative ACD and substituted the predicted post-operative ACD with the true, post-operative ACD in each case. The result after correcting the IOL position was a highly accurate IOL power calculation, where no fudge factors were needed. Presently the pre-operatively measured ACD is taken into account for several IOL power calculation formulas, such as the Haigis formula, the Holladay II formula and the Olsen formula. However, this new generation of formulas use the pre-operative ACD, without considering the thickness of the crystalline lens. The ACD is measured as the distance between the anterior surface of the cornea (anatomically speaking this should be the posterior surface of the cornea, but in an optical context, as in IOL power calculations, the anterior surface is used) and the anterior surface of the crystalline lens . Therefore the thickness of the crystalline lens has a significant impact on the predicted post-operative position of the IOL. This parameter was first taken into account by Olsen and later modified by Norrby.
It should be mentioned that IOL power calculations developed from theoretical calculations based on Gaussian optics to regression formulas, such as the SRK formula that uses retrospective data of a large number of patients. All these findings suggest that proper measurements not only of the dimensions of the crystalline lens but also of the lens capsule after removing the crystalline lens are necessary to improve IOL power calculation.
A prototype of a combination of an anterior segment OCT (VISANTE; Carl Zeiss Meditec AG) and an operating microscope (OPMI 200; Carl Zeiss Meditec AG) was introduced that allowed measurements of the crystalline lens as well as the lens capsule itself after removing the crystalline lens of cataract patients intraoperatively. This device uses OCT technology to create high resolution B-scans (=images) of the anterior segment of the eye. The OCT was shown to be highly reproducible for ACD measurements pre-operatively and small changes of the IOL/crystalline lens can be detected.
This prototype set-up was used in a previous study published in the journal "Investigative Ophthalmology & Visual Science". It was shown that intra-operative measurements of the anterior lens capsule were a better predictor for the post-operative lens position than other factors and could improve the refractive outcome theoretically. Furthermore it was shown that intra-operatively measured anterior chamber depth is useful to predict refractive outcome using fourth-generation formulae. A further study aimed to observe, whether the postoperative refractive outcome could be improved theoretically by using both pre- and intra-operative measurements for retrospective IOL power calculation with new eye models.
In a recent study a high resolution swept-source OCT was used to perform the measurements and results were very promising (DIATHLAS; Carl Zeiss Meditec AG, Germany).
However, disadvantage of swept-source OCT technology is that the measured area is only within the pupil, but structures behind the iris cannot be visualised.
Most recent findings suggest that measuring the equator of the lens capsule and the cilliary body could improve IOL power calculation.
One CE marked device that allows measurements behind the iris is the ArcScan Insight 100 scanner. This immersion ultrasound device is a precision high frequency device for imaging and biometry of the eye. A 20-60 MHz transducer scans the eye although its curvature approximates the anterior ocular surface. During this process the device produces images with 1 micron resolution of the cornea or the anterior segment. In addition, measurements can also be made of the anatomic structures comprising the anterior of the eye such as anterior chamber depth, angle-to-angle width, and sulcus-to-sulcus width, and pathologic structures, such as solid masses and cysts.
6. Conditions and Keywords
Primary Disease or Condition Being Studied in the Trial, or the Focus of the Study
Cataract
Keywords
Cataract surgery, High resolution immersion ultrasound
7. Study Design
Primary Purpose
Diagnostic
Study Phase
Not Applicable
Interventional Study Model
Single Group Assignment
Masking
None (Open Label)
Allocation
N/A
Enrollment
40 (Anticipated)
8. Arms, Groups, and Interventions
Arm Title
ArcScan
Arm Type
Experimental
Arm Description
High resolution immersion ultrasound measurement before Cataract surgery
Intervention Type
Procedure
Intervention Name(s)
Cataract surgery
Intervention Description
Cataract surgery will be done following ArcScan measurement
Primary Outcome Measure Information:
Title
Difference in mean absolute error in refractive outcome
Description
The difference in refractive error will be measured using auto- and subjective refraction
Time Frame
12 months
Secondary Outcome Measure Information:
Title
Anterior chamber depth and lens thickness measurement
Description
Anterior chamber depth and lens thickness will be measured using the IOL Master 700
Time Frame
12 months
Title
IOL tilt and decentration
Description
IOL tilt and decentration will be assessed using the Purkinjemeter
Time Frame
12 months
10. Eligibility
Sex
All
Minimum Age & Unit of Time
21 Years
Maximum Age & Unit of Time
105 Years
Accepts Healthy Volunteers
No
Eligibility Criteria
Inclusion Criteria:
Cataract
Age 21 and older
Able to understand the patient information
Willing to follow the instructions and attend all follow-up visits
Willing to sign informed consent prior to surgery
Exclusion Criteria:
Relevant other ophthalmic diseases that are likely to reduce the refractive outcome, such as pseudoexfoliation syndrome, traumatic cataract, severe corneal scars
Previous ocular surgeries on the study eye
Patients who are not able to cooperate, with eccentric fixation or insufficient ability to fixate (tremor, nystagmus)
Pregnant or lactating women (pregnancy testing will be performed preoperatively on women of reproductive age)
Central Contact Person:
First Name & Middle Initial & Last Name or Official Title & Degree
Sahand Amir-Asgari, MD
Phone
01 910 21-57557
Email
office@viros.at
First Name & Middle Initial & Last Name or Official Title & Degree
Julius Hienert, MD
Phone
01 910 21-57564
Email
office@viros.at
Facility Information:
Facility Name
Vienna Institute for Research in Ocular Surgery (VIROS)
City
Vienna
ZIP/Postal Code
1140
Country
Austria
Individual Site Status
Recruiting
Facility Contact:
First Name & Middle Initial & Last Name & Degree
Sahand Amir-Asgari, MD
Phone
01 910 21-57557
Email
office@viros.at
First Name & Middle Initial & Last Name & Degree
Julius Hienert, MD
Phone
01 910 21-57564
Email
office@viros.at
12. IPD Sharing Statement
Plan to Share IPD
Undecided
Learn more about this trial
High Resolution Immersion Ultrasound for iIOL Power Calculation
We'll reach out to this number within 24 hrs