search
Back to results

Cardiac Magnetic Resonance Imaging Versus Computed Tomography to Guide Transcatheter Aortic Valve Replacement (TAVR-CMR)

Primary Purpose

Aortic Stenosis

Status
Completed
Phase
Not Applicable
Locations
Austria
Study Type
Interventional
Intervention
TAVR-CMR
TAVR-CT
Sponsored by
Medical University Innsbruck
About
Eligibility
Locations
Arms
Outcomes
Full info

About this trial

This is an interventional diagnostic trial for Aortic Stenosis

Eligibility Criteria

18 Years - 99 Years (Adult, Older Adult)All SexesDoes not accept healthy volunteers

Inclusion Criteria:

  1. Signed informed consent
  2. Severe aortic stenosis according to recent guidelines (aortic valve area ≤ 1.0cm² or aortic valve index ≤ 0.6 cm²/m²) (1)
  3. Typical symptoms of severe aortic stenosis like shortness of breath, angina or syncope
  4. Patient is evaluated for TAVR

Exclusion Criteria:

  1. Contraindications to perform CMR
  2. Contraindications to perform CT
  3. Contraindications for TAVR or reduced life expectancy < 1 year.
  4. Known hypersensitivity to CMR or CT contrast agents
  5. Killip class ≥ 3
  6. Childbearing potential or inability to exclude pregnancy
  7. Inability to understand and follow study-related instructions
  8. Severe renal insufficiency requiring renal replacement therapy
  9. Severe hepatic insufficiency (Child-Pugh class B or C)
  10. Post organ transplantation
  11. Participation in another clinical study

Sites / Locations

  • University Clinic of Internal Medicine III

Arms of the Study

Arm 1

Arm 2

Arm Type

Other

Other

Arm Label

TAVR-CMR

TAVR-CT

Arm Description

All MR examinations will be performed with a 1.5-T clinical MR imaging unit (AVANTO_fit; Siemens, Erlangen, Germany). The MR protocol consists of a Navigator-gated free breathing 3D "whole-heart" coronary magnetic resonance angiography (MRA), axial 2D true fast imaging with steady-state free precession (true-FISP) during free breathing covering whole body trunk and a coronal 3D fast low-angle shot (FLASH) Gd-MRA.

All CT examinations will be performed on a 128-slice dual-source CT and high-pitch factor. Prospective electrocardiographic synchronization will be applied, triggered into the diastolic phase for the heart. An injected bolus of 70 to 110 mL of nonionic iodine contrast agent will be applied with 370 mg/mL iodine concentration, using an automatic injector at a flow rate of 5 mL/s, followed by 40 mL saline solution. Contrast agent volume for each patient will be calculated by scan time and body weight. Patients will be placed supine with arms overhead. The scan length range from supraaortic branches to the groins.

Outcomes

Primary Outcome Measures

The non-inferiority of TAVR-CMR compared to TAVR-CT to guide TAVR according to clinical efficacy, defined as implantation success based on the VARC-2 criteria.
The primary outcome will be a composite clinical efficacy end-point related to implantation success at hospital discharge, based on the VARC-2 criteria: Absence of procedural mortality AND correct positioning of the prosthetic valve AND intended performance of the prosthetic valve (mean aortic valve gradient < 20mmHg and no valve regurgitation > mild)

Secondary Outcome Measures

Full Information

First Posted
February 4, 2019
Last Updated
August 7, 2023
Sponsor
Medical University Innsbruck
Collaborators
Johannes Kepler University of Linz, Klinikum Wels-Grieskirchen
search

1. Study Identification

Unique Protocol Identification Number
NCT03831087
Brief Title
Cardiac Magnetic Resonance Imaging Versus Computed Tomography to Guide Transcatheter Aortic Valve Replacement
Acronym
TAVR-CMR
Official Title
Cardiac Magnetic Resonance Imaging Versus Computed Tomography to Guide Transcatheter Aortic Valve Replacement: A Randomized Multicenter Trial
Study Type
Interventional

2. Study Status

Record Verification Date
August 2023
Overall Recruitment Status
Completed
Study Start Date
October 30, 2017 (Actual)
Primary Completion Date
August 5, 2023 (Actual)
Study Completion Date
August 5, 2023 (Actual)

3. Sponsor/Collaborators

Responsible Party, by Official Title
Sponsor
Name of the Sponsor
Medical University Innsbruck
Collaborators
Johannes Kepler University of Linz, Klinikum Wels-Grieskirchen

4. Oversight

Studies a U.S. FDA-regulated Drug Product
No
Studies a U.S. FDA-regulated Device Product
No
Data Monitoring Committee
No

5. Study Description

Brief Summary
To prove the non-inferiority of TAVR-CMR compared to TAVR-CT to guide TAVR according to clinical efficacy, defined as implantation success based on the VARC-2 criteria.
Detailed Description
Study Title: Cardiac Magnetic Resonance Imaging Versus Computed Tomography to Guide Transcatheter Aortic Valve Replacement (TAVR-CMR). Coordinating Prinicpal Investigator: Prof. Bernhard Metzler, University Clinic of Internal Medicine III, Cardiology and Angiology, Innsbruck Medical University. Planned Study Period: 2017-2023. Objective: To investigate, for the first time, the non-inferiority of TAVR-CMR to contrast-enhanced computed tomography (TAVR-CT) regarding efficacy and safety end-points. Design: Prospective, randomized, open-label, multi-centre trial. Patients (planned): 270 patients. Diagnosis / Inclusion Criteria: Symptomatic severe aortic stenosis scheduled for TAVR based on a local heart-team decision. Methods: Patients will be randomized in a 1:1 fashion to receive a predefined TAVR-CMR protocol or to receive a standard TAVR-CT protocol within two weeks after inclusion. Main Outcome Measure: Follow-up will be performed at hospital discharge after TAVR and after 6 months. The primary efficacy outcome is device implantation success at discharge. The secondary endpoints are a combined safety endpoint and a combined clinical efficacy endpoint at baseline and at 6 months, as well as a comparison of imaging procedure related variables (see section 5.11.2). Endpoint definitions are based on the updated 2012 VARC-2 consensus document.

6. Conditions and Keywords

Primary Disease or Condition Being Studied in the Trial, or the Focus of the Study
Aortic Stenosis

7. Study Design

Primary Purpose
Diagnostic
Study Phase
Not Applicable
Interventional Study Model
Parallel Assignment
Masking
None (Open Label)
Allocation
Randomized
Enrollment
267 (Actual)

8. Arms, Groups, and Interventions

Arm Title
TAVR-CMR
Arm Type
Other
Arm Description
All MR examinations will be performed with a 1.5-T clinical MR imaging unit (AVANTO_fit; Siemens, Erlangen, Germany). The MR protocol consists of a Navigator-gated free breathing 3D "whole-heart" coronary magnetic resonance angiography (MRA), axial 2D true fast imaging with steady-state free precession (true-FISP) during free breathing covering whole body trunk and a coronal 3D fast low-angle shot (FLASH) Gd-MRA.
Arm Title
TAVR-CT
Arm Type
Other
Arm Description
All CT examinations will be performed on a 128-slice dual-source CT and high-pitch factor. Prospective electrocardiographic synchronization will be applied, triggered into the diastolic phase for the heart. An injected bolus of 70 to 110 mL of nonionic iodine contrast agent will be applied with 370 mg/mL iodine concentration, using an automatic injector at a flow rate of 5 mL/s, followed by 40 mL saline solution. Contrast agent volume for each patient will be calculated by scan time and body weight. Patients will be placed supine with arms overhead. The scan length range from supraaortic branches to the groins.
Intervention Type
Diagnostic Test
Intervention Name(s)
TAVR-CMR
Intervention Description
CMR protocol for the exact determination of the aortic valve dimensions, valve size and implantation route.
Intervention Type
Diagnostic Test
Intervention Name(s)
TAVR-CT
Intervention Description
CT protocol for the exact determination of the aortic valve dimensions, valve size and implantation route.
Primary Outcome Measure Information:
Title
The non-inferiority of TAVR-CMR compared to TAVR-CT to guide TAVR according to clinical efficacy, defined as implantation success based on the VARC-2 criteria.
Description
The primary outcome will be a composite clinical efficacy end-point related to implantation success at hospital discharge, based on the VARC-2 criteria: Absence of procedural mortality AND correct positioning of the prosthetic valve AND intended performance of the prosthetic valve (mean aortic valve gradient < 20mmHg and no valve regurgitation > mild)
Time Frame
6 months

10. Eligibility

Sex
All
Minimum Age & Unit of Time
18 Years
Maximum Age & Unit of Time
99 Years
Accepts Healthy Volunteers
No
Eligibility Criteria
Inclusion Criteria: Signed informed consent Severe aortic stenosis according to recent guidelines (aortic valve area ≤ 1.0cm² or aortic valve index ≤ 0.6 cm²/m²) (1) Typical symptoms of severe aortic stenosis like shortness of breath, angina or syncope Patient is evaluated for TAVR Exclusion Criteria: Contraindications to perform CMR Contraindications to perform CT Contraindications for TAVR or reduced life expectancy < 1 year. Known hypersensitivity to CMR or CT contrast agents Childbearing potential or inability to exclude pregnancy Inability to understand and follow study-related instructions Severe renal insufficiency requiring renal replacement therapy Severe hepatic insufficiency (Child-Pugh class B or C) Post organ transplantation Participation in another clinical study
Overall Study Officials:
First Name & Middle Initial & Last Name & Degree
Bernhard Metzler, Prof.
Organizational Affiliation
Medical University Innsbruck
Official's Role
Principal Investigator
Facility Information:
Facility Name
University Clinic of Internal Medicine III
City
Innsbruck
State/Province
Tirol
ZIP/Postal Code
6020
Country
Austria

12. IPD Sharing Statement

Plan to Share IPD
No
Citations:
PubMed Identifier
36056444
Citation
Klug G, Reinstadler S, Troger F, Holzknecht M, Reindl M, Tiller C, Lechner I, Fink P, Pamminger M, Kremser C, Ulmer H, Bauer A, Metzler B, Mayr A. Cardiac magnetic resonance imaging versus computed tomography to guide transcatheter aortic valve replacement: study protocol for a randomized trial (TAVR-CMR). Trials. 2022 Sep 2;23(1):726. doi: 10.1186/s13063-022-06638-6.
Results Reference
derived

Learn more about this trial

Cardiac Magnetic Resonance Imaging Versus Computed Tomography to Guide Transcatheter Aortic Valve Replacement

We'll reach out to this number within 24 hrs