Electroacupuncture Frequency-related Effects on Non-specific Low Back Pain in Older Adults.
Low Back Pain
About this trial
This is an interventional treatment trial for Low Back Pain focused on measuring Acupuncture, Electroacupuncture, Low back pain, Aged, Clinical trial
Eligibility Criteria
Inclusion Criteria:
- Over 60 years of age
- Either gender
- Diagnosis of nonspecific low back pain of more than 3 months duration, with or without radiating leg pain, with a minimum pain intensity score of 4 on the 11-point pain numerical rating scale (NRS - Brazilian Portuguese version)
- Walk independently (with or without walking devices)
- Agree to voluntarily participate in this study and sign the consent form.
Exclusion Criteria:
- Previous surgery on the spinal column
- Have a known or suspected serious spinal pathology (e.g., cancer, vertebral fracture, spinal infection or cauda equina syndrome)
- Fear of needles
- Have participated in acupuncture treatment in the previous 30 days
- Wheelchair users.
Sites / Locations
- Federal University of ParanaRecruiting
- University of Sao Paulo General HospitalRecruiting
Arms of the Study
Arm 1
Arm 2
Arm 3
Arm 4
Arm 5
Experimental
Experimental
Experimental
Active Comparator
Placebo Comparator
Low frequency EA
High frequency EA
Alternating frequency EA
Control Group
Placebo Group
25 participants will receive bilateral application of electroacupuncture using a previously calibrated EL 608 electrostimulator (NKL® portable), with the following parameters: balanced asymmetrical biphasic polarized pulse with continuous pulse train with 2Hz; 100ms pulse duration and 0.5ms pulse width; and the maximum current (amplitude) intensity tolerated by the patient and intensified so that sensory habituation is avoided. Trichotomy will be carried out when necessary and the skin will be disinfected with 70% alcohol. With the participant lying down in a ventral position, the needles will be inserted at a 90º inclination with the skin, to a depth at which that the patient reports the "deQi" sensation (≅ 1.5cm).
25 participants will receive 25 participants will receive bilateral application of electroacupuncture using a previously calibrated EL 608 electrostimulator (NKL® portable), with the following parameters: balanced asymmetrical biphasic polarized pulse with continuous pulse train with 100Hz; 100ms pulse duration and 0.5ms pulse width; and the maximum current (amplitude) intensity tolerated by the patient and intensified so that sensory habituation is avoided. Trichotomy will be carried out when necessary and the skin will be disinfected with 70% alcohol. With the participant lying down in a ventral position, the needles will be inserted at a 90º inclination with the skin, to a depth at which that the patient reports the "deQi" sensation (≅ 1.5cm). Sterile and disposable 0.25mm x 30mm stainless steel needles (Dong Bang Acupuncture Inc., Seoul, Korea) will be used. The sessions will last 30 minutes, twice a week, for 5 weeks, totaling 10 sessions.
25 participants will receive 25 participants will receive bilateral application of electroacupuncture using a previously calibrated EL 608 electrostimulator (NKL® portable), with the following parameters: balanced asymmetrical biphasic polarized pulse with continuous pulse train with 100Hz and 2Hz for 3 seconds each; 100ms pulse duration and 0.5ms pulse width; and the maximum current (amplitude) intensity tolerated by the patient and intensified so that sensory habituation is avoided. Trichotomy will be carried out when necessary and the skin will be disinfected with 70% alcohol. With the participant lying down in a ventral position, the needles will be inserted at a 90º inclination with the skin, to a depth at which that the patient reports the "deQi" sensation (≅ 1.5cm). Sterile and disposable 0.25mm x 30mm stainless steel needles (Dong Bang Acupuncture Inc., Seoul, Korea) will be used. The sessions will last 30 minutes, twice a week, for 5 weeks, totaling 10 sessions.
25 participants will follow exactly the same protocol as the experimental groups, however they will not undergo electrical stimulation, as the acupuncturist will activate channels that are not connected to the patient. Sterile and disposable 0.25mm x 30mm stainless steel needles (Dong Bang Acupuncture Inc., Seoul, Korea) will be used. The sessions will last 30 minutes, twice a week, for 5 weeks, totaling 10 sessions.
25 participants will will follow exactly the same protocol as the experimental groups, however an adhesive moxa (Dong Yang®) will be placed on each acupoint and the needle will be inserted over it, so that the participant only feels the needle prick, but without perforation of the skin and the "deQi" sensation. In addition, as in the control group, the electrodes will be connected to the needles, however, no electrical current will be applied. Sterile and disposable 0.25mm x 30mm stainless steel needles (Dong Bang Acupuncture Inc., Seoul, Korea) will be used. The sessions will last 30 minutes, twice a week, for 5 weeks, totaling 10 sessions.